{"product_id":"hanna-instruments-hi-6421-advanced-dissolved-oxygen-optical-benchtop-meter","title":"Hanna Instruments HI-6421 Advanced Dissolved Oxygen Optical Benchtop Meter","description":"\u003cp\u003eThe HI-6421 Advanced Benchtop Meter for Dissolved Oxygen is a laboratory-grade solution for the accurate measurement of DO, BOD, OUR and SOUR in both fresh and saltwater samples. This modern laboratory DO meter includes five different viewing modes, ethernet and WiFi connectivity and a comprehensive on-screen tutorial for ease-of-use.\u003c\/p\u003e\u003ch3\u003eHI-6421 Advanced Dissolved Oxygen Optical Benchtop Meter\u003c\/h3\u003e \u003cp\u003eThe HI-6421 DO optical meter from Hanna Instruments provides an accurate and reliable laboratory-grade solution for measuring dissolved oxygen, oxygen uptake rate, specific oxygen uptake rate and biochemical oxygen demand in both freshwater and saltwater samples. This benchtop meter is equipped with an optical dissolved meter, while the HI-6421\/P is supplied with a polarographic DO probe.\u003c\/p\u003e \u003cp\u003eThe HI-7641133 Opdo optical dissolved oxygen probe is included with the HI-6421. This probe is fitted with easy-to-use Smart Caps (HI-764113-1), which lock into place and contain pre-loaded calibration coefficients that transmit automatically to the probe. Each Smart Cap features an immobilised O2-sensitive luminophore within a rugged, insoluble black oxygen-permeable protective layer.\u003c\/p\u003e \u003cp\u003eAs the optical components of the sensor age, the measuring path is compensated with the reference signal. This ensures the HI-6421 DO benchtop lab meter provides accurate dissolved oxygen measurements over long periods without frequent calibration.\u003c\/p\u003e \u003ch2\u003eHI-6421 Laboratory DO Optical Meter Features\u003c\/h2\u003e \u003ch3\u003eSpace-saving, modern design\u003c\/h3\u003e \u003cp\u003eThe HI-6000 series is designed to fit into modern laboratories, with a smaller footprint and simple design featuring a large, capacitive touchscreen that is functional even with gloves on. WiFi and ethernet connectivity and a flexible electrode arm allow the HI-6421 to be placed anywhere in the lab to save on space without reducing functionality.\u003c\/p\u003e \u003ch3\u003eSupplied with Hanna Opdo optical probe\u003c\/h3\u003e \u003cp\u003eHanna’s HI-7641133 Opdo optical dissolved oxygen probe is supplied with the HI-6421 DO meter, based on the principle of fluorescence quenching. An immobilised Pt-based luminophore is excited by a blue LED light and emits a red light, which interacts with oxygen. The intensity and lifetime of the luminescence is measured by a photodetector in the opdo probe, which is then used to calculate the concentration of dissolved oxygen.\u003c\/p\u003e \u003ch3\u003eFlexible electrode holder\u003c\/h3\u003e \u003cp\u003eA Hanna electrode arm is included as standard with the HI-6421 benchtop DO meter, providing a secure hold for the opdo probe when measuring samples of salt or freshwater. This electrode holder can be mounted to either side of the body of the meter for greater flexibility.\u003c\/p\u003e \u003ch3\u003eAccurate, reliable and repeatable measurement\u003c\/h3\u003e \u003cp\u003eThe HI-6421 provides accurate, reliable and repeatable measurements in a wide range of fresh and saltwater samples. This laboratory-grade benchtop meter ensures precision in testing for the measurement of DO (%Sat, mg\/L, ppm), BOD (mg\/L, ppm), OUR (mg\/L) and SOUR (ppm, mg\/L).\u003c\/p\u003e \u003ch3\u003eFlexible configuration and design\u003c\/h3\u003e \u003cp\u003eDigital connectivity with the option for both WiFi and ethernet means the HI-6000 series benchtop meters can be placed anywhere, with no restrictions for physical proximity to a printer or desktop PC. A configurable, flexible electrode arm is mountable on either side of the instruments allows the HI-6421 to fit into the available space in the lab.\u003c\/p\u003e \u003ch3\u003eSimple-to-use interface\u003c\/h3\u003e \u003cp\u003eOperation immediately out of the box is effortless, with a user-friendly interface and quick access to settings to set up and customise the HI-6421 to your requirements. The comprehensive menu system on this DO meter includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eNetwork\u003c\/li\u003e \u003cli\u003eConnect and Print\u003c\/li\u003e \u003cli\u003eSystem\u003c\/li\u003e \u003cli\u003eCustom Users\u003c\/li\u003e \u003cli\u003eUser Account Management\u003c\/li\u003e \u003cli\u003eInfo Screen\u003c\/li\u003e \u003cli\u003eLog Recall\u003c\/li\u003e \u003cli\u003eLog History and Sharing\u003c\/li\u003e \u003cli\u003eLog Detail\u003c\/li\u003e \u003cli\u003eOn-Board Help\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eFive measurement view options\u003c\/h3\u003e \u003cp\u003eTailor your measurement view to suit your needs with five individual options to choose from, each designed to meet a different requirement when measuring samples for dissolved oxygen:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eBasic View:\u003c\/strong\u003e A clean view featuring basic information about measurement\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSimple GLP View:\u003c\/strong\u003e Additional displays of GLP data, including  Including latest calibration date and time, Offset value, average slope and electrode condition. \u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFull GLP View:\u003c\/strong\u003e A complete GLP display featuring the electrode symbol and used buffers tray in addition to the above visuals.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGraph View:\u003c\/strong\u003e A plotted graph from the active log of the current measurement\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eTabulated View:\u003c\/strong\u003e An organised table of data with date, time and notes in chronological order of testing.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eComprehensive data storage\u003c\/h3\u003e \u003cp\u003eUp to one million individual data points with time and date stamps can be stored within the HI-6000 series before transfer is required. Once exported via WiFi, ethernet, direct connection or USB stick this data is available in a universal .csv file format, with no additional software required for access.\u003c\/p\u003e \u003ch3\u003eDual alarm system\u003c\/h3\u003e \u003cp\u003eBoth audible and visual configurable alarms are available in the settings for the HI-6421 DO optical meter for labs, with the ability to configure the correct range for your samples. Measurements outside these ranges will trigger visual and\/or audible alarms.\u003c\/p\u003e \u003ch3\u003eRemote transfer with ethernet and WiFi\u003c\/h3\u003e \u003cp\u003eThe HI-6421 dissolved oxygen benchtop meter features WiFi and ethernet connectivity, allowing the transfer of data to any computer or email address via FTP or email log exports. These .csv files are accessible without the need to run the data through any software, providing excellent accessibility to remote labs, clients and other sites.\u003c\/p\u003e \u003ch3\u003eUSB C and USB A support\u003c\/h3\u003e \u003cp\u003eExport data via USB stick with both USB A and C connection available on the HI-6421, allowing for the fast and easy transfer of data points as a universal .csv file. Peripherals such as keyboards can also be connected, as well as PCs, laptops and printers as required. \u003c\/p\u003e \u003ch3\u003eVideo and text tutorial system\u003c\/h3\u003e \u003cp\u003eHI-6000 advanced meters include an on-screen, complete tutorial available as text and video through the HELP functionality. These instructions cover all of the main functionalities required to operate these lab-grade meters, allowing you to start measuring straight out of the box.\u003c\/p\u003e \u003ch3\u003eCustomise and create users\u003c\/h3\u003e \u003cp\u003eBoth administrator and standard users can be created on the HI-6421, providing full control over the configurations available to each user. Administrators are able to both create and manage other users from the Account Management Screen to limit or add permissions for day-to-day usage.\u003c\/p\u003e \u003ch2\u003eFAQs\u003c\/h2\u003e \u003ch3\u003eWhat instruments are in the HI-6000 range?\u003c\/h3\u003e \u003cp\u003eThe HI-6000 range includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-6221 pH and ORP meter\u003c\/li\u003e \u003cli\u003eHI-6321 Conductivity meter\u003c\/li\u003e \u003cli\u003eHI-6421 Dissolved Oxygen meter (also available with polarographic probe)\u003c\/li\u003e \u003cli\u003eHI-6000 Modular Multiparameter meter\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eIs the HI-6421 DO meter suitable for laboratory usage?\u003c\/h3\u003e \u003cp\u003eEvery meter in the HI-6000 range, including the HI-6421 for DO, is specifically developed for use in laboratory-grade environments. This high-grade meter is suitable both for industries and businesses and for the laboratories that provide outsourced testing to their clients across a range of specialisations and niches.\u003c\/p\u003e \u003ch3\u003eWhat are the key features of the HI-6421?\u003c\/h3\u003e \u003cp\u003eSome of the key features of the Hanna HI-6421 include:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMeasures DO, SOUR, OUR and BOD\u003c\/li\u003e \u003cli\u003eConnect via WiFi and ethernet\u003c\/li\u003e \u003cli\u003eEasy-to-use interface\u003c\/li\u003e \u003cli\u003eSpace-saving design\u003c\/li\u003e \u003cli\u003eExceptional repeatability and accuracy\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCan I get training on the HI-6421 meter?\u003c\/h3\u003e \u003ch3\u003eWhat industries is the HI-6421 suitable for?\u003c\/h3\u003e \u003cp\u003eThe HI-6421 optical benchtop meter for DO is a versatile instrument that is suitable for the measurement of both fresh and saltwater across a range of applications. This laboratory meter is beneficial for different industries that require the measurement of water and wastewater.\u003c\/p\u003e \u003ch3\u003eHow do I book a demonstration with Hanna Instruments?\u003c\/h3\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-6421 - DO (HI-7641133 Optical probe)\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 50.00 mg\/L (ppm) concentration; 0.0 to 500.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003efrom 0.00 to 20.00 mg\/L (ppm) 1.5 % of reading or ±0.01 mg\/L (ppm), whichever is greater from 20.00 to 50.00 mg\/L (ppm) ±5 % of reading from 0.0 to 200.0 % saturation ±1.5 % of reading or ±0.1 %, whichever is greater from 200.0 to 500.0 % saturation ±5 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-6421P – DO (HI-764833 Polarographic probe)\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5 % of reading ±1, least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eBarometric Pressure\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mmHg; 600 to 1133 mBar; 60 to 133 kPa; 17 to 33 inHg; 8.7 to 16.4 psi; 0.592 to 1.118 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mmHg; 1 mBar; 1 kPa; 1 inHg; 0.1 psi; 0.001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mmHg within ±15 % from the calibration point ±3 mmHg ±1 least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDO Calibration\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoints\u003c\/td\u003e\n\u003ctd\u003eDO optical One or two points automatic calibration at 100% (8.26 mg\/L) and 0% (0 mg\/L). Single point manual using a value entered by the user in % saturation or mg\/L. DO polarographic Automatic-two points \/ User standard-single point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003e0 and 100% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReminder\u003c\/td\u003e\n\u003ctd\u003eDisabled Daily: 0 min. to 23 hours and 59 min. Periodic: 1 min. to 500 days, 23 hours and 59 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation (Optical DO only)\u003c\/td\u003e\n\u003ctd\u003eAutomatic from 0 to 70 PSU (manually set) 0.0 to 70.0 % \/ 0.0 to 45.0 g\/L \/ 0.0 to 42.0 psu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eReading\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eDirect Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate Medium Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential\u003c\/td\u003e\n\u003ctd\u003e7.000 or 4.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling rate\u003c\/td\u003e\n\u003ctd\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDO Views\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (DO, Temperature) Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information Last calibration date, offset, average slope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTable\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph (Plot)\u003c\/td\u003e\n\u003ctd\u003eMeasurement versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per file Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport option\u003c\/td\u003e\n\u003ctd\u003e.csv file format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsers\u003c\/td\u003e\n\u003ctd\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.2 kg (26.5 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003eHI-6421 is supplied with HI-7641133 optical dissolved oxygen probe (OPDO®); HI-764060 electrode holder; capillary pipette; 24 VDC power adapter; USB-C to USB-A cable; probe quality certificate; quick reference guide with instrument quality certificate. HI-6421P is supplied with HI-764833 polarographic probe; HI-764060 electrode holder; capillary pipette; 24 VDC power adapter; USB-C to USB-A cable; probe quality certificate; quick reference guide with instrument quality certificate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/modules\/teapotknowledgehub\/uploads\/man6421_05_23-64ff2b28d2e51.pdf\" target=\"_blank\"\u003eHI-6421 Advanced Dissolved Oxygen Meter Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640069464437,"sku":"HI-6421-02","price":1763.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-6421-advanced-dissolved-oxygen-meter-with-hi-7641133-optical-do-probe_035767f9-e042-4066-93d0-8531a5333b12.jpg?v=1791580394","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-6421-advanced-dissolved-oxygen-optical-benchtop-meter","provider":"Test All Water","version":"1.0","type":"link"}