{"product_id":"hanna-instruments-hi-6522-ph-orp-ise-ec-multiparameter-modular-benchtop-meter","title":"Hanna Instruments HI-6522 pH\/ORP\/ISE + EC Multiparameter Modular Benchtop Meter","description":"\u003cp\u003e\u003cspan\u003eHI-6522 pH\/ORP\/ISE + EC Multiparameter Modular Benchtop Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis kit includes the necessary modules and probes to measure pH, temperature and conductivity, providing everything needed to start measuring straight out of the box. This advanced multimeter features WiFi and ethernet connectivity. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-features product__features\"\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e EC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eISE\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eORP\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003epH\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cp\u003eThe HI-6522 Kit for the HI-6000 includes the HI-6000 modular laboratory meter system, a HI-6000-2 pH\/ISE module and a HI-6000-3 EC module. Also included is the \u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/57-ph-electrode-glass-body-general-purpose-for-laboratory\"\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e\u003c\/a\u003e, \u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/2980-hi-7662-tw-temperature-probe\"\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e\u003c\/a\u003e and\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/2974-hi-7631233-platinum-four-ring-ec-and-resistivity-probe\"\u003eHI-7631233 EC and resistivity probe\u003c\/a\u003e\u003c\/span\u003e. This kit includes everything needed for the accurate measurement of EC and pH, including a calibration solution starter set for EC and pH.\u003c\/p\u003e\n\u003cp\u003eHI-6000 is a fully flexible measurement platform that can be customised according to the user’s application needs. Designed and developed using the latest generation technologies, it gives complete control over measurements.\u003c\/p\u003e\n\u003cp\u003eThis kit is compatible with a wide range of Hanna Instruments electrodes for ISE measurement. For advice on the best electrodes for your needs speak to our in-house specialists directly.\u003c\/p\u003e\n\u003cp\u003eSix different pre-built kits are available for the HI-6000 multimeter, including the modules and electrodes required for laboratory-grade measurement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2988-hi-6222-02-ph-orp-ise-multiparameter-modular-benchtop-system\"\u003eHI-6222 pH\/ORP\/ISE Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2989-hi-6522-02-ph-orp-ise-ec-multiparameter-modular-benchtop-system\"\u003eHI-6522 pH\/ORP\/ISE + EC Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2990-hi-6542-02-ph-orp-ise-optical-do-multiparameter-modular-benchtop-system\"\u003eHI-6542 pH\/ORP\/ISE + Optical DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2991-hi-6542p-02-ph-orp-ise-polarographic-do-multiparameter-modular-benchtop-system\"\u003eHI-6542\/P pH\/ORP\/ISE + Polarographic DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2992-hi-6553-02-ph-orp-ise-ec-optical-do-multiparameter-modular-benchtop-system\"\u003eHI-6553 pH\/ORP\/ISE + EC + Optical DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2993-hi-6553p-02-ph-orp-ise-ec-polarographic-do-multiparameter-modular-benchtop-system\"\u003eHI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003eSpecification:\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHI-6522-02 pH\/ORP\/ISE + EC Kit\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003emV\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1 x 10\u003csup\u003e-6\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eto 9.99 x 10\u003csup\u003e10\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econcentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1; 0.1; 0.01; 0.001 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV offset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003epH Calibration\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard buffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOffset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable; Isopotential point: -2.000 to 20.000pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConductivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm; 100.0 to 999.9 μS\/cm;\u003cbr\u003e1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e0.0500 to 200.00 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Type\u003c\/td\u003e\n\u003ctd\u003eautomatic; manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eSingle\u003cbr\u003eMultiple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration solutions\u003c\/td\u003e\n\u003ctd\u003e84.00 μS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear, natural, standard, disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003eRange: 5.0 to 30.0˚C (41.0 to 86.0˚C\u003cbr\u003eResolution 0.1˚C \/ 0.1˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00%\/˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eResistivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 Ω・cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTotal Dissolved Solids (TDS)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSalinity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU - Practical Scale\u003cbr\u003e0.00 to 80.00 ppt - Natural Sea Water\u003cbr\u003e0.0 to 400.0 % - Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 for Practical Scale \/ Natural Sea Water\u003cbr\u003e0.1 % for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 point for Percent Scale, using 100% salinity calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C; -4.0 to 248.0˚F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57492952875381,"sku":"HI-6522-02","price":1282.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-6522-02-ph-orp-ise-ec-multiparameter-modular-benchtop-system.jpg?v=1786545063","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-6522-ph-orp-ise-ec-multiparameter-modular-benchtop-meter","provider":"Test All Water","version":"1.0","type":"link"}