Hanna Instruments HI-6522 pH/ORP/ISE + EC Multiparameter Modular Benchtop Meter

Sale price£1,282.00 Regular price£1,349.40
Save £67.40

HI-6522 pH/ORP/ISE + EC Multiparameter Modular Benchtop Meter

This kit includes the necessary modules and probes to measure pH, temperature and conductivity, providing everything needed to start measuring straight out of the box. This advanced multimeter features WiFi and ethernet connectivity. 

  EC
 ISE
 ORP
 pH

The HI-6522 Kit for the HI-6000 includes the HI-6000 modular laboratory meter system, a HI-6000-2 pH/ISE module and a HI-6000-3 EC module. Also included is the HI-1131B pH electrodeHI-7662-TW temperature probe and HI-7631233 EC and resistivity probe. This kit includes everything needed for the accurate measurement of EC and pH, including a calibration solution starter set for EC and pH.

HI-6000 is a fully flexible measurement platform that can be customised according to the user’s application needs. Designed and developed using the latest generation technologies, it gives complete control over measurements.

This kit is compatible with a wide range of Hanna Instruments electrodes for ISE measurement. For advice on the best electrodes for your needs speak to our in-house specialists directly.

Six different pre-built kits are available for the HI-6000 multimeter, including the modules and electrodes required for laboratory-grade measurement:

Specification:
HI-6522-02 pH/ORP/ISE + EC Kit
Range -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH
Resolution 0.1 pH; 0.01 pH; 0.001 pH
Accuracy ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)
Temperature Compensation Automatic or manual
mV
Range -2000.0 mV to 2000.0 mV
Resolution 1 mV; 0.1 mV
Accuracy ±0.2 mV ±1 last significant digit
ISE
Range 1 x 10-6 to 9.99 x 1010 concentration
Resolution 1; 0.1; 0.01; 0.001 concentration
Accuracy ±0.5% (monovalent ions); ±1% (divalent ions)
Calibration Automatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards
Temperature
Range -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K
Resolution 0.1 °C / 0.1 °F / 0.1 K
Accuracy ±0.2 °C / ±0.4 °F / ±0.2 K
Relative mV offset range ±2000.0 mV
pH Calibration
Calibration points Up to 5
Type Automatic; Semiautomatic; Manual
Standard buffers Hanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45
Custom buffers Up to 5
Custom group Up to 5
1st calibration point Offset or Points (user setting)
Temperature User Calibration Single point, adjustable; Isopotential point: -2.000 to 20.000pH
Conductivity
Range 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm;
1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm
Resolution 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
Accuracy ±1 % of reading ±0.010 μS/cm, whichever is greater
Cell Constant 0.0500 to 200.00 /cm
Calibration Type automatic; manual
Calibration points Single
Multiple
Calibration solutions 84.00 μS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm
Temperature Compensation Linear, natural, standard, disabled
Reference Temperature Range: 5.0 to 30.0˚C (41.0 to 86.0˚C
Resolution 0.1˚C / 0.1˚F
Temperature Coefficient 0.00 to 10.00%/˚C
Resistivity
Range 1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm
Resolution 0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm
Accuracy ±1 % of reading or ±1 Ω・cm, whichever is greater
Total Dissolved Solids (TDS)
Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)
Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt
Accuracy ±1 % of reading or ±0.01 ppm, whichever is greater
Salinity
Range 0.00 to 42.00 PSU - Practical Scale
0.00 to 80.00 ppt - Natural Sea Water
0.0 to 400.0 % - Percent Scale
Resolution 0.01 for Practical Scale / Natural Sea Water
0.1 % for Percent Scale
Accuracy ±1 % of reading
Calibration 1 point for Percent Scale, using 100% salinity calibration solution
Temperature
Range −20.0 to 120.0 °C; -4.0 to 248.0˚F; 253.0 to 393.0 K
Resolution 0.1 °C; 0.1 °F; 0.1 K
Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K
Calibration Single point, adjustable

Frequently Asked Questions

Clear answers to help you choose the right water testing solution with confidence