{"product_id":"hanna-instruments-hi-2003-edge-conductivity-meter","title":"Hanna Instruments HI-2003 Edge Conductivity Meter","description":"\u003cp\u003eedge® EC is dedicated to testing Conductivity. Using Hanna's latest technology and design, edge® can be adapted to suit your working method.\u003c\/p\u003e \u003cp\u003eSelect from hand held, wall mount or bench top - or switch between them all. edge® is happy any which way. Simply plug in the electrode, then play.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eMeasurement is simpler, quicker and more accurate than ever.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eResults are fast and reliable. Combining high precision technology with the user-friendly dimensions and format of a small digital tablet, edge® is breaking new ground in electrochemistry.\u003c\/p\u003e \u003cp\u003eThis is a must-have meter for your laboratory.\u003c\/p\u003e \u003cp\u003eCutting-edge design, capacitive touch keypad and an intuitive user interface are just a few of the great attributes that make edge® stand out as the world's first Hybrid meter on the market.\u003c\/p\u003e \u003ch3\u003eKey features\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e4-ring potentiometric probe - covers all ranges from 0.00µS\/cm to 500 mS\/cm (absolute EC)\u003c\/li\u003e \u003cli\u003eAccuracy - ±1% of the reading (±0.05µS\/cm or 1 digit, whichever is greater)\u003c\/li\u003e \u003cli\u003eCalibration - offset (0 µS\/cm) and cell factor calibration, choice of 5 standards\u003c\/li\u003e \u003cli\u003eAuto-ranging or manual range selection\u003c\/li\u003e \u003cli\u003eEC, TDS and Salinity reading modes\u003c\/li\u003e \u003cli\u003eTemperature compensation - automatic, NoTC (absolute)\u003c\/li\u003e \u003cli\u003eGLP data - records date, time, offset, and cell constant value (K)\u003c\/li\u003e \u003cli\u003eAdjustable EC to TDS conversion factor\u003c\/li\u003e \u003cli\u003eAdjustable temperature correction factor\u003c\/li\u003e \u003cli\u003eCapacitive touch keys\u003c\/li\u003e \u003cli\u003eLarge 140mm LCD display with clear full text readout\u003c\/li\u003e \u003cli\u003eDigital smart electrodes enable edge to automatically recognise and store sensor type, ID and calibration information - with 3.5mm phono connection\u003c\/li\u003e \u003cli\u003eProgrammed for basic and advanced modes\u003c\/li\u003e \u003cli\u003eLog-on demand and interval logging\u003c\/li\u003e \u003cli\u003ePC interface via micro USB\u003c\/li\u003e \u003cli\u003eData download onto USB stick via standard USB\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 29.99 µS\/cm; 30.0 to 299.9 µS\/cm; 300 to 2999 µS\/cm; 3.00 to 29.99 mS\/cm; 30.0 to 200.0 mS\/cm; up to 500.0 mS\/cm absolute EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm; 0.1 µS\/cm; 1 µS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.5 µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003esingle cell factor calibration; six standards available: 84µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 118.8 mS\/cm, one point offset: 0.00 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00%\/°C (for EC and TDS only), default value is 1.90%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.99 mg\/L (ppm); 15.0 to 149.9 mg\/L (ppm); 150 to 1499 mg\/L (ppm); 1.50 to 14.99 g\/L; 15.0 to 100.0 g\/L; up to 400.0 g\/L absolute TDS using 0.80 conversion factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 mg\/L (ppm); 1 (ppm); 0.01 g\/L; 0.1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.03 ppm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor\u003c\/td\u003e\n\u003ctd\u003e0.40 to 0.80 (default value is 0.50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0 % NaCl; 2.00 to 42.00 PSU; 0.0 to 80.0 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 % NaCl; 0.01 PSU; 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003ePSU and g\/L through EC calibration; % NaCl - one point with HI-7037 sea water standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAdditional Specifications:\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003eHI-763100 digital four-ring conductivity probe with 3.5 mm connector and 1m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003eup to 1000 (400 for basic mode) records organised in: manual log-on demand (max. 200 logs), manual log-on stability (max. 200 logs), interval logging (max. 600 samples; 100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 USB port for storage; 1 micro USB port for charging and PC connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C; RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2020 x 140 x 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e250 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e4-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulator\u003c\/td\u003e\n\u003ctd\u003eglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrodes\u003c\/td\u003e\n\u003ctd\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Conditions\u003c\/td\u003e\n\u003ctd\u003e-5 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\u003c\/td\u003e\n\u003ctd\u003e120mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther\u003c\/td\u003e\n\u003ctd\u003eUnique serial ID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003e3.5mm jack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/modules\/teapotknowledgehub\/uploads\/manedgeec_2003_10_16-60dae26087674.pdf\" target=\"_blank\"\u003eHI-2003 Edge Conductivity Meter (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640057012597,"sku":"HI-2003-02","price":717.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-2003-02-edge-reg-ec-hybrid-meter.jpg?v=1791579939","url":"https:\/\/testallwater.co.uk\/products\/hanna-instruments-hi-2003-edge-conductivity-meter","provider":"Test All Water","version":"1.0","type":"link"}