{"product_id":"hanna-instruments-hi-8936cln-conductivity-transmitter","title":"Hanna Instruments HI-8936CLN Conductivity Transmitter","description":"\u003cp\u003eHI-8936 is a conductivity transmitter that utilises a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. This allows the transmitter to operate at peak performance at all times.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eAutomatic temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations\u003c\/li\u003e \u003cli\u003eOptional backlit, LCD display for easy viewing\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eConductivity Transmitter Using 4-Ring Technology, range: 0 to 1999 µS\/cm; with LCD display.\u003c\/h3\u003e \u003ch3\u003eEasy Installation\u003c\/h3\u003e \u003cp\u003eThe HI-8936 transmitter may be wall-mounted at any convenient location close to the measurement site. The HI-8936 series should be used in conjunction with the HI-7635 in-line probe or HI-7638 platinum probe.\u003c\/p\u003e \u003ch3\u003eOptional LCD\u003c\/h3\u003e \u003cp\u003eHI-8936”L” versions allow easy verification and monitoring of measured values and is easier to calibrate and maintain.\u003c\/p\u003e \u003ch3\u003eAutomatic Temperature Compensation\u003c\/h3\u003e \u003cp\u003eTemperature effects are compensated for by utilising both the built-in temperature sensor on the probe and the transmitter’s ATC circuitry with a of 2%\/°C.\u003c\/p\u003e \u003ch3\u003eDirect Probe Connection\u003c\/h3\u003e \u003cp\u003eDirect connection of the probe to the transmitter assures a positive electrical connection with no signal loss over long distances.\u003c\/p\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eEC Range\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eHI-8936AN \u0026amp; ALN: 0.0 to 199.9 mS\/cm\u003cbr\u003e HI-8936BN \u0026amp; BLN: 0.00 to 19.99 mS\/cm HI-8931CN \u0026amp; CLN: 0 to 1999 µS\/cm HI-8931DN \u0026amp; DLN: 0.0 to 199.9 µS\/cm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEC Resolution\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eHI-8936AN \u0026amp; ALN: 0.1 mS\/cm\u003cbr\u003e HI-8931BN \u0026amp; BLN: 0.01 mS\/cm\u003cbr\u003e HI-8931CN \u0026amp; CLN: 1 µS\/cm\u003cbr\u003e HI-8931DN \u0026amp; DLN: 0.1 µS\/cm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEC Accuracy\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e±2% F.S. (excluding probe error)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEC Calibration\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003emanual, two point, through offset and slope trimmers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003efixed or automatic from 0 to 50°C (32 to 122°F) with β=2%\/°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEC\/TDS Probe\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eHI-7635 for in-line applications (not included)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRecorder Output\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e4-20 mA, not isolated, max 500 Ohm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLCD Display\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eAN, BN, CN \u0026amp; DN = No\u003cbr\u003e ALN, BLN, CLN, \u0026amp; DLN = Yes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Supply\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003ewithout LCD: 12-30 VDC; with LCD: 17-36 VDC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnvironment\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIP Rating\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eIP65\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDimensions\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e165 x 110 x 71 mm (6.5 x 4.3 x 2.8’’)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003e1KG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOrdering Information\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003ctd\u003eThe HI-8936 series is supplied with instructions\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003eHI-8936AN \u0026amp; ALN: 0.0 to 199.9 mS\/cm HI-8936BN \u0026amp; BLN: 0.00 to 19.99 mS\/cm HI-8931CN \u0026amp; CLN: 0 to 1999 µS\/cm HI-8931DN \u0026amp; DLN: 0.0 to 199.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003eHI-8936AN \u0026amp; ALN: 0.1 mS\/cm HI-8931BN \u0026amp; BLN: 0.01 mS\/cm HI-8931CN \u0026amp; CLN: 1 µS\/cm HI-8931DN \u0026amp; DLN: 0.1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S. (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, two point, through offset and slope trimmers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003efixed or automatic from 0 to 50°C (32 to 122°F) with β=2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Probe\u003c\/td\u003e\n\u003ctd\u003eHI-7635 for in-line applications (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, not isolated, max 500 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD Display\u003c\/td\u003e\n\u003ctd\u003eAN, BN, CN \u0026amp; DN = No ALN, BLN, CLN, \u0026amp; DLN = Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003ewithout LCD: 12-30 VDC; with LCD: 17-36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e165 x 110 x 71 mm (6.5 x 4.3 x 2.8’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003eThe HI-8936 series is supplied with instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640093057397,"sku":"HI-8936CLN","price":596.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/conductivity-transmitter-using-4-ring-technology-range-0-to-19.jpg?v=1791581112","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-8936cln-conductivity-transmitter","provider":"Test All Water","version":"1.0","type":"link"}