Hanna Instruments-96733C Ammonia Portable Photometer Kit, High Range

Hanna InstrumentsSKU: HI-96733C
filler

Price:
Sale price£586.41

Shipping calculated at checkout

Stock:
Re-stocking soon, contact us to confirm date

Description





Kit including Hanna Instruments-96733 photometer - hard carrying case, 2 sample cuvettes, scissors, cuvette cleaning cloth, battery, instruction manual and CAL CHECK standards for ammonia HR.


Portable photometers are for the measurement of ammonia nitrogen in fresh and salt water samples.









Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.





Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.



Hanna Instruments-96733C Ammonia Portable Photometer Kit, High Range


Kit including Hanna Instruments-96733 photometer, hard carrying case, 2 sample cuvettes, cuvette cleaning cloth, battery, instruction manual and CAL CHECK standards for ammonia HR. Testing reagents sold separately.


Portable photometer are for the measurement of ammonia nitrogen in freshwater samples. Present naturally in surface and wastewaters, ammonia mainly results from the deamination of organic nitrogen-containing compounds and hydrolysis of urea. Ammonia may also be present from water treatment processes that utilise chloramines for disinfection, where ammonia is added to the water to react with chlorine. Ammonia is less likely to appear in groundwater due to absorption to soil particles.



  • CAL Check - Allows for performance verification and calibration of the meter using NIST traceable standards

  • GLP – Review of the last calibration date

  • Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally left on

  • Battery status indicator – Indicates the amount of battery life left

  • Built-in timer – Display of time remaining before a measurement is taken. Ensures that all reading are taken at the appropriate reaction intervals for the test being performed

  • Error message – Messages on display alerting to problems including no cap, high zero, and standard too low

  • Cooling lamp indicator – To maintain the desirable wavelength to be used for absorbance, it is necessary to ensure components are not overheated from the heat generated by the tungsten lamp. Each photometer is designed to allow a minimal amount of time for components to cool. The cooling lamp indicator is displayed prior to a reading being taken

  • Units of measurement – Appropriate unit of measure is displayed along with reading