Hanna Instruments HI-97107 Disinfectants Portable Photometer with CAL Check - meter only

Sale price£502.45 Regular price£528.90
Save £26.45

The Hanna HI-97107 Disinfectants Photometer is designed to measure the 7 most important parameters for Legionella control and compliance. Bromine, Free and Total Chlorine Low range, Total Chlorine UHR, Chlorine Dioxide, Hydrogen Peroxide, Ozone and pH are all included and results are displayed directly on the digital display without the need to refer to charts or tables.

HI-97107 Disinfectants Portable Photometer with CAL Check - meter only

This multi-functional photometer is ideal for monitoring in the following industries:

  • Legionella control and compliance for risk assessments, monitoring, and disinfectants
  • Potable Biocides in spas, pools and drinking water
  • Drinking water and wastewater
  • Water tanks
  • Hot and cold water systems
  • Cooling towers and systems
  • Papermills
  • Water feature maintenance
  • Food manufacturing – cleaning lines
  • Holiday Parks
  • Hospitality
  • Hospitals
  • Temporary water supplies eg: events
  • Facilities management

The HI-97107 is a multiparameter portable photometer designed specifically to meet the needs of Legionella compliance and control. Benefiting from Hanna’s years of experience as a manufacturer of analytical instruments it features the Hanna CAL Check™ functionality for maximum accuracy and the unique to Hanna built-in tutorial mode.

The highly accurate optical system is sealed from outside dust, dirt and water with an exclusive positive-locking system to ensure that the cuvettes are placed into the holder in the same position every time.

With the CAL Check™ functionality, users can validate the performance of the instrument at any time and apply a user calibration (if necessary). Hanna Instruments CAL Check™ cuvettes are made with NIST traceable standards.

The built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents and quantities.

About the seven parameters

Bromine

Bromine is a powerful water disinfectant, particularly effective in hot water (treatment of pools and spas). Bromine can act as an alternative to chlorine.

The method for bromine is an adaptation of Standard Methods for the Examination of Water and Wastewater, DPD Method.

Chlorine

Chlorine is a widely used disinfectant. In order for it to be effective, the pH of the water should be less than 8.0. The method for chlorine is an adaptation of US EPA Method 330.5, DPD Colorimetric Method.

The method for pH is an adaptation of the Phenol Red Method.

Chlorine Dioxide

Chlorine Dioxide is a powerful and selective disinfectant used in water treatment across a broad pH range.

ide is an adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Ed., 4500 ClO₂ D.

Hydrogen Peroxide

Hydrogen Peroxide is an environmentally friendly, broad spectrum disinfectant. The method for hydrogen peroxide is an adaptation of German Standard Methods for the Examination of Water and Wastewater DIN 38409-15.

Ozone

Ozone is a widely used disinfectant in the treatment of drinking water, wastewater and swimming pools. The method for ozone is the DPD Colorimetric Method.

About the Photometer

Waterproof casing

The casing offers IP67 waterproof protection and floats.

Backlit graphic LCD

The 128 x 64 pixel backlit graphic LCD allows for an intuitive user interface with virtual keys, battery status, and on-screen help and tutorials to guide the user through use of the meter.

Positive locking system

The Hanna positive-locking system ensures cuvettes are placed into the holder in the same position every time.

Virtual Keys

Menu available at the touch of a button

Dedicated HELP button

A dedicated help key provides informational help relating to the current meter operation, and can be used at any stage in the setup or measurement process.

Our advanced LED optical system features

  • 8 nm narrow band interference filter that is accurate to ±1 nm and offers a 25% increase in light efficiency over conventional filters
  • A reference detector that modulates the voltage to the LED for consistent light output
  • A concave focusing lens that reduces errors from imperfections in the cuvette

High efficiency light source

LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.

Light source

High quality filters

High tolerance optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received providing higher measurement stability and repeatability.

Stable light source

The internal reference system of Hanna photometers compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light, the readings are fast and reliable between blank (zero) measurements and sample measurements.

Greater light yield

A focusing lens collects all of the light that exits the cuvette, reducing errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.

Large cuvette size

The sample cell of these photometers fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples. The cuvette holder features ridges to protect scratching of the optical path by the cuvette.

Key features

Method and parameter

Chosen parameter and method used is displayed along with the reading.

Multiple measurement methods

Method selection can be accessed by pressing the menu button and selecting Methods. Use the function keys to highlight the desired method.

Auto logging

Log and recall the last 50 measurements.

Built-in reaction timer

Waiting for the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.

CAL Check™ functionality

Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards.

Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings. The CAL Check screen guides the user step-by-step through the validation process and user calibration.

GLP data

Good Laboratory Practice (GLP) shows the date and time of the last user calibration.

Setup options

Setup options for meter personalization include date and time format, language, and enabling the tutorial mode.

Auto-off protection

Supplied with 3 x standard AA batteries provides power 800 measurements to be taken. Our batter preserving auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.

Battery status indicator indicates the amount of battery life left.

Dedicated help

A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.

On-screen tutorial mode with animations

The built in tutorial mode guides users step-by-step through the measurement process.

Error messages

Messages appear on the display alerting to problems such as out of range, light low, light high, ambient temperature out of limits, and battery low.

HI-97107 What's included:

Each HI-97107 is delivered is supplied with:

  • Sample cuvette with cap (2 pcs.)
  • Plastic stopper (2 pcs.)
  • 1.5V AA alkaline battery (3 pcs.)
  • Battery safety insert
  • Quick reference guide with instructions for manual download and instrument quality certificate.

Warranty

  • 2 Years meter

Accessories – to buy separately

Standards

  • HI-97107-11 CAL Check™ Validation and Calibration Standards Cuvette Kit.

Reagents

  • HI-96795-01 Hydrogen Peroxide reagents for 100 tests
  • HI-96795-03 Hydrogen Peroxide reagents for 300 tests
  • HI-93701-F Free Chlorine reagent for 300 tests (liquid)
  • HI-93701-T Total Chlorine reagent for 300 tests (liquid)
  • HI-93703-52 Glycine powder reagent for 100 tests
  • HI-93710-01 pH reagent for 100 tests
  • HI-93710-03 pH reagent for 300 tests
  • HI-93716-01 Bromine reagent for 100 tests
  • HI-93716-03 Bromine reagent for 300 tests
  • HI-93757-01 Ozone reagent for 100 tests
  • HI-93757-03 Ozone reagent for 300 tests
  • HI-95771-01 Total Chlorine UHR reagent for 100 tests
  • HI-95771-03 Total Chlorine UHR reagent for 300 tests
  • HI-96779-01 Chlorine Dioxide (Rapid) reagent for 100 tests
  • HI-96779-03 Chlorine Dioxide (Rapid) reagent for 300 tests

Other

  • HI-7101422 Blue carrying case
  • HI-731318 Cloth for wiping cuvettes (4 pcs.)
  • HI-731331 Glass cuvette (4 pcs.)
  • HI-731336N Cap for glass cuvette (4 pcs.)
  • HI-740034P Cap for 100 mL beaker (10 pcs.)
  • HI-740036P 100 mL plastic beaker (10 pcs.)
  • HI-740143 1 mL graduated syringe (6 pcs.)
  • HI-740144P Pipette tip for 1 mL graduated syringe (10 pcs.)

Specifications

Bromine
Range 0.00 to 10.00 mg/L (as Br₂)
Resolution 0.01 mg/L
Accuracy ±0.08 mg/L ±3% of reading at 25 °C (77 °F)
Method Adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method
Free and Total Chlorine LR
Range 0.00 to 5.00 mg/L (as Cl₂)
Resolution 0.01 mg/L
Accuracy* ±0.03 mg/L ±3% of reading at 25 °C (77 °F)
Calibration Adaptation of US EPA Method 330.5, DPD Colorimetric Method
Total Chlorine UHR
Range 0 to 500 mg/L (as Cl₂)
Resolution 1 mg/L
Accuracy ±3 mg/L ±3% of reading at 25 °C (77 °F)
Method Adaptation of Standard Methods for Examination of Water and Wastewater, 20th Edition, 4500-Cl
Chlorine Dioxide (Rapid)
Range 0.00 to 2.00 mg/L (as ClO₂)
Resolution 0.01 mg/L
Accuracy ±0.10 mg/L ±5% of reading at 25 °C (77 °F)
Method Adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, 4500 ClO₂ D
Hydrogen Peroxide
Range 0 to 500 mg/L H₂O₂
Resolution 1 mg/L
Accuracy ±5 mg/L ±3% of reading at 25 °C (77 °F)
Method Adaptation of DIN 38409-15, German Standard Methods for the Examination of Water and Wastewater
Ozone
Range 0.00 to 2.00 mg/L (as O₃)
Resolution 0.01 mg/L
Accuracy ±0.02 mg/L ±3% of reading at 25 °C (77 °F)
Method DPD Colorimetric Method
pH
Range 6.5 to 8.5 pH
Resolution 0.1 pH
Accuracy ±0.1 pH of reading at 25 °C (77 °F)
Method Adaptation of the Phenol Red Method
Measurement System
Light source Light Emitting Diode
Bandpass filter 525 nm
Bandpass filter bandwidth 8 nm
Bandpass filter wavelength accuracy ±1.0 nm
Light detector Silicon photocell
Cuvette type Round 24.6 mm diameter (22 mm inside)
Additional specifications
Auto logging 50 readings
Display 128 x 64 pixel black and white LCD with backlight
Auto-off After 15 minutes of inactivity (30 minutes before a READ measurement)
Battery type 1.5 V AA Alkaline (3 pcs.)
Battery life More than 800 measurements (without backlight)
Environment 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable
Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0")
Weight (with batteries) 380 g (13.4 oz.)
Case ingress protection rating IP67, floating case