{"product_id":"hanna-instruments-hi-98294-gps-multiparameter-portable-ph-ec-ise-turbidity-do-meter","title":"Hanna Instruments HI-98294 GPS Multiparameter Portable pH, EC, ISE, Turbidity, DO Meter","description":"\u003cp\u003eHI-98294 GPS Multiparameter Portable pH, EC, ISE, Turbidity, DO Meter\u003c\/p\u003e \u003cp\u003eHI-98294 is a portable logging multiparameter system (meter and probe) that monitors up to 14 different water quality parameters (7 measured and 7 calculated) such as pH, ORP, turbidity, dissolved oxygen, conductivity, chloride, nitrate, ammonium and temperature.\u003c\/p\u003e \u003cp\u003eEach parameter is fully configurable. HI-98294 has a graphic, backlit display that automatically sizes the digits to fit the screen with on screen graphing capability.\u003c\/p\u003e \u003cp\u003eHI-98294 features an internal 12-channel GPS receiver \/ antenna module that guarantees a position accuracy of 10 m (30 ft). GPS information can be transferred to a PC and can be viewed using GPS mapping software. Clicking on visited locations, using a mapping software, displays the measurement information.\u003c\/p\u003e \u003cp\u003eThe GPS coordinates are shown on the LCD together with up to 10 measurement parameters, which are recorded with logged data. A 3-bar antenna indicator, in the bottom right corner of the LCD, indicates GPS signal strength. The multi-sensor probe features an internal temperature sensor and a removable protective shield.\u003c\/p\u003e \u003cp\u003eEach meter comes with a protective rubber boot and meets IP67 standard (30 minutes immersion at 1 meter depth). The multi-sensor probe is totally sealed against water and dust, and meets IP68 standard (continuous immersion in water).\u003c\/p\u003e \u003ch3\u003eMain features\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eMonitors up to 14 different water quality parameters\u003c\/li\u003e \u003cli\u003eRugged, water-resistant meter and waterproof probe\u003c\/li\u003e \u003cli\u003eField-replaceable sensors with auto recognition\u003c\/li\u003e \u003cli\u003eInstantaneous conductivity and turbidity measurements\u003c\/li\u003e \u003cli\u003eBuilt-in barometer for percent saturation and DO concentration compensation\u003c\/li\u003e \u003cli\u003eGood Laboratory Practice feature, the last 5 calibrations are automatically stored\u003c\/li\u003e \u003cli\u003eGraphical display of logged data on backlit LCD screen\u003c\/li\u003e \u003cli\u003eLog-on-demand and automatic logging on meter for all parameters\u003c\/li\u003e \u003cli\u003eQuick calibration feature to provide single point calibration for pH, conductivity, and dissolved oxygen with one solution\u003c\/li\u003e \u003cli\u003eProbe shipped with sensors installed\u003c\/li\u003e \u003cli\u003eWaterproof Quick Connect DIN connection between meter and probe\u003c\/li\u003e \u003cli\u003eUSB-C interface for PC communication\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe HI-98294 system is easy to setup and use. The built-in tutorial mode guide users step-by-step through sensor preparation, installation, maintenance, and calibration processes. The meters can log data that can be easily downloaded as a .csv file (or graph) to a type-C, USB flash drive.\u003c\/p\u003e \u003ch3\u003eRugged Custom Carrying Case\u003c\/h3\u003e \u003cp\u003eThe HI-98294 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all components.\u003c\/p\u003e \u003ch3\u003eWhat's included:\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-7698294\/4 Multi-sensor probe\u003c\/li\u003e \u003cli\u003e1.5V AA alkaline batteries (4 pcs.)\u003c\/li\u003e \u003cli\u003eHI-7698194-1 pH \/ ORP sensor (pre-installed on the probe)\u003c\/li\u003e \u003cli\u003eHI-7698594-4 EC \/ Turbidity sensor (pre-installed on the probe)\u003c\/li\u003e \u003cli\u003eHI-7698194-2 Galvanic DO sensor (pre-installed on the probe)\u003c\/li\u003e \u003cli\u003eHI-7698296 Long protective probe shield\u003c\/li\u003e \u003cli\u003eHI-7698293 Long calibration beaker\u003c\/li\u003e \u003cli\u003eHI-9828-20 Quick calibration standard solution (230 mL)\u003c\/li\u003e \u003cli\u003eHI-9829-16 0 FNU calibration solution (230 mL)\u003c\/li\u003e \u003cli\u003eHI-9829-17 20 FNU calibration solution (230 mL)\u003c\/li\u003e \u003cli\u003eHI-9829-18 200 FNU calibration solution (230 mL)\u003c\/li\u003e \u003cli\u003eHI-710036 Protective rubber boot (fitted on meter)\u003c\/li\u003e \u003cli\u003eHI-920019 USB-C to USB-C cable\u003c\/li\u003e \u003cli\u003eProbe maintenance kit includes: DO galvanic membranes, o-rings for DO sensor, o-rings for probe, electrolyte solution for DO sensor, 5 mL syringe, scouring pad, sensor-socket protection, hex key, small brush, sachet with silicone grease\u003c\/li\u003e \u003cli\u003eInstrument quality certificate\u003c\/li\u003e \u003cli\u003eSensors and probe quality certificates\u003c\/li\u003e \u003cli\u003eQuick reference with QR code for manual download Warranty 2 Years meter 6 months sensors and probes\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003epH \/ mV\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH \/ ±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH \/ ±3.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eOne-point Quick Calibration using HI-9828-20; up to three points using pH 4.01, 6.86, 7.01, 9.18, 10.01) standard buffers or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eORP\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (evaluated with a calibrated system at ambient temperature)\u003c\/td\u003e\n\u003ctd\u003e±10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic at one custom point (relative mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eEC\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm0 to 400 mS\/cm (absolute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003emanual: 1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm; automatic: 1 μS\/cm from 0 to 9999 μS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm; automatic (mS\/cm): 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (evaluated with a calibrated system at ambient temperature)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 μS\/cm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eOne-point Quick Calibration using HI-9828-20; One point, with six standard solutions (84 μS\/cm, 1413 μS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTDS\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 400000 ppm (mg\/L) (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003emanual: 1 ppm (mg\/L); 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L); automatic: 1 ppm (mg\/L) from 0 to 9999 ppm (mg\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L); automatic ppt (g\/L): 0.001 ppt (g\/L) from 0.000 to 9.999 ppt (g\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 ppm (mg\/L) whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eResistivity\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm depending on resistivity reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 Ω•cm; 0.1 k Ω•cm; 0.0001 M Ω•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eBased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eSalinity\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2% of reading or ±0.01 PSU whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eOne point, using a custom solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eSeawater Sigma\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTurbidity\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0 to 99.9 FNU; 100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 FNU from 0.0 to 99.9 FNU1 FNU from 100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 FNU or ±2% of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic up to 3 points at 0, 20 and 200 FNU or custom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDissolved Oxygen\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0% saturation; 0.00 to 50.00 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1% saturation; 0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (evaluated with a calibrated system at ambient temperature)\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading from 0.0-200.0% saturation;±5% of reading from 200.0-500.0 % saturation;±1.5% of reading from 0.00-20.00 mg\/L;±5% of reading from 20.00-50.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eOne point, quick calibration in water saturated air; One or two-point at 100% and 0%; One point using a custom solution, % saturation or mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic: 450 to 850 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAtmospheric Pressure\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mm Hg within ±15°C from calibration temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-5.00 to 50.00°C; 23.00 to 122.00°F; 268.15 to 323.15K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01°C; 0.01°F; 0.01K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.15°C; ±0.27°F; ±0.15K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAmmonium-Nitrogen\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.02 to 200.00 ppm Am (as NH4+-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm to 1.00 ppm; 0.1 ppm to 200.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% of reading or 2ppm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point, 10 ppm and 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eChloride\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.6 to 200.00 ppm Cl (as Cl-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm to 1 ppm; 0.1 ppm to 200.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% of reading or 2ppm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point, 10 ppm and 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eNitrate-Nitrogen\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.62 to 200.00 ppm N (as NO3--N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% of reading or 2ppm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point, 10 ppm and 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAdditional Specifications\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from -5 to 50°C (23 to 122°F) 268.15 to 323.15K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eInterval logging 50,000 records or log-on-demand (all parameters) 15,000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Interval\u003c\/td\u003e\n\u003ctd\u003eone second to three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGPS\u003c\/td\u003e\n\u003ctd\u003eyes, 12 channel receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB-C (HOST) functions – Mass storage host; USB-C (device) functions – Mass storage device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA alkaline batteries (4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eApproximately 40 hours with logging every 1 second, all parameters enabled and GPS on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \/ Weight\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) \/ 435g (13.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eProbe Specification – HI-7698294\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Inputs\u003c\/td\u003e\n\u003ctd\u003epH, pH\/ORP Dissolved Oxygen EC, EC\/Turbidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Environment\u003c\/td\u003e\n\u003ctd\u003eFresh, brackish, seawater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaterproof Protection\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 70.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum depth\u003c\/td\u003e\n\u003ctd\u003e20m (66 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (without cable)\u003c\/td\u003e\n\u003ctd\u003e342mm; 46mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with sensors and batteries)\u003c\/td\u003e\n\u003ctd\u003e570g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable specification\u003c\/td\u003e\n\u003ctd\u003eMultistrand-multiconductor shielded cable with internal strength member rated for 90kg intermittent use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted materials\u003c\/td\u003e\n\u003ctd\u003eBody – ABSThreads – NylonShield – ABS\/316 SSTemperature Probe – 316 SSO-rings - EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eSensor Specifications:\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-7698194-1 pH\/ORP sensor\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement type\u003c\/td\u003e\n\u003ctd\u003epH, mV (pH\/ORP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 12.00 pH; ±600.0mV (pH); ±2000.0mV (ORP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour Code\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials\u003c\/td\u003e\n\u003ctd\u003eGlass tip (pH) and ORP (Platinum), Wick junction, PEI body, electrolyte gel and double reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance solution\u003c\/td\u003e\n\u003ctd\u003eHI-70300 storage solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e118 x 15mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-7698594-4 EC\/Turbidity sensor\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement unit\u003c\/td\u003e\n\u003ctd\u003eµS\/cm, mS\/cm, FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e0 to 200.0 mS\/cm0.0 to 400 mS\/cm (absolute)0.0 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour Code\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials\u003c\/td\u003e\n\u003ctd\u003eBody: ABS\/EPOXY; Electrodes – Stainless Steel (AISI 316)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance solution\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e135 x 35mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-7698194-2 DO sensor\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement unit\u003c\/td\u003e\n\u003ctd\u003eDO (% saturation and concentration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0 %0.00 to 50.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-5 to 55˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour Code\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials\u003c\/td\u003e\n\u003ctd\u003eTip – cat\/an: Ag\/Zn; junction – membrane HDPE; Body - ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance solution\u003c\/td\u003e\n\u003ctd\u003eHI-7042S (DO electrolyte)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e99 x 17mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640110653813,"sku":"HI-98294","price":2090.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-98294-gps-multiparameter-portable-ph-ec-ise-turbidity-do-meter_74bb1384-1946-4c7b-a79d-7cc5f5e32427.jpg?v=1791581608","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-98294-gps-multiparameter-portable-ph-ec-ise-turbidity-do-meter","provider":"Test All Water","version":"1.0","type":"link"}