Hanna Instruments HI-97107C Disinfectants Kit including photometer, CALCheck standards and carry case
The Hanna HI-97107C Disinfectants Photometer kit is designed to measure the 7 most important parameters for Legionella control and compliance. Bromine, Free and Total Chlorine Low range, Total Chlorine UHR, Chlorine Dioxide, Hydrogen Peroxide, Ozone and pH are all included and results are displayed directly on the digital display without the need to refer to charts or tables. The complete kit here allows you to be ready to start testing. NOTE: Items in the actual HI-97107C product case will differ from the display photo here.
HI-97107C Disinfectants Kit including photometer, CALCheck standards and carry case
Each HI-97107C is delivered in a rugged carrying case and is supplied with:
- Sample cuvette with cap (2 pcs.)
- Plastic stopper (2 pcs.)
- Chlorine reagent kit
- Reagent A, 30 mL dropper (1 pc.)
- Reagent B, 30 mL dropper (1 pc.)
- Reagent C, 20 mL dropper (1 pc.)
- pH reagent, 30 mL dropper (1 pc.)
- Bromine reagent (for 25 tests)
- Ozone reagent (for 25 tests)
- Glycine powder (for 25 tests)
- UHR Chlorine reagent kit
- Reagent A (for 25 tests)
- Reagent B (for 25 tests)
- Chlorine Dioxide (rapid) reagent kit
- Reagent A, 30 mL dropper (1 pc.)
- Reagent B (for 25 tests)
- Hydrogen Peroxide reagent, 30 mL dropper (1 pc.)
- Cloth for wiping cuvettes
- Scissors
- 1.5V AA alkaline battery (3 pcs.)
- Battery safety insert
- Quick reference guide with instructions for manual download and instrument quality certificate
About the HI-97107 Disinfectants photometer
This multi-functional photometer is ideal for monitoring in the following industries:
- Legionella control and compliance for risk assessments, monitoring, and disinfectants
- Potable Biocides in spas, pools and drinking water
- Drinking water and wastewater
- Water tanks
- Hot and cold water systems
- Cooling towers and systems
- Papermills
- Water feature maintenance
- Food manufacturing – cleaning lines
- Holiday Parks
- Hospitality
- Hospitals
- Temporary water supplies eg: events
- Facilities management
The HI-97107 is a multiparameter portable photometer designed specifically to meet the needs of Legionella compliance and control. Benefiting from Hanna’s years of experience as a manufacturer of analytical instruments it features the Hanna CAL Check™ functionality for maximum accuracy and the unique to Hanna built-in tutorial mode.
The highly accurate optical system is sealed from outside dust, dirt and water with an exclusive positive-locking system to ensure that the cuvettes are placed into the holder in the same position every time.
With the CAL Check™ functionality, users can validate the performance of the instrument at any time and apply a user calibration (if necessary). Hanna Instruments CAL Check™ cuvettes are made with NIST traceable standards.
The built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents and quantities.
About the seven parameters
Bromine
Bromine is a powerful water disinfectant, particularly effective in hot water (treatment of pools and spas). Bromine can act as an alternative to chlorine.
The method for bromine is an adaptation of Standard Methods for the Examination of Water and Wastewater, DPD Method.
Chlorine
Chlorine is a widely used disinfectant. In order for it to be effective, the pH of the water should be less than 8.0. The method for chlorine is an adaptation of US EPA Method 330.5, DPD Colorimetric Method.
The method for pH is an adaptation of the Phenol Red Method.
Chlorine Dioxide
Chlorine Dioxide is a powerful and selective disinfectant used in water treatment across a broad pH range.
ide is an adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Ed., 4500 ClO₂ D.
Hydrogen Peroxide
Hydrogen Peroxide is an environmentally friendly, broad spectrum disinfectant. The method for hydrogen peroxide is an adaptation of German Standard Methods for the Examination of Water and Wastewater DIN 38409-15.
Ozone
Ozone is a widely used disinfectant in the treatment of drinking water, wastewater and swimming pools. The method for ozone is the DPD Colorimetric Method.
Further information about the Photometer
Waterproof casing
The casing offers IP67 waterproof protection and floats.
Backlit graphic LCD
The 128 x 64 pixel backlit graphic LCD allows for an intuitive user interface with virtual keys, battery status, and on-screen help and tutorials to guide the user through use of the meter.
Positive locking system
The Hanna positive-locking system ensures cuvettes are placed into the holder in the same position every time.
Virtual Keys
Menu available at the touch of a button
Dedicated HELP button
A dedicated help key provides informational help relating to the current meter operation, and can be used at any stage in the setup or measurement process.
Our advanced LED optical system features
- 8 nm narrow band interference filter that is accurate to ±1 nm and offers a 25% increase in light efficiency over conventional filters
- A reference detector that modulates the voltage to the LED for consistent light output
- A concave focusing lens that reduces errors from imperfections in the cuvette
High efficiency light source
LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability
High quality filters
High tolerance optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received providing higher measurement stability and repeatability.
Stable light source
The internal reference system of Hanna photometers compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light, the readings are fast and reliable between blank (zero) measurements and sample measurements.
Greater light yield
A focusing lens collects all of the light that exits the cuvette, reducing errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.
Large cuvette size
The sample cell of these photometers fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples. The cuvette holder features ridges to protect scratching of the optical path by the cuvette.
Key features
Method and parameter
Chosen parameter and method used is displayed along with the reading.
Multiple measurement methods
Method selection can be accessed by pressing the menu button and selecting Methods. Use the function keys to highlight the desired method.
Auto logging
Log and recall the last 50 measurements.
Built-in reaction timer
Waiting for the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.
CAL Check™ functionality
Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards.
Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings. The CAL Check screen guides the user step-by-step through the validation process and user calibration.
GLP data
Good Laboratory Practice (GLP) shows the date and time of the last user calibration.
Setup options
Setup options for meter personalization include date and time format, language, and enabling the tutorial mode.
Auto-off protection
Supplied with 3 x standard AA batteries provides power 800 measurements to be taken. Our batter preserving auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.
Battery status indicator indicates the amount of battery life left.
Dedicated help
A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.
On-screen tutorial mode with animations
The built in tutorial mode guides users step-by-step through the measurement process.
Error messages
Messages appear on the display alerting to problems such as out of range, light low, light high, ambient temperature out of limits, and battery low.
Warranty
- 2 Years meter
Accessories – replacements to buy separately
Standards
- HI-97107-11 CAL Check™ Validation and Calibration Standards Cuvette Kit.
Reagents
- HI-96795-01 Hydrogen Peroxide reagents for 100 tests
- HI-96795-03 Hydrogen Peroxide reagents for 300 tests
- HI-93701-F Free Chlorine reagent for 300 tests (liquid)
- HI-93701-T Total Chlorine reagent for 300 tests (liquid)
- HI-93703-52 Glycine powder reagent for 100 tests
- HI-93710-01 pH reagent for 100 tests
- HI-93710-03 pH reagent for 300 tests
- HI-93716-01 Bromine reagent for 100 tests
- HI-93716-03 Bromine reagent for 300 tests
- HI-93757-01 Ozone reagent for 100 tests
- HI-93757-03 Ozone reagent for 300 tests
- HI-95771-01 Total Chlorine UHR reagent for 100 tests
- HI-95771-03 Total Chlorine UHR reagent for 300 tests
- HI-96779-01 Chlorine Dioxide (Rapid) reagent for 100 tests
- HI-96779-03 Chlorine Dioxide (Rapid) reagent for 300 tests
Other replacements
- HI-7101422 Blue carrying case
- HI-731318 Cloth for wiping cuvettes (4 pcs.)
- HI-731331 Glass cuvette (4 pcs.)
- HI-731336N Cap for glass cuvette (4 pcs.)
- HI-740034P Cap for 100 mL beaker (10 pcs.)
- HI-740036P 100 mL plastic beaker (10 pcs.)
- HI-740143 1 mL graduated syringe (6 pcs.)
- HI-740144P Pipette tip for 1 mL graduated syringe (10 pcs.)
Specifications
| Bromine | |
|---|---|
| Range | 0.00 to 10.00 mg/L (as Br₂) |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.08 mg/L ±3% of reading at 25 °C (77 °F) |
| Method | Adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method |
| Free and Total Chlorine LR | |
| Range | 0.00 to 5.00 mg/L (as Cl₂) |
| Resolution | 0.01 mg/L |
| Accuracy* | ±0.03 mg/L ±3% of reading at 25 °C (77 °F) |
| Calibration | Adaptation of US EPA Method 330.5, DPD Colorimetric Method |
| Total Chlorine UHR | |
| Range | 0 to 500 mg/L (as Cl₂) |
| Resolution | 1 mg/L |
| Accuracy | ±3 mg/L ±3% of reading at 25 °C (77 °F) |
| Method | Adaptation of Standard Methods for Examination of Water and Wastewater, 20th Edition, 4500-Cl |
| Chlorine Dioxide (Rapid) | |
| Range | 0.00 to 2.00 mg/L (as ClO₂) |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.10 mg/L ±5% of reading at 25 °C (77 °F) |
| Method | Adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, 4500 ClO₂ D |
| Hydrogen Peroxide | |
| Range | 0 to 500 mg/L H₂O₂ |
| Resolution | 1 mg/L |
| Accuracy | ±5 mg/L ±3% of reading at 25 °C (77 °F) |
| Method | Adaptation of DIN 38409-15, German Standard Methods for the Examination of Water and Wastewater |
| Ozone | |
| Range | 0.00 to 2.00 mg/L (as O₃) |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.02 mg/L ±3% of reading at 25 °C (77 °F) |
| Method | DPD Colorimetric Method |
| pH | |
| Range | 6.5 to 8.5 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH of reading at 25 °C (77 °F) |
| Method | Adaptation of the Phenol Red Method |
| Measurement System | |
| Light source | Light Emitting Diode |
| Bandpass filter | 525 nm |
| Bandpass filter bandwidth | 8 nm |
| Bandpass filter wavelength accuracy | ±1.0 nm |
| Light detector | Silicon photocell |
| Cuvette type | Round 24.6 mm diameter (22 mm inside) |
| Additional specifications | |
| Auto logging | 50 readings |
| Display | 128 x 64 pixel black and white LCD with backlight |
| Auto-off | After 15 minutes of inactivity (30 minutes before a READ measurement) |
| Battery type | 1.5 V AA Alkaline (3 pcs.) |
| Battery life | More than 800 measurements (without backlight) |
| Environment | 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable |
| Dimensions | 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0") |
| Weight (with batteries) | 380 g (13.4 oz.) |
| Case ingress protection rating | IP67, floating case |

Frequently Asked Questions
Clear answers to help you choose the right water testing solution with confidence
Which brands of water testing kits do you supply?
Do you provide kits for both home and professional use?
Yes — whether you’re a pool or spa owner, aquarium keeper, utility company, or a university laboratory, we have the right solution for your needs.
Can I arrange servicing or calibration for my photometer?
Absolutely. We also provide servicing and calibration to keep your photometers accurate and reliable.
How quickly do you dispatch orders?
Orders placed before 2:30 pm (Monday–Friday) are dispatched the same day. We also ship on Saturdays for your convenience.
Which couriers do you use for delivery?
We deliver through UPS, DPD, and Royal Mail. You can also choose to upgrade to next-day delivery at checkout.
What is your return policy?
We accept returns within 14 days of delivery provided the items are unused, in their original packaging, and in resalable condition. Please contact our team before returning any items.
Can I place bulk or business orders?
Yes, we welcome bulk, trade, and institutional orders. For tailored pricing or large quantities, please get in touch with us directly.
How can I get help if I’m unsure which kit to buy?
You can call us at 📞 +44 (0)115888 2726 and our team will guide you in choosing the most suitable kit for your needs.