Hanna Instruments HI-715-25 Reagents for HI-715 Ammonia Medium Range Checker HC

Hanna InstrumentsSKU: HI-715-25
filler

Price Excluding VAT:
Sale price£32.55

shipping calculated at checkout

Stock:
Re-stocking soon, contact us to confirm date

Description

HI-715-25 Reagents for HI-715 Ammonia Medium Range Checker HC

The HI-715-25 are the replacement reagents for the HI-715 Ammonia Medium Range Checker® HC.

 25 tests

The HI-715-25 are high-quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Ammonia Medium Range Checker® HC. These reagents follow the Nessler Method in which the reaction between ammonia and reagents causes a yellow tint in the sample.

By simply adding 4 drops from each bottle of the HI-715-25 reagent set to the sample, the reaction will take place and the HI-715 will determine the concentration from the colour that is produced. The results will be displayed in ppm (mg/L) of ammonia-nitrogen (NH3-N). These reagents are designed to be used with samples that have an expected range of 0.00 to 9.99 ppm ammonia-nitrogen. To convert the reading to ppm of ammonia (NH3) multiply the result by 1.214.

Please download the Safety Datasheet(s) which provide more detail on the reagents before use; click on the link in the “safety data sheets” paragraph below.

 

Tip for an accurate measurement

It is important that the sample does not contain any debris.

Whenever the cuvette is placed into the measurement cell, it must be dry outside and completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI-731318 or a lint-free cloth prior to insertion.

Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette.

Do not let the reacted sample stand for too long after reagent is added, or accuracy will be lost.

After the reading, it is important to discard the sample immediately, otherwise the glass might become permanently stained.

 

Four steps. One click. Instant Readout.

1. ‘Zero’ the Checker®HC with your vial inside

2. Place a 10ml water sample into the vial and add your reagent

3. Place your vial into your Checker®HC

4. Press the button and read the results

 

Also available: HI-715-11 calibration set.

 