{"product_id":"hanna-instruments-hi-932c2-02-automatic-potentiometric-titration-systems-ph-mv-ise","title":"Hanna Instruments HI-932C2-02 Automatic Potentiometric Titration Systems (pH\/mV\/ISE)","description":"\u003cp\u003eThe HI-932 automatic titrator is designed to perform a wide variety of potentiometric titrations with high accuracy and flexibility, allowing the user to obtain both accurate results and high-speed analysis.\u003c\/p\u003e\u003cp\u003eThe titrator can perform fixed endpoint or equivalence point titrations and direct measurements by measuring the pH\/mV and temperature of the sample.\u003c\/p\u003e \u003cp\u003eReports and materials can be transferred to a PC via a USB interface, saved to a USB storage device or printed directly from the titrator. An external keyboard can also be attached for added convenience.\u003c\/p\u003e \u003cp\u003eThe HI-921 \u0026amp; HI-922 Autosamplers can be connected for sample automation.\u003c\/p\u003e \u003cp\u003e\u003cspan\u003e\u003cb\u003eFor a full demonstration, call today on 01525 850855 to arrange a visit from one of our titration experts.\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e \u003ch3\u003eMain features at a glance:\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eSmall footprint, requires minimal bench space\u003c\/li\u003e \u003cli\u003eCasing made with strong, chemically resistant plastic\u003c\/li\u003e \u003cli\u003eFlexible electrode holder supports up to 3 electrodes, 4 dispensing tubes, 1 temperature sensor and removable stirrer\u003c\/li\u003e \u003cli\u003eElectrode holder positions electrodes in the centre of the beaker, allowing for smaller sample sizes\u003c\/li\u003e \u003cli\u003eIntegrated Peristaltic Pump available for reagent addition\u003c\/li\u003e \u003cli\u003eSupport for 100 titration methods and 30 autosampler sequences\u003c\/li\u003e \u003cli\u003eUser-customisable reports\u003c\/li\u003e \u003cli\u003eIntegrated research grade pH\/mV\/ISE meter\u003c\/li\u003e \u003cli\u003eClearly displayed warning and error messages\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eTitrator capabilities\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003eDynamic titrant dosing\u003c\/h3\u003e \u003cp\u003eThe dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.\u003c\/p\u003e \u003ch3\u003eEquivalence endpoint detection\u003c\/h3\u003e \u003cp\u003eEquivalence endpoint detection is critical in applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.\u003c\/p\u003e \u003ch3\u003eSignal stability timing\u003c\/h3\u003e \u003cp\u003eThe signal stability feature monitors when the mV response of the titration reaction stabilises before providing the next titrant dose. This ensures reliable measurement values throughout the length of a titration.\u003c\/p\u003e \u003ch3\u003eMultiple equivalence point detection\u003c\/h3\u003e \u003cp\u003eHI-932 can detect multiple equivalence points during one titration as specified and required in certain standard methods and applications.\u003c\/p\u003e \u003ch3\u003eMethod sequencing\u003c\/h3\u003e \u003cp\u003eThe HI-932 offers users the option of linking two methods. This allows for two analyses to be run on the same sample including direct measurements, single endpoint titrations, multiple equivalence point titrations, and back titrations.\u003c\/p\u003e \u003ch3\u003eMultiple titration types\u003c\/h3\u003e \u003cp\u003ePaired with the right electrode from our sensor line, our potentiometric titrators can perform acid\/base, redox (ORP), complexometric, precipitation, non-aqueous, argentometric, and ion selective titrations, as well as back titrations and titre determinations.\u003c\/p\u003e \u003ch3\u003eDirect measurement functionality\u003c\/h3\u003e \u003cp\u003eThe HI-932 performs as a high accuracy pH, ORP, and ion selective meter that can link, log, and report direct measurements. Users can easily track and manage data without the hassle of manual record keeping.\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eBurettes and dosing system\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003eExchangeable burette system\u003c\/h3\u003e \u003cp\u003eWith Hanna’s Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.\u003c\/p\u003e \u003ch3\u003eMultiple burette sizes\u003c\/h3\u003e \u003cp\u003eThe HI-932 comes supplied with a 25mL burette but may be equipped with a 5mL, 10mL or 50mL burette. Each burette is constructed with a ground glass syringe and chemically resistant PTFE plunger.\u003c\/p\u003e \u003ch3\u003ePrecision dosing pump\u003c\/h3\u003e \u003cp\u003eOur unmatched 40,000 step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.\u003c\/p\u003e \u003ch3\u003eAutomatic reagent addition\u003c\/h3\u003e \u003cp\u003eA peristaltic pump or a second burette may be programmed to volumetrically dispense reagent prior to titration or direct measurement. This helps achieve consistent and accurate results and prevents operator errors such as incorrect volumes or forgetting reagent addition.\u003c\/p\u003e \u003ch3\u003eRedesigned electrode holder\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eSpring-loaded actuator allows you to quickly raise or lower the stirrer\/electrodes with the push of a button\u003c\/li\u003e \u003cli\u003eSpace-saving geometry allows for sample sizes less than 50mL\u003c\/li\u003e \u003cli\u003eSupport rods mount directly to the titrator – no need for special mounting hardware\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003ePeristaltic pumps\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eAdd reagents to your samples automatically before every titration using integrated peristaltic pumps\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eRedesigned burette well\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eThe burette well is sealed on the bottom to catch drips and spills\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eMethods of analysis\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003eCustomisable methods\u003c\/h3\u003e \u003cp\u003eThese titrators can store up to 100 user-defined or standard titration and direct measurement methods. Each method may be modified and optimised for performance based on application and user requirements.\u003c\/p\u003e \u003ch3\u003eTitration method support\u003c\/h3\u003e \u003cp\u003eOnsite installation, training, and customisation is available from one of our product specialists. Hanna offers continued support for any questions you might have along the way.\u003c\/p\u003e \u003ch3\u003eMarket specific methods packs\u003c\/h3\u003e \u003cp\u003eHanna offers titration method packages for various markets including food, beverage, dairy, wine, and more.\u003c\/p\u003e \u003ch3\u003eData Storage\u003c\/h3\u003e \u003cp\u003eUp to 100 titration and pH\/mV\/ISE reports. Transfer data via USB\u003c\/p\u003e \u003cp\u003e.\u003c\/p\u003e \u003ch3\u003eFlexible GLP management\u003c\/h3\u003e \u003cp\u003eAll necessary GLP (Good Laboratory Practice) information can be recorded with each sample.\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eConnectivity and functionality\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003eMultifunctional\u003c\/h3\u003e \u003cp\u003eThe titrators also function as a titrator, pH meter, mV\/ORP meter, and ISE meter. Valuable laboratory bench space is saved, and multiple analyses can be performed on one sample.\u003c\/p\u003e \u003ch3\u003eMultiple Connections\u003c\/h3\u003e \u003cp\u003eThe HI-932 offers support for two analog boards, allowing up to two electrodes, two burettes, and two stirrers to be connected to one unit simultaneously.\u003c\/p\u003e \u003ch3\u003eAutosampler connectivity\u003c\/h3\u003e \u003cp\u003eThe HI-932 works seamlessly with the HI-922 autosampler featuring 16 or 18 sample tray options, automatic tray identification, and automatic beaker detection. Up to three peristaltic pumps for reagent addition and removal can be connected and real-time analysis and sequencing progress is visible on the HI-932 display as well as indicated by the LED lights of the autosampler.\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eInterface and display\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003eInteractive colour display\u003c\/h3\u003e \u003cp\u003eA large, colour LCD screen clearly shows the chosen titration method along with results, units, titration volume, temperature, and mV or pH values.\u003c\/p\u003e \u003ch3\u003eDetailed titration graphs\u003c\/h3\u003e \u003cp\u003eA real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimisation.\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eFully customisable titration methods\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003eTitration graphs\u003c\/h3\u003e \u003cp\u003eTitration graphs can be viewed on-screen or saved as images and transferred along with titration report.\u003c\/p\u003e \u003ch3\u003eCustomisable reports\u003c\/h3\u003e \u003cp\u003eData to be stored in titration reports is fully customisable.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1; 0.01; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eup to five-point calibration, eight standard buffers and five custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Calibration\u003c\/td\u003e\n\u003ctd\u003esingle point offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eISE\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1•10-6 to 9.999•1010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1; 0.1; 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±0.5% monovalent; ±1% divalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Calibration\u003c\/td\u003e\n\u003ctd\u003eUp to five-point calibration, seven standard solutions and five user-defined standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±0.1°C excluding probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003eup to 100 titration methods (standard and user)up to 30 autosampler sequences\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReports\u003c\/td\u003e\n\u003ctd\u003eup to 100 titration and pH\/mV\/ISE reportsup to 40 autosampler tray reports (eg 720 reports for 18 beaker tray)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAdditional Specifications\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Board(s) capability\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Capability\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette included\u003c\/td\u003e\n\u003ctd\u003e1 (25mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette Size Capability\u003c\/td\u003e\n\u003ctd\u003e5, 10, 25 and 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette Resolution\u003c\/td\u003e\n\u003ctd\u003e1\/40000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full burette volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e14.9cm (5.7”) 320 x 240 pixel) backlit colour LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP Conformity\u003c\/td\u003e\n\u003ctd\u003eInstrumentation data storage and printing capabilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinked Methods\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack Titrations\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-921 \u0026amp; HI-922 autosampler compatible\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering information\u003c\/td\u003e\n\u003ctd\u003eHI-932C2-02 includes titrator with two analog boards* All models also include: overhead propeller stirrer with stand, 25ml glass burette, dosing pump, temperature sensor, USB cable, USB Flash drive and PC Software.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAdditional Extras\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-930101\u003c\/td\u003e\n\u003ctd\u003eDosing pump with peristaltic pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-930100\u003c\/td\u003e\n\u003ctd\u003eDosing pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-930150\u003c\/td\u003e\n\u003ctd\u003e50 mL burette assembly (includes syringe, aspiration, and dispensing tubes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-930125\u003c\/td\u003e\n\u003ctd\u003e25 mL burette assembly (includes syringe, aspiration, and dispensing tubes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-930110\u003c\/td\u003e\n\u003ctd\u003e10 mL burette assembly (includes syringe, aspiration, and dispensing tubes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI-930105\u003c\/td\u003e\n\u003ctd\u003e5 mL burette assembly (includes syringe, aspiration, and dispensing tubes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003e*Each Analog board provides 1 BNC (pH, mV, ISE) input, 1 temperature input, 1 stirrer input.\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640096170357,"sku":"HI-932C2-02","price":10640.48,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-932-c2-02-automatic-potentiometric-titration-systems-ph-mv-ise_b3a82348-91dc-46d0-b843-e73f8baa02b0.jpg?v=1791581183","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-932c2-02-automatic-potentiometric-titration-systems-ph-mv-ise","provider":"Test All Water","version":"1.0","type":"link"}