{"product_id":"hanna-instruments-hi-2630-conductivity-benchtop-meter","title":"Hanna Instruments HI-2630 Conductivity Benchtop meter","description":"\u003cp\u003eHI-2630 benchtop meter enables fast, accurate measurements of conductivity, TDS, and temperature utilising Hanna digital probes – HI-763100 Digital Conductivity electrode with temperature sensor. Ideal for laboratories, classrooms and general industry.\u003c\/p\u003e \u003cp\u003eThe HI-2630 architecture brings together Hanna’s visionary design capabilities, integrated production, and world class research and development.\u003c\/p\u003e\u003ch3\u003e\u003cspan\u003eHI-2630 Conductivity Benchtop meter\u003c\/span\u003e\u003c\/h3\u003e \u003cp\u003eHI-2630 benchtop meter enables fast, accurate measurements utilising the Hanna Instruments digital electrode for conductivity (HI-763100) which includes an integral temperature sensor. Each digital electrode has a unique serial number and the parameter that it measures is automatically identified by the meter.\u003c\/p\u003e \u003cp\u003eThe intuitive design simplifies configuration, calibration, measurement, data logging and transfer of data to a USB thumb drive or computer.\u003c\/p\u003e \u003cp\u003eThe meter has a large display with capacitive keys which features a 5.5” (14 cm) LCD. The large display provides a 130 ° wide viewing angle.\u003c\/p\u003e \u003ch3\u003e\u003cspan\u003eMain feature points\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eAutomatic parameter recognition\u003c\/li\u003e \u003cli\u003eEC choice of measurement unit: Conductivity: µS\/cm, mS\/cm\u003c\/li\u003e \u003cli\u003eTDS - ppm (mg\/L), g\/L\u003c\/li\u003e \u003cli\u003eAdjustable resolution for EC measurements\u003c\/li\u003e \u003cli\u003eDedicated GLP key\u003c\/li\u003e \u003cli\u003eSimplified data transfer to a PC\u003c\/li\u003e \u003cli\u003eInternal clock and date\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e \u003cp\u003e\u003cb\u003eDigital probe input\u003c\/b\u003e - simply connect each probe via the 3.5 mm jack, Digital Smart Electrodes are automatically recognised.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eClear, full text readout\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e- The HI-2630 presents clear, detailed text prompts at the bottom section of the screen.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eGLP\u003c\/b\u003e - The sensor retains data from the most recent calibration, including date, time, and buffers utilised.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eCapacitive touch keypad\u003c\/b\u003e - HI-2630 features sensitive capacitive touch buttons for accurate keystrokes for navigating menus and screens. Since they are part of the screen, the buttons can never get clogged with sample residue.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eEasy to read LCD\u003c\/b\u003e - HI-2630 features a 5.5” (14 cm) LCD display that you can clearly view from over 5 m (16.4’). The large display, with its wide 130° viewing angle, provides one of the easiest to read LCDs in the industry.\u003c\/p\u003e \u003ch3\u003eWhat's included:\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-763100 digital conductivity electrode\u003c\/li\u003e \u003cli\u003eHI-764026 Electrode holder with the following accessories: base plate with integrated pivot pin; cable holder clip, attached\u003c\/li\u003e \u003cli\u003e12880 µS\/cm calibration solution, x 2 sachets\u003c\/li\u003e \u003cli\u003e1413 µS\/cm calibration solution, x 4 sachets\u003c\/li\u003e \u003cli\u003e5000 µS\/cm calibration solution, x 2 sachets\u003c\/li\u003e \u003cli\u003eElectrode rinse solution x 2 sachets\u003c\/li\u003e \u003cli\u003eHI-920018 - 1.5m USB-C to USB-C cable\u003c\/li\u003e \u003cli\u003eUSB-C power adapter\u003c\/li\u003e \u003cli\u003eInstrument quality certificate\u003c\/li\u003e \u003cli\u003eProbe \/ electrode quality certificate\u003c\/li\u003e \u003cli\u003eBattery safety insert\u003c\/li\u003e \u003cli\u003eQuick reference guide with QR code for instruction manual download\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cb\u003eWarranty\u003c\/b\u003e - Meter has 2 years. 6 months from date of purchase for electrodes and probes\u003c\/p\u003e \u003ch3\u003e\u003cspan\u003eMore accessories to buy separately\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eElectrodes\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-763100 Digital EC \/ temperature probe\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eMore solutions to buy separately\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eConductivity solutions\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-7030L 12880 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7030M 12880 µS\/cm calibration solution, 230 mL\u003c\/li\u003e \u003cli\u003eHI-7031L 1413 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7031M 1413 µS\/cm calibration solution, 230 mL\u003c\/li\u003e \u003cli\u003eHI-7033L 84 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7033M 84 µS\/cm calibration solution, 230 mL\u003c\/li\u003e \u003cli\u003eHI-7034L 80000 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7034M 80000 µS\/cm calibration solution, 230 mL\u003c\/li\u003e \u003cli\u003eHI-7035L 111800 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7035M 111800 µS\/cm calibration solution, 230 mL\u003c\/li\u003e \u003cli\u003eHI-7039L 5000 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7039M 5000 µS\/cm calibration solution, 230 mL\u003c\/li\u003e \u003cli\u003eHI-7037L 100% NaCl sea water standard solution, 500 mL\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eOther useful accessories\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-764026 Electrode holder for HI-2600 family\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eModels in the series\u003c\/span\u003e\u003c\/h3\u003e \u003cp\u003eHI-2600 pH, EC, DO Benchtop Meter with Data Logging \u003c\/p\u003e \u003cp\u003eHI-2620 pH and ORP Benchtop Meter \u003c\/p\u003e \u003cp\u003eHI-2621 pH and ORP Benchtop Meter with Data Logging\u003c\/p\u003e \u003cp\u003eHI-2630 EC \u0026amp; TDS Benchtop Meter \u003c\/p\u003e \u003cp\u003eHI-2631 EC, TDS and Salinity Benchtop Meter with Data Logging \u003c\/p\u003e \u003cp\u003eHI-2640 Dissolved Oxygen Benchtop Meter \u003c\/p\u003e \u003cp\u003eHI-2641 Dissolved Oxygen Benchtop Meter with Data Logging \u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eEC - using HI-763100 four-ring conductivity probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 29.99 µS\/cm;30.0 to 299.9 µS\/cm;300 to 2999 µS\/cm;3.00 to 29.99 mS\/cm;30.0 to 200.0 mS\/cm;up to 500.0 mS\/cm,and absolute conductivity (TDS) is the conductivity value without temperature compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm;0.1 µS\/cm;1 µS\/cm;0.01 mS\/cm;0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.5 µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eCell factor calibration; six standards available: 84µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 118.8 mS\/cm, one point offset: 0.00 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic, -5 to 100.0°C; NoTC, can be selected to measure absolute conductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00%\/°C (for EC and TDS only), default value is 1.90%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTDS - using HI-763100 four-ring conductivity probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.99 mg\/L (ppm);15.0 to 149.9 mg\/L (ppm);150 to 1499 mg\/L (ppm);1.50 to 14.99 g\/L;15.0 to 100.0 g\/L;up to 400.0 g\/L absolute TDS using 0.80 conversion factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm);0.1 mg\/L (ppm);1 (ppm);0.01 g\/L;0.1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.03 ppm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor in Standard Mode\u003c\/td\u003e\n\u003ctd\u003e0.40 to 0.80 (default value is 0.50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAdditional Specifications\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Interface\u003c\/td\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Interface\u003c\/td\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eUSB Type C (5 VDC; 500mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50˚C; Maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640058061173,"sku":"HI-2630-02","price":498.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-2630-conductivity-benchmeter.jpg?v=1791579974","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-2630-conductivity-benchtop-meter","provider":"Test All Water","version":"1.0","type":"link"}