

Hanna Instruments HI-2630 Conductivity Benchtop meter
HI-2630 benchtop meter enables fast, accurate measurements of conductivity, TDS, and temperature utilising Hanna digital probes – HI-763100 Digital Conductivity electrode with temperature sensor. Ideal for laboratories, classrooms and general industry.
The HI-2630 architecture brings together Hanna’s visionary design capabilities, integrated production, and world class research and development.
HI-2630 Conductivity Benchtop meter
HI-2630 benchtop meter enables fast, accurate measurements utilising the Hanna Instruments digital electrode for conductivity (HI-763100) which includes an integral temperature sensor. Each digital electrode has a unique serial number and the parameter that it measures is automatically identified by the meter.
The intuitive design simplifies configuration, calibration, measurement, data logging and transfer of data to a USB thumb drive or computer.
The meter has a large display with capacitive keys which features a 5.5” (14 cm) LCD. The large display provides a 130 ° wide viewing angle.
Main feature points
- Automatic parameter recognition
- EC choice of measurement unit: Conductivity: µS/cm, mS/cm
- TDS - ppm (mg/L), g/L
- Adjustable resolution for EC measurements
- Dedicated GLP key
- Simplified data transfer to a PC
- Internal clock and date
Key Features
Digital probe input - simply connect each probe via the 3.5 mm jack, Digital Smart Electrodes are automatically recognised.
Clear, full text readout
- The HI-2630 presents clear, detailed text prompts at the bottom section of the screen.
GLP - The sensor retains data from the most recent calibration, including date, time, and buffers utilised.
Capacitive touch keypad - HI-2630 features sensitive capacitive touch buttons for accurate keystrokes for navigating menus and screens. Since they are part of the screen, the buttons can never get clogged with sample residue.
Easy to read LCD - HI-2630 features a 5.5” (14 cm) LCD display that you can clearly view from over 5 m (16.4’). The large display, with its wide 130° viewing angle, provides one of the easiest to read LCDs in the industry.
What's included:
- HI-763100 digital conductivity electrode
- HI-764026 Electrode holder with the following accessories: base plate with integrated pivot pin; cable holder clip, attached
- 12880 µS/cm calibration solution, x 2 sachets
- 1413 µS/cm calibration solution, x 4 sachets
- 5000 µS/cm calibration solution, x 2 sachets
- Electrode rinse solution x 2 sachets
- HI-920018 - 1.5m USB-C to USB-C cable
- USB-C power adapter
- Instrument quality certificate
- Probe / electrode quality certificate
- Battery safety insert
- Quick reference guide with QR code for instruction manual download
Warranty - Meter has 2 years. 6 months from date of purchase for electrodes and probes
More accessories to buy separately
Electrodes
- HI-763100 Digital EC / temperature probe
More solutions to buy separately
Conductivity solutions
- HI-7030L 12880 µS/cm calibration solution, 500 mL
- HI-7030M 12880 µS/cm calibration solution, 230 mL
- HI-7031L 1413 µS/cm calibration solution, 500 mL
- HI-7031M 1413 µS/cm calibration solution, 230 mL
- HI-7033L 84 µS/cm calibration solution, 500 mL
- HI-7033M 84 µS/cm calibration solution, 230 mL
- HI-7034L 80000 µS/cm calibration solution, 500 mL
- HI-7034M 80000 µS/cm calibration solution, 230 mL
- HI-7035L 111800 µS/cm calibration solution, 500 mL
- HI-7035M 111800 µS/cm calibration solution, 230 mL
- HI-7039L 5000 µS/cm calibration solution, 500 mL
- HI-7039M 5000 µS/cm calibration solution, 230 mL
- HI-7037L 100% NaCl sea water standard solution, 500 mL
Other useful accessories
- HI-764026 Electrode holder for HI-2600 family
Models in the series
HI-2600 pH, EC, DO Benchtop Meter with Data Logging
HI-2620 pH and ORP Benchtop Meter
HI-2621 pH and ORP Benchtop Meter with Data Logging
HI-2630 EC & TDS Benchtop Meter
HI-2631 EC, TDS and Salinity Benchtop Meter with Data Logging
HI-2640 Dissolved Oxygen Benchtop Meter
HI-2641 Dissolved Oxygen Benchtop Meter with Data Logging
Specifications
| EC - using HI-763100 four-ring conductivity probe | |
|---|---|
| EC Range | 0.00 to 29.99 µS/cm;30.0 to 299.9 µS/cm;300 to 2999 µS/cm;3.00 to 29.99 mS/cm;30.0 to 200.0 mS/cm;up to 500.0 mS/cm,and absolute conductivity (TDS) is the conductivity value without temperature compensation |
| Resolution | 0.01 µS/cm;0.1 µS/cm;1 µS/cm;0.01 mS/cm;0.1 mS/cm |
| Accuracy (@25°C) | ±1% of reading (±0.5 µS/cm or 1 digit, whichever is greater) |
| Calibration | Cell factor calibration; six standards available: 84µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 118.8 mS/cm, one point offset: 0.00 µS/cm |
| Temperature Compensation | Automatic, -5 to 100.0°C; NoTC, can be selected to measure absolute conductivity |
| Temperature Coefficient | 0.00 to 6.00%/°C (for EC and TDS only), default value is 1.90%/°C |
| TDS - using HI-763100 four-ring conductivity probe | |
| TDS Range | 0.00 to 14.99 mg/L (ppm);15.0 to 149.9 mg/L (ppm);150 to 1499 mg/L (ppm);1.50 to 14.99 g/L;15.0 to 100.0 g/L;up to 400.0 g/L absolute TDS using 0.80 conversion factor |
| Resolution | 0.01 mg/L (ppm);0.1 mg/L (ppm);1 (ppm);0.01 g/L;0.1 g/L |
| Accuracy (@25°C) | ±1% of reading (±0.03 ppm or 1 digit, whichever is greater) |
| Calibration | through EC calibration |
| TDS Factor in Standard Mode | 0.40 to 0.80 (default value is 0.50) |
| Temperature | |
| Temperature Range | -20.0 to 120.0 °C |
| Resolution | 0.1°C |
| Accuracy | ±0.5°C |
| Additional Specifications | |
| PC Interface | USB-C |
| Storage Interface | USB-C |
| Power supply | USB Type C (5 VDC; 500mA) |
| Environment | 0 to 50˚C; Maximum 95% RH non-condensing |
| Dimensions | 205 x 160 x 77 mm |
| Weight | Approximately 0.85 kg |

Frequently Asked Questions
Clear answers to help you choose the right water testing solution with confidence
Which brands of water testing kits do you supply?
Do you provide kits for both home and professional use?
Yes — whether you’re a pool or spa owner, aquarium keeper, utility company, or a university laboratory, we have the right solution for your needs.
Can I arrange servicing or calibration for my photometer?
Absolutely. We also provide servicing and calibration to keep your photometers accurate and reliable.
How quickly do you dispatch orders?
Orders placed before 2:30 pm (Monday–Friday) are dispatched the same day. We also ship on Saturdays for your convenience.
Which couriers do you use for delivery?
We deliver through UPS, DPD, and Royal Mail. You can also choose to upgrade to next-day delivery at checkout.
What is your return policy?
We accept returns within 14 days of delivery provided the items are unused, in their original packaging, and in resalable condition. Please contact our team before returning any items.
Can I place bulk or business orders?
Yes, we welcome bulk, trade, and institutional orders. For tailored pricing or large quantities, please get in touch with us directly.
How can I get help if I’m unsure which kit to buy?
You can call us at 📞 +44 (0)115888 2726 and our team will guide you in choosing the most suitable kit for your needs.