{"product_id":"hanna-instruments-hi-922-210-autosampler-with-18-beaker-tray-and-one-peristaltic-pump","title":"Hanna Instruments HI-922-210 Autosampler with 18 Beaker Tray and One Peristaltic Pump","description":"\u003cp\u003eThe HI-922 Autosampler is an automated titration sample handling system designed for use with the HI-932 Automatic Titration System, making multiple sample titrations quick and easy.\u003c\/p\u003e \u003cp\u003eWith the Autosampler, up to 18 samples can be run consecutively.\u003c\/p\u003e \u003cp\u003eThis autosampler would need to be used in conjunction with the Hanna HI-932 titrator only.\u003c\/p\u003e\u003ch3\u003eHI-922-210 Autosampler with 18 Beaker Tray and One Peristaltic Pump\u003c\/h3\u003e \u003cp\u003eThe HI-922 Autosampler interfaces directly with the HI-932 to access titration methods. Once a titration method is established, the user can fully customise the automation sequence of their samples for this method. Sample names and size can be customised or auto-filled with preset values.\u003c\/p\u003e \u003cp\u003eOne beaker can be designated for storage purposes before and after titration sequences; up to three beakers per tray can be designated for an electrode rinse sequence, allowing for sufficient removal of solutions that are hard to clean between each sample titration.\u003c\/p\u003e \u003cp\u003eDuring each sample titration, the real-time progress is shown on the HI-932 display. Finished sample results and graphs can be accessed during and after the titrations have finished. Once the Autosampler sequence is complete, two reports are available for review: a sequence report featuring a table outlining each sample name, beaker position, sample size, and result for the tray, and a detailed titration report for each individual sample, including the graph of the titration data.\u003c\/p\u003e \u003ch3\u003e16 or 18 Sample Tray\u003c\/h3\u003e \u003cp\u003eThe HI-922 can automate samples using a 16-sample tray or an 18-sample tray. The 16-sample tray holds 150 mL beakers; the 18-sample tray holds 100 mL beakers. The Autosampler trays are composed of chemically resistant materials and are removable to allow for easy handling. The dishwasher safe trays provide a quick and simple way for users to clean regularly.\u003c\/p\u003e \u003ch3\u003eUse with the HI-932 Automatic Titration System\u003c\/h3\u003e \u003cp\u003eFlexible, accurate detection of the titration endpoint with HI-932 potentiometric titrator. Real-time progress of the sequence and results shown on the HI-932 titrator screen. \u003cstrong\u003eTitrator sold separately.\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI932%20and%20HI922%20main%20image.jpg\" alt=\"Titrator and Autosampler working together\" width=\"367\" height=\"348\"\u003e\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003eBuilt-in Magnetic Stirrer\u003c\/h3\u003e \u003cp\u003eA magnetic stirrer comes built-in with each Autosampler tray. Users simply need to add a small magnetic stir bar to each beaker to ensure homogeneity during titrations. An optional overhead propeller stirrer can also be installed for use instead of the built-in stirrer. The HI-922 allows users to easily adjust the stirring speed of both the built-in and overhead stirrers for optimal use.\u003c\/p\u003e \u003ch3\u003eBuilt-in RFID\u003c\/h3\u003e \u003cp\u003eThe HI-922 sample trays feature a built-in RFID reader that can communicate the tray size and serial number of each tray. Users can have multiple trays, each designated to a specific set of samples. The RFID reader can ensure that the appropriate tray is used each time.\u003c\/p\u003e \u003ch3\u003eAbsolute Encoder\u003c\/h3\u003e \u003cp\u003eThe Autosampler consistently tracks the tray position without the need to “home” or calibrate.\u003c\/p\u003e \u003ch3\u003eBarcode Reader\u003c\/h3\u003e \u003cp\u003eA USB-compatible barcode reader can be used to associate names with each sample for improved organisation of data.\u003c\/p\u003e \u003ch3\u003eOptical IR Beaker Detection\u003c\/h3\u003e \u003cp\u003eAn optical IR beam can detect the presence or absence of beakers within the sample tray. Users can dictate the Autosampler action if a beaker is missing from the tray during a titration sequence. If a beaker is detected as missing, the HI-922 can skip over the sample or stop the titration sequence.\u003c\/p\u003e \u003ch3\u003eVersatile Electrode Holder\u003c\/h3\u003e \u003cp\u003eThe durable electrode holder can accommodate three 12 mm electrodes, a temperature sensor, one aspiration tube, and five multipurpose tubes. The multipurpose tubes can be utilised for actions such as reagent addition or burette dosing.\u003c\/p\u003e \u003ch3\u003eElectrode Rinse Feature\u003c\/h3\u003e \u003cp\u003eUp to 3 beakers per tray can be designated for electrode dip\/spray rinses.\u003c\/p\u003e \u003ch3\u003eSample Levelling Feature\u003c\/h3\u003e \u003cp\u003eAutomatic levelling for fast preparation of volumetric samples.\u003c\/p\u003e \u003ch3\u003eWaste Removal Feature\u003c\/h3\u003e \u003cp\u003eAspirate completed samples into a waste container.\u003c\/p\u003e \u003ch3\u003eControl Panel\u003c\/h3\u003e \u003cp\u003eThe included control panel features multiple buttons to allow for manual operation of the Autosampler tray, electrode holder, and any auxiliary pumps. A two-line backlit display on the handheld panel clearly displays status information. Manual control with the control panel is desirable for calibration, sample preparation, and method optimisation.\u003c\/p\u003e \u003ch3\u003ePeristaltic and Membrane Pumps\u003c\/h3\u003e \u003cp\u003e• Up to three peristaltic pumps can be added at any time • User replaceable pump systems • Peristaltic pumps:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eUses high performance plastic that is engineered to be chemically resistant and have long service life.\u003c\/li\u003e \u003cli\u003eReagent addition, sample levelling, waste removal\u003c\/li\u003e \u003cli\u003eGreater than 200 mL\/min flow\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e• Membrane pumps:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSimple plug connection for tubing\u003c\/li\u003e \u003cli\u003eGreater than 400 mL\/min flow\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eUsers can add up to three peristaltic pumps or one membrane pump at any time with the user-replaceable pump systems on the HI-922. The peristaltic pumps use high performance plastic that is engineered to be chemically resistant with a long service life.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/Peristaltic%20Pumps%20-%20Autosampler.jpg\" alt=\"Peristaltic Pumps - Autosampler\" width=\"365\" height=\"360\"\u003e\u003c\/p\u003e \u003cp\u003eThese pumps have a flow greater than 200 mL\/min and can be utilised for reagent addition, sample levelling, and waste removal. The membrane pump is a simple plug connection for tubing that has a flow greater than 400 mL\/min.\u003c\/p\u003e \u003ch3\u003eStatus indicator lights\u003c\/h3\u003e \u003cp\u003eHighly visible status lights are located on both sides of the Autosampler. These lights correspond to the status indicator on the HI-932 display and can easily be seen from far away. The lights double as a safety feature, as pressing them at any time will automatically stop the current titration sequence.\u003c\/p\u003e \u003cp\u003e\u003cbr\u003e \u003cspan\u003e• Steady green: Idle, ready to start\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Flashing green: Titration sequence running\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/Green%20light%20HI922.jpg\" alt=\"Green light - Autosampler\" width=\"360\" height=\"240\"\u003e\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan\u003e• Flashing yellow: Titration sequence paused\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/yellow%20light%20HI922.jpg\" alt=\"Yellow light - Autosampler\" width=\"360\" height=\"239\"\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan\u003e• Steady Red: Error or emergency stopped, or initialising during power on\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Flashing Red: Error during sequence running or manual operation\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/red%20light%20HI922.jpg\" alt=\"Red light - Autosampler\" width=\"360\" height=\"241\"\u003e\u003c\/p\u003e \u003ch3\u003eRFID recognition\u003c\/h3\u003e \u003cp\u003eSample trays are automatically detected and identified when placed on the Autosampler.\u003c\/p\u003e \u003ch3\u003eDigital balance compatibility\u003c\/h3\u003e \u003cp\u003eSample weights are communicated when connected to a digital balance.\u003c\/p\u003e \u003ch3\u003eSpeedy sample entry\u003c\/h3\u003e \u003cp\u003eSample names can be automatically incremented for speedy sample identification.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Holder Slots\u003c\/td\u003e\n\u003ctd\u003e3 x 12mm electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003e1 temperature sensor\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003e1 aspiration tube\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003e5 multi-purpose slots (titrant\/reagent tubes)\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003e1 overhead stirrer\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003eHI-7662-A (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrers\u003c\/td\u003e\n\u003ctd\u003eBuilt-in magnetic stirrer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eOptional overhead propeller stirrer\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeristaltic pumps\u003c\/td\u003e\n\u003ctd\u003eUp to 3 can be installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eInstalls in slots #1, 2, 3\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMembrane Pump for cleaning\u003c\/td\u003e\n\u003ctd\u003eInstalls in slot #4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrays\u003c\/td\u003e\n\u003ctd\u003e16 beakers x 150mL (HI-920-11660)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003e18 beakers x 100mL (Hi-920-11853)\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eBuilt-in RFID, transmits the tray type and serial number to autosampler\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeakers\u003c\/td\u003e\n\u003ctd\u003eASTM Short-form glass beakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-920-060 (150mL), fits HI-920-11660 tray – 20 plastic beakers\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-920-053 (100mL), fits HI-920-11853 tray – 20 plastic beakers\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eButtons for manual operation of tray and titration head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eManual operation of peristaltic or membrane pumps\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003e2-line backlit display with status information\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarcode reader\u003c\/td\u003e\n\u003ctd\u003eCompatible with USB barcode readers. Used to add sample names\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReport storage\u003c\/td\u003e\n\u003ctd\u003eUp to 40 trays of samples – 720 reports for 18-beaker tray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChoose your AutosamplerConfiguration: HI-922-XYZ\u003c\/td\u003e\n\u003ctd\u003eX = 1 - 16 sample tray 2 - 18 sample trayY = 0 - No peristaltic pump 1 - One peristaltic pump 2 - Two peristaltic pumps 3 - Three peristaltic pumpsZ = 0 - No membrane pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640094105973,"sku":"HI-922-210","price":11729.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-922-210-autosampler-with-18-beaker-tray-and-one-peristaltic-pump_af78e8d6-82c9-4ae9-8089-bbd24fd6e812.jpg?v=1791581155","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-922-210-autosampler-with-18-beaker-tray-and-one-peristaltic-pump","provider":"Test All Water","version":"1.0","type":"link"}