{"product_id":"hanna-instruments-hi-2600-ph-ec-and-do-benchtop-meter","title":"Hanna Instruments HI-2600 pH EC and DO Benchtop meter","description":"\u003cp\u003eHI-2600 enables fast, accurate measurements of pH, ORP, conductivity, TDS, dissolved oxygen, salinity, and temperature utilising Hanna digital probes. HI-2600 can be used as a portable device for field measurements (using its rechargeable battery) or used in a laboratory.\u003c\/p\u003e \u003cp\u003eThe HI-2600 architecture brings together Hanna’s visionary design capabilities, integrated production, and world class research and development.\u003c\/p\u003e\u003ch3\u003e\u003cspan\u003eHI-2600 pH EC and DO Benchtop meter\u003c\/span\u003e\u003c\/h3\u003e \u003cp\u003eHI-2600 benchtop meter enables fast, accurate measurements utilising the Hanna Instruments digital electrode \/ probes for pH (HI-11310), ORP (HI-36180), conductivity (HI-763100), or dissolved oxygen (HI-764080). Each digital electrode \/ probe has a unique serial number and the parameter that it measures is automatically identified by the meter.\u003c\/p\u003e \u003cp\u003eOnce connected, the single sensor or sensors are ready to measure the parameter along with temperature.\u003c\/p\u003e \u003cp\u003eThe intuitive design simplifies configuration, calibration, measurement, data logging and transfer of data to a USB thumb drive or computer. The benchtop meter offers a Basic Mode that streamlines measurement configuration and is useful for routine applications.\u003c\/p\u003e \u003cp\u003eThe compact meter (and probe) can be used as a portable device (using its rechargeable battery) or used as laboratory instrumentation.\u003c\/p\u003e \u003cp\u003eThe meter has a large display with capacitive keys which features a 5.5” (14 cm) LCD. The large display provides a 130 ° wide viewing angle.\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eMain feature\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eAutomatic parameter recognition\u003c\/li\u003e \u003cli\u003epH\/ORP choice of measurement units: pH, mV;\u003c\/li\u003e \u003cli\u003eEC choice of measurement unit: Conductivity: µS\/cm, mS\/cm\u003c\/li\u003e \u003cli\u003eTDS - ppm (mg\/L), g\/L\u003c\/li\u003e \u003cli\u003eSalinity - NaCl, PSU, g\/L\u003c\/li\u003e \u003cli\u003eDO choice of measurement unit: ppm (mg\/L), %\u003c\/li\u003e \u003cli\u003eAdjustable resolution for pH and EC measurements\u003c\/li\u003e \u003cli\u003eCAL Check indicators - HI-11310, HI-763100, HI-764080 digital probes only\u003c\/li\u003e \u003cli\u003eSensor Check indicators - HI-11311 and HI-12301 digital probes only\u003c\/li\u003e \u003cli\u003eBasic mode for simplified operation\u003c\/li\u003e \u003cli\u003eDedicated GLP key\u003c\/li\u003e \u003cli\u003eGLP data included with logged data\u003c\/li\u003e \u003cli\u003eSimplified data transfer to a PC\u003c\/li\u003e \u003cli\u003eUp to 8 hour battery life when used as a portable device\u003c\/li\u003e \u003cli\u003eInternal clock and date\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e \u003cp\u003e\u003cb\u003eDigital probe input\u003c\/b\u003e - simply connect each probe via the 3.5 mm jack, Digital Smart Electrodes are automatically recognised.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eClear, full text readout\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e- The HI-2600 presents clear, detailed text prompts at the bottom section of the screen.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eTwo operating modes\u003c\/b\u003e - HI-2600 can be used in Standard or Basic Operating Modes (pH and EC only). Standard Mode enables all features while Basic Mode displays a simplified screen and features —ideal for routine measurements.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eData logging\u003c\/b\u003e - The HI-2600 provides ample data storage capacity, allowing you to save up to 1000 log records. Each data set comprehensively includes readings, GLP information, as well as date and time stamps.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eGLP\u003c\/b\u003e - The sensor retains data from the most recent calibration, including date, time, and buffers utilised. When connected to the HI-2600, this GLP information is automatically transferred.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eCAL Check\u003c\/b\u003e - Hanna’s exclusive CAL Check feature analyses the pH electrode’s response in calibration buffers to detect potential issues such as contaminated solutions or dirty electrodes. Upon completing calibration, indicators reflecting the probe’s condition—based on its offset and slope characteristics—are displayed on the measurement screen.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eSensor Check (using HI-11311 and HI-12301 pH probes only)\u003c\/b\u003e - When paired with compatible Hanna electrodes featuring a matching pin, HI-2600 continuously monitors the impedance of the pH measuring electrode, providing real-time alerts in case of glass breakage. During calibration, Sensor Check displays the junction condition, by evaluating the reference junction resistance.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eORP measurement\u003c\/b\u003e - Measure ORP (REDOX) in mV units by using a compatible ORP sensor.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eCapacitive touch keypad\u003c\/b\u003e - HI-2600 features sensitive capacitive touch buttons for accurate keystrokes for navigating menus and screens. Since they are part of the screen, the buttons can never get clogged with sample residue.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eEasy to read LCD\u003c\/b\u003e - HI-2600 features a 5.5” (14 cm) LCD display that you can clearly view from over 5 m (16.4’). The large display, with its wide 130° viewing angle, provides one of the easiest to read LCDs in the industry.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eRechargeable battery\u003c\/b\u003e - The integrated rechargeable battery offers maximum portability with a long 8-hour battery life.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eUSB-C port for charging and data transfer\u003c\/b\u003e - The HI-2600 features a streamlined USB-C port that facilitates charging the integrated rechargeable battery, transferring data to your computer, and exporting files directly to a flash drive.\u003c\/p\u003e \u003ch3\u003e\u003cspan\u003eWhat's included:\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-11310 pH digital electrode\u003c\/li\u003e \u003cli\u003eHI-764026 Electrode holder with the following accessories: base plate with integrated pivot pin; cable holder clip, attached\u003c\/li\u003e \u003cli\u003epH calibration kit: pH 4 buffer solution (2 sachets); pH 7 buffer solution (4 sachets); pH 10 buffer solution sachets (2 sachets)\u003c\/li\u003e \u003cli\u003eElectrode cleaning solution (2 sachets)\u003c\/li\u003e \u003cli\u003eHI-920018 - 1.5m USB-C to USB-C cable\u003c\/li\u003e \u003cli\u003eUSB-C power adapter\u003c\/li\u003e \u003cli\u003eInstrument quality certificate\u003c\/li\u003e \u003cli\u003eProbe \/ electrode quality certificate\u003c\/li\u003e \u003cli\u003eBattery safety insert\u003c\/li\u003e \u003cli\u003eQuick reference guide with QR code for instruction manual download\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cb\u003eWarranty\u003c\/b\u003e - Meter has 2 years. 6 months from date of purchase for electrodes and probes\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eMore accessories to buy separately\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eElectrodes\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-10530 Triple ceramic, double junction, glass body, refillable pH electrode with conical tip and temperature sensor\u003c\/li\u003e \u003cli\u003eHI-10430 Triple ceramic, double junction, glass body, refillable pH electrode with temperature sensor\u003c\/li\u003e \u003cli\u003eHI-11310 Glass body, double junction, refillable pH\/temperature electrode\u003c\/li\u003e \u003cli\u003eHI-11311 Glass body, double junction, refillable pH\/ temperature electrode with enhanced diagnostics\u003c\/li\u003e \u003cli\u003eHI-12300 Plastic body, double junction, gel filled, non-refillable pH \/ temperature electrode\u003c\/li\u003e \u003cli\u003eHI-12301 Plastic body, double junction, gel filled, non-refillable pH\/temperature electrode with enhanced diagnostics\u003c\/li\u003e \u003cli\u003eHI-36180 Glass body, double junction, refillable ORP\/temperature probe\u003c\/li\u003e \u003cli\u003eHI-763100 Digital EC \/ temperature probe\u003c\/li\u003e \u003cli\u003eHI-764080 Digital DO \/ temperature probe\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eMore solutions to buy separately\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003epH solutions – 500mL (other sizes available)\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-7001L pH 1.68 buffer solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7004L pH 4.01 buffer solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7006L pH 6.86 buffer solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7007L pH 7.01 buffer solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7009L pH 9.18 buffer solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7010L pH 10.01 buffer solution, 500 mL\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eORP solutions\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-7021L ORP test solution, 240 mV @ 25 °C, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7022L ORP test solution, 470 mV @ 25 °C, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7091L Reducing Pretreatment Solution, 500 mL bottle +14 g (set)\u003c\/li\u003e \u003cli\u003eHI-7092L Oxidizing Pretreatment Solution, 500 mL bottle\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003epH electrode maintenance solutions\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-70300L Storage solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-70000P Electrode rinse sachets (25 sachets × 20 mL)\u003c\/li\u003e \u003cli\u003eHI-7061L General cleaning solution, 500 mL\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eConductivity solutions\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-7030L 12880 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7031L 1413 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7033L 84 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7034L 80000 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7035L 111800 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7039L 5000 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7037L 100% NaCl sea water standard solution, 500 mL\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eDissolved oxygen solutions\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-7040L Zero oxygen solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7041S Polarographic dissolved oxygen electrolyte solution, 30 mL\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eOther useful accessories\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-764026 Electrode holder for HI-2600 family\u003c\/li\u003e \u003cli\u003eHI-764080A\/P Dissolved oxygen spare screw cap membranes for HI-764080 DO probe (5 pcs.)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eModels in the series\u003c\/span\u003e\u003c\/h3\u003e \u003cp\u003eHI-2600 pH, EC, DO Benchtop Meter with Data Logging \u003c\/p\u003e \u003cp\u003eHI-2620 pH and ORP Benchtop Meter \u003c\/p\u003e \u003cp\u003eHI-2621 pH and ORP Benchtop Meter with Data Logging\u003c\/p\u003e \u003cp\u003eHI-2630 EC \u0026amp; TDS Benchtop Meter \u003c\/p\u003e \u003cp\u003eHI-2631 EC, TDS and Salinity Benchtop Meter with Data Logging \u003c\/p\u003e \u003cp\u003eHI-2640 Dissolved Oxygen Benchtop Meter \u003c\/p\u003e \u003cp\u003eHI-2641 Dissolved Oxygen Benchtop Meter with Data Logging \u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003epH - using HI-11310 pH electrode\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003ebasic mode: -2.00 to 16.00 pH; standard mode: -2.000 to 16.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003ebasic mode: 0.01 pH; standard mode: 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003ebasic mode: ±0.01 pH; standard mode: ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eBasic Mode: Automatic, up to three points, option to select 5 standard buffers.Standard mode: Automatic, up to five point calibration, 7 standard buffers available and two custom buffers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic, -5.0 to 100.0°C (using integral temperature sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003eUp to 1000* (in Standard Mode) records organised in:• Manual log-on demand, maximum 200 logs• Manual log-on-stability, maximum 200 logs• Interval logging in Standard Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003emV - using HI-11310 pH electrode\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV pH Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eORP – using HI-36180 ORP electrode\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV (±999.9mV); ±1mV (±2000mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic, using integral temperature sensor -5.0 to 100.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003eUp to 1000* (in Standard Mode) records organised in:• Manual log-on demand, maximum 200 logs• Manual log-on-stability, maximum 200 logs• Interval logging in Standard Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eEC - using HI-763100 four-ring conductivity probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 29.99 µS\/cm;30.0 to 299.9 µS\/cm;300 to 2999 µS\/cm;3.00 to 29.99 mS\/cm;30.0 to 200.0 mS\/cm;up to 500.0 mS\/cm,and absolute conductivity (TDS) is the conductivity value without temperature compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm;0.1 µS\/cm;1 µS\/cm;0.01 mS\/cm;0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.5 µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eCell factor calibration; six standards available: 84µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 118.8 mS\/cm, one point offset: 0.00 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic, -5 to 100.0°C; NoTC, can be selected to measure absolute conductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00%\/°C (for EC and TDS only), default value is 1.90%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003eUp to 1000* (400) records organised in:• Manual log-on demand, maximum 200 logs• Manual log-on-stability, maximum 200 logs• Interval logging in Standard Mode, maximum 600 logs (100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTDS - using HI-763100 four-ring conductivity probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.99 mg\/L (ppm);15.0 to 149.9 mg\/L (ppm);150 to 1499 mg\/L (ppm);1.50 to 14.99 g\/L;15.0 to 100.0 g\/L;up to 400.0 g\/L absolute TDS using 0.80 conversion factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm);0.1 mg\/L (ppm);1 (ppm);0.01 g\/L;0.1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.03 ppm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor in Standard Mode\u003c\/td\u003e\n\u003ctd\u003e0.40 to 0.80 (default value is 0.50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eSalinity - using HI-763100 four-ring conductivity probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0 % NaCl; 2.00 to 42.00 PSU; 0.00 to 80.00 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 % NaCl; 0.01 PSU; 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration % NaCl only\u003c\/td\u003e\n\u003ctd\u003eone point with HI-7037 standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDissolved Oxygen - using HI-764080 DO Probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 PPM (mg\/L); 0.0 to 300.0% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm (mg\/L); 0.1% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading (± 1 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eone or two point at 0% (HI-7040L solution) and 100% (water-saturated air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic 450.0 to 850.0 mmHg – (0.1 mmHg resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L – (1g\/L resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 records organised in:• Manual log-on-demand, maximum 200 logs• Manual log-on-stability, maximum 200 logs• Interval logging in Standard Mode, maximum 600 logs (100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAdditional Specifications\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Interface\u003c\/td\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Interface\u003c\/td\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eUSB Type C (5 VDC; 500mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50˚C; Maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003eHI-2600 pH\/EC\/DO benchtop meter includes HI-11310 glass body refillable pH electrode, pH 4 buffer solution sachets (2), pH 7 buffer solution sachets (4), pH 10 buffer solution sachets (2), electrode cleaning solution sachets (2), electrode holder, 1.5 m USB-C to C USB-C cable. All HI-2600 series compatible pH, EC and DO digital probes are interchangeable with HI-2600 and can be ordered separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640057962869,"sku":"HI-2600-02","price":470.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-2600-ph-ec-and-do-benchmeter.jpg?v=1791579970","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-2600-ph-ec-and-do-benchtop-meter","provider":"Test All Water","version":"1.0","type":"link"}