{"product_id":"hanna-instruments-hi-9810422-halo2-wireless-ph-tester-with-built-in-general-purpose-electrode","title":"Hanna Instruments HI-9810422 HALO2 Wireless pH Tester with built-in general purpose electrode","description":"\u003cp\u003eAccurate and easy-to-use, HALO2 pH Tester is ideal for general use thanks to its durability.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eHI-9810422 HALO2 Wireless pH Tester with built-in general purpose electrode ideal for harsh chemicals\u003c\/strong\u003e\u003c\/h3\u003e \u003cp\u003eThe HI-9810422 can be used as a stand-alone pH tester or can be connected to the Hanna Lab App.\u003c\/p\u003e \u003ch3\u003eFeatures\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eCompact, waterproof casing and automatic pH calibration at up to three points, or four points when used with the Hanna Lab App\u003c\/li\u003e \u003cli\u003eAutomatically temperature compensated readings\u003c\/li\u003e \u003cli\u003eThe electrode features a PEI resin body that is easy to clean and resistant to many aggressive chemicals.\u003c\/li\u003e \u003cli\u003eBuilt-in temperature sensor at the tip of the pH electrode allows for rapid determination of the sample temperature and a high-accuracy temperature reading.\u003c\/li\u003e \u003cli\u003eFast, stable readings thanks to the double junction design which presents a silver-free electrolyte solution interacting with the sample, making the electrode less susceptible to clogging and guaranteeing a fast response and stable reading\u003c\/li\u003e \u003cli\u003eMaintenance free – Gel-filled reference with no fill solutions required. Other than routine calibration and cleaning, this probe is maintenance free.\u003c\/li\u003e \u003cli\u003eStability tagging sends tagged results to the Hanna Lab App only after measurement stability has been achieved.\u003c\/li\u003e \u003cli\u003eThe Hanna app is available on the App Store® and Google Play\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eHALO2 Wireless pH meter with Bluetooth® Smart Technology includes a dual-level LCD and temperature measurement for automatic temperature compensation. HALO2 pH probes can be used virtually anywhere as their versatility and ease of use will revolutionise the way pH is measured.\u003c\/p\u003e \u003cp\u003eAccurate and easy to use, HALO2 wireless pH Testers are ideal for measurements in samples that would be a challenge for standard design pH electrodes.\u003c\/p\u003e \u003cp\u003eThe meters with their specialised electrodes can measure in the lab or out in the field. Then specialised applications: Cosmetic Creams, Soil, Wine, Beer, Meat, Chocolate, Bread and Dough, Cheese, Milk, Sushi, Skin, Leather and Paper.\u003c\/p\u003e \u003ch3\u003eBluetooth Versatility\u003c\/h3\u003e \u003cp\u003eConnect to the Hanna Lab App via Bluetooth® wireless technology (10m range). The Bluetooth icon on the HALO2 LCD indicates the probe is active and transmitting.\u003c\/p\u003e \u003ch3\u003eOne Button Sample Tagging\u003c\/h3\u003e \u003cp\u003ePressing the button on the HALO2 pH probe or the probe icon in the Hanna Lab App will tag sample data for easy reference.\u003c\/p\u003e \u003ch3\u003eEasy calibration\u003c\/h3\u003e \u003cp\u003eHALO2 can be placed right into our calibration buffer sachets for easy calibration. Using a Hanna calibration sachet ensures your buffer is always fresh.\u003c\/p\u003e \u003ch3\u003eEasy to replace battery\u003c\/h3\u003e \u003cp\u003eHALO2’s CR2032 lithium ion battery is easily replaced and lasts for approximately 1,000 hours.\u003c\/p\u003e \u003ch3\u003eYour best choice for wireless HSG282 compliance\u003c\/h3\u003e \u003cp\u003eComplying with HSG282 is a great idea to gain peace of mind if you’re operating hot tub or spa pool facilities for customer access. To achieve compliance, using a suitable HSG282 pH tester is the ideal first step. The HALO2 is the ideal match for effortless recording, making it easy to keep your results safe and sound for five years in line with the HSE’s 2017 guidelines.\u003c\/p\u003e \u003cp\u003eAccurate, practical and highly portable, the HI-9810422 allows you to measure pH in seconds in your hot tub or spa pool. Once you’ve taken your reading, that information is sent directly to the Hanna Lab App, with no extra steps required. Simple.\u003c\/p\u003e \u003cp\u003eBluetooth connectivity and simple operation make it easier than ever to comply with HSG282 legislation, protecting your customers and your business from the risk of sickness. Accurate pH readings are essential to keep your pool chemistry in proper balance with legionella and other serious pathogens multiplying in warm, agitated water.\u003c\/p\u003e \u003cp\u003eWant to know all there is to know about HSG282 regulations? \u003cspan\u003e\u003cspan\u003eRead our complete guide online now\u003c\/span\u003e\u003c\/span\u003e for all the details.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.00 to 12.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emv*\u003c\/td\u003e\n\u003ctd\u003epH\/mV conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 80.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 or 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV*\u003c\/td\u003e\n\u003ctd\u003e0.1 or 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eUp to three points or four points*Automatic buffer recognition with standard buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic (ATC) or Manual (MTC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode\u003c\/td\u003e\n\u003ctd\u003eBuilt-in probe for specific application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody material\u003c\/td\u003e\n\u003ctd\u003ePolyetherimide (PEI) resin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass\u003c\/td\u003e\n\u003ctd\u003eLow temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction\u003c\/td\u003e\n\u003ctd\u003eCeramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell\u003c\/td\u003e\n\u003ctd\u003eDouble, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrolyte\u003c\/td\u003e\n\u003ctd\u003eGel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip\/Shape\u003c\/td\u003e\n\u003ctd\u003eDome\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eCR2032 3V Lithium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eApproximately 1000 hours (500 hours with Bluetooth enabled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51 x 175 x 21mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e50g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering information\u003c\/td\u003e\n\u003ctd\u003eHI-9810422 (HALO2) is supplied with a starter kit consisting of pH 4.01 buffer solution sachet (2), pH 7.01 buffer solution (2), cleaning solution sachet (2), Electrode storage solution (dropper bottle), 3V lithium battery – CR2032, instrument quality certificate and instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003ctd\u003eReadings available with Hanna Lab App\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640109277557,"sku":"HI-9810422","price":164.82,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-9810422-halo2-wireless-ph-tester-for-field-with-built-in-general-purpose-electrode_40f314e8-e0ac-4e85-971c-53091750b59b.jpg?v=1791581551","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-9810422-halo2-wireless-ph-tester-with-built-in-general-purpose-electrode","provider":"Test All Water","version":"1.0","type":"link"}