Hanna Instruments HI-1217-1 General purpose pH electrode

Sale price£192.56 Regular price£202.70
Save £10.14

Recommended for use with the HI-8314-1 pH meter. This instrument is ideal for applications that require a custom calibration point. Manual calibration can be extremely useful in order to achieve better accuracy.

Special pH and ORP Electrodes

Tips for the most accurate measurements

Keep Electrode Hydrated

It is advisable for pH electrodes to be kept in a storage solution when not in use. Placing the electrode in a small glass filled with storage solution is suitable. An option for pocket meters is to place a small piece of sponge in the meter’s cap and pour storage solution into the cap to wet the sponge. Pouring off any excess solution beforehand, the cap can then be placed on the meter.

If a storage solution is not available, the next best option is to use pH 4.01 buffer (pH 7.01 is also suitable to a lesser extent).

Clean electrodes before use

Clean the junction of your electrodes once a day or at least once a week to prevent junction clogging and to maintain accuracy. Immerse the electrode in the proper cleaning solution for at least 15 to 20 minutes. Hanna offers a wide range of cleaning solutions for general purpose and specific applications.

Replace electrodes once a year

If your electrode takes too long to stabilise a reading, or readings fluctuate wildly, it is most likely time to replace the electrode. The typical life span of any pH electrode is from 6 months to 1.5 years.

Additional Tips

  • Calibration and storage solutions should be changed regularly (i.e. monthly).
  • Calibrate the meter often if a high degree of accuracy is required.
  • Remember that the calibration is as only as good the buffer being used (i.e. old or contaminated buffer solutions may not have the same value on the label).
  • Single-use calibration sachets, as opposed to bottles, ensure that your buffer solution is always fresh.
  • If the meter takes an unusually long time to get a stable reading, the junction may be clogged.
  • Rinse the probe with purified water after each use.

Specifications

SKU HI-1217-1
Description pH electrode
Reference single, Ag/AgCl
Junction / Flow Rate ceramic, single
Electrolyte gel
Max Pressure 2 bar
Range pH: 0 to 13
Recommended Operating Temp. 0 to 70°C (32 to 158°F)
Glass Type GP (general purpose)
Tip /Shape spheric (dia: 5.0 mm)
Temperature Sensor yes
Amplifier yes
Body Material PEI
Cable type coaxial; 1 m
Recommended Use general purpose
Connection HI-1217-1 DIN**
** Recommended for use with HI-8314-1 pH meter