Hanna Instruments-83305-02 Multi-parameter Photometer & pH Meter for Boiling and Cooling towers

Hanna InstrumentsSKU: HI-83305-02
filler

Price:
Sale price£754.27

taxes & shipping calculated at checkout

Stock:
Re-stocking soon, contact us to confirm date

Description

One meter can be used for both photometric and pH measurements. The meter has 30 different programmed methods measuring 18 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves.

Hanna Instruments-83305-02 Boiler and Cooling Tower Photometer with pH digital input


Advanced optical system - Unparalleled performance from a benchtop photometer


To save valuable benchtop space, the Hanna Instruments-83305 doubles as a professional pH meter with its digital pH/temperature electrode input. Suitable for use in boiling and cooling tower applications, parameters specific to boiling and cooling towers include oxygen scavengers and silica which are important for maintaining equipment.


To save valuable laboratory benchtop space, the Hanna Instruments-83305 doubles as a professional pH meter with its digital pH/temperature electrode input.


This photometer features an innovative optical system that uses LEDs, narrow band interference filters, a focusing lens, plus a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source which ensures accurate and repeatable photometric readings every time.


Specifically designed for use with boilers and cooling towers, the Hanna Instruments-83305 is a comprehensive way to maintain precise water conditions in systems. Problems such as corrosion, deposition, and microbial growth can occur if these key parameters, such as oxygen scavengers and silica, aren't maintained. Oxygen scavengers are added to remove residual dissolved oxygen in boiler feed water that can cause corrosion in a steam generating plant. It is important that levels of oxygen scavengers be routinely checked to prevent against corrosion and ensure that equipment is working efficiently. Boiler water maintenance is necessary to prevent or control deposit formation as seen with silica. Silica contamination can reduce system efficiency and increase maintenance of equipment due to scaling.


A digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built-in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built-in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.


The Hanna Instruments-83305 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.


Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability, the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.



Key features:



  • Backlit 128 x 64 Pixel Graphic Liquid Crystal Display

  • Built-in Reaction Timer for Photometric Measurements

  • Absorbance mode - concentration versus absorbance

  • Units of Measurement plus chemical form displayed

  • Result conversion at the touch of a button

  • Cuvette cover

  • pH and temperature measurement with a single probe

  • Good Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability

  • pH CAL Check alerts user to potential problems during the calibration process

  • Data Logging - Up to 1000 photometric and pH readings can be stored.

  • Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.

  • Battery Status Indicator

  • Error Messages



High Efficiency LED Light Source


An LED light source offers superior performance compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue/violet light output.



High Quality Narrow Band Interference Filters


The narrow band interference filter not only ensure greater wavelength accuracy (+/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.



Reference Detector for a Stable Light Source


A beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.



Large Cuvette Size


The sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.



Focusing Lens for Greater Light Yield


Adding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette