{"title":"Process Water and Water Quality","description":null,"products":[{"product_id":"hanna-instruments-83306-02-multi-parameter-environmental-analysis-photometer-with-ph-meter","title":"Hanna Instruments-83306-02 Multi-parameter Environmental Analysis Photometer with pH meter","description":"One meter can be used for both photometric and pH measurements. Hanna Instruments-83306 is a compact, multi-parameter photometer for use in the environmental lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 23 different programmed methods measuring 16 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. Environmental parameters include nitrate, phosphorous and dissolved oxygen.\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHanna Instruments-83306-02 Environmental Analysis Photometer with pH digital input \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe photometer features an innovative optical system that uses LEDs, narrow band interference filters, a focusing lens, and a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source which ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83306 was developed to measure the most common parameters in environmental water quality monitoring. Nutrients such as nitrates and phosphates are key indicators of nutrient pollution from agricultural sources and are considered dangerous to environmental waters. Too few nutrients and waters will be unable to sustain healthy ecosystems; too many nutrients and algal blooms can form, which can be detrimental to water quality and aquatic health. Dissolved oxygen is an essential to performing biological processes for many forms of aquatic life, such as fish, plants and microorganisms.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83306 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the four wavelengths of light (420 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability, the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eKey features: \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHigh Efficiency LED Light Source\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHigh Quality Narrow Band Interference Filters \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eReference Detector for a Stable Light Source \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eLarge Cuvette Size \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eFocusing Lens for Greater Light Yield \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354373075095,"sku":"HI-83306-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83306-02_multi-parameter_environmental_analysis_photometer_with_ph_meter_357082fd-4ba0-4d5e-8514-04ae70880382.jpg?v=1624278761"},{"product_id":"hanna-instruments-83303-02-aquaculture-multi-parameter-photometer-with-ph-meter","title":"Hanna Instruments-83303-02 AquaCulture Multi-parameter Photometer with pH Meter","description":"One meter can be used for both photometric and pH measurements. The meter has 20 different programmed methods measuring 12 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003cbr\u003e\u003ch3\u003eHanna Instruments-83303 Aquaculture Photometer with pH meter\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable benchtop space, the Hanna Instruments-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input. Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMade with the aquaculture industry in mind, the Hanna Instruments-83303 is a comprehensive solution to maintaining optimal chemical and environmental conditions, preventing disease and increasing production.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 measures vital parameters such as Alkalinity, Calcium, Nitrite, and Phosphate. Alkalinity plays a part in a dynamic relationship with pH and CO2 concentrations, high alkalinity water lowers fluctuations in pH. The buffering capacity acts to store extra CO2 essential for photosynthesis in the ponds to produce oxygen. Maintaining calcium at certain levels is vital to proper fish growth and development. Excessive nitrite can be toxic to fish. When nitrite interacts with Haemoglobin, the iron becomes oxidised and the blood cell can no longer carry oxygen. Phosphate is essential to plant growth; too much phosphate in an aquaculture system can contribute to algal blooms decreasing dissolved oxygen vital for a successful ecosystem.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83303 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375336087,"sku":"HI-83303-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_2_82e0c6fb-4e30-4e5b-9e18-bcb58add9261.jpg?v=1624278828"},{"product_id":"hanna-instruments-83300-02-multi-parameter-benchtop-photometer-ph-meter","title":"Hanna Instruments-83300-02 Multi-parameter Benchtop Photometer \u0026 pH meter","description":"One meter can be used for both photometric and pH measurements. The meter has 60 different programmed methods measuring 37 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83300 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003cbr\u003e\u003ch3\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-83300 is a compact, multi-parameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFrom Aluminium to Zinc, the Hanna Instruments-83300 benchtop photometer measures 37 water quality parameters using 60 different methods. The photometer features an innovative optical system that uses LEDs, narrow band interference filters, and a focusing lens. It also has a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83300 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375467159,"sku":"HI-83300-02","price":1489.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_3_dc75fef9-64f1-4563-8b90-e8a5f746505a.jpg?v=1624278832"},{"product_id":"hanna-instruments-83325-02-multi-parameter-photometer-with-ph-meter-for-plant-nutrient-analysis","title":"Hanna Instruments-83325-02 Multi-parameter Photometer with pH meter for Plant Nutrient analysis","description":"\u003cp\u003eOne meter can be used for both photometric and pH measurements. The Hanna Instruments-83325 benchtop photometer measures 8 different plant nutrient water quality parameters using 9 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time. Key parameters are: Ammonia, Calcium, Magnesium, Nitrate, Phosphorus, Potassium, Sulphate and pH.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eHanna Instruments-83325-02 Plant Nutrient Analysis Photometer with pH meter\u003c\/h3\u003e\n\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/p\u003e\n\u003cp\u003eConsistent and thorough monitoring of plant nutrients is essential to maintaining healthy growth and reproduction. This is easy with the Hanna Instruments-83325, a comprehensive way to monitor vital plant nutrients such as potassium, calcium and magnesium. Required in large quantities, potassium plays a vital role in water uptake and enzyme regulation. Calcium helps to strengthen plant cell walls protecting against heat stress while magnesium helps build a strong immune system.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83325 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the three wavelengths of light (420 nm, 466 nm, and 525 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch3\u003eKey features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cli\u003eError Messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354376482967,"sku":"HI-83325-02","price":853.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_4_244ef4df-8e10-4227-a272-550e2bc9fb4e.jpg?v=1624278870"},{"product_id":"hanna-instruments-83308-water-conditioning-photometer-with-ph-meter","title":"Hanna Instruments-83308 Water Conditioning Photometer with pH meter","description":"\u003cp\u003eOne meter can be used for both photometric and pH measurements. This meter has 23 different programmed methods measuring 15 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. Water conditioning parameters include Fluoride, Chlorine, Ammonia, Manganese, Copper, Iron, Silver and Zinc.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 benchtop photometer measures 15 different key water quality parameters using 23 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 was developed to measure the most common parameters in water quality monitoring. One important parameter to test water quality is iron since it can affect colour, odour, and turbidity and can also be the most troublesome factor for appliances and surfaces in contact with water. High levels of iron in water can result in clogged water pipes or heat exchangers.\u003c\/p\u003e\n\u003cp\u003eAdditionally, Ammonia detection in water treatment systems is particularly important for aquarium owners and fish farm operators since ammonia is highly soluble in water and extremely toxic to fish. One other important parameter in water quality monitoring is Fluoride. Fluoride is best known for preventing tooth decay. While it does help prevent tooth decay, too little fluoride can be ineffective while too much can cause staining of teeth.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the four wavelengths of light (420 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch3\u003eKey features:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eError Messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Focusing Lens for Greater Light Yield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\n\u003cdiv id=\"product_tabs\" class=\"product__tabs\"\u003e\n\u003cdiv class=\"tabs\"\u003e\n\u003cdiv class=\"tab specification active\"\u003e\n\u003cdiv class=\"tab__content\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pH electrode input and 4 photometer wavelengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital pH electrode (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLog on demand with user name and sample ID optional input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-A host for flash drive; micro-USB-B for power and computer connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibration data for connected pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 VDC Li-polymer rechargeable battery\/ \u0026gt;500 photometric measurements or 50 hours of continuous pH measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e206 x 177 x 97mm (8.1 x 7.0 x 3.8\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon Photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e8nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter wavelength accruacy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e+-1nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRound, 24.6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Methods\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-83308 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAMMONIA\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 3.00 mg\/L (as NH3-N) Medium Range: 0.00 to 10.00 mg\/L (as NH3-N) High Range: 0.0 to 100.0 mg\/L (as NH3-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading Medium Range: ±0.05 mg\/L ±5% of reading High range: ±0.5 mg\/L ±5% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCHLORINE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA 330.5 DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCOPPER\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.500 mg\/L (as Cu2+) High range: 0.00 to 5.00 mg\/L (as Cu2+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±5% of reading High Range ±0.02 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFLUORIDE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as F-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIRON\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.600 mg\/L (as Fe) High Range: 0.00 to 5.00 mg\/L (as Fe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±8% of reading High Range: ±0.04 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the TPTZ Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMANGANESE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 300 µg\/L (as Mn) High range: 0.0 to 20.0 mg\/L (as Mn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.02 mg\/L ±3% of reading; High Range: ±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMOLYBDENUM\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 40.0 mg\/L (as Mo6+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the mercaptoacetic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNICKEL\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.000 mg\/L (as Ni); High Range: 0.00 to 7.00 g\/L (as Ni)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow range: ±0.010 mg\/L ±7% of reading High Range: ±0.07 g\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN method; High Range: Adaptation of the photometric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNITRATE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L (as NO3-- N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±10% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the cadmium reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOXYGEN, DISSOLVED\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L (as O2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.4 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003epH\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 0.1 pH pH electrode: 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: ±0.1 pH pH electrode: ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eclean electrode and check buffer\/check probe displayed during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: phenol red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePHOSPHATE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.50 mg\/L (as PO43-) High range: 0.0 to 30.0 mg\/L (as PO43-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading High Range: ±1 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the Ascorbic Acid method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSILICA\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as SiO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSILVER\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.000 mg\/L (as Ag)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.020 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the PAN method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eZINC\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.00 mg\/L (as Zn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eREAGENTS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia HR, MR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93733-01 (100 tests); HI-93733-03 (300 tests); MR - HI-93715-01 (100 tests); HI-93715-03 (300 tests); LR - HI-93700-01 (100 tests); HI-93700-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine - Free\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Total\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)\u003cbr\u003eChlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93702-01 (100 tests); HI-93702-03 (300 tests)\u003cbr\u003eLR - HI-95747-01 (100 tests); HI-95747-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93739-01 (100 tests); HI-93739-03 (300 tests)\u003cbr\u003eLR - HI-93729-01 (100 tests); HI-93729-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93721-01 (100 tests); HI-93721-03 (300 tests)\u003cbr\u003eLR - HI-93746-01 (100 tests); HI-93746-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93709-01 (100 tests); HI-93709-03 (300 tests)\u003cbr\u003eLR - HI-93748-01 (50 tests); HI-93748-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93730-01 (100 tests); HI-93730-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel - HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93726-01 (100 tests); HI-93726-03 (300 tests)\u003cbr\u003eLR - HI-93740-01 (50 tests); HI-93740-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93728-01 (100 tests); HI-93728-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved (DO)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93732-01 (100 tests); HI-93732-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93710-01 (100 tests); HI-93710-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate - HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93717-01 (100 tests); HI-93717-03 (300 tests)\u003cbr\u003eLR - HI-93713-01 (100 tests); HI-93713-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica – LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLR - HI-93705-01 (100 tests); HI-93705-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93737-01 (50 tests); HI-93737-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93731-01 (100 tests); HI-93731-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354377793687,"sku":"HI-83308-02","price":717.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83308_water_conditioning_photometer_with_ph_meter_65bd256c-bf7f-4276-8991-38095b909212.jpg?v=1624278907"},{"product_id":"hanna-instruments-83305-02-multi-parameter-photometer-ph-meter-for-boiling-and-cooling-towers","title":"Hanna Instruments-83305-02 Multi-parameter Photometer \u0026 pH Meter for Boiling and Cooling towers","description":"One meter can be used for both photometric and pH measurements. The meter has 30 different programmed methods measuring 18 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves.\u003cbr\u003e\u003ch3\u003eHanna Instruments-83305-02 Boiler and Cooling Tower Photometer with pH digital input\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable benchtop space, the Hanna Instruments-83305 doubles as a professional pH meter with its digital pH\/temperature electrode input. Suitable for use in boiling and cooling tower applications, parameters specific to boiling and cooling towers include oxygen scavengers and silica which are important for maintaining equipment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable laboratory benchtop space, the Hanna Instruments-83305 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis photometer features an innovative optical system that uses LEDs, narrow band interference filters, a focusing lens, plus a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source which ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eSpecifically designed for use with boilers and cooling towers, the Hanna Instruments-83305 is a comprehensive way to maintain precise water conditions in systems. Problems such as corrosion, deposition, and microbial growth can occur if these key parameters, such as oxygen scavengers and silica, aren't maintained. Oxygen scavengers are added to remove residual dissolved oxygen in boiler feed water that can cause corrosion in a steam generating plant. It is important that levels of oxygen scavengers be routinely checked to prevent against corrosion and ensure that equipment is working efficiently. Boiler water maintenance is necessary to prevent or control deposit formation as seen with silica. Silica contamination can reduce system efficiency and increase maintenance of equipment due to scaling.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built-in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built-in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83305 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability, the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354378645655,"sku":"HI-83305-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83305-02_multi-parameter_photometer_ph_meter_for_boiling_and_cooling_towers_181f2f4b-06e5-4b51-9be1-abf10313a96a.jpg?v=1624278958"},{"product_id":"hanna-instruments-83749-02-portable-turbidity-meter-and-bentonite-monitoring","title":"Hanna Instruments-83749-02 Portable Turbidity Meter and bentonite monitoring","description":"The portable turbidity meter and bentonite monitoring system measures turbidity of samples from 0.00 to 1200 NTU (Nephelometric Turbidity Units) and is USEPA compliant. Wines with low phenol contents, such as rose, light reds and whites should be checked for protein stability before bottling.\u003cbr\u003e\u003ch3\u003eHanna Instruments-83749-02 Portable Turbidity Meter\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eWines with low phenol contents, such as rose, light reds and whites should be checked for protein stability before bottling. Hanna offers a quick test meter to verify the risk of future protein haze formation. If protein instability is detected, a subsequent test can help define the right amount of bentonite to be added for improving protein stability. It is important not to overdose bentonite to avoid stripping wine flavour, body and significant loss of colour, especially in young red wines.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMoreover, adding only the necessary amount of bentonite to obtain the desired protein stability also saved costs.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83749 measures turbidity of samples from 0.00 to 1200 NTU (Nephelometric Turbidity Units) and is USEPA compliant. In the USEPA measurement mode the instrument rounds the readings to meet USEPA reporting requirements.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOther features include:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eGLP features\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit LCD\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003ePC Interface via USB\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eFast Tracker™\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83749 is equipped with Fast Tracker™ Tag Idenfication System (TIS) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of specific measurement or series of measurements using iButton® tags near sampling points for quick and easy readings. Each iButton® tag contains a computer chip with a unique identification code encased in stainless steel\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354379268247,"sku":"HI-83749-02","price":1447.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83749-02_portable_turbidity_meter_and_bentonite_monitoring_b504e5ec-928a-4613-ae63-d9e10a3dcbe2.jpg?v=1624278976"},{"product_id":"hanna-instruments-7871-220-mini-level-controller-control-relay-high-and-low-220v","title":"Hanna Instruments-7871\/220 Mini Level Controller, control relay: high and low, 220V","description":"Hanna Instruments-7871 mini-level controller is ideal for liquid level control over distances of up to 100 meters (330 feet). It is highly compact and will fit in tight spaces.\u003cbr\u003e\u003ch3\u003eMini Level Controller, control relay: high and low, 220, 240V\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThese easy-to-use controllers are ideal for nearly any liquid level application, such as industrial and municipal water treatment, nutrient tank control in farming, hydroponics, aquaculture applications and plating rinse baths.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-7871 includes an overflow alarm and can be connected to a 2-wire transmitter, which is ideal for level monitoring in remote applications.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA complete liquid level measuring system requires:\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eController (Hanna Instruments-7871)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003ebar holder with amplifier circuitry (Hanna Instruments-7874)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eMeasuring bars (Hanna Instruments-731324)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUndecal connector (Hanna Instruments-7164)\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-7871 requires four bars with the additional bar used for overflow measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information:\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-7871 is supplied with mounting brackets and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354380480663,"sku":"HI-7871\/220","price":127.78,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-787120_mini_level_controller_control_relay_high_and_low_220v.jpg?v=1624279023"},{"product_id":"hanna-instruments-943500d-conductivity-controller-low-range-199-9-µs-cm","title":"Hanna Instruments-943500D Conductivity Controller (Low Range @ 199.9 µS\/cm)","description":"Hanna Instruments-943500 are panel-mounted conductivity controllers designed for simplicity of use in a wide range of industrial process applications. Four different models are available with different measurement ranges, to satisfy any application requirements.\u003cbr\u003e\u003cp\u003eFour different models are available with different measurement ranges, to satisfy any application requirements.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe output configuration for connecting a recorder or a PLC can be chosen between 0-20 or 4-20 mA.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe LED on the front panel indicates the operating status of the controller.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe automatic temperature compensation (ATC) is performed directly by the Hanna Instruments-7638 probe with built-in temperature sensor.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe front panel is protected behind a transparent splash-proof cover.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information:\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-943500 series is supplied with mounting brackets and instructions.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500A: 0.0 to 199.9 mS\/cm\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500B: 0.00 to 19.99 mS\/cm\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500C: 0 to 1999 µS\/cm\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500D: 0.0 to 199.9 µS\/cm\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354380578967,"sku":"HI-943500D","price":756.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-943500d_conductivity_controller_low_range_199.9_scm_0a23d3d4-993d-4a95-8dd7-77731bc238f0.jpg?v=1624279024"},{"product_id":"bl-983320-0-conductivity-mini-controller-range-199-9-µs-cm","title":"Hanna Instruments Conductivity Mini Controller (Range 199.9 µS\/cm) BL-983320-0","description":"The Hanna mini controllers have been specially designed for water conditioning and growing applications. The BL-983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 μS\/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. Compact in size, they can be mounted in confined spaces or even right next to the vat or barrel containing the chemicals.\u003cbr\u003e\n\u003cp\u003eWhen in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionised) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL-983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.\u003c\/p\u003e\n\u003ch3\u003eAdjustable Dry Contact Dosing Relay\u003c\/h3\u003e\n\u003cp\u003eThe BL-983320 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch3\u003eProgrammable Overdose Protection\u003c\/h3\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch3\u003eRelay Control Override\u003c\/h3\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch3\u003eMulticolour LED Indicator\u003c\/h3\u003e\n\u003cp\u003eMulticolour LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFuse Protected Dosing Contacts\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLabelled Termination Connections\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQuick-connect terminal blocks are clearly labelled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe BL-983320 mini controller uses the HI-7634-00 conductivity probe that is available with different cable lengths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*HI-7634-00 is not included and must be ordered separately\u003c\/p\u003e\n\u003ch3\u003eOrder Information:\u003c\/h3\u003e\n\u003cp\u003eThe BL-983320 is supplied with mounting brackets, transparent cover, and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354386411671,"sku":"BL-983320-0","price":231.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983320-0_conductivity_mini_controller_range_199.9_scm_f2017210-2133-4214-a3fa-72bca529132b.jpg?v=1624279134"},{"product_id":"hanna-instruments-4111-iodine-combination-electrode","title":"Hanna Instruments-4111 Iodine Combination Electrode","description":"The Hanna Instruments-4111 is ideal for a variety of applications in food production and environmental monitoring.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4111 iodide selective electrode is a complete potentiometric cell that contains a silver\/silver chloride (Ag\/AgCl) reference housed within a PEI plastic body with a potassium nitrate electrolyte. The internal elements are isolated from the sample by a compressed silver iodide sensing membrane.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna’s solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFor the Hanna Instruments-4111 to measure iodide accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free iodide ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The Hanna Instruments-4111 iodide solid state ISE can measure from 0.1µM (0.01 mg\/L) to1M (127,000 mg\/L).\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354386772119,"sku":"HI-4111","price":940.41,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-4111_iodine_combination_electrode_2aeb85d0-6cb3-48a0-95e8-ca6abc2cb268.jpg?v=1624279152"},{"product_id":"hanna-instruments-83303k-aquaculture-photometer-kit","title":"Hanna Instruments-83303K Aquaculture Photometer kit","description":"\u003cp\u003e\u003cstrong\u003eHanna Instruments-83303K Aquaculture Photometer Kit\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eKit contains:\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eHI 83303-02 - meter\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93700-01 - ammonia tests x 100\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93732-01 - dissolved oxygen tests x 100\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93710-01 - pH tests x 100\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93728-01 - nitrate tests x 50\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93707-01 - nitrite tests x 50\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 740222N - blue carrying case\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eOne meter can be used for both photometric and pH measurements. The meter has 20 different programmed methods measuring 12 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input. Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMade with the aquaculture industry in mind, the Hanna Instruments-83303 is a comprehensive solution to maintaining optimal chemical and environmental conditions, preventing disease and increasing production.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 measures vital parameters such as Alkalinity, Calcium, Nitrite, and Phosphate. Alkalinity plays a part in a dynamic relationship with pH and CO2 concentrations, high alkalinity water lowers fluctuations in pH. The buffering capacity acts to store extra CO2 essential for photosynthesis in the ponds to produce oxygen. Maintaining calcium at certain levels is vital to proper fish growth and development. Excessive nitrite can be toxic to fish. When nitrite interacts with Haemoglobin, the iron becomes oxidised and the blood cell can no longer carry oxygen. Phosphate is essential to plant growth; too much phosphate in an aquaculture system can contribute to algal blooms decreasing dissolved oxygen vital for a successful ecosystem.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHigh Efficiency LED Light Source\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHigh Quality Narrow Band Interference Filters\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eReference Detector for a Stable Light Source\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eLarge Cuvette Size\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83303 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eFocusing Lens for Greater Light Yield\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354386903191,"sku":"HI-83303K","price":913.24,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83303k_aquaculture_photometer_kit_4005254e-d1f0-4bd5-aba5-9872d22dd173.jpg?v=1624279156"},{"product_id":"hanna-instruments-98308-pure-water-test","title":"Hanna Instruments-98308 Pure Water Test","description":"The Hanna Pure Water Test (PWT) enables you to check the purity of your distilled or demineralised water in laboratory or industrial environments.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-98308 Pure Water Test (PWT) enables users to check the purity of your distilled or demineralised water in laboratory or industrial environments.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis water purity test is suited for fields such as printed circuit board washing, laundry, steam cleaning, checking car battery water and all areas where distilled, demineralised or pure water is used.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-98308 is housed in a durable case that provides excellent protection against harsh industrial environments. \u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eExposed temperature probe for fast response\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGraphite sensors for reduced polarisation\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eReplaceable probes\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e0.1 µS\/cm resolution\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eSupplied with\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCalibration screwdriver\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eInstructions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354387361943,"sku":"HI-98308","price":123.79,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-98308_pure_water_test_935cbf6d-352a-4d18-87ea-0beac3caf8ab.jpg?v=1624279182"},{"product_id":"hanna-instruments-3827-boiler-feedwater-test-kit-for-6-parameters","title":"Hanna Instruments-3827 Boiler feedwater test kit for 6 parameters","description":"\u003cp\u003eThis combination test kit is supplied in a rugged case and contains all that you need to test Alkalinity, Chloride, Hardness, pH, Phosphate and Sulphite.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eBoiler and Feedwater Combination Test Kit\u003c\/h3\u003e\n\u003cp\u003eThe Hanna Instruments-3827 boiler and feedwater chemical test kit measures 6 main parameters; alkalinity, chloride, hardness, pH, phosphate and sulphite\u003c\/p\u003e\n\u003cp\u003eAll the tests are performed with a titration method except for the pH test. pH is obtained with Hanna's pHep®, pH electronic tester which guarantees greater accuracy and a longer life than traditional litmus paper.\u003c\/p\u003e\n\u003cp\u003eThis kit is equipped with all the necessary reagents and equipment to perform over 100 tests (50 for phosphate). All tests are easy to perform with step-by-step instructions and the kit is supplied with a rugged portable carrying case for transportation.\u003c\/p\u003e\n\u003ch3\u003eSignificance of use\u003c\/h3\u003e\n\u003cp\u003eMonitoring the alkalinity, chloride, hardness, phosphate, pH, and sulphite concentrations in boiler and feedwater is essential in preventing hazardous or costly situations.\u003c\/p\u003e\n\u003cp\u003eThese parameters are important in determining the corrosive characteristics of water due to carbonates and chloride.\u003c\/p\u003e\n\u003cp\u003eSulphite is critical to prevent pitting and oxidation of metal components. A high level of sulphite results in a lowered pH, which can also promote corrosion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAlkalinity (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100mg\/L (ppm)\u003cbr\u003e0-300 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1mg\/L (ppm)\u003cbr\u003e3mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein\/bromphenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e110 avg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eChloride (as Cl\u003csup\u003e-\u003c\/sup\u003e)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100mg\/L (ppm)\u003cbr\u003e0-1000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1mg\/L (ppm)\u003cbr\u003e10mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e110 avg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHardness (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0-30.0mg\/L (ppm)\u003cbr\u003e0-300 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3mg\/L (ppm)\u003cbr\u003e3mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eEDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e100 avg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePhosphate (as PO\u003csup\u003e3-\u003c\/sup\u003e\u003csub\u003e4\u003c\/sub\u003e)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eColorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0-5mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAscorbic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e50 avg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003epH\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic pH tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0-14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003epH tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLife of the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSulphite (as Na\u003csub\u003e2\u003c\/sub\u003eSO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 – 20.0 mg\/L (ppm)\u003cbr\u003e0-200 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2mg\/L (ppm)\u003cbr\u003e2 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e110 avg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e440 x 330 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-3827 test kit includes all of the necessary reagents and accessories to perform over 100 tests for every parameter, with the exception of phosphate, which includes reagents for 50 tests, hard carrying cases and instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eReplacement Reagents\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-3811-100 Alkalinity (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003cbr\u003eHI-3815-100 Chloride, 110 tests\u003cbr\u003eHI-3812-100 Hardness, total (as CaCO\u003csub\u003e3\u003c\/sub\u003e) 100 tests\u003cbr\u003eHI-3833-050 Phosphate, 50 tests\u003cbr\u003eHI-3810-100 Dissolved Oxygen, 110 tests\u003cbr\u003eHI-3822-100 Sulphite (as Na\u003csub\u003e2\u003c\/sub\u003eSO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354393718935,"sku":"HI-3827","price":358.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-3827_boiler_feedwater_test_kit_for_6_parameters_d602b166-7cb5-472b-9120-842ae966049b.jpg?v=1624279344"},{"product_id":"hanna-instruments-4110-fluoride-combination-ise-electrode","title":"Hanna Instruments-4110 Fluoride Combination ISE Electrode","description":"\u003cp\u003eThe Hanna Instruments-4110 is a solid state, combination ion selective electrode (ISE) for the determination of fluoride (F-) in solution. The lanthanum fluoride crystal membrane produces a potential change due to the fluoride ion exchange between the membrane and the sample. The internal sensing elements are housed within a durable body, composed of a mixture of polyetherimide (PEI) and epoxy.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4110 is ideal for a variety of applications in drinking water treatment, environmental monitoring, and plating baths.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eSolid state sensor\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSkirted cone geometry\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDetection from 0.02 mg\/L to saturated F-\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4110 is a Fluoride combination ISE ideal for the detection of Free Fluoride in potable water, soft drinks, wine, plants, emulsified food products, plating and pickling acids.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4110 fluoride selective electrode is a complete potentiometric cell that contains a silver\/silver chloride (Ag\/AgCl) reference housed within a PEI\/epoxy body with a potassium nitrate\/potassium chloride electrolyte. The internal elements are isolated from the sample by a lanthanum fluoride crystal membrane.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna’s solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFor the Hanna Instruments-4110 to accurately measure total fluoride concentration, it is important that the pH and ionic strength of the standards and sample be adjusted to a constant value. The total ionic strength adjustment buffer (TISAB) ensures that the solution pH is between pH 5 and 8 and that the activity coefficient is constant. The TISAB solution also preferentially complexes with various metal ions, such as aluminium and iron, which tend to form complexes with fluoride ions. TISAB thus ensures that these metal ions do not interfere, permitting an accurate total fluoride measurement. Measuring all solutions with a constant pH and ionic strength reduces the margin of error between measurements. The Hanna Instruments-4110 fluoride solid state ion selective electrodes can measure from 1µM (0.02 mg\/L) to saturated F-.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eReplaceable Sensing Modules - Combination solid state ion selective electrodes are electrodes that detect free ions in a solution. The lanthanum fluoride crystal sensing membrane is replaceable and easy to attach to the sensor body.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDurable PEI Body - The probe body is composed of a mixture of polyetherimide (PEI) and epoxy.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBNC Connection - The Hanna Instruments-4110 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354396340375,"sku":"HI-4110","price":995.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-4110_fluoride_combination_ise_electrode_4bf12a2f-f651-47a3-938b-8ca7a9bf197e.jpg?v=1624279453"},{"product_id":"bl-983314-0-resistivity-mini-controller-1","title":"BL-983314-0 Resistivity Mini Controller","description":"The BL-983314 is a simple to operate resistivity controller designed for ultra pure water, reverse osmosis, and water conditioning applications. The BL-983314 resistivity controller is also ideal for continuous monitoring to process solutions. Setpoint and calibration are manually adjusted with a trimmer and the alarm relay allows for simple control.\u003cbr\u003e\u003ch3\u003eAbout the BL-983314 Resistivity Mini Controllers\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFire retardant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSelectable overdose protection system\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSplash-resistant cover\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eReadings are automatically temperature compensated with three different coefficients (β=2.4, 3.5 or 4.5 %\/°C). The alarm contact can be used for connection to an alarm, pump, solenoid or dosing system.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe relay contact is open when readings are higher than the setpoint, while for measurements lower than setpoint, the relay contact is closed. The hysteresis is typically 0.20 MΩ •cm from the setpoint.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMeasurements are displayed on the LCD and the multi-coloured LED continuously indicates if the controller is in measurement, dosing, or alarm mode. Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits operators to enable or disable the dosing relay according to need.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe overtime control system advises users when the relay is active for too long, helping to prevent over-dosage.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354397061271,"sku":"BL-983314-0","price":350.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983314-0_resistivity_mini_controller_1_6165b1eb-d17a-47d9-87e4-fb041ae86748.jpg?v=1624279469"},{"product_id":"hanna-instruments-761-total-chlorine-ultra-low-range-handheld-colorimeter-checker®hc","title":"Hanna Instruments-761 Total Chlorine Ultra Low Range  Handheld Colorimeter, Checker HC","description":"\u003cdiv class=\"row\"\u003eThe Hanna Instruments-761 Checker is a simple, accurate, and cost effective way to measure ultra-low ranges of total chlorine.\u003cbr\u003e\n\u003cdiv id=\"description\" class=\"section-row section 1\"\u003e\n\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cp\u003eDesigned as a more accurate alternative to chemical test kits, this checker provides quick, accurate results in four easy steps\u003c\/p\u003e\nThe Hanna Instruments-761 uses an adaptation of the USEPA method 330.5. The reaction between the chlorine and DPD reagent causes a pink tint in the sample.\u003cbr\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\nSmall palm-sized design\u003c\/div\u003e\n\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cp\u003eAccurate from ±5ppb ± 5% of reading\u003c\/p\u003e\nDedicated to a single parameter\u003cbr\u003e\n\u003cp\u003eUses a single AAA battery\u003c\/p\u003e\nAuto Power Off after 10 minutes in inactivity\u003cbr\u003e\n\u003cp\u003eBuilt-in timer for timed reaction readings\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eIdeal for:\u003c\/h3\u003e\nWater Quality\u003cbr\u003e\n\u003cp\u003eEducation\u003c\/p\u003e\nWater Purification\u003cbr\u003e\n\u003cp\u003eEnvironmental\u003c\/p\u003e\n\u003cbr\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003eThe Hanna Instruments-761 Checker is supplied with 2 cuvettes and caps, reagent starter kit (6 packets for total chlorine ultra-low range - re-ordering information Hanna Instruments-761-25 x 25 tests), 1 x 1.5V AAA battery, and an instruction manual.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eAlso available: Calibration set Hanna Instruments-711-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFour steps. One click. Instant Readout\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"section-row section nine\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6 rem-pad-mobile rem-p-l\"\u003e\n\u003cdiv class=\"section-text col-xs-7 col-sm-9\"\u003e\n\u003cp\u003e1. ‘Zero’ the Checker®HC with your vial inside\u003c\/p\u003e\n\u003c\/div\u003e\n2. Place a 10ml water sample into the vial and add your reagent\u003c\/div\u003e\n\u003cbr\u003e3. Place your vial into your Checker®HC\u003cbr\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6 rem-pad-mobile rem-p-r\"\u003e\n\u003cdiv class=\"section-image col-xs-5 col-sm-3 circle-left\"\u003e\u003cbr\u003e\u003c\/div\u003e\n4. Press the button and read the results\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":54897205051765,"sku":"HI-761","price":71.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/total-chlorine-checker-ultra-low-range-0-to-500ppb.jpg?v=1733408724"},{"product_id":"bl-982411-1-orp-controller-range-0-to-1000-mv-1","title":"BL-982411-1 ORP Controller (Range 0 to 1000 mV)","description":"\u003cp\u003eBL 982411 is an ORP mini controller for panel mounting, specially designed for swimming pools and spas. Thanks to its compact size, BL 982411 can be installed in small spaces.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eBL 982411 is an ORP mini controller for panel mounting, specially designed for swimming pools and spas. Thanks to its compact size, BL 982411 can be installed in small spaces. BL 982411 is the ideal solution for those who have always checked ORP manually. Thanks to the automatic dosing, this mini controller will significantly reduce maintenance time.\u003c\/p\u003e\n\u003cp\u003eBL 982411 can be used with any ORP electrode with standard BNC connector. The instrument measures ORP in the 0 to 1000 mV range and shows the readings on the large display.\u003c\/p\u003e\n\u003cp\u003eThe status LED continuously indicates if the controller is in measurement, dosing or alarm mode.\u003c\/p\u003e\n\u003cp\u003eBL 982411 is also provided with a relay for selecting the dosing direction, oxidising or reducing.\u003c\/p\u003e\n\u003cp\u003eYou can also choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits you to enable or disable the dosing relay according to your need.\u003c\/p\u003e\n\u003cp\u003eThe overtime control system advises you when the relay is active for too long, helping to prevent over-dosage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL 982411 is supplied with mounting brackets, transparent cover, and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354400698519,"sku":"BL-982411-1","price":231.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-982411-1_orp_controller_range_0_to_1000_mv_3aa47787-c9aa-4d4c-8381-e228819fb2b0.jpg?v=1624279530"},{"product_id":"hanna-instruments-98713-iso-portable-turbidity-meter-with-fast-tracker-technology","title":"Hanna Instruments-98713 ISO Portable Turbidity meter with Fast Tracker Technology","description":"\u003cp\u003eThe Hanna Instruments-98713 meets and exceeds the requirements of the ISO 7027 for water quality. The instrument is specially designed for water quality measurements, providing a reliable and accurate reading on low turbidity values. Ratio method with 90° and 180° light detector for accurate measurements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-98713-02 meets and exceeds the requirements of the ISO 7027 for water quality and provides reliable and accurate readings on low turbidity values.\u003c\/p\u003e\n\u003cp\u003eAn effective algorithm calculates and converts the detectors output in FNU. Depending on the needed accuracy, normal, continuous, or signal averaging can be selected.\u003c\/p\u003e\n\u003cp\u003eThe optical system consists of an infrared LED and two detectors, that assures long term stability and minimises stray light and colour interferences.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-98713 also compensates for variations in intensity of the LED, minimising the need for frequent calibration.\u003c\/p\u003e\n\u003cp\u003eThis instrument incorporates complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points, time and date can be checked at the touch of a button.\u003c\/p\u003e\n\u003ch3\u003eKey features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo, three or four point calibration\u003c\/li\u003e\n\u003cli\u003eUSB and RS 232 PC connectivity\u003c\/li\u003e\n\u003cli\u003eLog up to 200 records\u003c\/li\u003e\n\u003cli\u003eGLP Features\u003c\/li\u003e\n\u003cli\u003eContinuous current time on display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eExclusive Fast Tracker™\u003c\/h3\u003e\n\u003cp\u003eFor advanced field applications, the Hanna Instruments-98713 is equipped with Fast Tracker™-Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.\u003c\/p\u003e\n\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSample cuvettes and caps\u003c\/li\u003e\n\u003cli\u003eHanna Instruments-98713-11 calibration cuvettes\u003c\/li\u003e\n\u003cli\u003eCuvette cleaning cloth\u003c\/li\u003e\n\u003cli\u003eBatteries and AC adapter\u003c\/li\u003e\n\u003cli\u003eInstructions and rugged carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv id=\"product_tabs\" class=\"product__tabs\"\u003e\n\u003cdiv class=\"headings\"\u003e\u003cstrong\u003e\u003cspan id=\"product_specification_heading\" class=\"cta_specification active\"\u003eSpecification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"tabs\"\u003e\n\u003cdiv class=\"tab specification active\"\u003e\n\u003cdiv class=\"tab__content\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 9.99 FTU\u003cbr\u003e10.0 to 99.9 FTU\u003cbr\u003e100 to 1000 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Selection\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatically\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 FTU from 0.00 to 9.99 FTU\u003cbr\u003e0.1 FTU from 10.0 to 99.9 FTU\u003cbr\u003e1 FTU from 100 to 1000 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% of reading plus 0.1 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatibility\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or 0.01 FTU, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical EMC Deviation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.05 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e860 nm infrared LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of ISO 7027, ratio method with 90° and 180° detector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e60 x 90 mm LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1, 15, 100 and 750 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo, three or four point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e200 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 and USB 1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x 1.5V AA alkaline batteries or AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Shut-off\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 15 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e224 x 87 x 77 mm (8.8 x 3.4 x 3.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e512 g (18 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354406039703,"sku":"HI-98713-02","price":1382.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-98713_iso_portable_turbidity_meter_with_fast_tracker_technology_17a146e8-1a04-44aa-a69e-bcd7517017ac.jpg?v=1624279568"},{"product_id":"bl-983314-1-panel-mounted-resistivity-controller-115-230v-1","title":"BL-983314-1 Panel mounted resistivity controller 115\/230V","description":"\u003cp\u003eThe BL-983314 is a simple to operate resistivity controller designed for ultra pure water, reverse osmosis, and water conditioning applications. The BL-983314 resistivity controller is also ideal for continuous monitoring of process solutions. Setpoint and calibration are manually adjusted with a trimmer and the alarm relay allows for simple control.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFire-retardant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSelectable overdose protection system\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSplash-resistant cover\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eReadings are automatically temperature compensated, with three different coefficients (β=2.4, 3.5 or 4.5 %\/°C). The alarm contact can be used for connection to an alarm, pump, solenoid or dosing system.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe relay contact is open when readings are higher than the setpoint, while for measurements lower than setpoint, the relay contact is closed. The hysteresis is typically 0.20 MΩ•cm from the setpoint.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMeasurements are displayed on the LCD and the multi-coloured LED continuously indicates if the controller is in measurement, dosing, or alarm mode. Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits operators to enable or disable the dosing relay according to need.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe overtime control system advises users when the relay is active for too long, helping to prevent over-dosage.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354418950295,"sku":"BL-983314-1","price":350.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983314-1_panel_mounted_resistivity_controller_115230v_6509caee-4df1-408c-a645-a22340c09ff8.jpg?v=1624279827"},{"product_id":"bl-983322-0-conductivity-controller-low-range-19-99-µs-c","title":"BL-983322-0 Conductivity Controller (Low Range@ 19.99 µS\/c)","description":"\u003cform action=\"https:\/\/www.hannainstruments.co.uk\/checkout\/cart\/add\/uenc\/aHR0cHM6Ly93d3cuaGFubmFpbnN0cnVtZW50cy5jby51ay9jb25kdWN0aXZpdHktY29udHJvbGxlci1sb3ctcmFuZ2VhdC0xOS05OS1zLWNtLmh0bWw,\/product\/1806\/form_key\/5ocYvWr83w8h9Y6w\/\" id=\"product_addtocart_form\" method=\"post\"\u003e\n\u003cdiv class=\"product-view__product-essential__product-shop col-sm-5 col-xs-12 rem-pad-mobile rem-p-r\"\u003e\n\u003cdiv class=\"product-view__product-essential__product-shop__short-description\"\u003e\n\u003cdiv class=\"std\"\u003e\n\u003cp\u003eThe Hanna mini controllers have been specially designed for water conditioning and growing applications. The BL-983322 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream. The device features a large LCD with protective cover.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/form\u003e\n\u003cdiv class=\"product-view__roundels col-xs-12 col-sm-5 rem-p-r\"\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003eWater Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.\u003c\/div\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eMains powered - All mains operated equipment is compatible with UK AC voltage and frequency – 230V, 50Hz.\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\nUsers may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionised) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL-983322 can also be used to monitor the quality of water from DI tanks or from a distillation apparatus. The BL-983322 measures EC from 0.00 to 19.99 μS\/cm.\u003c\/div\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eAdjustable Dry Contact Dosing Relay\u003c\/h3\u003e\n\u003cp\u003eThe BL-983322 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch3\u003eProgrammable Overdose Protection\u003c\/h3\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch3\u003eRelay Control Override\u003c\/h3\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch3\u003eMulticolour LED Indicator\u003c\/h3\u003e\n\u003cp\u003eMulticolour LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFuse Protected Dosing Contacts\u003c\/h3\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch3\u003eLabelled Termination Connections\u003c\/h3\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labelled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003ch3\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h3\u003e\n\u003cp\u003eThe BL-983322 mini controller uses the HI-7634-00 conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003cp\u003e*HI-7634-00 is not included and must be ordered separately.\u003c\/p\u003e\n\u003ch3\u003eOrder Information:\u003c\/h3\u003e\n\u003cp\u003eThe BL 983322 is supplied with mounting brackets, transparent cover, and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354435891351,"sku":"BL-983322-0","price":231.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983322-0_conductivity_controller_low_range_19.99_sc_5b0e14b9-11a3-4168-9f7e-4fc534780897.jpg?v=1624280078"},{"product_id":"hanna-instruments-99300-ec-tds-temperature-meter","title":"Hanna Instruments-99300 EC\/TDS\/Temperature Meter","description":"\u003cdiv class=\"row\"\u003e\n\u003cp\u003eThe HI-99300 is a portable, EC\/TDS\/temperature meter that measures low range conductivity in µS\/cm and TDS in ppm. It is housed in a case rated for IP67 conditions.\u003c\/p\u003e\n\u003cp\u003eThis instrument offers single point, automatic calibration with automatically temperature compensated measurements. The compensation coefficient and EC\/TDS conversion factor are user-selectable from 0.45 to 1.00 and temperature coefficient is selectable from 0.0 to 2.4%\/°C.\u003c\/p\u003e\n\u003cp\u003eThe meter easily fits in the palm of your hand and the bottom probe connection ensures the electrode cable doesn't get in your way. The large, multi-level LCD displays the primary reading, temperature and calibration guides simultaneously. Symbols and messages on the LCD indicate meter status and guides users through operations.\u003c\/p\u003e\n\u003cp\u003eAt start-up, the meter shows the remaining battery percentage and when a low battery condition is detected, a battery symbol appears on the LCD to advise the user that only a few hours of working time is left.\u003c\/p\u003e\n\u003cp\u003eThe HI-76306 EC\/TDS\/temperature probe resists clogging and is easy to clean.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIdeal for\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePure Water\u003c\/li\u003e\n\u003cli\u003eTap Water\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMain benefits\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli\u003eBattery % displayed on start-up\u003c\/li\u003e\n\u003cli\u003eCompact, heavy-duty and water resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eKey features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAmperometric probe technology\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eAutomatic single calibration with calibration indicator\u003c\/li\u003e\n\u003cli\u003eOn-screen tutorial messages for calibration and set-up\u003c\/li\u003e\n\u003cli\u003eReplacement probe - HI-763063\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange - EC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange - TDS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange - Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution - EC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution - TDS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution - Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy - EC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy - TDS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy - Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ ±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eadjustable, from 0.45 to 1.00 with 0.01 increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic, 1 point at 1382 ppm (CONV 0.5)\u003cbr\u003eor at 1500 ppm (CONV 0.7)\u003cbr\u003eor at 1413 µS\/cm (others)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, 0 to 60°C (32 to 140°F) with ß adjustable\u003cbr\u003efrom 0.0 to 2.4% with 0.1% increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI 763063, EC\/TDS\/temperature sensor, with DIN connector,\u003cbr\u003e1 m (3.3') cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x 1.5V AAA \/ approx. 500 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e154 x 63 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e196g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354438906007,"sku":"HI-99300N","price":274.01,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-99300_ectdstemperature_meter_02294a3d-d35d-40e5-a1de-4bc29072074f.jpg?v=1624280137"},{"product_id":"bl-983324-0-tds-mini-controller-range-up-to-49-9-ppm-1","title":"BL-983324-0 TDS Mini Controller (Range up to 49.9 ppm)","description":"\u003cp\u003eBL-983324 is a panel mounted TDS controller, designed for easy installation, configuration and maintenance.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe BL-983324 is a compact, panel mounted, process controller for measuring total dissolved solids (TDS) of a process stream that is within the 0.0 to 49.9 ppm (mg\/L) range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe relay can be used to supply power to a dosing pump or a solenoid connected to a valve. The BL-983324 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e*The BL983324 uses a 0.5 conversion factor in which 1.0 μS\/cm = 0.5 ppm.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eBL-983324-0 TDS Mini Controller (Range up to 49.9 ppm)\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe meter is provided with a dosing relay, activated when the TDS reading exceeds the set point value.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMeasurements are automatically compensated for temperature variations and shown on the large display.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA multi-coloured LED on the front panel continuously indicates if the mini controller is in measurement, dosing or alarm mode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eWiring and external device connections are extremely simple to perform through the terminals on the rear of the instrument.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eChoose an automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations as it allows the dosing relay to be enabled or disabled according to requirements.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe overtime control system advises you when the relay is active too long, helping to prevent over dosage.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eModel is available with power supply input at 230 Vac - 12 Vdc.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information:\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe BL-983324 is supplied with mounting brackets, transparent cover, and instructions.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eAdjustable Dry Contact Dosing Relay\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe BL-983324-0 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eProgrammable Overdose Protection\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eRelay Control Override\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eMulticolour LED Indicator\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eMulticolour LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFuse Protected Dosing Contacts\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLabelled Termination Connections\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eQuick-connect terminal blocks are clearly labelled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe BL-983322 mini controller uses the HI-7634-00 conductivity probe that is available with different cable lengths.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e*HI-7634-00 is not included and must be ordered separately.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354443002007,"sku":"BL-983324-0","price":231.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983324-0_tds_mini_controller_range_up_to_49.9_ppm_1919e69a-073f-48a7-a34c-387ee3328e2d.jpg?v=1624280279"},{"product_id":"hanna-instruments-7874-level-transmitter","title":"Hanna Instruments-7874 Level Transmitter","description":"\u003cp\u003e\u003cspan\u003eThe Hanna Instruments-7874 transmitter has been designed to be combined with the Hanna Instruments-7871 and Hanna Instruments-7873 level controllers. The transmitter is housed in a durable and water resistant ABS body, and allows the user to easily adjust the length of the sensor bars according to the specific need.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eLevel Transmitter\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAccurate level control is critical to many industrial applications, especially for process adjustments using aggressive chemicals. Our sensor bars are built with stainless steel for long life even in harsh conditions. They are easy to install and ideal for monitoring tanks and water conditioning plants.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-7874 transmitter has been designed to be combined with the Hanna Instruments-7871 and Hanna Instruments-7873 level controllers. The transmitter is housed in a durable and water resistant ABS body, and allows the user to easily adjust the length of the sensor bars according to the specific need.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-7874 is supplied with a sturdy mounting bracket for quick and easy installation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003ePlease note: Hanna Instruments-731324 measuring bar set is sold separately.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354447786135,"sku":"HI-7874","price":157.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-7874_level_transmitter_57495ccb-1114-4b8f-abbe-df76b03ea609.jpg?v=1624280331"},{"product_id":"hanna-instruments-701-free-chlorine-handheld-colorimeter-checker®hc","title":"Hanna Instruments-701 Free Chlorine Handheld Colorimeter - Checker®HC","description":"\u003cp\u003eIdeal for swimming pools, spas and aquariums.\u003c\/p\u003e\n\u003cp\u003eChlorine is the most common water disinfectant and by monitoring chlorine regularly and accurately, serious health and safety risks can be avoided.\u003c\/p\u003e\n\u003cp\u003eCan also be used to determine chlorine levels in fish tanks for optimum fish and plant health. Use alongside recommended dechlorinators.\u003c\/p\u003e\n\u003cp\u003eChecker®HC is supplied with reagents for 6 tests. Use code Hanna Instruments-701-25 (25 tests) for future purchases.\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003ch3\u003eIdeal for swimming pools, spas and aquariums\u003c\/h3\u003e\n\u003cp\u003eChlorine is the most common water disinfectant and by monitoring chlorine regularly and accurately, serious health and safety risks can be avoided.\u003c\/p\u003e\n\u003cp\u003eThe contoured style of the Hanna Instruments-701 Free Chlorine Checker is designed to fit in the palm of your hand. The large LCD is easy to read and the auto shut-off feature ensures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003eCan also be used to determine chlorine levels in fish tanks for optimum fish and plant health. Use alongside recommended dechlorinators.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"section-row section four\"\u003e\n\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003ch3\u003eIdeal for\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eSwimming pools and spas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eFruit, vegetable and salad washing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eDisinfection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAquaculture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMain Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eTesting is quick and easy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eHigh precision results - more accurate than chemical test kits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAuto shut-off feature means the Checker cannot be left on by mistake\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eFully portable, fitting easily into both palm and pocket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e2 sample cuvettes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCuvette cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eStarter pack of reagents (re-ordering information - Hanna Instruments-701-25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1.5 AAA battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFour steps, one click instant readout\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eZero the Checker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAdd reagent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eInsert sample into Checker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003ePress button for results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecision\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3% of reading ±0.03 ppm (mg\/L) @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 2 minutes of non-use and after read\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of USEPA method 330.5. The reaction between free chlorine and the DPD reagent will cause a pint tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePLEASE NOTE:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eIn some cases, samples may contain other parameters which may interfere with results\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference may be caused by:\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBromine, Iodine, Ozone, Oxidized forms of Chromium and Manganese. In case of water with hardness greater than 500 mg\/L CaCO\u003csub\u003e3\u003c\/sub\u003e, shake the sample for approximately 2 minutes after adding the powder reagent.\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eIf the water used for this procedure has an alkalinity value greater than 250 mg\/L CaCO\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eor acidity value greater than 150 mg\/L CaCO\u003csub\u003e3\u003c\/sub\u003e, the colour of the sample may develop only partially, or may rapidly fade. To resolve this, neutralise the sample with diluted HCl or NaOH.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354486091927,"sku":"HI-701","price":71.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi701_300caf6c-822a-477d-baf5-ad9ce80349fc.jpg?v=1624280638"},{"product_id":"hanna-instruments-721-high-range-iron-handheld-colorimeter-checker®hc","title":"Hanna Instruments-721 High Range Iron Handheld Colorimeter - Checker®HC","description":"\u003cp\u003eThe Hanna Instruments-721 pocket checker for iron gives quick, accurate results at the price of a chemical test kit.\u003c\/p\u003e\n\u003cp\u003eChecker®HC is supplied with reagents for 6 tests. Use code Hanna Instruments-721-25 (25 tests) for future purchases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwimming pools and spas\u003c\/li\u003e\n\u003cli\u003eAquaculture\u003c\/li\u003e\n\u003cli\u003eQuality control and ground water monitoring\u003c\/li\u003e\n\u003cli\u003eAgriculture and small holdings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cstrong\u003eHanna Instruments-721 High Range Iron Handheld Colorimeter - Checker®HC\u003c\/strong\u003e\n\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\n\u003cp\u003eAbout 6.3% of the earth crust is made of iron with 43% of this amount held in the soil. As a result, iron is naturally present in most water supplies.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eLeft in the water, iron will not only stain pipework and swimming pool surfaces, or poison aquatic life, it will also affect the water taste and cause problems with animal feed lines.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eTesting should therefore form an important part of any water monitoring process - particularly if you are checking your pool, watching the quality of water in your fish tank or needing to monitor water run-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cstrong\u003eKey features\u003c\/strong\u003e\n\u003cdiv class=\"section-row section four\"\u003e\n\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate and easy to use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003ePhenanthroline method\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eAccuracy ±0.04 mg\/L (ppm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e0.01 mg\/L (ppm) resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to work with Hanna reagents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eLarge easy to read digits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eAuto shut-off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eFits into the palm of your hand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e2 sample cuvettes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e1 black cuvette cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eStarter pack of 6 reagents for Iron (re-ordering information Hanna Instruments-721-25 x 25 tests)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1.5V AAA battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354486485143,"sku":"HI-721","price":71.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi721_1a2c8da1-b02b-4597-b66c-cecca14216bb.jpg?v=1624280667"},{"product_id":"hanna-instruments-711-total-chlorine-handheld-colorimeter-checker®hc","title":"Hanna Instruments-711 Total Chlorine Handheld Colorimeter - Checker®HC","description":"\u003cp\u003eIdeal for swimming pools, spas and aquariums.\u003c\/p\u003e\n\u003cp\u003eChlorine is the most common water disinfectant. Once in water, it presents as free chlorine and total chlorine.\u003c\/p\u003e\n\u003cp\u003eChecker®HC is supplied with reagents for 6 tests. Use code Hanna Instruments-711-25 (25 tests) for future purchases.\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv id=\"description\" class=\"section-row section 1\"\u003e\n\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003ch3\u003eIdeal for swimming pools, spas and aquariums\u003c\/h3\u003e\n\u003cp\u003eChlorine is the most common water disinfectant. Once in water, it presents as free chlorine and total chlorine.\u003c\/p\u003e\n\u003cp\u003eFree chlorine is the chlorine that is available in the water to tackle bacteria. As the process of disinfection takes place, the levels of free chlorine will reduce. Total chlorine is the measurement of free and used chlorine in the water.\u003c\/p\u003e\n\u003cp\u003eIf the total chlorine is high but the free chlorine is low or non-existent, then there is insufficient chlorine in the water to deal with the levels of contamination.\u003c\/p\u003e\n\u003cp\u003eFree chlorine is the most frequently tested of the two chemicals. By checking for the two as part of a rigorous testing procedure, adjustments in chlorine levels can be made quickly and easily and a high level of disinfection can be easily maintained.\u003c\/p\u003e\n\u003cp\u003eCan also be used to determine chlorine levels in fish tanks for optimum fish and plant health. Use alongside recommended dechlorinators.\u003c\/p\u003e\n\u003ch3\u003eIdeal for\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eSwimming pools and spas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eWater and quality control checks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eDisinfection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eWaste water treatment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAquaculture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"section-row section four\"\u003e\n\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003ch3\u003eMain Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eTesting is quick and easy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eHigh precision results - more accurate than chemical test kits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAuto shut-off feature means the Checker cannot be left on by mistake\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eFully portable, fitting easily into both palm and pocket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e2 sample cuvettes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCuvette cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eStarter pack of reagents x 6 (re-ordering information: Hanna Instruments-711-25 x 25 tests)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1.5 AAA battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso available: Calibration set Hanna Instruments-711-11\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"HI-711","offer_id":56408857051509,"sku":"HI-711","price":71.35,"currency_code":"GBP","in_stock":true},{"title":"HI-711-EXPIRED 09\/25","offer_id":56408857084277,"sku":"HI-712-EXPIRED","price":30.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/1_87a1c325-1af2-45ad-9481-2cb1b4a23bbe.jpg?v=1730902827"},{"product_id":"hanna-insturments-hi-762-ultra-low-range-free-chlorine-handheld-colorimeter-checker®hc","title":"Hanna Insturments HI-762 Ultra Low Range Free Chlorine Handheld Colorimeter, Checker®HC(with 25 tests)","description":"\u003ch1\u003eHanna Insturments HI-762 Ultra Low Range Free Chlorine Handheld Colorimeter, Checker®HC\u003c\/h1\u003e\n\u003cp\u003eChlorine is the most common water disinfectant and by monitoring chlorine regularly and accurately, serious health and safety risks can be avoided.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Free Chlorine Ultra Low Range Checker® bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits have limited accuracy and resolution since they rely upon the human eye to discern differences in color\u003c\/p\u003e\n\u003cp\u003eProfessional instrumentation incorporates a light source such as an LED or tungsten lamp with a filter and a light sensing detector to precisely determine ion concentration. Professional instrumentation offers greater resolution and accuracy but can cost hundreds of dollars. The Hanna Free Chlorine Ultra Low Range Checker® uses a fixed wavelength LED and silicon photo detector to provide the accuracy of professional instrumentation at the affordable price of a chemical test kit.\u003c\/p\u003e\n\u003cp\u003eThe contoured style of the HI-762 ultra-low range Free Chlorine Checker is designed to fit in the palm of your hand. The large LCD is easy to read and the auto shut-off feature ensures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eIdeal for\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwimming pools and spas\u003c\/li\u003e\n\u003cli\u003eFruit, vegetable and salad washing\u003c\/li\u003e\n\u003cli\u003eDisinfection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eMain Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTesting is quick and easy\u003c\/li\u003e\n\u003cli\u003eHigh precision results - more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eAuto shut-off feature means the Checker cannot be left on by mistake\u003c\/li\u003e\n\u003cli\u003eFully portable, fitting easily into both palm and pocket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 sample cuvettes\u003c\/li\u003e\n\u003cli\u003eCuvette cap\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePack of Reagents x 25 tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e1 x 1.5 AAA battery\u003c\/li\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRange 0 to 500 ppb\u003c\/p\u003e\n\u003cp\u003eResolution 1 ppb\u003c\/p\u003e\n\u003cp\u003eAccuracy @ 25°C ±4% of reading ±20ppb\u003c\/p\u003e\n\u003cp\u003eLight Source LED @ 525 nm\u003c\/p\u003e\n\u003cp\u003eLight Detector Silicon photocell\u003c\/p\u003e\n\u003cp\u003eEnvironment 0 to 50°C; RH max 95% non-condensing\u003c\/p\u003e\n\u003cp\u003eBattery Type (1) 1.5V AAA\u003c\/p\u003e\n\u003cp\u003eAuto-off After 10 minutes of non-use\u003c\/p\u003e\n\u003cp\u003eDimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5\")\u003c\/p\u003e\n\u003cp\u003eWeight 64 g\u003c\/p\u003e\n\u003cp\u003eMethod adaptation of USEPA method 330.5, DPD method\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSku: HI-762\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"HI-762","offer_id":56409686278517,"sku":"HI-762","price":85.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-762-ultra-low-range-free-chlorine-checker-0-to-500ppb.jpg?v=1732285610"},{"product_id":"hanna-instruments-hi-713-phosphate-low-range-handheld-colorimeter-checker-hc","title":"Hanna Instruments HI-713 Phosphate Low Range Handheld Colorimeter - Checker HC","description":"\u003cp\u003eThe Hanna Instruments Phosphate Low Rnage Handheld Colorimeter Checker, is a compact and reliable tool designed for accurate measurement of phosphate levels in water. Ideal for water systems uch as aquaculture, wastewater treatment and freshwater systems, this colorimeter ensures precise testing to help maintain water quality. \u003c\/p\u003e\n\u003cp\u003eIts user friendly design allows you to easily analyse samples with just a few simple steps. \u003c\/p\u003e\n\u003cp\u003eLightweight and portable, this handheld colorimeter is perfect for fieldwork and laboratory use, making it an essential tool for professionals and enhusiasts alike. \u003c\/p\u003e\n\u003cp\u003eChecker range: 0.00 to 2.50 ppm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for coral reef tanks and fresh and salt water aquariums\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhosphate directly inhibits calcification by corals and coralline algae - even at low levels. The health of plants in freshwater aquaria will also be impaired by raised levels of phosphate in the water. Phosphate naturally occurs as waste decomposes in coral reef, salt and fresh water aquariums. While it does not directly harm fish when levels are high, resulting green algae growth can deplete the oxygen levels in water. Corals can lose their colour due to the effects of brown algae.\u003c\/p\u003e\n\u003cp\u003eThe optimum phosphate level - particularly for reef tanks - is often quoted as zero or 0.05 mg\/L (ppm)\u003c\/p\u003e\n\u003cp\u003eWith its ability to register the presence of phosphate in salt and fresh water at extremely low levels, the new Hanna Phosphate Checker offers a real 'must-have' addition to the fish lover's equipment chest.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTesting is quick and easy\u003c\/p\u003e\n\u003cp\u003eHigh precision results - more accurate than chemical test kits\u003c\/p\u003e\n\u003cp\u003eAuto shut-off feature means the Checker cannot be left on by mistake\u003c\/p\u003e\n\u003cp\u003eFully portable, fitting easily into both palm and pocket\u003c\/p\u003e\n\u003cp\u003eFits nicely into your palm or pocket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2 sample cuvettes\u003c\/p\u003e\n\u003cp\u003eCuvette cap\u003c\/p\u003e\n\u003cp\u003eStarter pack of reagents x 6 (re-ordering information HI-713-25 x 25 tests)\u003c\/p\u003e\n\u003cp\u003e1 x 1.5 AAA battery\u003c\/p\u003e\n\u003cp\u003eInstructions\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/testallwater.co.uk\/collections\/hanna-reagents\/products\/hanna-instruments-713-25-reagents-for-hanna-instruments-713-phosphate-pocket-checker-x-25-tests\" target=\"_blank\"\u003eReplacement Reagents For HI-713\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eSku: HI-713\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":41124241014935,"sku":"HI-713","price":71.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/3_2c87e937-ccf3-4e8b-b95d-f49d513e0c74.jpg?v=1733304963"},{"product_id":"hanna-instruments-hi-97711-free-and-total-chlorine-portable-photometer","title":"Hanna Instruments HI-97711 FREE AND TOTAL CHLORINE PORTABLE PHOTOMETER","description":"\u003cp\u003eThis meter offers a superior optical system that utilises a reference detector and narrow band interference filters for extremely fast and repeatable measurements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFree and total chlorine in water up to 5.00 mg\/L (ppm)\u003c\/li\u003e\n\u003cli\u003eNo warm up time before taking a measurement\u003c\/li\u003e\n\u003cli\u003eTutorial mode for step-by-step instructions\u003c\/li\u003e\n\u003cli\u003eUses either powder or cost saving liquid reagents\u003c\/li\u003e\n\u003cli\u003eCAL Check\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HI-97711 has an innovative optical system that offers superior performance in accuracy, repeatability, and the short amount of time it takes to perform a measurement.\u003c\/p\u003e\n\u003cp\u003eThis compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement.\u003c\/p\u003e\n\u003cp\u003eThe use of a backlit dot matrix LED allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different methods, reviewing GLP data, recalling the last 50 measurements, and customising the meter to user preferences.\u003c\/p\u003e\n\u003cp\u003eHI-97711 is waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a protected battery compartment that holds three AA batteries.\u003c\/p\u003e\n\u003cp\u003eThe compact design fits comfortably in the hand for use in the field or on a table for benchtop use. The LCD is 71 mm (2.75\") by 37 mm (1.6\") and is backlit for easy viewing under all conditions.\u003c\/p\u003e\n\u003ch3\u003eStable Light Source:\u003c\/h3\u003e\n\u003cp\u003eThe internal reference system of the HI-97711 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eHigh Efficiency Light Source:\u003c\/h3\u003e\n\u003cp\u003eLED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Filters:\u003c\/h3\u003e\n\u003cp\u003eImproved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eGreater Light Yield:\u003c\/h3\u003e\n\u003cp\u003eA focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.\u003c\/p\u003e\n\u003ch3\u003eCAL Check Functionality:\u003c\/h3\u003e\n\u003cp\u003eHanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.\u003c\/p\u003e\n\u003ch3\u003eMultiple Measurement Methods:\u003c\/h3\u003e\n\u003cp\u003eUsers can select the use of powder reagents supplied in packets or the use of low cost liquid reagents supplied in a dropper bottle.\u003c\/p\u003e\n\u003ch3\u003eBuilt-in Reaction Timer:\u003c\/h3\u003e\n\u003cp\u003eWaiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size:\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the HI-97711 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch3\u003eIntuitive Dot Matrix Display:\u003c\/h3\u003e\n\u003cp\u003eDesigned with a backlit graphic LCD, plus virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.\u003c\/p\u003e\n\u003ch3\u003eAuto-off Protection:\u003c\/h3\u003e\n\u003cp\u003eThe meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/p\u003e\n\u003ch3\u003eAbout Chlorine\u003c\/h3\u003e\n\u003cp\u003eChlorine is a common chemical used by many due to is disinfection, oxidation and bleaching properties.\u003c\/p\u003e\n\u003cp\u003eIn swimming pools, drinking water and food processing, chlorine is used to disinfect and keep bacteria from growing. In metal finishing, it is used as an oxidiser to convert cyanide in wastewater to cyanate.\u003c\/p\u003e\n\u003cp\u003eIn the pulp and paper industry, it is used to bleach wood pulp so that paper is white. The HI-97711 is designed to measure low levels of free and total chlorine in water up to 5.00 mg\/L (ppm).\u003c\/p\u003e\n\u003ch3\u003eAdvanced optical system\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLED that generates very little heat.\u003c\/li\u003e\n\u003cli\u003e8 nm narrowband interference filter that is accurate to +\/- 1 nm and offers 25% increase in light efficiency.\u003c\/li\u003e\n\u003cli\u003eReference detector that modulates the voltage to LED for consistent light output.\u003c\/li\u003e\n\u003cli\u003eA concave focusing lens that reduces errors from imperfections in the cuvette.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAlso available as a kit: HI-97711C Free \u0026amp; Total Chlorine Portable Photometer Kit\u003c\/h3\u003e\n\u003cp\u003eThe HI-97711C kit is supplied with a meter, CAL Check standards, cuvettes (2), caps (2), plastic inserts for cuvettes (2), scissors, a cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and an instrument quality certificate.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Photometer Only","offer_id":43702839738626,"sku":"HI-97711","price":502.46,"currency_code":"GBP","in_stock":true},{"title":"Photometer Plus Case","offer_id":43702839771394,"sku":"HI-97711C","price":736.54,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-97711-free-and-total-chlorine-portable-photometer.jpg?v=1680197791"},{"product_id":"hanna-instruments-hi-718-iodine-handheld-colorimeter-checker","title":"Hanna Instruments HI-718 Iodine Handheld Colorimeter Checker","description":"\u003cp\u003eQuicker and easier to use than chemical test kits, the new HI-718 Iodine Checker from Hanna will give you accurate results in an instant.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFreshwater Aquaculture\u003c\/p\u003e\n\u003cp\u003eFruit and vegetable sanitation\u003c\/p\u003e\n\u003cp\u003eIndustrial processes and disinfection\u003c\/p\u003e\n\u003cp\u003eDrinking water and quality control checks\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note: the HI-718 Iodine Checker cannot be used for swimming pool or spa water testing due to chlorine interference.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccurate and easy to use\u003c\/p\u003e\n\u003cp\u003eAccuracy ±0.1 mg\/L (ppm)\u003c\/p\u003e\n\u003cp\u003e0.01 mg\/L (ppm) resolution\u003c\/p\u003e\n\u003cp\u003eDesigned to work with Hanna reagents\u003c\/p\u003e\n\u003cp\u003eLarge easy to read digits\u003c\/p\u003e\n\u003cp\u003eAuto shut-off\u003c\/p\u003e\n\u003cp\u003eFits into the palm of your hand and pocket\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2 sample cuvettes\u003c\/p\u003e\n\u003cp\u003e1 black cuvette cap\u003c\/p\u003e\n\u003cp\u003eStarter pack of 6 reagents for Iodine (re-ordering information HI-718-25 x 25 tests\u003c\/p\u003e\n\u003cp\u003e1 x 1.5V AAA battery\u003c\/p\u003e\n\u003cp\u003eInstructions\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eAlso available: HI-718-11 Calibration Set.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eSku:HI-718\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"HI-718","offer_id":56418715697525,"sku":"HI-718","price":71.35,"currency_code":"GBP","in_stock":true},{"title":"HI-718-NO REAGENTS","offer_id":56418715730293,"sku":"HI-718-NO REAGENTS","price":39.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/118681_2b83c95b-9b0f-4673-a54f-004a2e528f6d0.jpg?v=1693392117"},{"product_id":"hanna-instruments-hi-747-copper-low-range-colorimeter-checker","title":"Hanna Instruments HI-747 Copper Low Range Colorimeter Checker","description":"\u003cp\u003eThe HI-747 Copper low range Checker is a simple, accurate and cost effective way to measure low ranges of copper in water.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned as a more accurate alternative to chemical test kits, the HI-747 provides quick, accurate results in four easy steps.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eHI-747 uses an adaptation of the EPA method. The reaction between copper and the bicinchoninate reagent causes a purple tint in the sample.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWater quality\u003c\/p\u003e\n\u003cp\u003eEducation\u003c\/p\u003e\n\u003cp\u003ePlating\u003c\/p\u003e\n\u003cp\u003eWastewater\u003c\/p\u003e\n\u003cp\u003eEnvironmental\u003c\/p\u003e\n\u003cp\u003eFreshwater Aquariums\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSmall palm-sized design\u003c\/p\u003e\n\u003cp\u003eAccurate from ±10 ppb ±5% of reading\u003c\/p\u003e\n\u003cp\u003eDedicated to a single parameter\u003c\/p\u003e\n\u003cp\u003eAuto power off after 10 minutes of inactivity\u003c\/p\u003e\n\u003cp\u003eBuilt-in timer for timed reaction readings\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied With\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003esample cuvettes and caps (2),\u003c\/p\u003e\n\u003cp\u003eCopper LR reagent starter kit for 6 tests (re-ordering information HI-747-25 x 25 tests),\u003c\/p\u003e\n\u003cp\u003ebattery,\u003c\/p\u003e\n\u003cp\u003einstructions\u003c\/p\u003e\n\u003cp\u003equick start guide.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eSku: HI-747\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":43701948547330,"sku":"HI-747","price":80.28,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/1_49fc8170-847e-4a64-b954-78266767b09a.png?v=1779119640"},{"product_id":"hanna-instruments-hi-723-chromium-vi-hight-range-checker-hc","title":"Hanna Instruments HI-723 Chromium VI High Range Checker HC","description":"\u003cp\u003eBy monitoring Chromium VI with the Hanna HI-723 High Range Chromium VI Checker serious human health and safety risks can be avoided..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccurate and easy to use\u003c\/p\u003e\n\u003cp\u003eDiphenylcarbohydrazide method\u003c\/p\u003e\n\u003cp\u003eAccuracy ±5 ppb ±4% of reading\u003c\/p\u003e\n\u003cp\u003e1 ppb (µg\/L) resolution\u003c\/p\u003e\n\u003cp\u003eDesigned to work with Hanna reagents\u003c\/p\u003e\n\u003cp\u003eLarge easy to read digits\u003c\/p\u003e\n\u003cp\u003eAuto shut-off\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFruit and vegetable sanitation\u003c\/p\u003e\n\u003cp\u003eDrinking water and quality control checks\u003c\/p\u003e\n\u003cp\u003eElectroplating industries\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2 sample cuvettes\u003c\/p\u003e\n\u003cp\u003e1 black cuvette cap\u003c\/p\u003e\n\u003cp\u003eStarter pack of 6 reagents for Iodine (re-ordering information HI-723-25 x 25 tests)\u003c\/p\u003e\n\u003cp\u003ePowder reagents for chromium VI HR (6)\u003c\/p\u003e\n\u003cp\u003e1 x 1.5V AAA battery\u003c\/p\u003e\n\u003cp\u003eInstructions\u003c\/p\u003e\n\u003cp\u003eSku: HI-723\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":43706500907266,"sku":"HI-723","price":82.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/1_45ce9a92-5d1b-4a5a-b3dc-6962eaddffb7.jpg?v=1728984740"},{"product_id":"hanna-instruments-hi-729-fluoride-low-range-checker","title":"Hanna Instruments HI-729 Fluoride Low Range Checker","description":"\u003cp\u003eFluoride is one of the few chemicals that have been shown to cause significant effects in people through drinking water. Fluoride has beneficial effects on teeth at low concentrations in drinking water, but excessive exposure to fluoride in drinking water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.\u003c\/p\u003e\n\u003cp\u003eThe HI-729 pocket checker is a simple and accurate way to measure low ranges of fluoride.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRange: 0.00 -2.00 ppm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResolution: 0.01ppm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy: 0.10ppm +\/- 5% of reading @25c\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery: 1.5V AAA alkaline\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccurate and easy to use\u003c\/p\u003e\n\u003cp\u003eAdaptation of SPADNS method\u003c\/p\u003e\n\u003cp\u003e±0.05 ppm ±5% of reading\u003c\/p\u003e\n\u003cp\u003e0.01 ppm resolution\u003c\/p\u003e\n\u003cp\u003eDesigned to work with Hanna reagents\u003c\/p\u003e\n\u003cp\u003eLarge easy to read digits\u003c\/p\u003e\n\u003cp\u003eAuto shut-off\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWater testing\u003c\/p\u003e\n\u003cp\u003eQuick on the spot analysis\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2 sample cuvettes with caps\u003c\/p\u003e\n\u003cp\u003eReagents for 6 tests (re-ordering information HI-729-26 x 20 tests\u003c\/p\u003e\n\u003cp\u003eSyringe with tip\u003c\/p\u003e\n\u003cp\u003e1 x 1.5V AAA battery\u003c\/p\u003e\n\u003cp\u003eInstructions\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSku:HI-729\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":43713509392642,"sku":"HI-729","price":85.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/118724_4e2c8536-d78b-4799-bf74-099d8ca5045f0.jpg?v=1702562586"},{"product_id":"hanna-instruments-hi-97710c-ph-free-total-chlorine-portable-photometer-kit","title":"Hanna Instruments HI-97710C pH, Free \u0026 Total Chlorine Portable Photometer Kit","description":"\u003cdiv id=\"product-description-short\" class=\"product__description_short\" itemprop=\"description\"\u003e\n\u003cp\u003eThe HI-97710C kit is supplied with a meter, CAL Check standards, cuvettes (2), caps (2), plastic inserts for cuvettes (2), scissors, a cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and an instrument quality certificate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-features product__features\"\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003epH\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eChlorine\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003ch3\u003eAbout the HI-97710 Photometer\u003c\/h3\u003e\n\u003cp\u003eHI-97710 is an advanced portable photometer for the measurement of pH, free chlorine, and total chlorine in water. This meter offers a superior optical system that utilises a reference detector and narrow band interference filters for extremely fast and repeatable measurements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo warm up time before taking a measurement\u003c\/li\u003e\n\u003cli\u003eTutorial mode for step-by-step instructions\u003c\/li\u003e\n\u003cli\u003eUses either powder or cost saving liquid reagents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe HI-97710 has an innovative optical system that offers superior performance in accuracy, repeatability, and the short amount of time it takes to perform a measurement. This compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement. The use of a backlit dot matrix LED allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different methods, reviewing GLP data, recalling the last 50 measurements, and customising the meter to user preferences.\u003c\/p\u003e\n\u003cp\u003eHI-97710 is waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a protected battery compartment that holds three AA batteries. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use. The LCD is 71 mm (2.75\") by 37 mm (1.6\") and is backlit for easy viewing under all conditions.\u003c\/p\u003e\n\u003ch3\u003eStable Light Source:\u003c\/h3\u003e\n\u003cp\u003eThe internal reference system of the HI-97710 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eHigh Efficiency Light Source:\u003c\/h3\u003e\n\u003cp\u003eLED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eHigh Quality Filters:\u003c\/h3\u003e\n\u003cp\u003eImproved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eGreater Light Yield:\u003c\/h3\u003e\n\u003cp\u003eA focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eCAL Check Functionality:\u003c\/h3\u003e\n\u003cp\u003eHanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eMultiple Measurement Methods:\u003c\/h3\u003e\n\u003cp\u003eUsers can select the use of powder reagents supplied in packets or the use of low cost liquid reagents supplied in a dropper bottle.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eBuilt-in Reaction Timer:\u003c\/h3\u003e\n\u003cp\u003eWaiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size:\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the HI-97710 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eIntuitive Dot Matrix Display:\u003c\/h3\u003e\n\u003cp\u003eThe HI-97710 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eAuto-off Protection:\u003c\/h3\u003e\n\u003cp\u003eThe meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eAbout Chlorine\u003c\/h3\u003e\n\u003cp\u003eChlorine is a common chemical used by many due to is disinfection properties.\u003c\/p\u003e\n\u003cp\u003eFree chlorine can exist in two forms and which form is present is based on the pH. At pH less than 7.6, the predominate form is hypochlorous acid (HOCl), while at pH greater than 7.6, the hypochlorite (OCl-) form becomes predominate.\u003c\/p\u003e\n\u003cp\u003eThis is very important when it comes to preventing biological growth in water or keeping a swimming pool safe since hypochlorous acid is 100 times more effective as a sanitiser.\u003c\/p\u003e\n\u003cp\u003eTotal chlorine represents both the free chlorine and combined chlorine present.\u003c\/p\u003e\n\u003cp\u003eCombined chlorine is the chlorine bound to nitrogen substances such as ammonia. In swimming pools, combined chlorine is what we can smell and is irritating to the eyes. The free chlorine measurement is subtracted from the total chlorine measurement in order to know how much combined chlorine is present. HI-97710 is designed to measure pH and low levels of free and total chlorine in water up to 5.00 mg\/L (ppm).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eAdvanced optical system\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLED that generates very little heat.\u003c\/li\u003e\n\u003cli\u003e8 nm narrowband interference filter that is accurate to +\/- 1 nm and offers 25% increase in light efficiency.\u003c\/li\u003e\n\u003cli\u003eReference detector that modulates the voltage to LED for consistent light output.\u003c\/li\u003e\n\u003cli\u003eA concave focusing lens that reduces errors from imperfections in the cuvette.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 to 8.5 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eadaptation of Phenol Red method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eadaptation of the EPA 330.5 DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003esilicon photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eround, 24.6 mm diameter (22 mm inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003edate, time of last calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel B\/W LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e50 measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA battery (3 pcs.) \/ \u0026gt; 800 measurements (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 15 minutes of inactivity (30 minutes before a READ measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); relative humidity: 100% (IP 67, floating case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g (13.4 oz.) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eKit: HI-97710C is supplied with a meter, CAL-Check standards, cuvettes (2), caps (2), plastic inserts for cuvettes (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":56336721510773,"sku":null,"price":707.15,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-97710c-ph-free-total-chlorine-portable-photometer-kit.jpg?v=1763076305"},{"product_id":"hanna-instruments-hi-97718-iodine-photometer-range-0-0-to-12-5-mg-l-ppm","title":"Hanna Instruments HI-97718 Iodine photometer: range 0.0 to 12.5 mg\/L (ppm)","description":"\u003cp\u003eThis meter offers a superior optical system that utilises a reference detector and narrow band interference filters for extremely fast and repeatable measurements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo warm up time before taking a measurement\u003c\/li\u003e\n\u003cli\u003eTutorial mode for step-by-step instructions\u003c\/li\u003e\n\u003cli\u003eUses either powder or cost saving liquid reagents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach photometer is delivered in a cardboard box and is supplied with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSample cuvette (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eSample cuvette cap (2 pcs.)\u003c\/li\u003e\n\u003cli\u003ePlastic stopper (2 pcs.)\u003c\/li\u003e\n\u003cli\u003e1.5V AA Alkaline batteries\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate\u003c\/li\u003e\n\u003cli\u003eInstruction manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe photometer has an innovative optical system that offers superior performance in accuracy, repeatability and the short amount of time it takes to perform a measurement. This compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement. The use of a backlit dot matrix LED allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different methods, reviewing GLP data, recalling the last 50 measurements, and customising the meter to user preferences.\u003c\/p\u003e\n\u003cp\u003eThe photometer is waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a protected battery compartment that holds three AA batteries. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use. The LCD is 71 mm (2.75\") by 37 mm (1.6\") and is backlit for easy viewing under all conditions.\u003c\/p\u003e\n\u003ch3\u003eAdvanced optical system\u003c\/h3\u003e\n\u003cp\u003eLED that generates very little heat.\u003c\/p\u003e\n\u003cp\u003e8 nm narrowband interference filter that is accurate to +\/- 1 nm and offers 25% increase in light efficiency.\u003c\/p\u003e\n\u003cp\u003eReference detector that modulates the voltage to LED for consistent light output.\u003c\/p\u003e\n\u003cp\u003eA concave focusing lens that reduces errors from imperfections in the cuvette.\u003c\/p\u003e\n\u003ch3\u003eStable Light Source:\u003c\/h3\u003e\n\u003cp\u003eThe internal reference system of the photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eHigh Efficiency Light Source:\u003c\/h3\u003e\n\u003cp\u003eLED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Filters:\u003c\/h3\u003e\n\u003cp\u003eImproved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eGreater Light Yield:\u003c\/h3\u003e\n\u003cp\u003eA focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.\u003c\/p\u003e\n\u003ch3\u003eCAL Check Functionality:\u003c\/h3\u003e\n\u003cp\u003eHanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.\u003c\/p\u003e\n\u003ch3\u003eMultiple Measurement Methods:\u003c\/h3\u003e\n\u003cp\u003eUsers can select the use of powder reagents supplied in packets or the use of low cost liquid reagents supplied in a dropper bottle.\u003c\/p\u003e\n\u003ch3\u003eBuilt-in Reaction Timer:\u003c\/h3\u003e\n\u003cp\u003eWaiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size:\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the photometer fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch3\u003eIntuitive Dot Matrix Display:\u003c\/h3\u003e\n\u003cp\u003eThe photometer is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.\u003c\/p\u003e\n\u003ch3\u003eAuto-off Protection:\u003c\/h3\u003e\n\u003cp\u003eThe meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/p\u003e\n\u003ch3\u003eAbout Iodine\u003c\/h3\u003e\n\u003cp\u003eDisinfectant properties of iodine has led to its use as an alternative to chlorine and bromine. Unlike chlorinated pools, water treated with iodine decreases eye irritation among swimmers and provides a level of disinfection more stable to adverse conditions. However, its toxic and corrosive properties, along with the difficulties of dissolving it in water, have limited its widespread acceptance. One of the most common applications of iodine is in poultry industry process water.\u003c\/p\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 12.5 mg\/L (ppm) (as I\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th ed. DPDMethod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eround, 24.6 mm diameter (22 mm inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDate, time of last calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel B\/W LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e50 measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA battery (3 pcs.) \/ \u0026gt; 800 measurements (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 15 minutes of inactivity (30 minutes before a READ measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); relative humidity: 100% (IP 67, floating case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e380g with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e142.5 x 102.5 x 50.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-97718 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagents and CAL Check Standards\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-97718-11 CAL Check Standard Cuvettes\u003cbr\u003eHI-93718-01 Reagents 100 tests\u003cbr\u003eHI-93718-03 Reagents 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57247042896245,"sku":"HI-97718","price":495.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-97718-iodine-photometer-range-00-to-125-mgl-ppm.jpg?v=1780481971"},{"product_id":"hanna-instruments-hi-6522-ph-orp-ise-ec-multiparameter-modular-benchtop-meter","title":"Hanna Instruments HI-6522 pH\/ORP\/ISE + EC Multiparameter Modular Benchtop Meter","description":"\u003cp\u003e\u003cspan\u003eHI-6522 pH\/ORP\/ISE + EC Multiparameter Modular Benchtop Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis kit includes the necessary modules and probes to measure pH, temperature and conductivity, providing everything needed to start measuring straight out of the box. This advanced multimeter features WiFi and ethernet connectivity. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-features product__features\"\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e EC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eISE\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eORP\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003epH\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cp\u003eThe HI-6522 Kit for the HI-6000 includes the HI-6000 modular laboratory meter system, a HI-6000-2 pH\/ISE module and a HI-6000-3 EC module. Also included is the \u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/57-ph-electrode-glass-body-general-purpose-for-laboratory\"\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e\u003c\/a\u003e, \u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/2980-hi-7662-tw-temperature-probe\"\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e\u003c\/a\u003e and\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/2974-hi-7631233-platinum-four-ring-ec-and-resistivity-probe\"\u003eHI-7631233 EC and resistivity probe\u003c\/a\u003e\u003c\/span\u003e. This kit includes everything needed for the accurate measurement of EC and pH, including a calibration solution starter set for EC and pH.\u003c\/p\u003e\n\u003cp\u003eHI-6000 is a fully flexible measurement platform that can be customised according to the user’s application needs. Designed and developed using the latest generation technologies, it gives complete control over measurements.\u003c\/p\u003e\n\u003cp\u003eThis kit is compatible with a wide range of Hanna Instruments electrodes for ISE measurement. For advice on the best electrodes for your needs speak to our in-house specialists directly.\u003c\/p\u003e\n\u003cp\u003eSix different pre-built kits are available for the HI-6000 multimeter, including the modules and electrodes required for laboratory-grade measurement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2988-hi-6222-02-ph-orp-ise-multiparameter-modular-benchtop-system\"\u003eHI-6222 pH\/ORP\/ISE Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2989-hi-6522-02-ph-orp-ise-ec-multiparameter-modular-benchtop-system\"\u003eHI-6522 pH\/ORP\/ISE + EC Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2990-hi-6542-02-ph-orp-ise-optical-do-multiparameter-modular-benchtop-system\"\u003eHI-6542 pH\/ORP\/ISE + Optical DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2991-hi-6542p-02-ph-orp-ise-polarographic-do-multiparameter-modular-benchtop-system\"\u003eHI-6542\/P pH\/ORP\/ISE + Polarographic DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2992-hi-6553-02-ph-orp-ise-ec-optical-do-multiparameter-modular-benchtop-system\"\u003eHI-6553 pH\/ORP\/ISE + EC + Optical DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2993-hi-6553p-02-ph-orp-ise-ec-polarographic-do-multiparameter-modular-benchtop-system\"\u003eHI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003eSpecification:\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHI-6522-02 pH\/ORP\/ISE + EC Kit\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003emV\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1 x 10\u003csup\u003e-6\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eto 9.99 x 10\u003csup\u003e10\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econcentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1; 0.1; 0.01; 0.001 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV offset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003epH Calibration\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard buffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOffset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable; Isopotential point: -2.000 to 20.000pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConductivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm; 100.0 to 999.9 μS\/cm;\u003cbr\u003e1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e0.0500 to 200.00 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Type\u003c\/td\u003e\n\u003ctd\u003eautomatic; manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eSingle\u003cbr\u003eMultiple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration solutions\u003c\/td\u003e\n\u003ctd\u003e84.00 μS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear, natural, standard, disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003eRange: 5.0 to 30.0˚C (41.0 to 86.0˚C\u003cbr\u003eResolution 0.1˚C \/ 0.1˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00%\/˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eResistivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 Ω・cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTotal Dissolved Solids (TDS)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSalinity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU - Practical Scale\u003cbr\u003e0.00 to 80.00 ppt - Natural Sea Water\u003cbr\u003e0.0 to 400.0 % - Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 for Practical Scale \/ Natural Sea Water\u003cbr\u003e0.1 % for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 point for Percent Scale, using 100% salinity calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C; -4.0 to 248.0˚F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57492952875381,"sku":"HI-6522-02","price":1282.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-6522-02-ph-orp-ise-ec-multiparameter-modular-benchtop-system.jpg?v=1786545063"}],"url":"https:\/\/testallwater.co.uk\/collections\/process-water-and-water-quality.oembed?page=2","provider":"Test All Water","version":"1.0","type":"link"}