Hanna Instruments HI-97714 Cyanide Portable photometer
HI-97714 Cyanide Portable photometer has an advanced optical system that uses a Light Emitting Diode (LED) and a narrow band interference filter that allows for accurate and repeatable readings.
Each HI-97714 is delivered in a cardboard box and is supplied with:
- Sample cuvette (2 pcs.)
- Sample cuvette cap (2 pcs.)
- Plastic stopper (2 pcs.)
- 1.5V AA Alkaline batteries
- Instrument quality certificate
- Instruction manual
The HI-97714 is an auto-diagnostic portable photometer that benefits from Hanna’s years of experience as a manufacturer of analytical instruments. It has an advanced optical system that uses a Light Emitting Diode (LED) and a narrow band interference filter that allows for accurate and repeatable readings.
The optical system is sealed from outside dust, dirt and water. The meter uses an exclusive positive-locking system to ensure that the cuvettes are placed into the holder in the same position every time.
With the CAL Check™ functionality, users are able to validate the performance of the instrument at any time and apply a user calibration (if necessary). Hanna Instruments CAL Check cuvettes are made with NIST traceable standards.
The built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents and quantities.
The HI-97714 meter measures the cyanide content in water samples in the 0.000 to 0.200 mg/L (ppm). The method is an adaptation of the Pyridine-Pyrazalone Method.
The HI-97714 photometer is a compact and versatile meter suitable for field or bench measurements, featuring a:
- Sophisticated optical system
- Meter validation using certified CAL Check cuvettes
- Tutorial mode guides the user step-by-step
- Auto logging
- Waterproof IP67, floating case
- GLP features
The internal reference system (reference detector) of the HI-97714 photometer compensates for any drifts due to power fluctuations or ambient temperature changes, providing a stable source of light for your blank (zero) measurement and sample measurement.
LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps have poor blue/violet light output.
Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.
A focusing lens collects all of the light that exits the cuvette, eliminating errors from cuvette imperfections and scratches, eliminating the need to index the cuvette.
REQUIRED REAGENTS
- HI-93714A-0 Cyanide Reagent A
- HI-93714B-0 Cyanide Reagent B
- HI-93714C-0 Cyanide Reagent C
REAGENT SETS
- HI-93714-01 Cyanide Reagent - 100 tests
- HI-93714-03 Cyanide Reagent - 300 tests
About Cyanide
The term cyanide refers to all of the CN groups in cyanide compounds that can be determined as the cyanide ion CN.
Originating in water, primarily from metallurgical and galvanic industrial plants, cyanide is highly toxic to the human nervous system.
Specifications
| Range | 0.000 to 0.200 mg/L (ppm) (as CN-) |
| Resolution | 0.001 mg/L |
| Accuracy | ±0.005 mg/L ±3% of reading |
| Method | Adaptation of the Standard methods for the examination of Water and Wastewater, 18th edition, pyridine-pyrazolone Method |
| Photometer/Colorimeter Light Source | Light emitting diode |
| Photometer/Colorimeter Light Detector | Silicon photocell with narrow band interference filter @ 610 nm |
| Bandpass Filter Bandwidth | 8 nm |
| Bandpass Filter Wavelength Accuracy | ±1.0 nm |
| Cuvette Type | round, 24.6 mm diameter (22 mm inside) |
| GLP | Date, time of last calibration |
| Display | 128 x 64 pixel B/W LCD with backlight |
| Logging Type | automatic logging |
| Logging Memory | 50 measurement |
| Battery Type/Life | 1.5V AA battery (3 pcs.) / > 800 measurements (without backlight) |
| Automatic Shut-Off | After 15 minutes of inactivity (30 minutes before a READ measurement) |
| Environment | 0 to 50°C (32 to 122°F); relative humidity: 100% (IP 67, floating case) |
| Weight | 380g with batteries |
| Dimensions | 142.5 x 102.5 x 50.5 mm |
| Ordering Information | HI-97714 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate. |
| Reagents and CAL Check Standards | HI-97714-11 CAL Check Standard Cuvettes HI-93714-01 Reagents 100 tests HI-93714-03 Reagents 300 tests |
Downloads

Frequently Asked Questions
Clear answers to help you choose the right water testing solution with confidence
Which brands of water testing kits do you supply?
Do you provide kits for both home and professional use?
Yes — whether you’re a pool or spa owner, aquarium keeper, utility company, or a university laboratory, we have the right solution for your needs.
Can I arrange servicing or calibration for my photometer?
Absolutely. We also provide servicing and calibration to keep your photometers accurate and reliable.
How quickly do you dispatch orders?
Orders placed before 2:30 pm (Monday–Friday) are dispatched the same day. We also ship on Saturdays for your convenience.
Which couriers do you use for delivery?
We deliver through UPS, DPD, and Royal Mail. You can also choose to upgrade to next-day delivery at checkout.
What is your return policy?
We accept returns within 14 days of delivery provided the items are unused, in their original packaging, and in resalable condition. Please contact our team before returning any items.
Can I place bulk or business orders?
Yes, we welcome bulk, trade, and institutional orders. For tailored pricing or large quantities, please get in touch with us directly.
How can I get help if I’m unsure which kit to buy?