HI-98394 GPS Multiparameter Portable pH, EC, ISE, Turbidity, DO Meter with Autonomously Logging Probe

HI-98394 is a portable logging multiparameter system (meter and autonomously logging probe) that monitors up to 14 different water quality parameters (7 measured and 7 calculated) such as pH, ORP, turbidity, dissolved oxygen, conductivity, chloride, nitrate, ammonium and temperature. Each parameter is fully configurable.

The HI-98394 is designed to withstand harsh environmental conditions and is ideal for field measurements and all the applications listed above. Each meter comes with a protective rubber boot and meets IP67 standard (30 minutes immersion at 1 meter depth). The multi-sensor probe is totally sealed against water and dust. Plus, it meets IP68 standard (continuous immersion in water).

HI-98394 has a graphic, backlit display that automatically sizes the digits to fit the screen with on screen graphing capability. HI-98394 features an internal 12-channel GPS receiver/antenna module that guarantees a position accuracy of 10 m (30 ft). GPS information can be transferred to a PC and can be viewed using GPS mapping software.

Clicking on visited locations, using a mapping software, displays the measurement information. The GPS coordinates are shown on the LCD together with up to 10 measurement parameters recorded with logged data.

A 3-bar antenna indicator, in the bottom right corner of the LCD, indicates GPS signal strength. The multi-sensor probe features an internal temperature sensor and a removable protective shield.

The HI-98394 system is easy to setup and use. The built-in tutorial mode guides users step-by-step through sensor preparation, installation, maintenance, and calibration processes.

The meter can log data that can be easily downloaded as a .csv file (or graph) to a type-C, USB flash drive.

Rugged Custom Carrying Case

The HI-98394 meter, probe, and all accessories is supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all components.

What's included:

  • HI-7698394/4 Autonomously logging multi-sensor probe
  • HI-76983948 Atmospheric pressure box
  • Probe connector protection cover
  • 1.5V AA alkaline batteries (8 pcs.)
  • HI-7698194-1 pH / ORP sensor (pre-installed on the probe)
  • HI-7698594-4 EC / Turbidity sensor (pre-installed on the probe)
  • HI-7698194-2 Galvanic DO sensor (pre-installed on the probe)
  • HI-7698296 Long protective probe shield
  • HI-7698293 Long calibration beaker
  • HI-9828-20 Quick calibration standard solution (230 mL)
  • HI-9829-16 0 FNU calibration solution (230 mL)
  • HI-9829-17 20 FNU calibration solution (230 mL)
  • HI-9829-18 200 FNU calibration solution (230 mL)
  • HI-710036 Protective rubber boot (fitted on meter)
  • HI-920019 USB-C to USB-C cable
  • Probe maintenance kit includes: DO galvanic membranes, o-rings for DO sensor, o-rings for probe, electrolyte solution for DO sensor, 5 mL syringe, scouring pad, sensor-socket protection*, hex key, small brush, sachet with silicone grease
  • Instrument quality certificate
  • Sensors and probe quality certificates
  • Quick reference with QR code for manual download

Warranty

  • 2 Years meter
  • 6 months sensors and probes

About the probe and sensors

Autonomously Logging Probe

Storage of up to 140,000 individual samples or 35,000 complete sample data sets with date and time stamp thus permitting up to a 70 day deployment with all channels logging at 10 minute intervals.

Pre-installed Sensors

Supplied with pre-installed pH/ORP, EC/Turbidity and DO sensors.

Quick Sensor Replacement

Sensor replacement is quick and easy with field replaceable, screw type connectors and colour-coded bodies.

Auto-Sensor Recognition

This meter automatically recognises sensors.

Temperature Sensor

The probe incorporates a temperature sensor for temperature compensation of all parameters. Accurate temperature reading in degrees Celsius, Fahrenheit and kelvin are displayed.

Field Ready

For field calibration, our quick calibration solution allows standardization of pH and conductivity with one calibration solution.

Quick Calibration

Simply screw the calibration beaker filled with Quick Calibration solution onto the probe, select “Quick calibration” from the menu and press OK. Individual calibration may also be performed using multiple calibration points.

Specifications

pH / mV
Range 0.00 to 14.00 pH / ±600.0 mV
Resolution 0.01 pH / 0.1 mV
Accuracy ±0.05 pH / ±3.0 mV
Calibration One-point Quick Calibration using HI-9828-20; up to three points using pH 4.01, 6.86, 7.01, 9.18, 10.01) standard buffers or one custom buffer
ORP
Range ±2000.0 mV
Resolution 0.1 mV
Accuracy (evaluated with a calibrated system at ambient temperature) ±10 mV
Calibration Automatic at one custom point (relative mV)
EC
Range 0 to 200 mS/cm0 to 400 mS/cm (absolute)
Resolution manual: 1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 μS/cm from 0 to 9999 μS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
Accuracy (evaluated with a calibrated system at ambient temperature) ±1% of reading or ±1 μS/cm whichever is greater
Calibration One-point Quick Calibration using HI-9828-20; One point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS
Range 0 to 400000 ppm (mg/L) (the maximum value depends on the TDS factor)
Resolution manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L)
Accuracy ±1% of reading or ±1 ppm (mg/L) whichever is greater
Calibration based on conductivity or salinity calibration
Resistivity
Range 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm depending on resistivity reading
Resolution 1 Ω•cm; 0.1 k Ω•cm; 0.0001 M Ω•cm
Calibration Based on conductivity or salinity calibration
Salinity
Range 0.00 to 70.00 PSU
Resolution 0.01 PSU
Accuracy ±2% of reading or ±0.01 PSU whichever is greater
Calibration One point, using a custom solution
Seawater Sigma
Range 0.0 to 50.0 σt, σ₀, σ₁₅
Resolution 0.1 σt, σ₀, σ₁₅
Accuracy ±1 σt, σ₀, σ₁₅
Calibration based on conductivity or salinity calibration
Turbidity
Range 0.0 to 99.9 FNU; 100 to 1000 FNU
Resolution 0.1 FNU from 0.0 to 99.9 FNU1 FNU from 100 to 1000 FNU
Accuracy ±0.3 FNU or ±2% of reading, whichever is greater
Calibration Automatic up to 3 points at 0, 20 and 200 FNU or custom
Dissolved Oxygen
Range 0.0 to 500.0% saturation; 0.00 to 50.00 ppm (mg/L)
Resolution 0.1% saturation; 0.01 ppm (mg/L)
Accuracy (evaluated with a calibrated system at ambient temperature) ±1.5% of reading from 0.0-200.0% saturation;±5% of reading from 200.0-500.0 % saturation;±1.5% of reading from 0.00-20.00 mg/L;±5% of reading from 20.00-50.00 mg/L
Calibration One point, quick calibration in water saturated air; One or two-point at 100% and 0%; One point using a custom solution, % saturation or mg/L
Pressure Compensation Automatic: 450 to 850 mmHg
Atmospheric Pressure
Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Accuracy ±3 mm Hg within ±15°C from calibration temperature
Calibration automatic at one custom point
Temperature
Range -5.00 to 50.00°C; 23.00 to 122.00°F; 268.15 to 323.15K
Resolution 0.01°C; 0.01°F; 0.01K
Accuracy ±0.15°C; ±0.27°F; ±0.15K
Calibration Automatic at one custom point
Ammonium-Nitrogen
Range 0.02 to 200.00 ppm Am (as NH4+-N)
Resolution 0.01 ppm to 1.00 ppm; 0.1 ppm to 200.0 ppm
Accuracy ±5% of reading or 2ppm whichever is greater
Calibration 1 or 2 point, 10 ppm and 100 ppm
Chloride
Range 0.6 to 200.00 ppm Cl (as Cl-
Resolution 0.01 ppm to 1 ppm; 0.1 ppm to 200.0 ppm
Accuracy ±5% of reading or 2ppm whichever is greater
Calibration 1 or 2 point, 10 ppm and 100 ppm
Nitrate-Nitrogen
Range 0.62 to 200.00 ppm N (as NO3--N)
Resolution 0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
Accuracy ±5% of reading or 2ppm whichever is greater
Calibration 1 or 2 point, 10 ppm and 100 ppm
Additional Specifications
Temperature Compensation automatic from -5 to 50°C (23 to 122°F) 268.15 to 323.15K
Logging Memory Probe only: 140,000 measurements (single parameter logged); 35,000 measurements (all parameters logged)meter and probe: interval logging 50,000 records total or log-on-demand (all parameters) 15,000 records
Logging Interval one second to three hours
GPS yes, 12 channel receiver
Connectivity USB-C (HOST) functions – Mass storage host; USB-C (device) functions – Mass storage device
Protection Rating IP67
Environment 0 to 50°C (32 to 122°F); RH 100%
Battery Type / Life 1.5V AA alkaline batteries (4)
Battery Life Approximately 40 hours with logging every 1 second, all parameters enabled and GPS on
Dimensions / Weight 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) / 435g (13.3 oz.)
Probe Specification – HI-7698394
Sensor Inputs 1 – pH, pH/ORP, ammonium ISE, Chloride ISE, or Nitrate ISE 2 – Dissolved Oxygen 3 – EC, EC/Turbidity
Sample Environment Fresh, brackish, seawater
Waterproof Protection IP68
Operating Temperature -5.0 to 50.0°C
Storage Temperature -20.0 to 70.0°C
Maximum depth 20m (66 feet) - reduced for ISE sensors
Dimensions (without cable) 442mm; 46mm diameter
Weight (with sensors and batteries) 775g
Cable specification Multistrand-multiconductor shielded cable with internal strength member rated for 68kg (150lb) intermittent use
Wetted materials Body – ABSThreads – NylonShield – ABS/316 SSTemperature Probe – 316 SSO-rings - EPDM
Sensor Specifications:
HI-7698194-1 pH/ORP sensor
Measurement type pH, mV (pH/ORP)
Measurement range 0.00 to 12.00 pH; ±600.0mV (pH); ±2000.0mV (ORP)
Temperature range -5.0 to 50.0°C
Colour Code Red
Materials Glass tip (pH) and ORP (Platinum), Wick junction, PEI body, electrolyte gel and double reference
Maintenance solution HI-70300 storage solution
Dimensions 118 x 15mm
HI-7698594-4 EC/Turbidity sensor
Measurement unit µS/cm, mS/cm, FNU
Measurement range 0 to 200.0 mS/cm0.0 to 400 mS/cm (absolute)0.0 to 1000 FNU
Temperature range -5.0 to 50.0°C
Colour Code Blue
Materials Body: ABS/EPOXY; Electrodes – Stainless Steel (AISI 316)
Maintenance solution None
Dimensions 135 x 35mm
HI-7698194-2 DO sensor
Measurement unit DO (% saturation and concentration)
Measurement range 0.0 to 500.0 %0.00 to 50.00 mg/L
Temperature range -5 to 55˚C
Colour Code White
Materials Tip – cat/an: Ag/Zn; junction – membrane HDPE; Body - ABS
Maintenance solution HI-7042S (DO electrolyte)
Dimensions 99 x 17mm

Frequently Asked Questions

Clear answers to help you choose the right water testing solution with confidence