{"product_id":"hach-tl2300-tungsten-lamp-turbidimeter-epa-0-4000-ntu","title":"HACH TL2300 Tungsten Lamp Turbidimeter, EPA, 0 - 4000 NTU","description":"\u003cp class=\"p-large mb-2\"\u003eTrust the TL2300 Turbidimeter for dependable, precise measurements and accurate turbidity testing\u003c\/p\u003e\n\u003cdiv class=\"overview-item\"\u003e\n\u003cp\u003eAchieve precise turbidity measurements across a wide range of water qualities while ensuring it meets EPA Method 180.1 with the TL2300 Laboratory Turbidimeter. Designed for simplicity, accuracy, and reliability, this benchtop turbidimeter streamlines water quality testing. Equipped with a tungsten lamp, the TL2300 delivers consistent results across a wide range of 0–4000 NTU and meets the requirements of EPA Method 180.1.\u003cbr\u003e\u003cbr\u003e• Reduce errors and eliminate uncertainty with accurate turbidity measurements instantly, thanks to automatic sample stability detection.\u003cbr\u003e• Minimize mistakes and ensure accurate results with the intuitive color touchscreen and clear, step-by-step instructions—helping every user follow best practices and achieve consistent measurements.\u003cbr\u003e• Reduce downtime and improve efficiency with quick USB data export and proactive self-diagnostics—keeping your workflow smooth and your instrument ready when you need it.\u003cbr\u003e• Rely on performance and robust construction designed to deliver repeatable, reliable results—even during high sample volumes or demanding laboratory schedules.\u003cbr\u003e\u003cbr\u003eChoose the TL2300 Lab Turbidimeter for consistent results and reliable EPA compliance. Count on it to streamline your water quality testing, providing the accuracy and efficiency your lab needs to deliver reliable results with confidence.\u003c\/p\u003e\n\u003ch2 id=\"benefits\" class=\"h3 secondMenu\" title=\"Benefits\"\u003eBenefits\u003c\/h2\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6 clearfix\"\u003e\n\u003ch3 class=\"h4\"\u003e\u003cstrong\u003eImproved and intuitive design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TL23 Series’ large full colour touch screen display and intuitive user interface accelerate setup, calibration and measurement. An easy interface and guided procedures give you confidence in your results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 clearfix\"\u003e\n\u003ch3 class=\"h4\"\u003e\u003cstrong\u003eA smart device for more reliable measurements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TL23 Series ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability. This quality step removes subjectivity and the need for repeated measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 clearfix\"\u003e\n\u003ch3 class=\"h4\"\u003e\u003cstrong\u003eEasy to use. Easy to Be Right\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TL23 Series provides everything you need at your fingertips. With a USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance, Hach\u003csup\u003e®\u003c\/sup\u003e makes it easy to Be Right.\u003c\/p\u003e\n\u003ch2 class=\"h3 secondMenu\" title=\"Specifications\" id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"ec-icon\"\u003e\n\u003ci class=\"fas fa-chevron-up\" data-alt-class=\"fas fa-chevron-down\"\u003e\u003c\/i\u003e \u003c\/div\u003e\n\u003ch2 class=\"h5 ec-header\" data-expand-collapse=\"true\" data-expand-collapse-target=\"ec-specs-0\"\u003eTechnical Attributes\u003c\/h2\u003e\n\u003cdiv id=\"ec-specs-0\" class=\"mb-2\"\u003e\n\u003ctable class=\"specifications-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eRatio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU based on formazin primary standard\u003cbr\u003e\u003cbr\u003eRatio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eAir purge\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eDry nitrogen or instrument grade air (ANSI MC 11.1, 1975)\u003cbr\u003e0.05 L\/s at 69 kPa (10 psig); 138 kPa (20 psig) max\u003cbr\u003eHose barb connection for 1\/8-inch tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eCertifications\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eCE, KC, RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eCommunication\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eCompliance\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eEPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eData logging\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e2000 total logs, includes reading log, verification log and calibration log\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e153 mm x 395 mm x 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e17.8 mm colour touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eInterface\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e2 USB-A ports for USB flash drive, external thermal printer, keyboard and barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eLight source\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eTungsten filament lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eMeasurement method\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eNephelometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e0 - 4000 NTU (EPA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eNTU (Ratio on): 0 - 4000\u003cbr\u003e\u003cbr\u003eNTU (Ratio off): 0 - 40\u003cbr\u003e\u003cbr\u003eEBC (Ratio on): 0 - 980\u003cbr\u003e\u003cbr\u003eEBC (Ratio off): 0 - 9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eTL2300 EPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e0 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003ePower requirements (Amps)\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e3.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003ePower requirements (Hz)\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003ePower requirements (Voltage)\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e100 - 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eReading modes\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eSingle, continuous, Rapidly Settling Turbidity, signal averaging on or off, ratio on or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eMeets EPA Method 180.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e±1% of reading or 0.01 NTU, whichever is greater (under reference conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eResponse time\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eSignal averaging off: 6.8 seconds \/ Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eSample Cell Compatibility\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eRound cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eSample requirements\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e25 mm sample cell: 20 mL minimum\u003cbr\u003e0 to 70 °C (32 to 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eSource lamp\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eTungsten Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eStabilisation time\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eRatio on: 30 minutes after start-up\u003cbr\u003e\u003cbr\u003eRatio off: 60 minutes after start-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eStorage conditions\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e-20 - 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eUnits\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eNTU and EBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e24 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-specs\"\u003eWhat's included?\u003c\/td\u003e\n\u003ctd class=\"text-specs\"\u003eTL2300 Turbidimeter, silicone oil, oiling cloth, USEPA filter assembly, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Hach","offers":[{"title":"Default Title","offer_id":57699094593909,"sku":"LPV444.99.00210","price":5340.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/LPV4449900210_Turb-Lab-TL2300-LZ.webp?v=1793175083","url":"https:\/\/testallwater.co.uk\/products\/hach-tl2300-tungsten-lamp-turbidimeter-epa-0-4000-ntu","provider":"Test All Water","version":"1.0","type":"link"}