Hanna Instruments HI-98294 GPS Multiparameter Portable pH, EC, ISE, Turbidity, DO Meter

Sale price£2,090.00 Regular price£2,200.00
Save £110.00

HI-98294 GPS Multiparameter Portable pH, EC, ISE, Turbidity, DO Meter

HI-98294 is a portable logging multiparameter system (meter and probe) that monitors up to 14 different water quality parameters (7 measured and 7 calculated) such as pH, ORP, turbidity, dissolved oxygen, conductivity, chloride, nitrate, ammonium and temperature.

Each parameter is fully configurable. HI-98294 has a graphic, backlit display that automatically sizes the digits to fit the screen with on screen graphing capability.

HI-98294 features an internal 12-channel GPS receiver / antenna module that guarantees a position accuracy of 10 m (30 ft). GPS information can be transferred to a PC and can be viewed using GPS mapping software. Clicking on visited locations, using a mapping software, displays the measurement information.

The GPS coordinates are shown on the LCD together with up to 10 measurement parameters, which are recorded with logged data. A 3-bar antenna indicator, in the bottom right corner of the LCD, indicates GPS signal strength. The multi-sensor probe features an internal temperature sensor and a removable protective shield.

Each meter comes with a protective rubber boot and meets IP67 standard (30 minutes immersion at 1 meter depth). The multi-sensor probe is totally sealed against water and dust, and meets IP68 standard (continuous immersion in water).

Main features

  • Monitors up to 14 different water quality parameters
  • Rugged, water-resistant meter and waterproof probe
  • Field-replaceable sensors with auto recognition
  • Instantaneous conductivity and turbidity measurements
  • Built-in barometer for percent saturation and DO concentration compensation
  • Good Laboratory Practice feature, the last 5 calibrations are automatically stored
  • Graphical display of logged data on backlit LCD screen
  • Log-on-demand and automatic logging on meter for all parameters
  • Quick calibration feature to provide single point calibration for pH, conductivity, and dissolved oxygen with one solution
  • Probe shipped with sensors installed
  • Waterproof Quick Connect DIN connection between meter and probe
  • USB-C interface for PC communication

The HI-98294 system is easy to setup and use. The built-in tutorial mode guide users step-by-step through sensor preparation, installation, maintenance, and calibration processes. The meters can log data that can be easily downloaded as a .csv file (or graph) to a type-C, USB flash drive.

Rugged Custom Carrying Case

The HI-98294 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all components.

What's included:

  • HI-7698294/4 Multi-sensor probe
  • 1.5V AA alkaline batteries (4 pcs.)
  • HI-7698194-1 pH / ORP sensor (pre-installed on the probe)
  • HI-7698594-4 EC / Turbidity sensor (pre-installed on the probe)
  • HI-7698194-2 Galvanic DO sensor (pre-installed on the probe)
  • HI-7698296 Long protective probe shield
  • HI-7698293 Long calibration beaker
  • HI-9828-20 Quick calibration standard solution (230 mL)
  • HI-9829-16 0 FNU calibration solution (230 mL)
  • HI-9829-17 20 FNU calibration solution (230 mL)
  • HI-9829-18 200 FNU calibration solution (230 mL)
  • HI-710036 Protective rubber boot (fitted on meter)
  • HI-920019 USB-C to USB-C cable
  • Probe maintenance kit includes: DO galvanic membranes, o-rings for DO sensor, o-rings for probe, electrolyte solution for DO sensor, 5 mL syringe, scouring pad, sensor-socket protection, hex key, small brush, sachet with silicone grease
  • Instrument quality certificate
  • Sensors and probe quality certificates
  • Quick reference with QR code for manual download Warranty 2 Years meter 6 months sensors and probes

Specifications

pH / mV
Range 0.00 to 14.00 pH / ±600.0 mV
Resolution 0.01 pH / 0.1 mV
Accuracy ±0.05 pH / ±3.0 mV
Calibration One-point Quick Calibration using HI-9828-20; up to three points using pH 4.01, 6.86, 7.01, 9.18, 10.01) standard buffers or one custom buffer
ORP
Range ±2000.0 mV
Resolution 0.1 mV
Accuracy (evaluated with a calibrated system at ambient temperature) ±10 mV
Calibration Automatic at one custom point (relative mV)
EC
Range 0 to 200 mS/cm0 to 400 mS/cm (absolute)
Resolution manual: 1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 μS/cm from 0 to 9999 μS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
Accuracy (evaluated with a calibrated system at ambient temperature) ±1% of reading or ±1 μS/cm whichever is greater
Calibration One-point Quick Calibration using HI-9828-20; One point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS
Range 0 to 400000 ppm (mg/L) (the maximum value depends on the TDS factor)
Resolution manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L)
Accuracy ±1% of reading or ±1 ppm (mg/L) whichever is greater
Calibration based on conductivity or salinity calibration
Resistivity
Range 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm depending on resistivity reading
Resolution 1 Ω•cm; 0.1 k Ω•cm; 0.0001 M Ω•cm
Calibration Based on conductivity or salinity calibration
Salinity
Range 0.00 to 70.00 PSU
Resolution 0.01 PSU
Accuracy ±2% of reading or ±0.01 PSU whichever is greater
Calibration One point, using a custom solution
Seawater Sigma
Range 0.0 to 50.0 σt, σ₀, σ₁₅
Resolution 0.1 σt, σ₀, σ₁₅
Accuracy ±1 σt, σ₀, σ₁₅
Calibration based on conductivity or salinity calibration
Turbidity
Range 0.0 to 99.9 FNU; 100 to 1000 FNU
Resolution 0.1 FNU from 0.0 to 99.9 FNU1 FNU from 100 to 1000 FNU
Accuracy ±0.3 FNU or ±2% of reading, whichever is greater
Calibration Automatic up to 3 points at 0, 20 and 200 FNU or custom
Dissolved Oxygen
Range 0.0 to 500.0% saturation; 0.00 to 50.00 ppm (mg/L)
Resolution 0.1% saturation; 0.01 ppm (mg/L)
Accuracy (evaluated with a calibrated system at ambient temperature) ±1.5% of reading from 0.0-200.0% saturation;±5% of reading from 200.0-500.0 % saturation;±1.5% of reading from 0.00-20.00 mg/L;±5% of reading from 20.00-50.00 mg/L
Calibration One point, quick calibration in water saturated air; One or two-point at 100% and 0%; One point using a custom solution, % saturation or mg/L
Pressure Compensation Automatic: 450 to 850 mmHg
Atmospheric Pressure
Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Accuracy ±3 mm Hg within ±15°C from calibration temperature
Calibration automatic at one custom point
Temperature
Range -5.00 to 50.00°C; 23.00 to 122.00°F; 268.15 to 323.15K
Resolution 0.01°C; 0.01°F; 0.01K
Accuracy ±0.15°C; ±0.27°F; ±0.15K
Calibration Automatic at one custom point
Ammonium-Nitrogen
Range 0.02 to 200.00 ppm Am (as NH4+-N)
Resolution 0.01 ppm to 1.00 ppm; 0.1 ppm to 200.0 ppm
Accuracy ±5% of reading or 2ppm whichever is greater
Calibration 1 or 2 point, 10 ppm and 100 ppm
Chloride
Range 0.6 to 200.00 ppm Cl (as Cl-
Resolution 0.01 ppm to 1 ppm; 0.1 ppm to 200.0 ppm
Accuracy ±5% of reading or 2ppm whichever is greater
Calibration 1 or 2 point, 10 ppm and 100 ppm
Nitrate-Nitrogen
Range 0.62 to 200.00 ppm N (as NO3--N)
Resolution 0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
Accuracy ±5% of reading or 2ppm whichever is greater
Calibration 1 or 2 point, 10 ppm and 100 ppm
Additional Specifications
Temperature Compensation automatic from -5 to 50°C (23 to 122°F) 268.15 to 323.15K
Logging Memory Interval logging 50,000 records or log-on-demand (all parameters) 15,000 records
Logging Interval one second to three hours
GPS yes, 12 channel receiver
Connectivity USB-C (HOST) functions – Mass storage host; USB-C (device) functions – Mass storage device
Protection Rating IP67
Environment 0 to 50°C (32 to 122°F); RH 100%
Battery Type / Life 1.5V AA alkaline batteries (4)
Battery Life Approximately 40 hours with logging every 1 second, all parameters enabled and GPS on
Dimensions / Weight 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) / 435g (13.3 oz.)
Probe Specification – HI-7698294
Sensor Inputs pH, pH/ORP Dissolved Oxygen EC, EC/Turbidity
Sample Environment Fresh, brackish, seawater
Waterproof Protection IP68
Operating Temperature -5.0 to 50.0°C
Storage Temperature -20.0 to 70.0°C
Maximum depth 20m (66 feet)
Dimensions (without cable) 342mm; 46mm diameter
Weight (with sensors and batteries) 570g
Cable specification Multistrand-multiconductor shielded cable with internal strength member rated for 90kg intermittent use
Wetted materials Body – ABSThreads – NylonShield – ABS/316 SSTemperature Probe – 316 SSO-rings - EPDM
Sensor Specifications:
HI-7698194-1 pH/ORP sensor
Measurement type pH, mV (pH/ORP)
Measurement range 0.00 to 12.00 pH; ±600.0mV (pH); ±2000.0mV (ORP)
Temperature range -5.0 to 50.0°C
Colour Code Red
Materials Glass tip (pH) and ORP (Platinum), Wick junction, PEI body, electrolyte gel and double reference
Maintenance solution HI-70300 storage solution
Dimensions 118 x 15mm
HI-7698594-4 EC/Turbidity sensor
Measurement unit µS/cm, mS/cm, FNU
Measurement range 0 to 200.0 mS/cm0.0 to 400 mS/cm (absolute)0.0 to 1000 FNU
Temperature range -5.0 to 50.0°C
Colour Code Blue
Materials Body: ABS/EPOXY; Electrodes – Stainless Steel (AISI 316)
Maintenance solution None
Dimensions 135 x 35mm
HI-7698194-2 DO sensor
Measurement unit DO (% saturation and concentration)
Measurement range 0.0 to 500.0 %0.00 to 50.00 mg/L
Temperature range -5 to 55˚C
Colour Code White
Materials Tip – cat/an: Ag/Zn; junction – membrane HDPE; Body - ABS
Maintenance solution HI-7042S (DO electrolyte)
Dimensions 99 x 17mm

Frequently Asked Questions

Clear answers to help you choose the right water testing solution with confidence