{"product_id":"hanna-instruments-hi-97105-marine-master-photometer","title":"Hanna Instruments HI-97105 Marine Master Photometer","description":"\u003cp\u003eThe HI-97105 is designed to accurately determine all Marine pH, Ammonia, Alkalinity, Calcium, Magnesium, Nitrate LR \u0026amp; HR, Nitrite LR, and Phosphate ULR levels in aquariums and marine biology applications.\u003c\/p\u003e\u003cp\u003eThe HI-97105 Marine Master Photometer combines accuracy and ease of use in a simple, portable design.\u003c\/p\u003e \u003cp\u003eThe advanced optical system provides lab-quality accuracy, while its user-friendly design is easy for any aquarium user, making it the perfect photometer for your water quality testing needs.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eNo warm up time needed before taking a measurement.\u003c\/li\u003e \u003cli\u003eTutorial mode for easy step-by-step instructions\u003c\/li\u003e \u003cli\u003eCAL Check\u003csup\u003eTM\u003c\/sup\u003e for performance verification and calibration\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eBetter Features for Better Testing\u003c\/h3\u003e \u003cp\u003eLet your photometer guide you through setup, calibration, and testing with on-screen tutorials and animations, so you always know the next step. Simply access Tutorial Mode at any stage in the setup or measurement process with the dedicated help key.\u003c\/p\u003e \u003cp\u003eThe auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.\u003c\/p\u003e \u003cp\u003eWhen the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.\u003c\/p\u003e \u003ch3\u003eData Logging\u003c\/h3\u003e \u003cp\u003eMissed a measurement? No need to worry because your photometer will automatically log the last 50 measurements. The results can be viewed instantly using the Log Recall Menu.\u003c\/p\u003e \u003ch3\u003eCAL Check\u003csup\u003eTM\u003c\/sup\u003e Validation\u003c\/h3\u003e \u003cp\u003eHanna’s exclusive CAL CheckTM feature provides a stress-free, straightforward way to ensure your photometer is working properly. Simply insert the certified CAL Check\u003csup\u003eTM\u003c\/sup\u003e standards and let your meter guide you through validation. If your photometer is out of specification for any reason, simply calibrate to your standard.\u003c\/p\u003e \u003cp\u003ePlease download the Safety Datasheet(s) which provide more detail on the reagents before use; click on the link in the “safety data sheets” paragraph below.\u003c\/p\u003e \u003ch3\u003eAdvanced Optical System\u003c\/h3\u003e \u003cp\u003eA Light Emitting Diode (LED) provides more light while using less power, and a narrow band interference filter results in more accurate and repeatable readings.\u003c\/p\u003e \u003ch3\u003eBuilt Better\u003c\/h3\u003e \u003cp\u003eDesigned to withstand the knocks, drops, and spills of real life, the new IP67 body ensures top performance in any environment. Internal optics are sealed from outside dust, dirt, and water. In addition, it floats, just in case you drop your meter in water. This photometer uses an exclusive positive locking system to ensure that the cuvettes are placed into the holder in the same position for accurate readings every time.\u003c\/p\u003e \u003ch3\u003ePortable Design\u003c\/h3\u003e \u003cp\u003eMade to fit comfortably in your hand for on-the-go testing or sit on a table for benchtop use, a backlit LCD display provides at-a-glance readings from any angle - day or night. The supplied AA batteries provide life for more than 800 measurements.\u003c\/p\u003e \u003cp\u003eWe believe that buying a meter should be simple. Your HI-97105 photometer has many of the necessary accessories needed for successful measurements.\u003c\/p\u003e \u003cp\u003eEach \u003cstrong\u003eHI-97105\u003c\/strong\u003e is supplied with:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSample cuvette (2 pcs.)\u003c\/li\u003e \u003cli\u003eSample cap (2 pcs.)\u003c\/li\u003e \u003cli\u003ePlastic stopper (2 pcs.)\u003c\/li\u003e \u003cli\u003eAlkaline batteries: 1.5V AA (3 pcs.)\u003c\/li\u003e \u003cli\u003eInstruction manual\u003c\/li\u003e \u003cli\u003eMeter quality certificate\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cb\u003eUpgrade to the Marine Master Photometer Kit (includes the CAL Check\u003csup\u003eTM\u003c\/sup\u003e Standards) for the most economical option for testing.\u003c\/b\u003e\u003c\/h3\u003e \u003cp\u003eEach \u003cstrong\u003eHI-97105C\u003c\/strong\u003e is supplied with:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSample cuvette (2 pcs.)\u003c\/li\u003e \u003cli\u003eSample cuvette cap (2 pcs.)\u003c\/li\u003e \u003cli\u003e1 mL graduated syringe with tip (2 pcs.)\u003c\/li\u003e \u003cli\u003eMini pipette with tip (1 pc.)\u003c\/li\u003e \u003cli\u003e3 mL Pasteur pipette (2 pcs.)\u003c\/li\u003e \u003cli\u003e1.5V AA Alkaline batteries (3 pcs.)\u003c\/li\u003e \u003cli\u003eCloth for wiping cuvettes\u003c\/li\u003e \u003cli\u003eScissors\u003c\/li\u003e \u003cli\u003eInstrument quality certificate\u003c\/li\u003e \u003cli\u003eInstruction manual\u003c\/li\u003e \u003cli\u003eMarine pH reagent, 30 mL dropper (1 pc.)\u003c\/li\u003e \u003cli\u003eMarine Alkalinity reagent, 30 mL (1 pc.)\u003c\/li\u003e \u003cli\u003eMarine Calcium reagent A, 30 mL (1 pc.)\u003c\/li\u003e \u003cli\u003eMarine Calcium reagent B starter kit (reagent for 25 tests)\u003c\/li\u003e \u003cli\u003eMarine Nitrate High Range starter kit (reagent for 25 tests)\u003c\/li\u003e \u003cli\u003eMarine Nitrite Low Range starter kit (reagent for 25 tests)\u003c\/li\u003e \u003cli\u003eMarine Phosphate Ultra Low Range starter kit (reagent for 25 tests)\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003ci\u003e\u003cb\u003e(Please note: not all reagents and the Cal Check standard are included in this kit, so check your testing requirements are covered when ordering. See specification table to choose further reagents. Additional costs apply.)\u003c\/b\u003e\u003c\/i\u003e\u003c\/p\u003e \u003ch3\u003eSafety Data Sheets\u003c\/h3\u003e \u003cp\u003eAccess safety data sheets online here. When using any form of chemical, it is important you download the relevant safety datasheet and make yourself aware of any precautions you should take when handling the chemical. You can access our library of safety datasheets and download a copy by following the link below.\u003c\/p\u003e \u003cp\u003ePlease note that the '-' in HI- products should be removed from all searches to find the correct information.\u003c\/p\u003e \u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/v\/856999\" target=\"_blank\" rel=\"noreferrer noopener\"\u003eclick here\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity, Marine Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 dkH 0 to 357 ppm (as CaCo3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity, Marine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 dkH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity, Marine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 dKH ±5 % of reading at 25 °C ±5 ppm ±5 % of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity, Marine Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric Method - The reaction causes a distinctive range of colours from yellow to greenish blue to develop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia, Marine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm (as NH₃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia, Marine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia, Marine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 ppm ±5% of reading at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia, Marine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Salicylate Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia, Marine LED\u003c\/td\u003e\n\u003ctd\u003e610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium, Marine Range\u003c\/td\u003e\n\u003ctd\u003e200 to 600 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium, Marine Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium, Marine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±6 % of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium, Marine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Zincon Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eMarine Magnesium\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 to 1800 ppm (as Mg2+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Colorimetric EDTA Method using calmagite indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED\u003c\/td\u003e\n\u003ctd\u003e610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 ppm (as No3¯) 0.0 to 75.0 ppm (as No3¯)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm 0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e0 to 200 ppb (as No2¯-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Zincon Method Colorimetric Method The reaction between nitrate and the reagent causes a pink\/violet tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite, Marine Low Range\u003c\/td\u003e\n\u003ctd\u003e0 to 800 ppb (as No2¯-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite, Marine Low Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite, Marine Low - Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10 ppb ±4 % of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite, Marine Low - Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA Diazotization Method 354.1 - The reaction between nitrite and the reagent causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e6.3 to 8.6 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 pH of reading at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric Adaptation of the Phenol Red Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate, ULR Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 0.90 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate, ULR Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate, ULR Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 ppm ±5 % of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate, ULR Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method - The reaction between phosphate and the reagent causes a blue tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003elight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003e200 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e1.5 V AA Alkaline (3 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 800 measurements (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003eAfter 15 minutes of inactivity (30 minutes before a READ measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); 0 to 100% RH, non serviceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e380 g (13.4 oz.); with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eReagents, CAL Check Standards \u0026amp; accessories - buy separately:\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eReagent sets\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-758‑26\u003c\/td\u003e\n\u003ctd\u003eMarine Calcium Reagent - 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-767‑25\u003c\/td\u003e\n\u003ctd\u003eMarine Nitrite LR Reagent - 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-772‑26\u003c\/td\u003e\n\u003ctd\u003eMarine Alkalinity Reagent - 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-774‑25\u003c\/td\u003e\n\u003ctd\u003eMarine Phosphate ULR Reagent - 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-780‑25\u003c\/td\u003e\n\u003ctd\u003eMarine pH Reagent - approximately 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-781‑25\u003c\/td\u003e\n\u003ctd\u003eMarine Nitrate LR Reagent - 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-782‑25\u003c\/td\u003e\n\u003ctd\u003eMarine Nitrate HR Reagent - 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-783-25\u003c\/td\u003e\n\u003ctd\u003eMarine Magnesium Reagents - 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-784-25\u003c\/td\u003e\n\u003ctd\u003eMarine Ammonia Reagent - 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-97105‑11\u003c\/td\u003e\n\u003ctd\u003eCAL Check™ standards for HI-97105 - cuvette kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eOther Accessories\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-70436M\u003c\/td\u003e\n\u003ctd\u003eDeionized water (230 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-7101418\u003c\/td\u003e\n\u003ctd\u003eBlue carrying case for HI-97105C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-731318\u003c\/td\u003e\n\u003ctd\u003eCloth for wiping cuvettes (4 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-731331\u003c\/td\u003e\n\u003ctd\u003eGlass cuvette (4 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-731360\u003c\/td\u003e\n\u003ctd\u003eGlass cuvette with cap (2 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-731336N\u003c\/td\u003e\n\u003ctd\u003eCap for glass cuvette (4 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-731339P\u003c\/td\u003e\n\u003ctd\u003e0.1 mL mini pipette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-731349P\u003c\/td\u003e\n\u003ctd\u003eTip for 0.1 mL mini pipette (10 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-740142P\u003c\/td\u003e\n\u003ctd\u003e1 mL graduated syringe (10 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-740143\u003c\/td\u003e\n\u003ctd\u003e1 mL graduated syringe (6 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-740144P\u003c\/td\u003e\n\u003ctd\u003ePlastic tip for 5 mL syringe (10 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-740157P\u003c\/td\u003e\n\u003ctd\u003ePlastic refilling pipette (20 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-740226\u003c\/td\u003e\n\u003ctd\u003e5 mL graduated syringe (1 pc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-740228\u003c\/td\u003e\n\u003ctd\u003eFilter disc (25 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-740270\u003c\/td\u003e\n\u003ctd\u003e10 mL syringe with Luer Lock (1 pc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-740271\u003c\/td\u003e\n\u003ctd\u003eFilter holder with Luer Lock (1 pc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-740272\u003c\/td\u003e\n\u003ctd\u003e16 gauge blunt needle (6 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-740273\u003c\/td\u003e\n\u003ctd\u003eMarine Nitrate LR measurement kit (1 pc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-93703‑50\u003c\/td\u003e\n\u003ctd\u003eCuvette cleaning solution (230 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/modules\/teapotknowledgehub\/uploads\/man97115_03_261-6ac765305b151.pdf\" target=\"_blank\"\u003eHI-97105 HI-97115 Marine Master Photometer (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640102363509,"sku":"HI-97105","price":305.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-97105-marine-master-photometer_d1a69bf0-201b-4438-a4c4-a7067a93f7bd.jpg?v=1791581350","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-97105-marine-master-photometer","provider":"Test All Water","version":"1.0","type":"link"}