Hanna Instruments HI-97734 Free & total Chlorine High Range portable photometer

Sale price£475.00 Regular price£507.50
Save £32.50

HI-97734 is an advanced portable photometer for the measurement of HR free and total chlorine in water. 

 Chlorine
 Advanced Optical System

HI-97734 is an advanced portable photometer for the measurement of HR free and total chlorine in water.

This meter offers a superior optical system that utilises a reference detector and narrow band interference filters for extremely fast and repeatable measurements.

  • The HI-97734 meter measures free and total chlorine (Cl2) in water samples
  • No warm up time before taking a measurement
  • Tutorial mode for step-by-step instructions
  • Uses either powder or cost saving liquid reagents
  • CAL Check
Free Chlorine Range 0.00 to 10.00 mg/L (as Cl2
Free Chlorine Resolution 0.01 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading
Total Chlorine Range UHR 0.00 to 10 mg/L (as Cl2
total Chlorine Resolution 1 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading
Chlorine Method Adaptation of EPA DPD method 330.5
Photometer/Colorimeter Light Source Light emitting diode
Photometer/Colorimeter Light Detector Silicon photocell with narrow band interference filter @ 420 nm
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1.0 nm
Cuvette Type round, 24.6 mm diameter (22 mm inside)
GLP Date, time of last calibration
Display 128 x 64 pixel B/W LCD with backlight
Logging Type automatic logging
Logging Memory 50 measurement
Battery Type/Life 1.5V AA battery (3 pcs.) / > 800 measurements (without backlight)
Automatic Shut-Off After 15 minutes of inactivity (30 minutes before a READ measurement)
Environment 0 to 50°C (32 to 122°F); relative humidity: 100% (IP 67, floating case)
Weight 380g with batteries
Dimensions 142.5 x 102.5 x 50.5 mm
Ordering Information HI-97734 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate.
PLEASE NOTE: In some cases, samples may contain other parameters which may interfere with results
 Interference may be caused by: Alkalinity: above 1,000 mg/L CaCO3 if present as bicarbonate (HCO3 sample pH < 8.3); above 25 mg/L CaCO3 if present as carbonate (CO32, sample pH > 9.0). In both cases, it will not reliably develop the full amount of colour or it may rapidly fade (negative error). To resolve this, neutralise the sample with diluted HCl. Acidity: above 150 mg/L CaCO3. May not reliably develop the full amount of colour or it may rapidly fade (negative error). To resolve this, neutralise the sample with diluted NaOH. Hardness: in case of water with hardness greater than 500 mg/L CaCO3, shake the sample for approximately 2 minutes after adding the powder reagent. Bromine (Br2), Chloride dioxide (ClO2), Iodine (I2), Oxidised Manganese and Chromium, Ozone (O3): positive error.