{"product_id":"hanna-instruments-hi-9829-multiparameter-ph-ise-ec-do-turbidity-waterproof-meter-gps-option-available","title":"Hanna Instruments HI-9829 Multiparameter pH\/ISE\/EC\/DO\/Turbidity Waterproof Meter (GPS option available)","description":"\u003cp\u003eThe HI-9829 is a highly customisable piece of equipment. Please telephone Hanna on 01525 850855 to discuss your requirements and to get a price as prices start FROM the price listed below. This price is for the meter only. The probe, plus all sensors and solutions, must be purchased separately.\u003c\/p\u003e\u003cp\u003eThe HI-9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters.\u003c\/p\u003e \u003cp\u003eThe microprocessor based multi-sensor probe (buy separately) allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature.\u003c\/p\u003e \u003cp\u003eThe probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use.\u003c\/p\u003e \u003cp\u003eThe HI-9829 is highly customisable and all necessary accessories, including the probe and sensors, carrying case, and solutions must be purchased separately.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eBuilt in GPS Receiver\u003c\/li\u003e \u003cli\u003eColour Coded, field replaceable sensors\u003c\/li\u003e \u003cli\u003eWaterproof protection\u003c\/li\u003e \u003cli\u003eLogging – from probe to meter\u003c\/li\u003e \u003cli\u003eFast Tracker – Tag Identification system\u003c\/li\u003e \u003cli\u003eSensor Check™ - Auto-recognition of all sensors\u003c\/li\u003e \u003c\/ul\u003e \u003cul\u003e \u003cli\u003eGLP features – Meets good laboratory practices\u003c\/li\u003e \u003cli\u003eConnectivity – PC compatible via USB\u003c\/li\u003e \u003cli\u003eHelp feature – On-screen user guides\u003c\/li\u003e \u003cli\u003eBacklight – Backlit, graphic LCD display\u003c\/li\u003e \u003cli\u003eWaterproof – waterproof casing\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eMeter with or without GPS\u003c\/h3\u003e \u003cp\u003eBuilt in GPS Receiver\u003c\/p\u003e \u003cul\u003e \u003cli\u003e12 channel GPS receiver and antenna\u003c\/li\u003e \u003cli\u003eTracks location using satellites to within 30 feet\u003c\/li\u003e \u003cli\u003eLatitude and longitude recorded with readings\u003c\/li\u003e \u003cli\u003eLocation naming for GPS coordinates\u003c\/li\u003e \u003cli\u003eDistance from current location to stored location\u003c\/li\u003e \u003cli\u003eHI-929829 software supplied integrates data collected with Google™ maps\u003c\/li\u003e \u003c\/ul\u003e \u003cul\u003e \u003cli\u003eMeasurement readings including GPS coordinates\u003c\/li\u003e \u003cli\u003eDate and time\u003c\/li\u003e \u003cli\u003eNamed locations and remarks\u003c\/li\u003e \u003cli\u003eSample number\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e(Google™ maps is a registered trademark of Google™, HANNA Instruments Ltd; has no affiliation with Google™).\u003c\/p\u003e \u003ch3\u003eColour Coded, Field Replaceable Sensors - purchase separately\u003c\/h3\u003e \u003cp\u003eDissolved Oxygen\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-7609829-2 DO\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003epH\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-7609829-0 pH\u003c\/li\u003e \u003cli\u003eHI-7609829-1 pH\/ORP\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eConductivity and Turbidity\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-7609829-4 EC\/Turbidity\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eISE\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-7609829-0 Ammonium ISE\u003c\/li\u003e \u003cli\u003eHI-7609829-11 Chloride ISE\u003c\/li\u003e \u003cli\u003eHI-7609829-12 Nitrate ISE\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eConductivity\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-7609829-3 EC\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eTwo probes to choose from (Basic or Logging) - purchase separately\u003c\/h3\u003e \u003cp\u003eThe HI-7609829 (basic) and HI-7629829 (logging) are multiparameter probes for use with the HI-9829 portable meter. It is an option to choose which probe will be supplied with the HI-9829. By default the HI-9829 and corresponding probe will be supplied with a pH\/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity\/conductivity sensor.\u003c\/p\u003e \u003ch3\u003eHI-7629829 Autonomously Logging Probe - customise and purchase separately\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eSame as basic probe but with logging capability\u003c\/li\u003e \u003cli\u003eLogs data independent of HI-9829 meter\u003c\/li\u003e \u003cli\u003eOperates on 4 “AA” batteries for up to 70 days*\u003c\/li\u003e \u003cli\u003eStores up to 140,000 single parameter readings or 35,000 for all parameters\u003c\/li\u003e \u003cli\u003eLogs data from 1 second to 3 hours\u003c\/li\u003e \u003cli\u003eChoose to be supplied with EC or EC\/Turbidity sensor\u003c\/li\u003e \u003cli\u003eSupplied with USB cable for direct connection to Window’s compatible PC\u003c\/li\u003e \u003c\/ul\u003e \u003cul\u003e \u003cli\u003e*All channels logging at 10 minute intervals with no averaging\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eHI-7609829 Basic Probe - customise and purchase separately\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eDigital probe that is less than 2 inches in diameter\u003c\/li\u003e \u003cli\u003e3 colour-coded sensor inputs\u003c\/li\u003e \u003cli\u003eIP68 rating for continuous immersion in water\u003c\/li\u003e \u003cli\u003eMultistrand, multiconductor cable rated for 150 lbs (intermittent use)\u003c\/li\u003e \u003cli\u003eAvailable with 4, 10, or 20 meter cable\u003c\/li\u003e \u003cli\u003eWeighted shield protects all sensors\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCable lengths\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eThe probes are available with a choice of cable lengths: 4m, 10m and 20m\u003c\/li\u003e \u003cli\u003eDIN connection\u003c\/li\u003e \u003cli\u003eLogging probes can be connected directly to a PC with the HI-76982910 USB adaptor cable and HI-929829 PC application software to download log files directly.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eOn screen features\u003c\/h3\u003e \u003ch3\u003eGPS Option\u003c\/h3\u003e \u003cp\u003eThe meter features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data.\u003c\/p\u003e \u003ch3\u003eQuick Calibration\u003c\/h3\u003e \u003cp\u003eThe quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in few simple steps.\u003c\/p\u003e \u003ch3\u003eGraphing Capability\u003c\/h3\u003e \u003cp\u003eTrend graphing with sample date and time may be viewed on the display or transferred to PC.\u003c\/p\u003e \u003ch3\u003eFeatures:\u003c\/h3\u003e \u003cp\u003e\u003cstrong\u003eWaterproof Protection\u003c\/strong\u003e – The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eBacklit Dot Matrix LCD Display\u003c\/strong\u003e – The HI-9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eIntuitive Keypad\u003c\/strong\u003e – The fitted rubber keypad has dedicated keys for power, backlight, up\/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. The interface is intuitive for any user’s level of experience.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDedicated Help Key\u003c\/strong\u003e – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting\/option being viewed.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eAuto-sensor Recognition\u003c\/strong\u003e - The probe and meter automatically recognise the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eAutomatic temperature compensation\u003c\/strong\u003e – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eAutomatic Barometric Pressure Compensation\u003c\/strong\u003e – The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eQuick Calibration\u003c\/strong\u003e – Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are available including pH up to three points, Conductivity at one point and dissolved oxygen up to two points.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eGLP Data\u003c\/strong\u003e – HI-9829 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers\/standards used for calibration, and slope characteristics.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e – The HI-9829 allows users to store up to 44,000 continuous or log-on-demand samples with logging intervals from one second to three hours.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eGraphing Capability\u003c\/strong\u003e - Trend graphing with sample date and time stamp may be viewed on the display or transferred to a pc.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003ePC Connectivity\u003c\/strong\u003e – Logged data can be transferred to a Windows compatible PC with the included HI-7698291 USB adapter and HI-929829 software.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eLong Battery Life\u003c\/strong\u003e - The display of the meter has a battery icon indicator to show the remaining power. The meter is supplied with four 1.5V “C“ NiMH rechargeable batteries that provide up to 140 hours of battery life*.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eRugged thermoformed carrying case\u003c\/strong\u003e – The HI-9829 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.\u003c\/p\u003e \u003cp\u003e* Without GPS or turbidity measurements\u003c\/p\u003e \u003ch3\u003eFast Tracker™—Tag Identification System\u003c\/h3\u003e \u003cp\u003eHANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButtons with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labelled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.\u003c\/p\u003e \u003ch3\u003eiButton. Tags are Easy to Install\u003c\/h3\u003e \u003cp\u003eInstall the optional TAGs near your sampling points for quick and easy iButton readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-9829 specification with\/without GPS\u003c\/td\u003e\n\u003ctd\u003eNo Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic from -5 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels with GPS\u003c\/td\u003e\n\u003ctd\u003e12 Channel Receiver, 10m range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging memory from meter\u003c\/td\u003e\n\u003ctd\u003e44,000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging interval\u003c\/td\u003e\n\u003ctd\u003e1 second to 3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputer interface\u003c\/td\u003e\n\u003ctd\u003eUSB (with HI-929829)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastTracker™ TAG ID\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaterproof protection\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C, RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e1.5 V Alkaline C cells (4)\/1.2V NiMH rechargeable C Cells (4) USB, 12V power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e221 x 115 x 55mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Probe Immersion\u003c\/td\u003e\n\u003ctd\u003eDepth – 20 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-9829 parameter specifications\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point (relative mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm (absolute EC up to 400 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003eManual: 1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm, Automatic: 1 µS\/cm from 0 to 9999 µS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm, Automatic (mS\/cm): 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 µS\/cm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic single point, with six standard solutions (84 µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 400000 ppm (mg\/L); (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003eManual: 1 ppm (mg\/L); 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L), Automatic: 1 ppm (mg\/L) from 0 to 9999 ppm (mg\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L), Automatic ppt (g\/L): 0.001 ppt (g\/L) from 0.000 to 9.999 ppt (g\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 ppm (mg\/L), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003edependent on resistivity reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% of reading or ±0.01 PSU whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater σ Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 σt, σ0, σ15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater σ Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 σt, σ0, σ15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater σ Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 σt, σ0, σ15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater σ Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium-Nitrogen Range\u003c\/td\u003e\n\u003ctd\u003e0.02 to 200.0 ppm Am (as NH4 +-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium-Nitrogen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium-Nitrogen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 % reading or 2 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium-Nitrogen Calibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point, 10 ppm and 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e0.6 to 200.0 ppm Cl (as Cl- )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 % of reading or 2 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Calibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point, 10 ppm and 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate-Nitrogen Range\u003c\/td\u003e\n\u003ctd\u003e0.62 to 200.0 ppm Ni (as NO3 - -N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate-Nitrogen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm to 1 ppm 0.1 ppm to 200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate-Nitrogen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 % of reading or 2 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate-Nitrogen Calibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point, 10 ppm and 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 99.9 FNU; 100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 FNU or ±2 % of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0%; 0.00 to 50.00 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%; 0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg\/L): ±1.5% of reading or ±0.10 ppm (mg\/L), whichever is greater, 30.00 ppm (mg\/L) to 50.00 ppm (mg\/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic one or two points at 0 and 100% or one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Range\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mm Hg within ±15°C from the temperature during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-9829-10\u003c\/td\u003e\n\u003ctd\u003e25 sachets 10ppm ammonia-nitrogen calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-9829-10\/11\u003c\/td\u003e\n\u003ctd\u003e10 sachets each of 10ppm and 100ppm ammonia-nitrogen calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-9829-11\u003c\/td\u003e\n\u003ctd\u003e25 sachets 100ppm ammonia-nitrogen calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-9829-12\u003c\/td\u003e\n\u003ctd\u003e25 sachets 10ppm chloride calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-9829-12\/13\u003c\/td\u003e\n\u003ctd\u003e10 sachets each of 10ppm and 100ppm chloride calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-9829-13\u003c\/td\u003e\n\u003ctd\u003e25 sachets 100ppm chloride calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-9829-14\u003c\/td\u003e\n\u003ctd\u003e25 sachets 10ppm nitrate-nitrogen calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-9829-14\/15\u003c\/td\u003e\n\u003ctd\u003e10 sachets each of 10ppm and 100pm nitrate-nitrogen calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-9829-15\u003c\/td\u003e\n\u003ctd\u003e25 sachets 100ppm nitrate-nitrogen calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/modules\/teapotknowledgehub\/uploads\/man9829_07_19_web-66337c1e1de93.pdf\" target=\"_blank\"\u003eHI-9829 MULTIPARAMETER PH\/ISE\/EC\/DO\/TURBIDITY WATERPROOF METER (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640110358901,"sku":"HI-9829-02","price":2872.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-9829-02-gps-multiparameter-meter_c66939d4-0496-4205-87fe-bfc81aeda639.jpg?v=1791581595","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-9829-multiparameter-ph-ise-ec-do-turbidity-waterproof-meter-gps-option-available","provider":"Test All Water","version":"1.0","type":"link"}