{"product_id":"hanna-instruments-hi-97757c-ozone-portable-photometer-kit","title":"Hanna Instruments HI-97757C Ozone Portable Photometer Kit","description":"\u003cp\u003eYou can buy the Ozone Portable photometer as a testing kit. The kit includes a rugged carrying case, sample cuvettes (2 pcs.), sample cuvette caps (2 pcs.), plastic stoppers (2 pcs.), A ZERO - CAL Check™ Cuvette A, HI97757B - CAL Check Cuvette B for Ozone, cloth for wiping cuvettes, scissors, 1.5V AA Alkaline battery (3 pcs.), CAL Check standard certificate, battery safety insert, quick reference guide with instructions for manual download, and an instrument quality certificate. Other reagents sold separately. (Kit layout may differ from photograph - left).\u003c\/p\u003e \u003cp\u003eOzone is a widely used disinfectant in the treatment of drinking water, wastewater and swimming pools. Suitable for field or bench measurements.\u003c\/p\u003e\u003ch3\u003eHI-97757C Ozone Portable Photometer Kit\u003c\/h3\u003e \u003cp\u003eThe HI-97757 photometer measures ozone in water samples from 0.00 to 2.00 mg\/L (ppm) using the DPD Colorimetric Method. Ozone is a widely used disinfectant in the treatment of drinking water, wastewater and swimming pools. Suitable for field or bench measurements.\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003eAbout the Ozone Portable Photometer\u003c\/h3\u003e \u003cp\u003eThe HI-97757 is an auto-diagnostic Ozone portable photometer with an advanced optical system that uses a Light Emitting Diode (LED), and a narrow band interference filter that allows for accurate and repeatable readings.\u003c\/p\u003e \u003cp\u003eThe optical system is sealed from outside dust, dirt and water. The meter uses an exclusive positive locking system to ensure that the cuvettes are placed into the holder in the same position every time.\u003c\/p\u003e \u003cp\u003eWith the CAL Check™ functionality, users can validate the performance of the instrument at any time and apply a user calibration (if necessary).\u003c\/p\u003e \u003cp\u003eHanna Instruments CAL Check cuvettes are made with NIST traceable standards. The built-in tutorial mode guides users step-by-step through the measurement process.\u003c\/p\u003e \u003cp\u003eIt includes all steps required for sample preparation, the required reagents and quantities.\u003c\/p\u003e \u003cp\u003eThe ozone photometer features:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSophisticated optical system\u003c\/li\u003e \u003cli\u003eWaterproof IP67, floating case\u003c\/li\u003e \u003cli\u003eBacklit LCD\u003c\/li\u003e \u003cli\u003eThe 128 x 64 Pixel LCD allows for a simplified user interface.\u003c\/li\u003e \u003cli\u003eMeter validation using certified CAL Check cuvettes\u003c\/li\u003e \u003cli\u003eGood Laboratory Practice (GLP) features\u003c\/li\u003e \u003cli\u003eTutorial mode guides the user step-by-step\u003c\/li\u003e \u003cli\u003eIncludes auto-data logging features to easily record water testing results\u003c\/li\u003e \u003cli\u003eBattery status indicator and auto-shut off after 15 minutes\u003c\/li\u003e \u003cli\u003eCompact size - Measures 142.5 mm (5.6”) x 102.5 mm (4”) and only 50.5 mm (2”) thick.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cb\u003eBattery status indicator and auto-shut off \u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eMeasurement on large, backlit LCD display\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eParameter and concentration used is displayed along with the reading.\u003c\/p\u003e \u003cp\u003e\u003cb\u003ePositive locking system\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe Hanna positive-locking system ensures cuvettes are placed into the holder in the same position every time.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eCAL Check™ validation\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eValidate instrument performance at any time using CAL Check cuvettes made with NIST traceable standards.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eReaction timer\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eDisplays time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate intervals for the test being performed.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eSetup menu available at the touch of a button\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eSetup options for meter personalisation include date and time format, language, and enabling the tutorial mode.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eAuto-data logging\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eData autolog helps users keep track of all measurements. Data is automatically saved every time a measurement is made. The data log can hold 200 individual measurements. When the data log is full, the meter will rewrite the oldest data point.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eWaterproof and floating, IP67 meter design\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003eDedicated help\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe dedicated help key provides information relating to current meter operation. It can be used at any stage in the setup or measurement process.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuy as a kit – HI-97757C includes:\u003c\/td\u003e\n\u003ctd\u003eA rugged carrying case, supplied with sample cuvette (2 pcs.), sample cuvette cap (2 pcs.), plastic stopper (2 pcs.), A ZERO - CAL Check™ Cuvette A, HI97757B - CAL Check Cuvette B for Ozone, cloth for wiping cuvettes, scissors, 1.5V AA Alkaline battery (3 pcs.), CAL Check standard certificate, battery safety insert, quick reference guide with instructions for manual download, and instrument quality certificate. Other reagents sold separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eOzone\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as O₃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 mg\/L ±3% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eDPD Colorimetric Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eMeasurement system\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eLight Emitting Diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter\u003c\/td\u003e\n\u003ctd\u003e525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter wavelength accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight detector\u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette type\u003c\/td\u003e\n\u003ctd\u003eRound 24.6 mm diameter (22 mm inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAdditional specifications\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto logging\u003c\/td\u003e\n\u003ctd\u003e50 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128×64 pixel B\/W LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003eAfter 15 minutes of inactivity (30 minutes before a read measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003e1.5 V AA Alkaline (3 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003emore than 800 measurements (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142.5×102.5×50.5 mm (5.6×4.0×2.0\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e380 g (13.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase ingress protection rating\u003c\/td\u003e\n\u003ctd\u003eIP67, floating case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagents sold separately:\u003c\/td\u003e\n\u003ctd\u003eReagents and standards HI-97757-11 CAL Check™ Standards for Ozone; HI-93757-01 Ozone Reagent - 100 tests; HI-93757-03 Ozone Reagent - 300 tests; HI-93703-52 Glycine Powder Reagent - 100 tests; Accessories HI-7101412; HI-977 series blue carrying case with 2 cuvette slots; HI-731318 Cloth for wiping cuvettes (4 pcs.); HI-731331 Glass cuvette (4 pcs.); HI-731336N Cap for glass cuvette (4 pcs.); HI-731360 Glass cuvette with cap (2 pcs.); HI-93703-50 Cuvette cleaning solution (250 mL).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640107082101,"sku":"HI-97757C","price":465.31,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-97757c-ozone-portable-photometer-kit.jpg?v=1791581492","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-97757c-ozone-portable-photometer-kit","provider":"Test All Water","version":"1.0","type":"link"}