{"title":"Process Instrumentation and Control","description":null,"products":[{"product_id":"hanna-instruments-83306-02-multi-parameter-environmental-analysis-photometer-with-ph-meter","title":"Hanna Instruments-83306-02 Multi-parameter Environmental Analysis Photometer with pH meter","description":"One meter can be used for both photometric and pH measurements. Hanna Instruments-83306 is a compact, multi-parameter photometer for use in the environmental lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 23 different programmed methods measuring 16 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. Environmental parameters include nitrate, phosphorous and dissolved oxygen.\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHanna Instruments-83306-02 Environmental Analysis Photometer with pH digital input \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe photometer features an innovative optical system that uses LEDs, narrow band interference filters, a focusing lens, and a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source which ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83306 was developed to measure the most common parameters in environmental water quality monitoring. Nutrients such as nitrates and phosphates are key indicators of nutrient pollution from agricultural sources and are considered dangerous to environmental waters. Too few nutrients and waters will be unable to sustain healthy ecosystems; too many nutrients and algal blooms can form, which can be detrimental to water quality and aquatic health. Dissolved oxygen is an essential to performing biological processes for many forms of aquatic life, such as fish, plants and microorganisms.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83306 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the four wavelengths of light (420 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability, the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eKey features: \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHigh Efficiency LED Light Source\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHigh Quality Narrow Band Interference Filters \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eReference Detector for a Stable Light Source \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eLarge Cuvette Size \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eFocusing Lens for Greater Light Yield \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354373075095,"sku":"HI-83306-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83306-02_multi-parameter_environmental_analysis_photometer_with_ph_meter_357082fd-4ba0-4d5e-8514-04ae70880382.jpg?v=1624278761"},{"product_id":"hanna-instruments-83300-02-multi-parameter-benchtop-photometer-ph-meter","title":"Hanna Instruments-83300-02 Multi-parameter Benchtop Photometer \u0026 pH meter","description":"One meter can be used for both photometric and pH measurements. The meter has 60 different programmed methods measuring 37 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83300 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003cbr\u003e\u003ch3\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-83300 is a compact, multi-parameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFrom Aluminium to Zinc, the Hanna Instruments-83300 benchtop photometer measures 37 water quality parameters using 60 different methods. The photometer features an innovative optical system that uses LEDs, narrow band interference filters, and a focusing lens. It also has a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83300 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375467159,"sku":"HI-83300-02","price":1489.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_3_dc75fef9-64f1-4563-8b90-e8a5f746505a.jpg?v=1624278832"},{"product_id":"hanna-instruments-83325-02-multi-parameter-photometer-with-ph-meter-for-plant-nutrient-analysis","title":"Hanna Instruments-83325-02 Multi-parameter Photometer with pH meter for Plant Nutrient analysis","description":"\u003cp\u003eOne meter can be used for both photometric and pH measurements. The Hanna Instruments-83325 benchtop photometer measures 8 different plant nutrient water quality parameters using 9 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time. Key parameters are: Ammonia, Calcium, Magnesium, Nitrate, Phosphorus, Potassium, Sulphate and pH.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eHanna Instruments-83325-02 Plant Nutrient Analysis Photometer with pH meter\u003c\/h3\u003e\n\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/p\u003e\n\u003cp\u003eConsistent and thorough monitoring of plant nutrients is essential to maintaining healthy growth and reproduction. This is easy with the Hanna Instruments-83325, a comprehensive way to monitor vital plant nutrients such as potassium, calcium and magnesium. Required in large quantities, potassium plays a vital role in water uptake and enzyme regulation. Calcium helps to strengthen plant cell walls protecting against heat stress while magnesium helps build a strong immune system.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83325 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the three wavelengths of light (420 nm, 466 nm, and 525 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch3\u003eKey features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cli\u003eError Messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354376482967,"sku":"HI-83325-02","price":853.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_4_244ef4df-8e10-4227-a272-550e2bc9fb4e.jpg?v=1624278870"},{"product_id":"hanna-instruments-83308-water-conditioning-photometer-with-ph-meter","title":"Hanna Instruments-83308 Water Conditioning Photometer with pH meter","description":"\u003cp\u003eOne meter can be used for both photometric and pH measurements. This meter has 23 different programmed methods measuring 15 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. Water conditioning parameters include Fluoride, Chlorine, Ammonia, Manganese, Copper, Iron, Silver and Zinc.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 benchtop photometer measures 15 different key water quality parameters using 23 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 was developed to measure the most common parameters in water quality monitoring. One important parameter to test water quality is iron since it can affect colour, odour, and turbidity and can also be the most troublesome factor for appliances and surfaces in contact with water. High levels of iron in water can result in clogged water pipes or heat exchangers.\u003c\/p\u003e\n\u003cp\u003eAdditionally, Ammonia detection in water treatment systems is particularly important for aquarium owners and fish farm operators since ammonia is highly soluble in water and extremely toxic to fish. One other important parameter in water quality monitoring is Fluoride. Fluoride is best known for preventing tooth decay. While it does help prevent tooth decay, too little fluoride can be ineffective while too much can cause staining of teeth.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the four wavelengths of light (420 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch3\u003eKey features:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eError Messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Focusing Lens for Greater Light Yield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\n\u003cdiv id=\"product_tabs\" class=\"product__tabs\"\u003e\n\u003cdiv class=\"tabs\"\u003e\n\u003cdiv class=\"tab specification active\"\u003e\n\u003cdiv class=\"tab__content\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pH electrode input and 4 photometer wavelengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital pH electrode (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLog on demand with user name and sample ID optional input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-A host for flash drive; micro-USB-B for power and computer connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibration data for connected pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 VDC Li-polymer rechargeable battery\/ \u0026gt;500 photometric measurements or 50 hours of continuous pH measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e206 x 177 x 97mm (8.1 x 7.0 x 3.8\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon Photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e8nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter wavelength accruacy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e+-1nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRound, 24.6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Methods\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-83308 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAMMONIA\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 3.00 mg\/L (as NH3-N) Medium Range: 0.00 to 10.00 mg\/L (as NH3-N) High Range: 0.0 to 100.0 mg\/L (as NH3-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading Medium Range: ±0.05 mg\/L ±5% of reading High range: ±0.5 mg\/L ±5% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCHLORINE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA 330.5 DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCOPPER\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.500 mg\/L (as Cu2+) High range: 0.00 to 5.00 mg\/L (as Cu2+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±5% of reading High Range ±0.02 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFLUORIDE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as F-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIRON\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.600 mg\/L (as Fe) High Range: 0.00 to 5.00 mg\/L (as Fe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±8% of reading High Range: ±0.04 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the TPTZ Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMANGANESE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 300 µg\/L (as Mn) High range: 0.0 to 20.0 mg\/L (as Mn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.02 mg\/L ±3% of reading; High Range: ±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMOLYBDENUM\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 40.0 mg\/L (as Mo6+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the mercaptoacetic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNICKEL\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.000 mg\/L (as Ni); High Range: 0.00 to 7.00 g\/L (as Ni)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow range: ±0.010 mg\/L ±7% of reading High Range: ±0.07 g\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN method; High Range: Adaptation of the photometric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNITRATE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L (as NO3-- N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±10% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the cadmium reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOXYGEN, DISSOLVED\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L (as O2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.4 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003epH\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 0.1 pH pH electrode: 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: ±0.1 pH pH electrode: ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eclean electrode and check buffer\/check probe displayed during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: phenol red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePHOSPHATE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.50 mg\/L (as PO43-) High range: 0.0 to 30.0 mg\/L (as PO43-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading High Range: ±1 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the Ascorbic Acid method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSILICA\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as SiO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSILVER\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.000 mg\/L (as Ag)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.020 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the PAN method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eZINC\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.00 mg\/L (as Zn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eREAGENTS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia HR, MR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93733-01 (100 tests); HI-93733-03 (300 tests); MR - HI-93715-01 (100 tests); HI-93715-03 (300 tests); LR - HI-93700-01 (100 tests); HI-93700-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine - Free\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Total\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)\u003cbr\u003eChlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93702-01 (100 tests); HI-93702-03 (300 tests)\u003cbr\u003eLR - HI-95747-01 (100 tests); HI-95747-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93739-01 (100 tests); HI-93739-03 (300 tests)\u003cbr\u003eLR - HI-93729-01 (100 tests); HI-93729-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93721-01 (100 tests); HI-93721-03 (300 tests)\u003cbr\u003eLR - HI-93746-01 (100 tests); HI-93746-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93709-01 (100 tests); HI-93709-03 (300 tests)\u003cbr\u003eLR - HI-93748-01 (50 tests); HI-93748-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93730-01 (100 tests); HI-93730-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel - HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93726-01 (100 tests); HI-93726-03 (300 tests)\u003cbr\u003eLR - HI-93740-01 (50 tests); HI-93740-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93728-01 (100 tests); HI-93728-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved (DO)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93732-01 (100 tests); HI-93732-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93710-01 (100 tests); HI-93710-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate - HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93717-01 (100 tests); HI-93717-03 (300 tests)\u003cbr\u003eLR - HI-93713-01 (100 tests); HI-93713-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica – LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLR - HI-93705-01 (100 tests); HI-93705-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93737-01 (50 tests); HI-93737-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93731-01 (100 tests); HI-93731-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354377793687,"sku":"HI-83308-02","price":717.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83308_water_conditioning_photometer_with_ph_meter_65bd256c-bf7f-4276-8991-38095b909212.jpg?v=1624278907"},{"product_id":"hanna-instruments-83305-02-multi-parameter-photometer-ph-meter-for-boiling-and-cooling-towers","title":"Hanna Instruments-83305-02 Multi-parameter Photometer \u0026 pH Meter for Boiling and Cooling towers","description":"One meter can be used for both photometric and pH measurements. The meter has 30 different programmed methods measuring 18 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves.\u003cbr\u003e\u003ch3\u003eHanna Instruments-83305-02 Boiler and Cooling Tower Photometer with pH digital input\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable benchtop space, the Hanna Instruments-83305 doubles as a professional pH meter with its digital pH\/temperature electrode input. Suitable for use in boiling and cooling tower applications, parameters specific to boiling and cooling towers include oxygen scavengers and silica which are important for maintaining equipment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable laboratory benchtop space, the Hanna Instruments-83305 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis photometer features an innovative optical system that uses LEDs, narrow band interference filters, a focusing lens, plus a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source which ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eSpecifically designed for use with boilers and cooling towers, the Hanna Instruments-83305 is a comprehensive way to maintain precise water conditions in systems. Problems such as corrosion, deposition, and microbial growth can occur if these key parameters, such as oxygen scavengers and silica, aren't maintained. Oxygen scavengers are added to remove residual dissolved oxygen in boiler feed water that can cause corrosion in a steam generating plant. It is important that levels of oxygen scavengers be routinely checked to prevent against corrosion and ensure that equipment is working efficiently. Boiler water maintenance is necessary to prevent or control deposit formation as seen with silica. Silica contamination can reduce system efficiency and increase maintenance of equipment due to scaling.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built-in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built-in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83305 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability, the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354378645655,"sku":"HI-83305-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83305-02_multi-parameter_photometer_ph_meter_for_boiling_and_cooling_towers_181f2f4b-06e5-4b51-9be1-abf10313a96a.jpg?v=1624278958"},{"product_id":"hanna-instruments-7871-220-mini-level-controller-control-relay-high-and-low-220v","title":"Hanna Instruments-7871\/220 Mini Level Controller, control relay: high and low, 220V","description":"Hanna Instruments-7871 mini-level controller is ideal for liquid level control over distances of up to 100 meters (330 feet). It is highly compact and will fit in tight spaces.\u003cbr\u003e\u003ch3\u003eMini Level Controller, control relay: high and low, 220, 240V\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThese easy-to-use controllers are ideal for nearly any liquid level application, such as industrial and municipal water treatment, nutrient tank control in farming, hydroponics, aquaculture applications and plating rinse baths.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-7871 includes an overflow alarm and can be connected to a 2-wire transmitter, which is ideal for level monitoring in remote applications.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA complete liquid level measuring system requires:\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eController (Hanna Instruments-7871)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003ebar holder with amplifier circuitry (Hanna Instruments-7874)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eMeasuring bars (Hanna Instruments-731324)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUndecal connector (Hanna Instruments-7164)\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-7871 requires four bars with the additional bar used for overflow measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information:\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-7871 is supplied with mounting brackets and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354380480663,"sku":"HI-7871\/220","price":127.78,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-787120_mini_level_controller_control_relay_high_and_low_220v.jpg?v=1624279023"},{"product_id":"hanna-instruments-943500d-conductivity-controller-low-range-199-9-µs-cm","title":"Hanna Instruments-943500D Conductivity Controller (Low Range @ 199.9 µS\/cm)","description":"Hanna Instruments-943500 are panel-mounted conductivity controllers designed for simplicity of use in a wide range of industrial process applications. Four different models are available with different measurement ranges, to satisfy any application requirements.\u003cbr\u003e\u003cp\u003eFour different models are available with different measurement ranges, to satisfy any application requirements.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe output configuration for connecting a recorder or a PLC can be chosen between 0-20 or 4-20 mA.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe LED on the front panel indicates the operating status of the controller.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe automatic temperature compensation (ATC) is performed directly by the Hanna Instruments-7638 probe with built-in temperature sensor.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe front panel is protected behind a transparent splash-proof cover.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information:\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-943500 series is supplied with mounting brackets and instructions.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500A: 0.0 to 199.9 mS\/cm\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500B: 0.00 to 19.99 mS\/cm\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500C: 0 to 1999 µS\/cm\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500D: 0.0 to 199.9 µS\/cm\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354380578967,"sku":"HI-943500D","price":756.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-943500d_conductivity_controller_low_range_199.9_scm_0a23d3d4-993d-4a95-8dd7-77731bc238f0.jpg?v=1624279024"},{"product_id":"bl-983320-0-conductivity-mini-controller-range-199-9-µs-cm","title":"Hanna Instruments Conductivity Mini Controller (Range 199.9 µS\/cm) BL-983320-0","description":"The Hanna mini controllers have been specially designed for water conditioning and growing applications. The BL-983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 μS\/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. Compact in size, they can be mounted in confined spaces or even right next to the vat or barrel containing the chemicals.\u003cbr\u003e\n\u003cp\u003eWhen in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionised) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL-983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.\u003c\/p\u003e\n\u003ch3\u003eAdjustable Dry Contact Dosing Relay\u003c\/h3\u003e\n\u003cp\u003eThe BL-983320 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch3\u003eProgrammable Overdose Protection\u003c\/h3\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch3\u003eRelay Control Override\u003c\/h3\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch3\u003eMulticolour LED Indicator\u003c\/h3\u003e\n\u003cp\u003eMulticolour LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFuse Protected Dosing Contacts\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLabelled Termination Connections\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQuick-connect terminal blocks are clearly labelled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe BL-983320 mini controller uses the HI-7634-00 conductivity probe that is available with different cable lengths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*HI-7634-00 is not included and must be ordered separately\u003c\/p\u003e\n\u003ch3\u003eOrder Information:\u003c\/h3\u003e\n\u003cp\u003eThe BL-983320 is supplied with mounting brackets, transparent cover, and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354386411671,"sku":"BL-983320-0","price":231.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983320-0_conductivity_mini_controller_range_199.9_scm_f2017210-2133-4214-a3fa-72bca529132b.jpg?v=1624279134"},{"product_id":"hanna-instruments-7873-220-liquid-level-controller","title":"Hanna Instruments-7873\/220 Liquid Level Controller","description":"Hanna Instruments-7873 mini-level controller is ideal for liquid level control over distances of up to 100 meters (330 feet). It is highly compact and will fit in tight spaces.\u003cbr\u003e\u003cp\u003eThese easy-to-use controllers are ideal for nearly any liquid level application, such as industrial and municipal water treatment, nutrient tank control in farming, hydroponics, aquaculture applications and plating rinse baths.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-7873 includes an overflow alarm and can be connected to a 2-wire transmitter, which is ideal for level monitoring in remote applications.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA complete liquid level measuring system requires:\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eController (Hanna Instruments-7873)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003ebar holder with amplifier circuitry (Hanna Instruments-7874)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eMeasuring bars (Hanna Instruments-731324)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUndecal connector (Hanna Instruments-7164)\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-7873 requires four bars with the additional bar used for overflow measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information:\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-7873 is supplied with mounting brackets and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354393915543,"sku":"HI-7873\/220","price":163.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-7873220_liquid_level_controller.jpg?v=1624279354"},{"product_id":"bl-983314-0-resistivity-mini-controller-1","title":"BL-983314-0 Resistivity Mini Controller","description":"The BL-983314 is a simple to operate resistivity controller designed for ultra pure water, reverse osmosis, and water conditioning applications. The BL-983314 resistivity controller is also ideal for continuous monitoring to process solutions. Setpoint and calibration are manually adjusted with a trimmer and the alarm relay allows for simple control.\u003cbr\u003e\u003ch3\u003eAbout the BL-983314 Resistivity Mini Controllers\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFire retardant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSelectable overdose protection system\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSplash-resistant cover\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eReadings are automatically temperature compensated with three different coefficients (β=2.4, 3.5 or 4.5 %\/°C). The alarm contact can be used for connection to an alarm, pump, solenoid or dosing system.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe relay contact is open when readings are higher than the setpoint, while for measurements lower than setpoint, the relay contact is closed. The hysteresis is typically 0.20 MΩ •cm from the setpoint.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMeasurements are displayed on the LCD and the multi-coloured LED continuously indicates if the controller is in measurement, dosing, or alarm mode. Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits operators to enable or disable the dosing relay according to need.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe overtime control system advises users when the relay is active for too long, helping to prevent over-dosage.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354397061271,"sku":"BL-983314-0","price":350.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983314-0_resistivity_mini_controller_1_6165b1eb-d17a-47d9-87e4-fb041ae86748.jpg?v=1624279469"},{"product_id":"bl-982411-1-orp-controller-range-0-to-1000-mv-1","title":"BL-982411-1 ORP Controller (Range 0 to 1000 mV)","description":"\u003cp\u003eBL 982411 is an ORP mini controller for panel mounting, specially designed for swimming pools and spas. Thanks to its compact size, BL 982411 can be installed in small spaces.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eBL 982411 is an ORP mini controller for panel mounting, specially designed for swimming pools and spas. Thanks to its compact size, BL 982411 can be installed in small spaces. BL 982411 is the ideal solution for those who have always checked ORP manually. Thanks to the automatic dosing, this mini controller will significantly reduce maintenance time.\u003c\/p\u003e\n\u003cp\u003eBL 982411 can be used with any ORP electrode with standard BNC connector. The instrument measures ORP in the 0 to 1000 mV range and shows the readings on the large display.\u003c\/p\u003e\n\u003cp\u003eThe status LED continuously indicates if the controller is in measurement, dosing or alarm mode.\u003c\/p\u003e\n\u003cp\u003eBL 982411 is also provided with a relay for selecting the dosing direction, oxidising or reducing.\u003c\/p\u003e\n\u003cp\u003eYou can also choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits you to enable or disable the dosing relay according to your need.\u003c\/p\u003e\n\u003cp\u003eThe overtime control system advises you when the relay is active for too long, helping to prevent over-dosage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL 982411 is supplied with mounting brackets, transparent cover, and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354400698519,"sku":"BL-982411-1","price":231.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-982411-1_orp_controller_range_0_to_1000_mv_3aa47787-c9aa-4d4c-8381-e228819fb2b0.jpg?v=1624279530"},{"product_id":"bl-983314-1-panel-mounted-resistivity-controller-115-230v-1","title":"BL-983314-1 Panel mounted resistivity controller 115\/230V","description":"\u003cp\u003eThe BL-983314 is a simple to operate resistivity controller designed for ultra pure water, reverse osmosis, and water conditioning applications. The BL-983314 resistivity controller is also ideal for continuous monitoring of process solutions. Setpoint and calibration are manually adjusted with a trimmer and the alarm relay allows for simple control.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFire-retardant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSelectable overdose protection system\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSplash-resistant cover\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eReadings are automatically temperature compensated, with three different coefficients (β=2.4, 3.5 or 4.5 %\/°C). The alarm contact can be used for connection to an alarm, pump, solenoid or dosing system.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe relay contact is open when readings are higher than the setpoint, while for measurements lower than setpoint, the relay contact is closed. The hysteresis is typically 0.20 MΩ•cm from the setpoint.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMeasurements are displayed on the LCD and the multi-coloured LED continuously indicates if the controller is in measurement, dosing, or alarm mode. Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits operators to enable or disable the dosing relay according to need.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe overtime control system advises users when the relay is active for too long, helping to prevent over-dosage.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354418950295,"sku":"BL-983314-1","price":350.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983314-1_panel_mounted_resistivity_controller_115230v_6509caee-4df1-408c-a645-a22340c09ff8.jpg?v=1624279827"},{"product_id":"bl-983322-0-conductivity-controller-low-range-19-99-µs-c","title":"BL-983322-0 Conductivity Controller (Low Range@ 19.99 µS\/c)","description":"\u003cform action=\"https:\/\/www.hannainstruments.co.uk\/checkout\/cart\/add\/uenc\/aHR0cHM6Ly93d3cuaGFubmFpbnN0cnVtZW50cy5jby51ay9jb25kdWN0aXZpdHktY29udHJvbGxlci1sb3ctcmFuZ2VhdC0xOS05OS1zLWNtLmh0bWw,\/product\/1806\/form_key\/5ocYvWr83w8h9Y6w\/\" id=\"product_addtocart_form\" method=\"post\"\u003e\n\u003cdiv class=\"product-view__product-essential__product-shop col-sm-5 col-xs-12 rem-pad-mobile rem-p-r\"\u003e\n\u003cdiv class=\"product-view__product-essential__product-shop__short-description\"\u003e\n\u003cdiv class=\"std\"\u003e\n\u003cp\u003eThe Hanna mini controllers have been specially designed for water conditioning and growing applications. The BL-983322 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream. The device features a large LCD with protective cover.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/form\u003e\n\u003cdiv class=\"product-view__roundels col-xs-12 col-sm-5 rem-p-r\"\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003eWater Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.\u003c\/div\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eMains powered - All mains operated equipment is compatible with UK AC voltage and frequency – 230V, 50Hz.\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\nUsers may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionised) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL-983322 can also be used to monitor the quality of water from DI tanks or from a distillation apparatus. The BL-983322 measures EC from 0.00 to 19.99 μS\/cm.\u003c\/div\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eAdjustable Dry Contact Dosing Relay\u003c\/h3\u003e\n\u003cp\u003eThe BL-983322 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch3\u003eProgrammable Overdose Protection\u003c\/h3\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch3\u003eRelay Control Override\u003c\/h3\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch3\u003eMulticolour LED Indicator\u003c\/h3\u003e\n\u003cp\u003eMulticolour LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFuse Protected Dosing Contacts\u003c\/h3\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch3\u003eLabelled Termination Connections\u003c\/h3\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labelled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003ch3\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h3\u003e\n\u003cp\u003eThe BL-983322 mini controller uses the HI-7634-00 conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003cp\u003e*HI-7634-00 is not included and must be ordered separately.\u003c\/p\u003e\n\u003ch3\u003eOrder Information:\u003c\/h3\u003e\n\u003cp\u003eThe BL 983322 is supplied with mounting brackets, transparent cover, and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354435891351,"sku":"BL-983322-0","price":231.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983322-0_conductivity_controller_low_range_19.99_sc_5b0e14b9-11a3-4168-9f7e-4fc534780897.jpg?v=1624280078"},{"product_id":"hanna-instruments-99300-ec-tds-temperature-meter","title":"Hanna Instruments-99300 EC\/TDS\/Temperature Meter","description":"\u003cdiv class=\"row\"\u003e\n\u003cp\u003eThe HI-99300 is a portable, EC\/TDS\/temperature meter that measures low range conductivity in µS\/cm and TDS in ppm. It is housed in a case rated for IP67 conditions.\u003c\/p\u003e\n\u003cp\u003eThis instrument offers single point, automatic calibration with automatically temperature compensated measurements. The compensation coefficient and EC\/TDS conversion factor are user-selectable from 0.45 to 1.00 and temperature coefficient is selectable from 0.0 to 2.4%\/°C.\u003c\/p\u003e\n\u003cp\u003eThe meter easily fits in the palm of your hand and the bottom probe connection ensures the electrode cable doesn't get in your way. The large, multi-level LCD displays the primary reading, temperature and calibration guides simultaneously. Symbols and messages on the LCD indicate meter status and guides users through operations.\u003c\/p\u003e\n\u003cp\u003eAt start-up, the meter shows the remaining battery percentage and when a low battery condition is detected, a battery symbol appears on the LCD to advise the user that only a few hours of working time is left.\u003c\/p\u003e\n\u003cp\u003eThe HI-76306 EC\/TDS\/temperature probe resists clogging and is easy to clean.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIdeal for\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePure Water\u003c\/li\u003e\n\u003cli\u003eTap Water\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMain benefits\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli\u003eBattery % displayed on start-up\u003c\/li\u003e\n\u003cli\u003eCompact, heavy-duty and water resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eKey features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAmperometric probe technology\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eAutomatic single calibration with calibration indicator\u003c\/li\u003e\n\u003cli\u003eOn-screen tutorial messages for calibration and set-up\u003c\/li\u003e\n\u003cli\u003eReplacement probe - HI-763063\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange - EC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange - TDS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange - Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution - EC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution - TDS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution - Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy - EC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy - TDS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy - Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ ±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eadjustable, from 0.45 to 1.00 with 0.01 increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic, 1 point at 1382 ppm (CONV 0.5)\u003cbr\u003eor at 1500 ppm (CONV 0.7)\u003cbr\u003eor at 1413 µS\/cm (others)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, 0 to 60°C (32 to 140°F) with ß adjustable\u003cbr\u003efrom 0.0 to 2.4% with 0.1% increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI 763063, EC\/TDS\/temperature sensor, with DIN connector,\u003cbr\u003e1 m (3.3') cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x 1.5V AAA \/ approx. 500 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e154 x 63 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e196g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354438906007,"sku":"HI-99300N","price":274.01,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-99300_ectdstemperature_meter_02294a3d-d35d-40e5-a1de-4bc29072074f.jpg?v=1624280137"},{"product_id":"bl-983324-0-tds-mini-controller-range-up-to-49-9-ppm-1","title":"BL-983324-0 TDS Mini Controller (Range up to 49.9 ppm)","description":"\u003cp\u003eBL-983324 is a panel mounted TDS controller, designed for easy installation, configuration and maintenance.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe BL-983324 is a compact, panel mounted, process controller for measuring total dissolved solids (TDS) of a process stream that is within the 0.0 to 49.9 ppm (mg\/L) range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe relay can be used to supply power to a dosing pump or a solenoid connected to a valve. The BL-983324 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e*The BL983324 uses a 0.5 conversion factor in which 1.0 μS\/cm = 0.5 ppm.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eBL-983324-0 TDS Mini Controller (Range up to 49.9 ppm)\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe meter is provided with a dosing relay, activated when the TDS reading exceeds the set point value.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMeasurements are automatically compensated for temperature variations and shown on the large display.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA multi-coloured LED on the front panel continuously indicates if the mini controller is in measurement, dosing or alarm mode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eWiring and external device connections are extremely simple to perform through the terminals on the rear of the instrument.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eChoose an automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations as it allows the dosing relay to be enabled or disabled according to requirements.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe overtime control system advises you when the relay is active too long, helping to prevent over dosage.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eModel is available with power supply input at 230 Vac - 12 Vdc.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information:\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe BL-983324 is supplied with mounting brackets, transparent cover, and instructions.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eAdjustable Dry Contact Dosing Relay\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe BL-983324-0 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eProgrammable Overdose Protection\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eRelay Control Override\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eMulticolour LED Indicator\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eMulticolour LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFuse Protected Dosing Contacts\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLabelled Termination Connections\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eQuick-connect terminal blocks are clearly labelled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe BL-983322 mini controller uses the HI-7634-00 conductivity probe that is available with different cable lengths.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e*HI-7634-00 is not included and must be ordered separately.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354443002007,"sku":"BL-983324-0","price":231.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983324-0_tds_mini_controller_range_up_to_49.9_ppm_1919e69a-073f-48a7-a34c-387ee3328e2d.jpg?v=1624280279"},{"product_id":"hanna-instruments-7874-level-transmitter","title":"Hanna Instruments-7874 Level Transmitter","description":"\u003cp\u003e\u003cspan\u003eThe Hanna Instruments-7874 transmitter has been designed to be combined with the Hanna Instruments-7871 and Hanna Instruments-7873 level controllers. The transmitter is housed in a durable and water resistant ABS body, and allows the user to easily adjust the length of the sensor bars according to the specific need.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eLevel Transmitter\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAccurate level control is critical to many industrial applications, especially for process adjustments using aggressive chemicals. Our sensor bars are built with stainless steel for long life even in harsh conditions. They are easy to install and ideal for monitoring tanks and water conditioning plants.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-7874 transmitter has been designed to be combined with the Hanna Instruments-7871 and Hanna Instruments-7873 level controllers. The transmitter is housed in a durable and water resistant ABS body, and allows the user to easily adjust the length of the sensor bars according to the specific need.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-7874 is supplied with a sturdy mounting bracket for quick and easy installation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003ePlease note: Hanna Instruments-731324 measuring bar set is sold separately.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354447786135,"sku":"HI-7874","price":157.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-7874_level_transmitter_57495ccb-1114-4b8f-abbe-df76b03ea609.jpg?v=1624280331"},{"product_id":"hanna-instruments-hi-6522-ph-orp-ise-ec-multiparameter-modular-benchtop-meter","title":"Hanna Instruments HI-6522 pH\/ORP\/ISE + EC Multiparameter Modular Benchtop Meter","description":"\u003cp\u003e\u003cspan\u003eHI-6522 pH\/ORP\/ISE + EC Multiparameter Modular Benchtop Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis kit includes the necessary modules and probes to measure pH, temperature and conductivity, providing everything needed to start measuring straight out of the box. This advanced multimeter features WiFi and ethernet connectivity. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-features product__features\"\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e EC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eISE\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eORP\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003epH\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cp\u003eThe HI-6522 Kit for the HI-6000 includes the HI-6000 modular laboratory meter system, a HI-6000-2 pH\/ISE module and a HI-6000-3 EC module. Also included is the \u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/57-ph-electrode-glass-body-general-purpose-for-laboratory\"\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e\u003c\/a\u003e, \u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/2980-hi-7662-tw-temperature-probe\"\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e\u003c\/a\u003e and\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/2974-hi-7631233-platinum-four-ring-ec-and-resistivity-probe\"\u003eHI-7631233 EC and resistivity probe\u003c\/a\u003e\u003c\/span\u003e. This kit includes everything needed for the accurate measurement of EC and pH, including a calibration solution starter set for EC and pH.\u003c\/p\u003e\n\u003cp\u003eHI-6000 is a fully flexible measurement platform that can be customised according to the user’s application needs. Designed and developed using the latest generation technologies, it gives complete control over measurements.\u003c\/p\u003e\n\u003cp\u003eThis kit is compatible with a wide range of Hanna Instruments electrodes for ISE measurement. For advice on the best electrodes for your needs speak to our in-house specialists directly.\u003c\/p\u003e\n\u003cp\u003eSix different pre-built kits are available for the HI-6000 multimeter, including the modules and electrodes required for laboratory-grade measurement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2988-hi-6222-02-ph-orp-ise-multiparameter-modular-benchtop-system\"\u003eHI-6222 pH\/ORP\/ISE Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2989-hi-6522-02-ph-orp-ise-ec-multiparameter-modular-benchtop-system\"\u003eHI-6522 pH\/ORP\/ISE + EC Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2990-hi-6542-02-ph-orp-ise-optical-do-multiparameter-modular-benchtop-system\"\u003eHI-6542 pH\/ORP\/ISE + Optical DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2991-hi-6542p-02-ph-orp-ise-polarographic-do-multiparameter-modular-benchtop-system\"\u003eHI-6542\/P pH\/ORP\/ISE + Polarographic DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2992-hi-6553-02-ph-orp-ise-ec-optical-do-multiparameter-modular-benchtop-system\"\u003eHI-6553 pH\/ORP\/ISE + EC + Optical DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2993-hi-6553p-02-ph-orp-ise-ec-polarographic-do-multiparameter-modular-benchtop-system\"\u003eHI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003eSpecification:\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHI-6522-02 pH\/ORP\/ISE + EC Kit\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003emV\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1 x 10\u003csup\u003e-6\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eto 9.99 x 10\u003csup\u003e10\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econcentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1; 0.1; 0.01; 0.001 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV offset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003epH Calibration\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard buffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOffset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable; Isopotential point: -2.000 to 20.000pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConductivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm; 100.0 to 999.9 μS\/cm;\u003cbr\u003e1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e0.0500 to 200.00 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Type\u003c\/td\u003e\n\u003ctd\u003eautomatic; manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eSingle\u003cbr\u003eMultiple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration solutions\u003c\/td\u003e\n\u003ctd\u003e84.00 μS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear, natural, standard, disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003eRange: 5.0 to 30.0˚C (41.0 to 86.0˚C\u003cbr\u003eResolution 0.1˚C \/ 0.1˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00%\/˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eResistivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 Ω・cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTotal Dissolved Solids (TDS)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSalinity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU - Practical Scale\u003cbr\u003e0.00 to 80.00 ppt - Natural Sea Water\u003cbr\u003e0.0 to 400.0 % - Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 for Practical Scale \/ Natural Sea Water\u003cbr\u003e0.1 % for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 point for Percent Scale, using 100% salinity calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C; -4.0 to 248.0˚F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57492952875381,"sku":"HI-6522-02","price":1282.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-6522-02-ph-orp-ise-ec-multiparameter-modular-benchtop-system.jpg?v=1786545063"},{"product_id":"hanna-instruments-bl-983320-1-conductivity-mini-controller-range-199-9-us-cm","title":"Hanna Instruments BL-983320-1 Conductivity Mini Controller (Range 199.9 uS\/cm)","description":"\u003cp\u003eThese Hanna mini controllers have been specially designed for water conditioning and growing applications. Compact in size, they can be mounted in confined spaces or even right next to the vat or barrel containing the chemicals. \u003cbr\u003e\u003cbr\u003e These meters permit automatic control of installations previously checked manually. \u003cbr\u003e\u003cbr\u003e EC measurements are shown on the large display and the multicolored LED continuously indicates if the mini controller is in measurement, dosing or alarm mode. BL 983313 measures in the 0 to 1999 µS\/cm range, BL 983320 measures from 0.0 to 199.9 µS\/cm and BL 983322 from 0.00 to 19.99 µS\/cm. \u003cbr\u003e\u003cbr\u003e You can also choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits you to enable or disable the dosing relay according to your need. The overtime control system advices you when the relay is active for too long, helping to prevent over dosage.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOrder Information:\u003c\/b\u003e\u003cbr\u003e The BL 983320 is supplied with mounting brackets, transparent cover, and instructions.\u003c\/p\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eResolution\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003e0.1 µS\/cm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAccuracy\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003e±2% F.S.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProbe\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003eHI 7634-00 (not included)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTemperature Compensation\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003eAutomatic, 5 to 50°C (41 to 122°F) with ß = 2%\/°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCalibration\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003emanual, with CAL trimmer\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDosing Relay\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003e1, max 2A (fuse protected), 250 Vac, 30 Vdc\u003cbr\u003e contact closed when reading exceeds setpoint value\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSetpoint\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003eadjustable from 0 to 199.9 µS\/cm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOvertime\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003eadjustable, typically from 5 to approx. 30 minutes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Supply\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003eSee Chart\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDimensions\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9\")\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003eSee Chart\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003eHI-7634-00 (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic, 5 to 50°C (41 to 122°F) with ß = 2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003emanual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Relay\u003c\/td\u003e\n\u003ctd\u003e1, max 2A (fuse protected), 250 Vac, 30 Vdc contact closed when reading exceeds setpoint value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint\u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 199.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvertime\u003c\/td\u003e\n\u003ctd\u003eadjustable, typically from 5 to approx. 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/modules\/teapotknowledgehub\/uploads\/manbl_983320-60914d919b757.pdf\" target=\"_blank\"\u003eBL-983320-0 Conductivity Mini controller (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640052326773,"sku":"BL-983320-1","price":231.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/conductivity-mini-controller-range-199-9-s-cm.jpg?v=1791579727"},{"product_id":"hanna-instruments-hi-2600-ph-ec-and-do-benchtop-meter","title":"Hanna Instruments HI-2600 pH EC and DO Benchtop meter","description":"\u003cp\u003eHI-2600 enables fast, accurate measurements of pH, ORP, conductivity, TDS, dissolved oxygen, salinity, and temperature utilising Hanna digital probes. HI-2600 can be used as a portable device for field measurements (using its rechargeable battery) or used in a laboratory.\u003c\/p\u003e \u003cp\u003eThe HI-2600 architecture brings together Hanna’s visionary design capabilities, integrated production, and world class research and development.\u003c\/p\u003e\u003ch3\u003e\u003cspan\u003eHI-2600 pH EC and DO Benchtop meter\u003c\/span\u003e\u003c\/h3\u003e \u003cp\u003eHI-2600 benchtop meter enables fast, accurate measurements utilising the Hanna Instruments digital electrode \/ probes for pH (HI-11310), ORP (HI-36180), conductivity (HI-763100), or dissolved oxygen (HI-764080). Each digital electrode \/ probe has a unique serial number and the parameter that it measures is automatically identified by the meter.\u003c\/p\u003e \u003cp\u003eOnce connected, the single sensor or sensors are ready to measure the parameter along with temperature.\u003c\/p\u003e \u003cp\u003eThe intuitive design simplifies configuration, calibration, measurement, data logging and transfer of data to a USB thumb drive or computer. The benchtop meter offers a Basic Mode that streamlines measurement configuration and is useful for routine applications.\u003c\/p\u003e \u003cp\u003eThe compact meter (and probe) can be used as a portable device (using its rechargeable battery) or used as laboratory instrumentation.\u003c\/p\u003e \u003cp\u003eThe meter has a large display with capacitive keys which features a 5.5” (14 cm) LCD. The large display provides a 130 ° wide viewing angle.\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eMain feature\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eAutomatic parameter recognition\u003c\/li\u003e \u003cli\u003epH\/ORP choice of measurement units: pH, mV;\u003c\/li\u003e \u003cli\u003eEC choice of measurement unit: Conductivity: µS\/cm, mS\/cm\u003c\/li\u003e \u003cli\u003eTDS - ppm (mg\/L), g\/L\u003c\/li\u003e \u003cli\u003eSalinity - NaCl, PSU, g\/L\u003c\/li\u003e \u003cli\u003eDO choice of measurement unit: ppm (mg\/L), %\u003c\/li\u003e \u003cli\u003eAdjustable resolution for pH and EC measurements\u003c\/li\u003e \u003cli\u003eCAL Check indicators - HI-11310, HI-763100, HI-764080 digital probes only\u003c\/li\u003e \u003cli\u003eSensor Check indicators - HI-11311 and HI-12301 digital probes only\u003c\/li\u003e \u003cli\u003eBasic mode for simplified operation\u003c\/li\u003e \u003cli\u003eDedicated GLP key\u003c\/li\u003e \u003cli\u003eGLP data included with logged data\u003c\/li\u003e \u003cli\u003eSimplified data transfer to a PC\u003c\/li\u003e \u003cli\u003eUp to 8 hour battery life when used as a portable device\u003c\/li\u003e \u003cli\u003eInternal clock and date\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e \u003cp\u003e\u003cb\u003eDigital probe input\u003c\/b\u003e - simply connect each probe via the 3.5 mm jack, Digital Smart Electrodes are automatically recognised.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eClear, full text readout\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e- The HI-2600 presents clear, detailed text prompts at the bottom section of the screen.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eTwo operating modes\u003c\/b\u003e - HI-2600 can be used in Standard or Basic Operating Modes (pH and EC only). Standard Mode enables all features while Basic Mode displays a simplified screen and features —ideal for routine measurements.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eData logging\u003c\/b\u003e - The HI-2600 provides ample data storage capacity, allowing you to save up to 1000 log records. Each data set comprehensively includes readings, GLP information, as well as date and time stamps.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eGLP\u003c\/b\u003e - The sensor retains data from the most recent calibration, including date, time, and buffers utilised. When connected to the HI-2600, this GLP information is automatically transferred.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eCAL Check\u003c\/b\u003e - Hanna’s exclusive CAL Check feature analyses the pH electrode’s response in calibration buffers to detect potential issues such as contaminated solutions or dirty electrodes. Upon completing calibration, indicators reflecting the probe’s condition—based on its offset and slope characteristics—are displayed on the measurement screen.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eSensor Check (using HI-11311 and HI-12301 pH probes only)\u003c\/b\u003e - When paired with compatible Hanna electrodes featuring a matching pin, HI-2600 continuously monitors the impedance of the pH measuring electrode, providing real-time alerts in case of glass breakage. During calibration, Sensor Check displays the junction condition, by evaluating the reference junction resistance.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eORP measurement\u003c\/b\u003e - Measure ORP (REDOX) in mV units by using a compatible ORP sensor.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eCapacitive touch keypad\u003c\/b\u003e - HI-2600 features sensitive capacitive touch buttons for accurate keystrokes for navigating menus and screens. Since they are part of the screen, the buttons can never get clogged with sample residue.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eEasy to read LCD\u003c\/b\u003e - HI-2600 features a 5.5” (14 cm) LCD display that you can clearly view from over 5 m (16.4’). The large display, with its wide 130° viewing angle, provides one of the easiest to read LCDs in the industry.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eRechargeable battery\u003c\/b\u003e - The integrated rechargeable battery offers maximum portability with a long 8-hour battery life.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eUSB-C port for charging and data transfer\u003c\/b\u003e - The HI-2600 features a streamlined USB-C port that facilitates charging the integrated rechargeable battery, transferring data to your computer, and exporting files directly to a flash drive.\u003c\/p\u003e \u003ch3\u003e\u003cspan\u003eWhat's included:\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-11310 pH digital electrode\u003c\/li\u003e \u003cli\u003eHI-764026 Electrode holder with the following accessories: base plate with integrated pivot pin; cable holder clip, attached\u003c\/li\u003e \u003cli\u003epH calibration kit: pH 4 buffer solution (2 sachets); pH 7 buffer solution (4 sachets); pH 10 buffer solution sachets (2 sachets)\u003c\/li\u003e \u003cli\u003eElectrode cleaning solution (2 sachets)\u003c\/li\u003e \u003cli\u003eHI-920018 - 1.5m USB-C to USB-C cable\u003c\/li\u003e \u003cli\u003eUSB-C power adapter\u003c\/li\u003e \u003cli\u003eInstrument quality certificate\u003c\/li\u003e \u003cli\u003eProbe \/ electrode quality certificate\u003c\/li\u003e \u003cli\u003eBattery safety insert\u003c\/li\u003e \u003cli\u003eQuick reference guide with QR code for instruction manual download\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cb\u003eWarranty\u003c\/b\u003e - Meter has 2 years. 6 months from date of purchase for electrodes and probes\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eMore accessories to buy separately\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003eElectrodes\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-10530 Triple ceramic, double junction, glass body, refillable pH electrode with conical tip and temperature sensor\u003c\/li\u003e \u003cli\u003eHI-10430 Triple ceramic, double junction, glass body, refillable pH electrode with temperature sensor\u003c\/li\u003e \u003cli\u003eHI-11310 Glass body, double junction, refillable pH\/temperature electrode\u003c\/li\u003e \u003cli\u003eHI-11311 Glass body, double junction, refillable pH\/ temperature electrode with enhanced diagnostics\u003c\/li\u003e \u003cli\u003eHI-12300 Plastic body, double junction, gel filled, non-refillable pH \/ temperature electrode\u003c\/li\u003e \u003cli\u003eHI-12301 Plastic body, double junction, gel filled, non-refillable pH\/temperature electrode with enhanced diagnostics\u003c\/li\u003e \u003cli\u003eHI-36180 Glass body, double junction, refillable ORP\/temperature probe\u003c\/li\u003e \u003cli\u003eHI-763100 Digital EC \/ temperature probe\u003c\/li\u003e \u003cli\u003eHI-764080 Digital DO \/ temperature probe\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eMore solutions to buy separately\u003c\/span\u003e\u003c\/h3\u003e \u003ch3\u003e\u003cspan\u003epH solutions – 500mL (other sizes available)\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-7001L pH 1.68 buffer solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7004L pH 4.01 buffer solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7006L pH 6.86 buffer solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7007L pH 7.01 buffer solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7009L pH 9.18 buffer solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7010L pH 10.01 buffer solution, 500 mL\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eORP solutions\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-7021L ORP test solution, 240 mV @ 25 °C, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7022L ORP test solution, 470 mV @ 25 °C, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7091L Reducing Pretreatment Solution, 500 mL bottle +14 g (set)\u003c\/li\u003e \u003cli\u003eHI-7092L Oxidizing Pretreatment Solution, 500 mL bottle\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003epH electrode maintenance solutions\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-70300L Storage solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-70000P Electrode rinse sachets (25 sachets × 20 mL)\u003c\/li\u003e \u003cli\u003eHI-7061L General cleaning solution, 500 mL\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eConductivity solutions\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-7030L 12880 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7031L 1413 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7033L 84 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7034L 80000 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7035L 111800 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7039L 5000 µS\/cm calibration solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7037L 100% NaCl sea water standard solution, 500 mL\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eDissolved oxygen solutions\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-7040L Zero oxygen solution, 500 mL\u003c\/li\u003e \u003cli\u003eHI-7041S Polarographic dissolved oxygen electrolyte solution, 30 mL\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eOther useful accessories\u003c\/span\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eHI-764026 Electrode holder for HI-2600 family\u003c\/li\u003e \u003cli\u003eHI-764080A\/P Dissolved oxygen spare screw cap membranes for HI-764080 DO probe (5 pcs.)\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e\u003cspan\u003eModels in the series\u003c\/span\u003e\u003c\/h3\u003e \u003cp\u003eHI-2600 pH, EC, DO Benchtop Meter with Data Logging \u003c\/p\u003e \u003cp\u003eHI-2620 pH and ORP Benchtop Meter \u003c\/p\u003e \u003cp\u003eHI-2621 pH and ORP Benchtop Meter with Data Logging\u003c\/p\u003e \u003cp\u003eHI-2630 EC \u0026amp; TDS Benchtop Meter \u003c\/p\u003e \u003cp\u003eHI-2631 EC, TDS and Salinity Benchtop Meter with Data Logging \u003c\/p\u003e \u003cp\u003eHI-2640 Dissolved Oxygen Benchtop Meter \u003c\/p\u003e \u003cp\u003eHI-2641 Dissolved Oxygen Benchtop Meter with Data Logging \u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003epH - using HI-11310 pH electrode\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003ebasic mode: -2.00 to 16.00 pH; standard mode: -2.000 to 16.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003ebasic mode: 0.01 pH; standard mode: 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003ebasic mode: ±0.01 pH; standard mode: ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eBasic Mode: Automatic, up to three points, option to select 5 standard buffers.Standard mode: Automatic, up to five point calibration, 7 standard buffers available and two custom buffers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic, -5.0 to 100.0°C (using integral temperature sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003eUp to 1000* (in Standard Mode) records organised in:• Manual log-on demand, maximum 200 logs• Manual log-on-stability, maximum 200 logs• Interval logging in Standard Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003emV - using HI-11310 pH electrode\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV pH Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eORP – using HI-36180 ORP electrode\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV (±999.9mV); ±1mV (±2000mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic, using integral temperature sensor -5.0 to 100.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003eUp to 1000* (in Standard Mode) records organised in:• Manual log-on demand, maximum 200 logs• Manual log-on-stability, maximum 200 logs• Interval logging in Standard Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eEC - using HI-763100 four-ring conductivity probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 29.99 µS\/cm;30.0 to 299.9 µS\/cm;300 to 2999 µS\/cm;3.00 to 29.99 mS\/cm;30.0 to 200.0 mS\/cm;up to 500.0 mS\/cm,and absolute conductivity (TDS) is the conductivity value without temperature compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm;0.1 µS\/cm;1 µS\/cm;0.01 mS\/cm;0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.5 µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eCell factor calibration; six standards available: 84µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 118.8 mS\/cm, one point offset: 0.00 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic, -5 to 100.0°C; NoTC, can be selected to measure absolute conductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00%\/°C (for EC and TDS only), default value is 1.90%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003eUp to 1000* (400) records organised in:• Manual log-on demand, maximum 200 logs• Manual log-on-stability, maximum 200 logs• Interval logging in Standard Mode, maximum 600 logs (100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTDS - using HI-763100 four-ring conductivity probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.99 mg\/L (ppm);15.0 to 149.9 mg\/L (ppm);150 to 1499 mg\/L (ppm);1.50 to 14.99 g\/L;15.0 to 100.0 g\/L;up to 400.0 g\/L absolute TDS using 0.80 conversion factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm);0.1 mg\/L (ppm);1 (ppm);0.01 g\/L;0.1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.03 ppm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor in Standard Mode\u003c\/td\u003e\n\u003ctd\u003e0.40 to 0.80 (default value is 0.50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eSalinity - using HI-763100 four-ring conductivity probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0 % NaCl; 2.00 to 42.00 PSU; 0.00 to 80.00 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 % NaCl; 0.01 PSU; 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration % NaCl only\u003c\/td\u003e\n\u003ctd\u003eone point with HI-7037 standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDissolved Oxygen - using HI-764080 DO Probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 PPM (mg\/L); 0.0 to 300.0% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm (mg\/L); 0.1% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading (± 1 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eone or two point at 0% (HI-7040L solution) and 100% (water-saturated air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic 450.0 to 850.0 mmHg – (0.1 mmHg resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L – (1g\/L resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 records organised in:• Manual log-on-demand, maximum 200 logs• Manual log-on-stability, maximum 200 logs• Interval logging in Standard Mode, maximum 600 logs (100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAdditional Specifications\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Interface\u003c\/td\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Interface\u003c\/td\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eUSB Type C (5 VDC; 500mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50˚C; Maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003eHI-2600 pH\/EC\/DO benchtop meter includes HI-11310 glass body refillable pH electrode, pH 4 buffer solution sachets (2), pH 7 buffer solution sachets (4), pH 10 buffer solution sachets (2), electrode cleaning solution sachets (2), electrode holder, 1.5 m USB-C to C USB-C cable. All HI-2600 series compatible pH, EC and DO digital probes are interchangeable with HI-2600 and can be ordered separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640057962869,"sku":"HI-2600-02","price":470.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-2600-ph-ec-and-do-benchmeter.jpg?v=1791579970"},{"product_id":"hanna-instruments-hi-6222-ph-orp-ise-multiparameter-modular-benchtop-meter","title":"Hanna Instruments HI-6222 pH\/ORP\/ISE Multiparameter Modular Benchtop Meter","description":"\u003ch3\u003eHI-6222 pH\/ORP\/ISE Multiparameter Modular Benchtop System\u003c\/h3\u003e \u003cp\u003eThe HI-6222 Kit for the HI-6000 includes the HI-6000 modular multiparameter meter system and two of the HI-6000-2 pH\/ISE modules. Also included is the \u003cspan\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e\u003c\/span\u003e and \u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e, providing everything you need for accurate, reliable measurement out of the box. A calibration solution starter set for pH is packaged with this kit.\u003c\/p\u003e \u003cp\u003eHI-6000 is a fully flexible measurement platform that can be customised according to the user’s application needs. Designed and developed using the latest generation technologies, it gives complete control over measurements.\u003c\/p\u003e \u003cp\u003eSix different pre-built kits are available for the HI-6000 multimeter, including the modules and electrodes required for laboratory-grade measurement:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6222 pH\/ORP\/ISE Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6522 pH\/ORP\/ISE + EC Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6542 pH\/ORP\/ISE + Optical DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6542\/P pH\/ORP\/ISE + Polarographic DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6553 pH\/ORP\/ISE + EC + Optical DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003ciframe width=\"1903\" height=\"750\" src=\"https:\/\/www.youtube.com\/embed\/tFJ33akvrmE\" title=\"Go Modular: The HI-6000 Multiparameter Modular System from Hanna Instruments\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e \u003ch3\u003eAccurate \u0026amp; Reliable\u003c\/h3\u003e \u003cp\u003eTogether with appropriate electrodes, the meter provides highly accurate and reliable measurement for all laboratories. Up to three measurement channels can be viewed simultaneously. Views can be mixed and matched. Data can be shown in basic or in full detail, in a table or plotted as a graph.\u003c\/p\u003e \u003cp\u003eThe HI-6000 Series allows for up to 5-point calibration for pH, ISE and Conductivity for optimum results.\u003c\/p\u003e \u003cul\u003e \u003cli\u003epH calibration up to 5 points with 8 stored standard buffers and 5 custom buffers\u003c\/li\u003e \u003cli\u003eISE calibration up to 5 points with 5 stored standards and 5 custom buffers\u003c\/li\u003e \u003cli\u003eConductivity calibration up to 5 points with 6 stored standards and 1 user standard\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eGo digital\u003c\/h3\u003e \u003cp\u003eThe HI-6000 multimeter helps you avoid errors caused by manual transcription of results, thanks to simple and flexible data management. The instrument can store up to 1,000,000 data points for each user.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eData can be shared via Wi-Fi, Ethernet, email, web server, USB flash drive or PC\u003c\/li\u003e \u003cli\u003eNo software is required\u003c\/li\u003e \u003cli\u003eConveniently connect a keyboard, a barcode scanner, a printer or two stirrers to improve your workflow\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eSeamless simplicity\u003c\/h3\u003e \u003cp\u003eThe HI-6000 multiparameter meter features a user-friendly design for effortless control and seamless simplicity. The benchtop unit has a large capacitive touch screen with multi-touch support. The help menu supports you with an overview of the main functionalities through text and video tutorials for quick assistance.\u003c\/p\u003e \u003ch3\u003eUser-friendly interface\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eUser-friendly icons and symbols enable easy navigation and interpretation of instrument functions\u003c\/li\u003e \u003cli\u003eChoice of five different display modes: Standard, Simple GLP with calibration information, Full GLP with electrode status and calibration point details, Interactive graph updated in real-time,\u003c\/li\u003e \u003cli\u003eTabulated data with date, time and notes\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e10 user profiles\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eFor direct access to daily analyses, users can save their procedures in profiles grouping all their method configuration data.\u003c\/li\u003e \u003cli\u003eEach user profile is password-protected\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eOn-board help and video tutorials\u003c\/h3\u003e \u003cp\u003eThe help menu supports users with a brief overview of the system’s main functionalities through text and video tutorials.\u003c\/p\u003e \u003ch3\u003eCertified accuracy\u003c\/h3\u003e \u003cp\u003eOur technical department offers a comprehensive certification and periodic calibration service, ensuring that your measuring instruments are always reliable and comply with the required standards. Each instrument, module, and probe is provided with a quality certificate, guaranteeing their high performance.\u003c\/p\u003e \u003cp\u003eRegular maintenance of instruments is essential for those operating quality management systems, as it helps maintain precision and reliability in measurements, aspects that can be verified during audits.\u003c\/p\u003e \u003ch3\u003eOngoing support\u003c\/h3\u003e \u003cp\u003eOur technical team is here to help you with:\u003c\/p\u003e \u003cul\u003e \u003cli\u003ePhone support\u003c\/li\u003e \u003cli\u003eQuick assistance\u003c\/li\u003e \u003cli\u003eAdvice on choosing the right electrodes for your application\u003c\/li\u003e \u003cli\u003eCalibration services\u003c\/li\u003e \u003cli\u003eRepairs on our premises\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135401.png\" alt=\"a close-up image of the HI-6000 modular multiparameter system modules\" width=\"1000\" height=\"393\"\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eAbout the HI-6000 modules\u003c\/h2\u003e \u003cp\u003eThe HI-6222 pH\/ORP\/ISE kit includes two HI-6000-2 pH\/ISE modules suitable for commercial and research laboratory measurement of key parameters. \u003c\/p\u003e \u003cp\u003eThe Hanna HI-6000-2 module for the HI-6000 Advanced Multiparameter Meter provides an accurate and repeatable solution for measuring pH, ORP and ISE. This module can be combined with other modules simultaneously in the HI-6000 system with three slots available, allowing for the measurement of a wide range of samples at once. \u003c\/p\u003e \u003cp\u003eModules available for the HI-6000 include: \u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-6000-1 module for pH\/ORP\u003c\/li\u003e \u003cli\u003eHI-6000-2 module for pH\/ORP\/ISE\u003c\/li\u003e \u003cli\u003eHI-6000-3 module for EC\u003c\/li\u003e \u003cli\u003eHI-6000-4 module for DO\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eModules can be ordered individually, allowing you to further expand the functionality of the HI-6000 beyond your kit at any time.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135207.png\" alt=\"a close-up image of the HI-6000 multiparameter modular system featuring three displays for different parameters\" width=\"1000\" height=\"447\"\u003e\u003c\/p\u003e \u003ch2\u003eHI-6000 Features\u003c\/h2\u003e \u003ch3\u003ePlug-and-play modular design\u003c\/h3\u003e \u003cp\u003eThe HI-6000 provides full flexibility to create the multiparameter meter that suits your requirements. ‘Plug-and-play’ modules can be easily swapped to configure the HI-6000 to suit your workflow and volume of testing, allowing this benchtop multimeter to adapt and evolve for accurate, repeatable measurement over a range of parameters.\u003c\/p\u003e \u003ch3\u003eComprehensive parameter range\u003c\/h3\u003e \u003cp\u003eThe HI-6000 modular units cover a comprehensive selection of the most common parameters for laboratories when combined with suitable Hanna Instruments electrodes and probes. Measure pH, ORP, ISE, DO and EC with exceptional accuracy across a wide range, including niche areas, industrial purposes and environmental applications.\u003c\/p\u003e \u003cp\u003eThe HI-6000-2 ISE, pH and ORP module introduces a new parameter into the HI-6000 range of laboratory-grade meters. This module is compatible with Hanna’s comprehensive range of ISE electrodes for the measurement of niche parameters in samples according to industry requirements.\u003c\/p\u003e \u003cp\u003eThe EC module HI-6000-3 in combination with the HI-6000 system provides an ideal solution for the three stages of USP \u0026lt;645\u0026gt;, with all three stages programmed directly into the meter ready to use out of the box.\u003c\/p\u003e \u003ch3\u003eCompatible with Hanna laboratory-grade probes and electrodes\u003c\/h3\u003e \u003cp\u003eCombine the HI-6000 modules with Hanna’s highly accurate probes and electrodes for reliability in testing. Each module has a recommended probe configuration for accurate testing. The HI-2000-2 pH, ISE and ORP modules are compatible with Hanna’s range of ion-selective electrodes, allowing you to tailor your HI-6000 multiparameter meter to your specific requirements for measurement.\u003c\/p\u003e \u003ch3\u003eModern, functional design\u003c\/h3\u003e \u003cp\u003eThe HI-6000 series is designed to be an ideal solution for modern laboratories. A streamlined design with a large capacitive touch screen that works even with gloves and a small footprint allows this advanced meter to take up less space while providing all the functionality of a multiparameter meter with swappable modules. The electrode arms can be placed on both or either side for additional flexibility in the lab.\u003c\/p\u003e \u003ch3\u003eExceptional accuracy across all parameters\u003c\/h3\u003e \u003cp\u003eThe HI-6000 is a highly accurate, laboratory-grade multiparameter meter. In combination with Hanna electrodes and probes, each module of the HI-6000 provides exceptionally accurate, repeatable measurements from testing. In-built features such as galvanic isolation ensure the same degree of accuracy without interference across a wide range of different samples and applications.\u003c\/p\u003e \u003ch3\u003eComplete accessibility\u003c\/h3\u003e \u003cp\u003eAccess data anywhere with the HI-6000, with WiFi and ethernet capability that allows measurements to be sent remotely to offices, other labs or directly to clients as required. The HI-6000 series can also export .csv universal data via a USB stick or to a connected printer or PC. \u003c\/p\u003e \u003ch3\u003eUser-friendly interface\u003c\/h3\u003e \u003cp\u003eHI-6000 meters are designed to be easy to follow, with user-friendly menus and an intuitive interface to reduce the time between setup and measurement. The settings menu includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eNetwork\u003c\/li\u003e \u003cli\u003eConnect and Print\u003c\/li\u003e \u003cli\u003eSystem\u003c\/li\u003e \u003cli\u003eCustom Users\u003c\/li\u003e \u003cli\u003eUser Account Management\u003c\/li\u003e \u003cli\u003eInfo Screen\u003c\/li\u003e \u003cli\u003eLog Recall\u003c\/li\u003e \u003cli\u003eLog History and Sharing\u003c\/li\u003e \u003cli\u003eLog Detail\u003c\/li\u003e \u003cli\u003eOn-Board Help\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eFive views, three measurements\u003c\/h3\u003e \u003cp\u003eThe HI-6000 can measure up to three samples simultaneously, splitting the screen in half or into thirds depending on your measurement requirements. Five individual views are available on-screen:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eBasic View:\u003c\/strong\u003e A simplified display of the measurement unit, measured value and temperature source.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSimple GLP View:\u003c\/strong\u003e A more complex display with the last calibration date and time, Offset value, average slope and electrode condition.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFull GLP View:\u003c\/strong\u003e A complete display including electrode symbol and used buffers tray in addition to all of the above.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGraph View:\u003c\/strong\u003e A live, plotted graph of the measured value\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eTabulated View:\u003c\/strong\u003e A classic table-style display featuring all measured values in chronological order with date, time and notes.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eUp to one million data points\u003c\/h3\u003e \u003cp\u003eThe HI-6000 has the capacity for up to 1 million individual data points, complete with time and date stamps for practical organisation and management. This data is accessible via WiFi and ethernet to FTP and email as well as over a USB stick or direct connection to a laptop, PC or printer.\u003c\/p\u003e \u003ch3\u003eComplete alarm system\u003c\/h3\u003e \u003cp\u003eBoth audible and visual alarms are available for the HI-6000, allowing you to be notified of any measurements that are outside of the correct ranges. Customise the ranges directly to set audible, visual or both alarms that activate outside of the defined limit, saving time in identifying potential calibration or sample problems.\u003c\/p\u003e \u003ch3\u003eUSB C and USB A functionality\u003c\/h3\u003e \u003cp\u003eBoth USB A and USB C connections are included with the HI-6000 series, allowing you to easily transfer data and connect peripherals such as a keyboard. Data from measurements are exported in a universal .csv format, requiring no additional software to access logged data on any laptop or PC.\u003c\/p\u003e \u003ch3\u003eVideo and text tutorial system\u003c\/h3\u003e \u003cp\u003eAn in-built tutorial system available through the HELP button makes the learning curve for the HI-6000 series as minimal as possible. Both text instructions and video tutorials are available, matching your preferred learning style for the setup of the HI-6000.\u003c\/p\u003e \u003ch3\u003eCreate and manage users\u003c\/h3\u003e \u003cp\u003eA complete user management system allows the HI-6000 multiparameter lab meter to be customised for individual students and technicians. Both administrator and standard accounts can be created, with the administrator role having full management of standard accounts via the Account Management Screen to assign or remove permissions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135504.png\" alt=\"an image of the Hanna Instruments HI-6000 modular multiparameter meter\" width=\"1000\" height=\"461\"\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eFAQs\u003c\/h2\u003e \u003ch3\u003eWhat is included with this meter kit?\u003c\/h3\u003e \u003cp\u003eThis kit for the HI-6000 laboratory grade meter includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-6000 modular multiparameter meter system\u003c\/li\u003e \u003cli\u003e2x HI-6000-2 pH\/ISE modules\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003eA calibration solution starter set for pH\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eHow do you swap modules?\u003c\/h3\u003e \u003cp\u003eSwapping modules with the HI-6000 multimeter is easy, with a simple latch and screw feature that holds the module firmly in place while allowing for fast and easy module swapping. Three modules can be used at any time with the HI-6000 benchtop meter, with split-screen functionality to view all sample measurements at the same time.\u003c\/p\u003e \u003ch3\u003eCan I book a demonstration of the HI-6000 modular system?\u003c\/h3\u003e \u003ch3\u003eIs the HI-6000 suitable for use in a laboratory?\u003c\/h3\u003e \u003cp\u003eThe HI-6000 modular meter is specifically designed for use in a laboratory environment for applications in various industries and businesses as well as for labs that provide outsourced services to their clients. This lab-grade multiparameter meter provides exceptional accuracy across all parameters, including dissolved oxygen, conductivity, pH, ORP and ISE.\u003c\/p\u003e \u003ch3\u003eWhat are the key features of the HI-6000?\u003c\/h3\u003e \u003cp\u003eSome of the key features of the Hanna HI-6000 include:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eModular design with four different modules\u003c\/li\u003e \u003cli\u003e‘Plug-and-play’ modular functionality\u003c\/li\u003e \u003cli\u003eCompatible with a range of Hanna electrodes and probes\u003c\/li\u003e \u003cli\u003eSplit screen for measurements\u003c\/li\u003e \u003cli\u003eWiFi and ethernet connectivity\u003c\/li\u003e \u003cli\u003eUser-friendly interface\u003c\/li\u003e \u003cli\u003eFlexible, compact design\u003c\/li\u003e \u003cli\u003eExceptional accuracy and repeatability\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCan I get training on the HI-6000?\u003c\/h3\u003e \u003ch3\u003eWhat industries is the HI-6000 suitable for?\u003c\/h3\u003e \u003cp\u003eThe modular nature of the HI-6000 benchtop lab meter and the six individual kits available allow this instrument to be customised to the requirements of a wide range of industries and applications. \u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-6222-02 pH\/ORP\/ISE Kit\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eISE\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1 x 10-6 to 9.99 x 1010 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1; 0.1; 0.01; 0.001 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV offset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard buffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOffset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable; Isopotential point: -2.000 to 20.000pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640069300597,"sku":"HI-6222-02","price":1182.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-6222-02-ph-orp-ise-multiparameter-modular-benchtop-system.jpg?v=1791580385"},{"product_id":"hanna-instruments-hi-6542-ph-orp-ise-optical-do-multiparameter-modular-benchtop-meter","title":"Hanna Instruments HI-6542 pH\/ORP\/ISE + Optical DO Multiparameter Modular Benchtop Meter","description":"\u003ch3\u003eHI-6542 pH\/ORP\/ISE + Optical DO Multiparameter Modular Benchtop System\u003c\/h3\u003e \u003cp\u003eThe HI-6542 Kit for the HI-6000 includes the HI-6000 modular multiparameter meter system, a HI-6000-2 pH\/ISE module and a HI-6000-4 dissolved oxygen module. Also included is the \u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e, \u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e and \u003cspan\u003e\u003cspan\u003eHI-7641133 optical DO probe with a HI-764113-1 Smart Cap\u003c\/span\u003e\u003c\/span\u003e. This kit includes everything needed to accurately measure DO and pH out-of-the-box, including a calibration solution starter set for both pH and DO.\u003c\/p\u003e \u003cp\u003eHI-6000 is a fully flexible measurement platform that can be customised according to the user’s application needs. Designed and developed using the latest generation technologies, it gives complete control over measurements.\u003c\/p\u003e \u003cp\u003eSix different pre-built kits are available for the HI-6000 multimeter, including the modules and electrodes required for laboratory-grade measurement:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6222 pH\/ORP\/ISE Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6522 pH\/ORP\/ISE + EC Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6542 pH\/ORP\/ISE + Optical DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6542\/P pH\/ORP\/ISE + Polarographic DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6553 pH\/ORP\/ISE + EC + Optical DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003ciframe width=\"1903\" height=\"750\" src=\"https:\/\/www.youtube.com\/embed\/tFJ33akvrmE\" title=\"Go Modular: The HI-6000 Multiparameter Modular System from Hanna Instruments\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e \u003ch3\u003eAccurate \u0026amp; Reliable\u003c\/h3\u003e \u003cp\u003eTogether with appropriate electrodes, the meter provides highly accurate and reliable measurement for all laboratories. Up to three measurement channels can be viewed simultaneously. Views can be mixed and matched. Data can be shown in basic or in full detail, in a table or plotted as a graph.\u003c\/p\u003e \u003cp\u003eThe HI-6000 Series allows for up to 5-point calibration for pH, ISE and Conductivity for optimum results.\u003c\/p\u003e \u003cul\u003e \u003cli\u003epH calibration up to 5 points with 8 stored standard buffers and 5 custom buffers\u003c\/li\u003e \u003cli\u003eISE calibration up to 5 points with 5 stored standards and 5 custom buffers\u003c\/li\u003e \u003cli\u003eConductivity calibration up to 5 points with 6 stored standards and 1 user standard\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eGo digital\u003c\/h3\u003e \u003cp\u003eThe HI-6000 multimeter helps you avoid errors caused by manual transcription of results, thanks to simple and flexible data management. The instrument can store up to 1,000,000 data points for each user.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eData can be shared via Wi-Fi, Ethernet, email, web server, USB flash drive or PC\u003c\/li\u003e \u003cli\u003eNo software is required\u003c\/li\u003e \u003cli\u003eConveniently connect a keyboard, a barcode scanner, a printer or two stirrers to improve your workflow\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eSeamless simplicity\u003c\/h3\u003e \u003cp\u003eThe HI-6000 multiparameter meter features a user-friendly design for effortless control and seamless simplicity. The benchtop unit has a large capacitive touch screen with multi-touch support. The help menu supports you with an overview of the main functionalities through text and video tutorials for quick assistance.\u003c\/p\u003e \u003ch3\u003eUser-friendly interface\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eUser-friendly icons and symbols enable easy navigation and interpretation of instrument functions\u003c\/li\u003e \u003cli\u003eChoice of five different display modes: Standard, Simple GLP with calibration information, Full GLP with electrode status and calibration point details, Interactive graph updated in real-time,\u003c\/li\u003e \u003cli\u003eTabulated data with date, time and notes\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e10 user profiles\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eFor direct access to daily analyses, users can save their procedures in profiles grouping all their method configuration data.\u003c\/li\u003e \u003cli\u003eEach user profile is password-protected\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eOn-board help and video tutorials\u003c\/h3\u003e \u003cp\u003eThe help menu supports users with a brief overview of the system’s main functionalities through text and video tutorials.\u003c\/p\u003e \u003ch3\u003eCertified accuracy\u003c\/h3\u003e \u003cp\u003eOur technical department offers a comprehensive certification and periodic calibration service, ensuring that your measuring instruments are always reliable and comply with the required standards. Each instrument, module, and probe is provided with a quality certificate, guaranteeing their high performance.\u003c\/p\u003e \u003cp\u003eRegular maintenance of instruments is essential for those operating quality management systems, as it helps maintain precision and reliability in measurements, aspects that can be verified during audits.\u003c\/p\u003e \u003ch3\u003eOngoing support\u003c\/h3\u003e \u003cp\u003eOur technical team is here to help you with:\u003c\/p\u003e \u003cul\u003e \u003cli\u003ePhone support\u003c\/li\u003e \u003cli\u003eQuick assistance\u003c\/li\u003e \u003cli\u003eAdvice on choosing the right electrodes for your application\u003c\/li\u003e \u003cli\u003eCalibration services\u003c\/li\u003e \u003cli\u003eRepairs on our premises\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135401.png\" alt=\"a close-up image of the HI-6000 modular multiparameter system modules\" width=\"1000\" height=\"393\"\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eAbout the HI-6000 modules\u003c\/h2\u003e \u003cp\u003eThe HI-6222 pH\/ORP\/ISE kit includes the HI-6000-2 pH\/ISE module and HI-6000-4 DO module, covering a wide range of key measurement parameters for laboratories. \u003c\/p\u003e \u003cp\u003eThe Hanna HI-6000-2 module for the HI-6000 Advanced Multiparameter Meter provides a repeatable, accurate solution for measuring pH, ORP and ISE. This module can be combined with up to two other modules at once in the HI-6000 system, allowing for the measurement of a wide range of samples simultaneously. \u003c\/p\u003e \u003cp\u003eThe HI-6000-4 module for the HI-6000 Benchtop Advance Benchtop Multiparameter Meter offers a reliable, accurate and repeatable solution to measure dissolved oxygen within fresh and saltwater samples. This module supports numerous dissolved oxygen applications, such as oxygen uptake rate, specific oxygen uptake rate and biological oxygen demand.\u003c\/p\u003e \u003cp\u003eModules available for the HI-6000 include: \u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-6000-1 module for pH\/ORP\u003c\/li\u003e \u003cli\u003eHI-6000-2 module for pH\/ORP\/ISE\u003c\/li\u003e \u003cli\u003eHI-6000-3 module for EC\u003c\/li\u003e \u003cli\u003eHI-6000-4 module for DO\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eModules can be ordered individually, allowing you to further expand the functionality of the HI-6000 beyond your kit at any time.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135207.png\" alt=\"a close-up image of the HI-6000 multiparameter modular system featuring three displays for different parameters\" width=\"1000\" height=\"447\"\u003e\u003c\/p\u003e \u003ch2\u003eHI-6000 Features\u003c\/h2\u003e \u003ch3\u003ePlug-and-play modular design\u003c\/h3\u003e \u003cp\u003eThe HI-6000 provides full flexibility to create the multiparameter meter that suits your requirements. ‘Plug-and-play’ modules can be easily swapped to configure the HI-6000 to suit your workflow and volume of testing, allowing this benchtop multimeter to adapt and evolve for accurate, repeatable measurement over a range of parameters.\u003c\/p\u003e \u003ch3\u003eComprehensive parameter range\u003c\/h3\u003e \u003cp\u003eThe HI-6000 modular units cover a comprehensive selection of the most common parameters for laboratories when combined with suitable Hanna Instruments electrodes and probes. Measure pH, ORP, ISE, DO and EC with exceptional accuracy across a wide range, including niche areas, industrial purposes and environmental applications.\u003c\/p\u003e \u003cp\u003eThe HI-6000-2 ISE, pH and ORP module introduces a new parameter into the HI-6000 range of laboratory-grade meters. This module is compatible with Hanna’s comprehensive range of ISE electrodes for the measurement of niche parameters in samples according to industry requirements.\u003c\/p\u003e \u003cp\u003eThe EC module HI-6000-3 in combination with the HI-6000 system provides an ideal solution for the three stages of USP \u0026lt;645\u0026gt;, with all three stages programmed directly into the meter ready to use out of the box.\u003c\/p\u003e \u003ch3\u003eCompatible with Hanna laboratory-grade probes and electrodes\u003c\/h3\u003e \u003cp\u003eCombine the HI-6000 modules with Hanna’s highly accurate probes and electrodes for reliability in testing. Each module has a recommended probe configuration for accurate testing. The HI-2000-2 pH, ISE and ORP modules are compatible with Hanna’s range of ion-selective electrodes, allowing you to tailor your HI-6000 multiparameter meter to your specific requirements for measurement.\u003c\/p\u003e \u003ch3\u003eModern, functional design\u003c\/h3\u003e \u003cp\u003eThe HI-6000 series is designed to be an ideal solution for modern laboratories. A streamlined design with a large capacitive touch screen that works even with gloves and a small footprint allows this advanced meter to take up less space while providing all the functionality of a multiparameter meter with swappable modules. The electrode arms can be placed on both or either side for additional flexibility in the lab.\u003c\/p\u003e \u003ch3\u003eExceptional accuracy across all parameters\u003c\/h3\u003e \u003cp\u003eThe HI-6000 is a highly accurate, laboratory-grade multiparameter meter. In combination with Hanna electrodes and probes, each module of the HI-6000 provides exceptionally accurate, repeatable measurements from testing. In-built features such as galvanic isolation ensure the same degree of accuracy without interference across a wide range of different samples and applications.\u003c\/p\u003e \u003ch3\u003eComplete accessibility\u003c\/h3\u003e \u003cp\u003eAccess data anywhere with the HI-6000, with WiFi and ethernet capability that allows measurements to be sent remotely to offices, other labs or directly to clients as required. The HI-6000 series can also export .csv universal data via a USB stick or to a connected printer or PC. \u003c\/p\u003e \u003ch3\u003eUser-friendly interface\u003c\/h3\u003e \u003cp\u003eHI-6000 meters are designed to be easy to follow, with user-friendly menus and an intuitive interface to reduce the time between setup and measurement. The settings menu includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eNetwork\u003c\/li\u003e \u003cli\u003eConnect and Print\u003c\/li\u003e \u003cli\u003eSystem\u003c\/li\u003e \u003cli\u003eCustom Users\u003c\/li\u003e \u003cli\u003eUser Account Management\u003c\/li\u003e \u003cli\u003eInfo Screen\u003c\/li\u003e \u003cli\u003eLog Recall\u003c\/li\u003e \u003cli\u003eLog History and Sharing\u003c\/li\u003e \u003cli\u003eLog Detail\u003c\/li\u003e \u003cli\u003eOn-Board Help\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eFive views, three measurements\u003c\/h3\u003e \u003cp\u003eThe HI-6000 can measure up to three samples simultaneously, splitting the screen in half or into thirds depending on your measurement requirements. Five individual views are available on-screen:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eBasic View:\u003c\/strong\u003e A simplified display of the measurement unit, measured value and temperature source.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSimple GLP View:\u003c\/strong\u003e A more complex display with the last calibration date and time, Offset value, average slope and electrode condition.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFull GLP View:\u003c\/strong\u003e A complete display including electrode symbol and used buffers tray in addition to all of the above.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGraph View:\u003c\/strong\u003e A live, plotted graph of the measured value\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eTabulated View:\u003c\/strong\u003e A classic table-style display featuring all measured values in chronological order with date, time and notes.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eUp to one million data points\u003c\/h3\u003e \u003cp\u003eThe HI-6000 has the capacity for up to 1 million individual data points, complete with time and date stamps for practical organisation and management. This data is accessible via WiFi and ethernet to FTP and email as well as over a USB stick or direct connection to a laptop, PC or printer.\u003c\/p\u003e \u003ch3\u003eComplete alarm system\u003c\/h3\u003e \u003cp\u003eBoth audible and visual alarms are available for the HI-6000, allowing you to be notified of any measurements that are outside of the correct ranges. Customise the ranges directly to set audible, visual or both alarms that activate outside of the defined limit, saving time in identifying potential calibration or sample problems.\u003c\/p\u003e \u003ch3\u003eUSB C and USB A functionality\u003c\/h3\u003e \u003cp\u003eBoth USB A and USB C connections are included with the HI-6000 series, allowing you to easily transfer data and connect peripherals such as a keyboard. Data from measurements are exported in a universal .csv format, requiring no additional software to access logged data on any laptop or PC.\u003c\/p\u003e \u003ch3\u003eVideo and text tutorial system\u003c\/h3\u003e \u003cp\u003eAn in-built tutorial system available through the HELP button makes the learning curve for the HI-6000 series as minimal as possible. Both text instructions and video tutorials are available, matching your preferred learning style for the setup of the HI-6000.\u003c\/p\u003e \u003ch3\u003eCreate and manage users\u003c\/h3\u003e \u003cp\u003eA complete user management system allows the HI-6000 multiparameter lab meter to be customised for individual students and technicians. Both administrator and standard accounts can be created, with the administrator role having full management of standard accounts via the Account Management Screen to assign or remove permissions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135504.png\" alt=\"an image of the Hanna Instruments HI-6000 modular multiparameter meter\" width=\"1000\" height=\"461\"\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eFAQs\u003c\/h2\u003e \u003ch3\u003eWhat is included with this meter kit?\u003c\/h3\u003e \u003cp\u003eThis kit for the HI-6000 laboratory grade meter includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-6000 modular multiparameter meter system\u003c\/li\u003e \u003cli\u003eHI-6000-2 pH\/ISE module\u003c\/li\u003e \u003cli\u003eHI-6000-4 DO module\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-7641133 optical DO probe with HI-764113-1 Smart Cap\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003eA calibration solution starter kit for pH and DO\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eHow do you swap modules?\u003c\/h3\u003e \u003cp\u003eSwapping modules with the HI-6000 multimeter is easy, with a simple latch and screw feature that holds the module firmly in place while allowing for fast and easy module swapping. Three modules can be used at any time with the HI-6000 benchtop meter, with split-screen functionality to view all sample measurements at the same time.\u003c\/p\u003e \u003ch3\u003eCan I book a demonstration of the HI-6000 modular system?\u003c\/h3\u003e \u003ch3\u003eIs the HI-6000 suitable for use in a laboratory?\u003c\/h3\u003e \u003cp\u003eThe HI-6000 modular meter is specifically designed for use in a laboratory environment for applications in various industries and businesses as well as for labs that provide outsourced services to their clients. This lab-grade multiparameter meter provides exceptional accuracy across all parameters, including dissolved oxygen, conductivity, pH, ORP and ISE.\u003c\/p\u003e \u003ch3\u003eWhat are the key features of the HI-6000?\u003c\/h3\u003e \u003cp\u003eSome of the key features of the Hanna HI-6000 include:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eModular design with four different modules\u003c\/li\u003e \u003cli\u003e‘Plug-and-play’ modular functionality\u003c\/li\u003e \u003cli\u003eCompatible with a range of Hanna electrodes and probes\u003c\/li\u003e \u003cli\u003eSplit screen for measurements\u003c\/li\u003e \u003cli\u003eWiFi and ethernet connectivity\u003c\/li\u003e \u003cli\u003eUser-friendly interface\u003c\/li\u003e \u003cli\u003eFlexible, compact design\u003c\/li\u003e \u003cli\u003eExceptional accuracy and repeatability\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCan I get training on the HI-6000?\u003c\/h3\u003e \u003ch3\u003eWhat industries is the HI-6000 suitable for?\u003c\/h3\u003e \u003cp\u003eThe modular nature of the HI-6000 benchtop lab meter and the six individual kits available allow this instrument to be customised to the requirements of a wide range of industries and applications. \u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-6542-02 pH\/ORP\/ISE + Optical (opdo) DO Kit\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eISE\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1 x 10-6 to 9.99 x 1010 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1; 0.1; 0.01; 0.001 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV offset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard buffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOffset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable; Isopotential point: -2.000 to 20.000pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDissolved Oxygen\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eRefer to individual specifications for probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-7641133 DO Probe Specification\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Body Material\u003c\/td\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart Cap™ material\u003c\/td\u003e\n\u003ctd\u003ePolypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable jacket material\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprobe guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd\u003eThermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd\u003e20m (29 PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Dimensions with guard\u003c\/td\u003e\n\u003ctd\u003e174 x 25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e45 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprobe ingress protection rating\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor type\u003c\/td\u003e\n\u003ctd\u003eOptical; luminescence quenching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-764833 Polarographic probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5 % of reading ±1, least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eBarometric Pressure\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mmHg; 600 to 1133 mBar; 60 to 113.32 kPa; 17.72 to 33.46 inHg; 8.702 to 16.436 psi; 0.592 to 1.1184 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mmHg; 0.1 mBar; 0.01 kPa; 0.01 inHg; 0.001 psi; 0.0001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mmHg within ±15 % from the calibration point ±3 mmHg ±1 least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eRefer to specification of probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDO Calibration\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoints\u003c\/td\u003e\n\u003ctd\u003eOne or two points at 100.0% (8.26 mg\/L) and 0.0% (0.00 mg\/L) automatic. Manual using a value entered by the user in % saturation, mg\/L or ppm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point, configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003eManual; 0.00 to 45.00 PSU or ppt 0.0 to 130.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640069529973,"sku":"HI-6542-02","price":1578.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-6542-02-ph-orp-ise-optical-do-multiparameter-modular-benchtop-system_f733060a-3a13-42af-b968-bdd10ea9e86d.jpg?v=1791580397"},{"product_id":"hanna-instruments-hi-6542-p-ph-orp-ise-polarographic-do-multiparameter-modular-benchtop-meter","title":"Hanna Instruments HI-6542\/P pH\/ORP\/ISE + Polarographic DO Multiparameter Modular Benchtop Meter","description":"\u003ch3\u003eHI-6542\/P pH\/ORP\/ISE + Polarographic DO Multiparameter Modular Benchtop System\u003c\/h3\u003e \u003cp\u003eThe HI-6542\/P Kit for the HI-6000 includes the HI-6000 modular multiparameter meter system, a HI-6000-2 pH\/ISE module and a HI-6000-4 dissolved oxygen module. Also included is the \u003cspan\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e, \u003c\/span\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e and \u003cspan\u003e\u003cspan\u003eHI-764833 polarographic DO probe\u003c\/span\u003e\u003c\/span\u003e. This kit includes everything needed to accurately measure DO and pH out-of-the-box, including a calibration solution starter set for both pH and DO.\u003c\/p\u003e \u003cp\u003eHI-6000 is a fully flexible measurement platform that can be customised according to the user’s application needs. Designed and developed using the latest generation technologies, it gives complete control over measurements.\u003c\/p\u003e \u003cp\u003eSix different pre-built kits are available for the HI-6000 multimeter, including the modules and electrodes required for laboratory-grade measurement:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6222 pH\/ORP\/ISE Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6522 pH\/ORP\/ISE + EC Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6542 pH\/ORP\/ISE + Optical DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6542\/P pH\/ORP\/ISE + Polarographic DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6553 pH\/ORP\/ISE + EC + Optical DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003ciframe width=\"1903\" height=\"750\" src=\"https:\/\/www.youtube.com\/embed\/tFJ33akvrmE\" title=\"Go Modular: The HI-6000 Multiparameter Modular System from Hanna Instruments\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e \u003ch3\u003eAccurate \u0026amp; Reliable\u003c\/h3\u003e \u003cp\u003eTogether with appropriate electrodes, the meter provides highly accurate and reliable measurement for all laboratories. Up to three measurement channels can be viewed simultaneously. Views can be mixed and matched. Data can be shown in basic or in full detail, in a table or plotted as a graph.\u003c\/p\u003e \u003cp\u003eThe HI-6000 Series allows for up to 5-point calibration for pH, ISE and Conductivity for optimum results.\u003c\/p\u003e \u003cul\u003e \u003cli\u003epH calibration up to 5 points with 8 stored standard buffers and 5 custom buffers\u003c\/li\u003e \u003cli\u003eISE calibration up to 5 points with 5 stored standards and 5 custom buffers\u003c\/li\u003e \u003cli\u003eConductivity calibration up to 5 points with 6 stored standards and 1 user standard\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eGo digital\u003c\/h3\u003e \u003cp\u003eThe HI-6000 multimeter helps you avoid errors caused by manual transcription of results, thanks to simple and flexible data management. The instrument can store up to 1,000,000 data points for each user.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eData can be shared via Wi-Fi, Ethernet, email, web server, USB flash drive or PC\u003c\/li\u003e \u003cli\u003eNo software is required\u003c\/li\u003e \u003cli\u003eConveniently connect a keyboard, a barcode scanner, a printer or two stirrers to improve your workflow\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eSeamless simplicity\u003c\/h3\u003e \u003cp\u003eThe HI-6000 multiparameter meter features a user-friendly design for effortless control and seamless simplicity. The benchtop unit has a large capacitive touch screen with multi-touch support. The help menu supports you with an overview of the main functionalities through text and video tutorials for quick assistance.\u003c\/p\u003e \u003ch3\u003eUser-friendly interface\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eUser-friendly icons and symbols enable easy navigation and interpretation of instrument functions\u003c\/li\u003e \u003cli\u003eChoice of five different display modes: Standard, Simple GLP with calibration information, Full GLP with electrode status and calibration point details, Interactive graph updated in real-time,\u003c\/li\u003e \u003cli\u003eTabulated data with date, time and notes\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e10 user profiles\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eFor direct access to daily analyses, users can save their procedures in profiles grouping all their method configuration data.\u003c\/li\u003e \u003cli\u003eEach user profile is password-protected\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eOn-board help and video tutorials\u003c\/h3\u003e \u003cp\u003eThe help menu supports users with a brief overview of the system’s main functionalities through text and video tutorials.\u003c\/p\u003e \u003ch3\u003eCertified accuracy\u003c\/h3\u003e \u003cp\u003eOur technical department offers a comprehensive certification and periodic calibration service, ensuring that your measuring instruments are always reliable and comply with the required standards. Each instrument, module, and probe is provided with a quality certificate, guaranteeing their high performance.\u003c\/p\u003e \u003cp\u003eRegular maintenance of instruments is essential for those operating quality management systems, as it helps maintain precision and reliability in measurements, aspects that can be verified during audits.\u003c\/p\u003e \u003ch3\u003eOngoing support\u003c\/h3\u003e \u003cp\u003eOur technical team is here to help you with:\u003c\/p\u003e \u003cul\u003e \u003cli\u003ePhone support\u003c\/li\u003e \u003cli\u003eQuick assistance\u003c\/li\u003e \u003cli\u003eAdvice on choosing the right electrodes for your application\u003c\/li\u003e \u003cli\u003eCalibration services\u003c\/li\u003e \u003cli\u003eRepairs on our premises\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135401.png\" alt=\"a close-up image of the HI-6000 modular multiparameter system modules\" width=\"1000\" height=\"393\"\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eAbout the HI-6000 modules\u003c\/h2\u003e \u003cp\u003eThe HI-6222 pH\/ORP\/ISE kit includes the HI-6000-2 pH\/ISE module and HI-6000-4 DO module, covering key measurement parameters often used within research and commercial laboratories. \u003c\/p\u003e \u003cp\u003eThe Hanna HI-6000-2 module for the HI-6000 Advanced Multiparameter Meter provides a repeatable, accurate solution for measuring pH, ORP and ISE. This module can be combined with up to two other modules at once in the HI-6000 system, allowing for the measurement of a wide range of samples simultaneously. \u003c\/p\u003e \u003cp\u003eThe HI-6000-4 module for the HI-6000 Benchtop Advance Benchtop Multiparameter Meter offers a reliable, accurate and repeatable solution to measure dissolved oxygen within fresh and saltwater samples. This module supports numerous dissolved oxygen applications, such as oxygen uptake rate, specific oxygen uptake rate and biological oxygen demand.\u003c\/p\u003e \u003cp\u003eModules available for the HI-6000 include: \u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-6000-1 module for pH\/ORP\u003c\/li\u003e \u003cli\u003eHI-6000-2 module for pH\/ORP\/ISE\u003c\/li\u003e \u003cli\u003eHI-6000-3 module for EC\u003c\/li\u003e \u003cli\u003eHI-6000-4 module for DO\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eModules can be ordered individually, allowing you to further expand the functionality of the HI-6000 beyond your kit at any time.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135207.png\" alt=\"a close-up image of the HI-6000 multiparameter modular system featuring three displays for different parameters\" width=\"1000\" height=\"447\"\u003e\u003c\/p\u003e \u003ch2\u003eHI-6000 Features\u003c\/h2\u003e \u003ch3\u003ePlug-and-play modular design\u003c\/h3\u003e \u003cp\u003eThe HI-6000 provides full flexibility to create the multiparameter meter that suits your requirements. ‘Plug-and-play’ modules can be easily swapped to configure the HI-6000 to suit your workflow and volume of testing, allowing this benchtop multimeter to adapt and evolve for accurate, repeatable measurement over a range of parameters.\u003c\/p\u003e \u003ch3\u003eComprehensive parameter range\u003c\/h3\u003e \u003cp\u003eThe HI-6000 modular units cover a comprehensive selection of the most common parameters for laboratories when combined with suitable Hanna Instruments electrodes and probes. Measure pH, ORP, ISE, DO and EC with exceptional accuracy across a wide range, including niche areas, industrial purposes and environmental applications.\u003c\/p\u003e \u003cp\u003eThe HI-6000-2 ISE, pH and ORP module introduces a new parameter into the HI-6000 range of laboratory-grade meters. This module is compatible with Hanna’s comprehensive range of ISE electrodes for the measurement of niche parameters in samples according to industry requirements.\u003c\/p\u003e \u003cp\u003eThe EC module HI-6000-3 in combination with the HI-6000 system provides an ideal solution for the three stages of USP \u0026lt;645\u0026gt;, with all three stages programmed directly into the meter ready to use out of the box.\u003c\/p\u003e \u003ch3\u003eCompatible with Hanna laboratory-grade probes and electrodes\u003c\/h3\u003e \u003cp\u003eCombine the HI-6000 modules with Hanna’s highly accurate probes and electrodes for reliability in testing. Each module has a recommended probe configuration for accurate testing. The HI-2000-2 pH, ISE and ORP modules are compatible with Hanna’s range of ion-selective electrodes, allowing you to tailor your HI-6000 multiparameter meter to your specific requirements for measurement.\u003c\/p\u003e \u003ch3\u003eModern, functional design\u003c\/h3\u003e \u003cp\u003eThe HI-6000 series is designed to be an ideal solution for modern laboratories. A streamlined design with a large capacitive touch screen that works even with gloves and a small footprint allows this advanced meter to take up less space while providing all the functionality of a multiparameter meter with swappable modules. The electrode arms can be placed on both or either side for additional flexibility in the lab.\u003c\/p\u003e \u003ch3\u003eExceptional accuracy across all parameters\u003c\/h3\u003e \u003cp\u003eThe HI-6000 is a highly accurate, laboratory-grade multiparameter meter. In combination with Hanna electrodes and probes, each module of the HI-6000 provides exceptionally accurate, repeatable measurements from testing. In-built features such as galvanic isolation ensure the same degree of accuracy without interference across a wide range of different samples and applications.\u003c\/p\u003e \u003ch3\u003eComplete accessibility\u003c\/h3\u003e \u003cp\u003eAccess data anywhere with the HI-6000, with WiFi and ethernet capability that allows measurements to be sent remotely to offices, other labs or directly to clients as required. The HI-6000 series can also export .csv universal data via a USB stick or to a connected printer or PC. \u003c\/p\u003e \u003ch3\u003eUser-friendly interface\u003c\/h3\u003e \u003cp\u003eHI-6000 meters are designed to be easy to follow, with user-friendly menus and an intuitive interface to reduce the time between setup and measurement. The settings menu includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eNetwork\u003c\/li\u003e \u003cli\u003eConnect and Print\u003c\/li\u003e \u003cli\u003eSystem\u003c\/li\u003e \u003cli\u003eCustom Users\u003c\/li\u003e \u003cli\u003eUser Account Management\u003c\/li\u003e \u003cli\u003eInfo Screen\u003c\/li\u003e \u003cli\u003eLog Recall\u003c\/li\u003e \u003cli\u003eLog History and Sharing\u003c\/li\u003e \u003cli\u003eLog Detail\u003c\/li\u003e \u003cli\u003eOn-Board Help\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eFive views, three measurements\u003c\/h3\u003e \u003cp\u003eThe HI-6000 can measure up to three samples simultaneously, splitting the screen in half or into thirds depending on your measurement requirements. Five individual views are available on-screen:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eBasic View:\u003c\/strong\u003e A simplified display of the measurement unit, measured value and temperature source.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSimple GLP View:\u003c\/strong\u003e A more complex display with the last calibration date and time, Offset value, average slope and electrode condition.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFull GLP View:\u003c\/strong\u003e A complete display including electrode symbol and used buffers tray in addition to all of the above.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGraph View:\u003c\/strong\u003e A live, plotted graph of the measured value\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eTabulated View:\u003c\/strong\u003e A classic table-style display featuring all measured values in chronological order with date, time and notes.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eUp to one million data points\u003c\/h3\u003e \u003cp\u003eThe HI-6000 has the capacity for up to 1 million individual data points, complete with time and date stamps for practical organisation and management. This data is accessible via WiFi and ethernet to FTP and email as well as over a USB stick or direct connection to a laptop, PC or printer.\u003c\/p\u003e \u003ch3\u003eComplete alarm system\u003c\/h3\u003e \u003cp\u003eBoth audible and visual alarms are available for the HI-6000, allowing you to be notified of any measurements that are outside of the correct ranges. Customise the ranges directly to set audible, visual or both alarms that activate outside of the defined limit, saving time in identifying potential calibration or sample problems.\u003c\/p\u003e \u003ch3\u003eUSB C and USB A functionality\u003c\/h3\u003e \u003cp\u003eBoth USB A and USB C connections are included with the HI-6000 series, allowing you to easily transfer data and connect peripherals such as a keyboard. Data from measurements are exported in a universal .csv format, requiring no additional software to access logged data on any laptop or PC.\u003c\/p\u003e \u003ch3\u003eVideo and text tutorial system\u003c\/h3\u003e \u003cp\u003eAn in-built tutorial system available through the HELP button makes the learning curve for the HI-6000 series as minimal as possible. Both text instructions and video tutorials are available, matching your preferred learning style for the setup of the HI-6000.\u003c\/p\u003e \u003ch3\u003eCreate and manage users\u003c\/h3\u003e \u003cp\u003eA complete user management system allows the HI-6000 multiparameter lab meter to be customised for individual students and technicians. Both administrator and standard accounts can be created, with the administrator role having full management of standard accounts via the Account Management Screen to assign or remove permissions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135504.png\" alt=\"an image of the Hanna Instruments HI-6000 modular multiparameter meter\" width=\"1000\" height=\"461\"\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eFAQs\u003c\/h2\u003e \u003ch3\u003eWhat is included with this meter kit?\u003c\/h3\u003e \u003cp\u003eThis kit for the HI-6000 laboratory grade meter includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-6000 modular multiparameter meter system\u003c\/li\u003e \u003cli\u003eHI-6000-2 pH\/ISE module\u003c\/li\u003e \u003cli\u003eHI-6000-4 DO module\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-764833 polarographic DO probe\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003eA calibration solution starter kit for pH and DO\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eHow do you swap modules?\u003c\/h3\u003e \u003cp\u003eSwapping modules with the HI-6000 multimeter is easy, with a simple latch and screw feature that holds the module firmly in place while allowing for fast and easy module swapping. Three modules can be used at any time with the HI-6000 benchtop meter, with split-screen functionality to view all sample measurements at the same time.\u003c\/p\u003e \u003ch3\u003eCan I book a demonstration of the HI-6000 modular system?\u003c\/h3\u003e \u003ch3\u003eIs the HI-6000 suitable for use in a laboratory?\u003c\/h3\u003e \u003cp\u003eThe HI-6000 modular meter is specifically designed for use in a laboratory environment for applications in various industries and businesses as well as for labs that provide outsourced services to their clients. This lab-grade multiparameter meter provides exceptional accuracy across all parameters, including dissolved oxygen, conductivity, pH, ORP and ISE.\u003c\/p\u003e \u003ch3\u003eWhat are the key features of the HI-6000?\u003c\/h3\u003e \u003cp\u003eSome of the key features of the Hanna HI-6000 include:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eModular design with four different modules\u003c\/li\u003e \u003cli\u003e‘Plug-and-play’ modular functionality\u003c\/li\u003e \u003cli\u003eCompatible with a range of Hanna electrodes and probes\u003c\/li\u003e \u003cli\u003eSplit screen for measurements\u003c\/li\u003e \u003cli\u003eWiFi and ethernet connectivity\u003c\/li\u003e \u003cli\u003eUser-friendly interface\u003c\/li\u003e \u003cli\u003eFlexible, compact design\u003c\/li\u003e \u003cli\u003eExceptional accuracy and repeatability\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCan I get training on the HI-6000?\u003c\/h3\u003e \u003ch3\u003eWhat industries is the HI-6000 suitable for?\u003c\/h3\u003e \u003cp\u003eThe modular nature of the HI-6000 benchtop lab meter and the six individual kits available allow this instrument to be customised to the requirements of a wide range of industries and applications. \u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-6542P-02 pH\/ORP\/ISE + Polarographic DO Kit\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eISE\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1 x 10-6 to 9.99 x 1010 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1; 0.1; 0.01; 0.001 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV offset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard buffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOffset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable; Isopotential point: -2.000 to 20.000pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDissolved Oxygen\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eRefer to individual specifications for probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-764833 Polarographic probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5 % of reading ±1, least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eBarometric Pressure\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mmHg; 600 to 1133 mBar; 60 to 113.32 kPa; 17.72 to 33.46 inHg; 8.702 to 16.436 psi; 0.592 to 1.1184 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mmHg; 0.1 mBar; 0.01 kPa; 0.01 inHg; 0.001 psi; 0.0001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mmHg within ±15 % from the calibration point ±3 mmHg ±1 least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eRefer to specification of probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDO Calibration\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoints\u003c\/td\u003e\n\u003ctd\u003eOne or two points at 100.0% (8.26 mg\/L) and 0.0% (0.00 mg\/L) automatic. Manual using a value entered by the user in % saturation, mg\/L or ppm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point, configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003eManual; 0.00 to 45.00 PSU or ppt 0.0 to 130.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640069562741,"sku":"HI-6542P-02","price":1182.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-6542p-02-ph-orp-ise-polarographic-do-multiparameter-modular-benchtop-system.jpg?v=1791580399"},{"product_id":"hanna-instruments-hi-6553-ph-orp-ise-ec-optical-do-multiparameter-modular-benchtop-meter","title":"Hanna Instruments HI-6553 pH\/ORP\/ISE + EC + Optical DO Multiparameter Modular Benchtop Meter","description":"\u003ch3\u003eHI-6553-02 pH\/ORP\/ISE + EC + Optical DO Multiparameter Modular Benchtop System\u003c\/h3\u003e \u003cp\u003eThe HI-6553 Kit for the HI-6000 includes the HI-6000 modular multiparameter meter system, a HI-6000-2 pH\/ISE module, a HI-6000-3 EC module and a HI-6000-4 dissolved oxygen module. Also included is the \u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e, \u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e, \u003cspan\u003eHI-7631233 EC \u0026amp; resistivity probe\u003c\/span\u003e and \u003cspan\u003e\u003cspan\u003eHI-7641133 optical DO probe\u003c\/span\u003e\u003c\/span\u003e. This kit includes everything needed to accurately measure DO, EC and pH out-of-the-box, including a calibration solution starter set.\u003c\/p\u003e \u003cp\u003eHI-6000 is a fully flexible measurement platform that can be customised according to the user’s application needs. Designed and developed using the latest generation technologies, it gives complete control over measurements.\u003c\/p\u003e \u003cp\u003eSix different pre-built kits are available for the HI-6000 multimeter, including the modules and electrodes required for laboratory-grade measurement:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6222 pH\/ORP\/ISE Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6522 pH\/ORP\/ISE + EC Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6542 pH\/ORP\/ISE + Optical DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6542\/P pH\/ORP\/ISE + Polarographic DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6553 pH\/ORP\/ISE + EC + Optical DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003ciframe width=\"1903\" height=\"750\" src=\"https:\/\/www.youtube.com\/embed\/tFJ33akvrmE\" title=\"Go Modular: The HI-6000 Multiparameter Modular System from Hanna Instruments\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e \u003ch3\u003eAccurate \u0026amp; Reliable\u003c\/h3\u003e \u003cp\u003eTogether with appropriate electrodes, the meter provides highly accurate and reliable measurement for all laboratories. Up to three measurement channels can be viewed simultaneously. Views can be mixed and matched. Data can be shown in basic or in full detail, in a table or plotted as a graph.\u003c\/p\u003e \u003cp\u003eThe HI-6000 Series allows for up to 5-point calibration for pH, ISE and Conductivity for optimum results.\u003c\/p\u003e \u003cul\u003e \u003cli\u003epH calibration up to 5 points with 8 stored standard buffers and 5 custom buffers\u003c\/li\u003e \u003cli\u003eISE calibration up to 5 points with 5 stored standards and 5 custom buffers\u003c\/li\u003e \u003cli\u003eConductivity calibration up to 5 points with 6 stored standards and 1 user standard\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eGo digital\u003c\/h3\u003e \u003cp\u003eThe HI-6000 multimeter helps you avoid errors caused by manual transcription of results, thanks to simple and flexible data management. The instrument can store up to 1,000,000 data points for each user.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eData can be shared via Wi-Fi, Ethernet, email, web server, USB flash drive or PC\u003c\/li\u003e \u003cli\u003eNo software is required\u003c\/li\u003e \u003cli\u003eConveniently connect a keyboard, a barcode scanner, a printer or two stirrers to improve your workflow\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eSeamless simplicity\u003c\/h3\u003e \u003cp\u003eThe HI-6000 multiparameter meter features a user-friendly design for effortless control and seamless simplicity. The benchtop unit has a large capacitive touch screen with multi-touch support. The help menu supports you with an overview of the main functionalities through text and video tutorials for quick assistance.\u003c\/p\u003e \u003ch3\u003eUser-friendly interface\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eUser-friendly icons and symbols enable easy navigation and interpretation of instrument functions\u003c\/li\u003e \u003cli\u003eChoice of five different display modes: Standard, Simple GLP with calibration information, Full GLP with electrode status and calibration point details, Interactive graph updated in real-time,\u003c\/li\u003e \u003cli\u003eTabulated data with date, time and notes\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e10 user profiles\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eFor direct access to daily analyses, users can save their procedures in profiles grouping all their method configuration data.\u003c\/li\u003e \u003cli\u003eEach user profile is password-protected\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eOn-board help and video tutorials\u003c\/h3\u003e \u003cp\u003eThe help menu supports users with a brief overview of the system’s main functionalities through text and video tutorials.\u003c\/p\u003e \u003ch3\u003eCertified accuracy\u003c\/h3\u003e \u003cp\u003eOur technical department offers a comprehensive certification and periodic calibration service, ensuring that your measuring instruments are always reliable and comply with the required standards. Each instrument, module, and probe is provided with a quality certificate, guaranteeing their high performance.\u003c\/p\u003e \u003cp\u003eRegular maintenance of instruments is essential for those operating quality management systems, as it helps maintain precision and reliability in measurements, aspects that can be verified during audits.\u003c\/p\u003e \u003ch3\u003eOngoing support\u003c\/h3\u003e \u003cp\u003eOur technical team is here to help you with:\u003c\/p\u003e \u003cul\u003e \u003cli\u003ePhone support\u003c\/li\u003e \u003cli\u003eQuick assistance\u003c\/li\u003e \u003cli\u003eAdvice on choosing the right electrodes for your application\u003c\/li\u003e \u003cli\u003eCalibration services\u003c\/li\u003e \u003cli\u003eRepairs on our premises\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135401.png\" alt=\"a close-up image of the HI-6000 modular multiparameter system modules\" width=\"1000\" height=\"393\"\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eAbout the HI-6000 modules\u003c\/h2\u003e \u003cp\u003eThe HI-6222 pH\/ORP\/ISE kit includes the HI-6000-2 pH\/ISE module, HI-6000-3 EC module and HI-6000-4 DO module, covering all of the key measurement parameters required for laboratory measurement. \u003c\/p\u003e \u003cp\u003eThe Hanna HI-6000-2 module for the HI-6000 Advanced Multiparameter Meter provides a repeatable, accurate solution for measuring pH, ORP and ISE. This module can be combined with up to two other modules at once in the HI-6000 system, allowing for the measurement of a wide range of samples simultaneously. \u003c\/p\u003e \u003cp\u003eThe HI-6000-3 module for the Hanna HI-6000 Advanced Benchtop Meter is an accurate and reliable solution for measuring conductivity (μS\/cm, mS\/cm), resistivity (Ω·cm, kΩ·cm, MΩ·cm), TDS (ppm, ppt) and salinity (ppt, PSU, %) with temperature. This module is specifically designed for conductivity measurements required to prepare water for injection according to USP \u0026lt;645\u0026gt;.\u003c\/p\u003e \u003cp\u003eThe HI-6000-4 module for the HI-6000 Benchtop Advance Benchtop Multiparameter Meter offers a reliable, accurate and repeatable solution to measure dissolved oxygen within fresh and saltwater samples. This module supports numerous dissolved oxygen applications, such as oxygen uptake rate, specific oxygen uptake rate and biological oxygen demand.\u003c\/p\u003e \u003cp\u003eModules available for the HI-6000 include: \u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-6000-1 module for pH\/ORP\u003c\/li\u003e \u003cli\u003eHI-6000-2 module for pH\/ORP\/ISE\u003c\/li\u003e \u003cli\u003eHI-6000-3 module for EC\u003c\/li\u003e \u003cli\u003eHI-6000-4 module for DO\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eModules can be ordered individually, allowing you to further expand the functionality of the HI-6000 beyond your kit at any time.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135207.png\" alt=\"a close-up image of the HI-6000 multiparameter modular system featuring three displays for different parameters\" width=\"1000\" height=\"447\"\u003e\u003c\/p\u003e \u003ch2\u003eHI-6000 Features\u003c\/h2\u003e \u003ch3\u003ePlug-and-play modular design\u003c\/h3\u003e \u003cp\u003eThe HI-6000 provides full flexibility to create the multiparameter meter that suits your requirements. ‘Plug-and-play’ modules can be easily swapped to configure the HI-6000 to suit your workflow and volume of testing, allowing this benchtop multimeter to adapt and evolve for accurate, repeatable measurement over a range of parameters.\u003c\/p\u003e \u003ch3\u003eComprehensive parameter range\u003c\/h3\u003e \u003cp\u003eThe HI-6000 modular units cover a comprehensive selection of the most common parameters for laboratories when combined with suitable Hanna Instruments electrodes and probes. Measure pH, ORP, ISE, DO and EC with exceptional accuracy across a wide range, including niche areas, industrial purposes and environmental applications.\u003c\/p\u003e \u003cp\u003eThe HI-6000-2 ISE, pH and ORP module introduces a new parameter into the HI-6000 range of laboratory-grade meters. This module is compatible with Hanna’s comprehensive range of ISE electrodes for the measurement of niche parameters in samples according to industry requirements.\u003c\/p\u003e \u003cp\u003eThe EC module HI-6000-3 in combination with the HI-6000 system provides an ideal solution for the three stages of USP \u0026lt;645\u0026gt;, with all three stages programmed directly into the meter ready to use out of the box.\u003c\/p\u003e \u003ch3\u003eCompatible with Hanna laboratory-grade probes and electrodes\u003c\/h3\u003e \u003cp\u003eCombine the HI-6000 modules with Hanna’s highly accurate probes and electrodes for reliability in testing. Each module has a recommended probe configuration for accurate testing. The HI-2000-2 pH, ISE and ORP modules are compatible with Hanna’s range of ion-selective electrodes, allowing you to tailor your HI-6000 multiparameter meter to your specific requirements for measurement.\u003c\/p\u003e \u003ch3\u003eModern, functional design\u003c\/h3\u003e \u003cp\u003eThe HI-6000 series is designed to be an ideal solution for modern laboratories. A streamlined design with a large capacitive touch screen that works even with gloves and a small footprint allows this advanced meter to take up less space while providing all the functionality of a multiparameter meter with swappable modules. The electrode arms can be placed on both or either side for additional flexibility in the lab.\u003c\/p\u003e \u003ch3\u003eExceptional accuracy across all parameters\u003c\/h3\u003e \u003cp\u003eThe HI-6000 is a highly accurate, laboratory-grade multiparameter meter. In combination with Hanna electrodes and probes, each module of the HI-6000 provides exceptionally accurate, repeatable measurements from testing. In-built features such as galvanic isolation ensure the same degree of accuracy without interference across a wide range of different samples and applications.\u003c\/p\u003e \u003ch3\u003eComplete accessibility\u003c\/h3\u003e \u003cp\u003eAccess data anywhere with the HI-6000, with WiFi and ethernet capability that allows measurements to be sent remotely to offices, other labs or directly to clients as required. The HI-6000 series can also export .csv universal data via a USB stick or to a connected printer or PC. \u003c\/p\u003e \u003ch3\u003eUser-friendly interface\u003c\/h3\u003e \u003cp\u003eHI-6000 meters are designed to be easy to follow, with user-friendly menus and an intuitive interface to reduce the time between setup and measurement. The settings menu includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eNetwork\u003c\/li\u003e \u003cli\u003eConnect and Print\u003c\/li\u003e \u003cli\u003eSystem\u003c\/li\u003e \u003cli\u003eCustom Users\u003c\/li\u003e \u003cli\u003eUser Account Management\u003c\/li\u003e \u003cli\u003eInfo Screen\u003c\/li\u003e \u003cli\u003eLog Recall\u003c\/li\u003e \u003cli\u003eLog History and Sharing\u003c\/li\u003e \u003cli\u003eLog Detail\u003c\/li\u003e \u003cli\u003eOn-Board Help\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eFive views, three measurements\u003c\/h3\u003e \u003cp\u003eThe HI-6000 can measure up to three samples simultaneously, splitting the screen in half or into thirds depending on your measurement requirements. Five individual views are available on-screen:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eBasic View:\u003c\/strong\u003e A simplified display of the measurement unit, measured value and temperature source.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSimple GLP View:\u003c\/strong\u003e A more complex display with the last calibration date and time, Offset value, average slope and electrode condition.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFull GLP View:\u003c\/strong\u003e A complete display including electrode symbol and used buffers tray in addition to all of the above.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGraph View:\u003c\/strong\u003e A live, plotted graph of the measured value\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eTabulated View:\u003c\/strong\u003e A classic table-style display featuring all measured values in chronological order with date, time and notes.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eUp to one million data points\u003c\/h3\u003e \u003cp\u003eThe HI-6000 has the capacity for up to 1 million individual data points, complete with time and date stamps for practical organisation and management. This data is accessible via WiFi and ethernet to FTP and email as well as over a USB stick or direct connection to a laptop, PC or printer.\u003c\/p\u003e \u003ch3\u003eComplete alarm system\u003c\/h3\u003e \u003cp\u003eBoth audible and visual alarms are available for the HI-6000, allowing you to be notified of any measurements that are outside of the correct ranges. Customise the ranges directly to set audible, visual or both alarms that activate outside of the defined limit, saving time in identifying potential calibration or sample problems.\u003c\/p\u003e \u003ch3\u003eUSB C and USB A functionality\u003c\/h3\u003e \u003cp\u003eBoth USB A and USB C connections are included with the HI-6000 series, allowing you to easily transfer data and connect peripherals such as a keyboard. Data from measurements are exported in a universal .csv format, requiring no additional software to access logged data on any laptop or PC.\u003c\/p\u003e \u003ch3\u003eVideo and text tutorial system\u003c\/h3\u003e \u003cp\u003eAn in-built tutorial system available through the HELP button makes the learning curve for the HI-6000 series as minimal as possible. Both text instructions and video tutorials are available, matching your preferred learning style for the setup of the HI-6000.\u003c\/p\u003e \u003ch3\u003eCreate and manage users\u003c\/h3\u003e \u003cp\u003eA complete user management system allows the HI-6000 multiparameter lab meter to be customised for individual students and technicians. Both administrator and standard accounts can be created, with the administrator role having full management of standard accounts via the Account Management Screen to assign or remove permissions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135504.png\" alt=\"an image of the Hanna Instruments HI-6000 modular multiparameter meter\" width=\"1000\" height=\"461\"\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eFAQs\u003c\/h2\u003e \u003ch3\u003eWhat is included with this meter kit?\u003c\/h3\u003e \u003cp\u003eThis kit for the HI-6000 laboratory grade meter includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-6000 modular multiparameter meter system\u003c\/li\u003e \u003cli\u003eHI-6000-2 pH\/ISE module\u003c\/li\u003e \u003cli\u003eHI-6000-3 EC module\u003c\/li\u003e \u003cli\u003eHI-6000-4 DO module\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-7631233 EC \u0026amp; resistivity probe\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003e\u003cspan\u003eHI-7641133 optical DO probe\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003eA calibration solution starter set for pH, EC and DO\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eHow do you swap modules?\u003c\/h3\u003e \u003cp\u003eSwapping modules with the HI-6000 multimeter is easy, with a simple latch and screw feature that holds the module firmly in place while allowing for fast and easy module swapping. Three modules can be used at any time with the HI-6000 benchtop meter, with split-screen functionality to view all sample measurements at the same time.\u003c\/p\u003e \u003ch3\u003eCan I book a demonstration of the HI-6000 modular system?\u003c\/h3\u003e \u003ch3\u003eIs the HI-6000 suitable for use in a laboratory?\u003c\/h3\u003e \u003cp\u003eThe HI-6000 modular meter is specifically designed for use in a laboratory environment for applications in various industries and businesses as well as for labs that provide outsourced services to their clients. This lab-grade multiparameter meter provides exceptional accuracy across all parameters, including dissolved oxygen, conductivity, pH, ORP and ISE.\u003c\/p\u003e \u003ch3\u003eWhat are the key features of the HI-6000?\u003c\/h3\u003e \u003cp\u003eSome of the key features of the Hanna HI-6000 include:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eModular design with four different modules\u003c\/li\u003e \u003cli\u003e‘Plug-and-play’ modular functionality\u003c\/li\u003e \u003cli\u003eCompatible with a range of Hanna electrodes and probes\u003c\/li\u003e \u003cli\u003eSplit screen for measurements\u003c\/li\u003e \u003cli\u003eWiFi and ethernet connectivity\u003c\/li\u003e \u003cli\u003eUser-friendly interface\u003c\/li\u003e \u003cli\u003eFlexible, compact design\u003c\/li\u003e \u003cli\u003eExceptional accuracy and repeatability\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCan I get training on the HI-6000?\u003c\/h3\u003e \u003ch3\u003eWhat industries is the HI-6000 suitable for?\u003c\/h3\u003e \u003cp\u003eThe modular nature of the HI-6000 benchtop lab meter and the six individual kits available allow this instrument to be customised to the requirements of a wide range of industries and applications. \u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-6553-02 pH\/ORP\/ISE + EC + Optical (opdo®) DO Kit\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eISE\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1 x 10-6 to 9.99 x 1010 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1; 0.1; 0.01; 0.001 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV offset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard buffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOffset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable; Isopotential point: -2.000 to 20.000pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eConductivity\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm; 100.0 to 999.9 μS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e0.0500 to 200.00 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Type\u003c\/td\u003e\n\u003ctd\u003eautomatic; manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eSingleMultiple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration solutions\u003c\/td\u003e\n\u003ctd\u003e84.00 μS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear, natural, standard, disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003eRange: 5.0 to 30.0˚C (41.0 to 86.0˚CResolution 0.1˚C \/ 0.1˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00%\/˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eResistivity\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 Ω・cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS)\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eSalinity\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 for Practical Scale \/ Natural Sea Water 0.1 % for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 point for Percent Scale, using 100% salinity calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C; -4.0 to 248.0˚F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDissolved Oxygen\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eRefer to individual specifications for probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-7641133 DO Probe Specification\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Body Material\u003c\/td\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart Cap™ material\u003c\/td\u003e\n\u003ctd\u003ePolypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable jacket material\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprobe guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd\u003eThermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd\u003e20m (29 PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Dimensions with guard\u003c\/td\u003e\n\u003ctd\u003e174 x 25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e45 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprobe ingress protection rating\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor type\u003c\/td\u003e\n\u003ctd\u003eOptical; luminescence quenching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640069628277,"sku":"HI-6553-02","price":1776.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-6553-02-ph-orp-ise-ec-optical-do-multiparameter-modular-benchtop-system_d437d1d3-1be7-4096-8e76-1d65138d6ca9.jpg?v=1791580401"},{"product_id":"hanna-instruments-hi-6553-p-ph-orp-ise-ec-polarographic-do-multiparameter-modular-benchtop-meter","title":"Hanna Instruments HI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Multiparameter Modular Benchtop Meter","description":"\u003ch3\u003eHI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Multiparameter Modular Benchtop System\u003c\/h3\u003e \u003cp\u003eThe HI-6553\/P Kit for the HI-6000 includes the HI-6000 modular multiparameter meter system, a HI-6000-2 pH\/ISE module, a HI-6000-3 EC module and a HI-6000-4 dissolved oxygen module. Also included is the \u003cspan\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e, \u003c\/span\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cspan\u003eHI-7631233 EC \u0026amp; resistivity probe\u003c\/span\u003e and \u003cspan\u003e\u003cspan\u003eHI-764833 polarographic DO probe\u003c\/span\u003e\u003c\/span\u003e. This kit includes everything needed to accurately measure DO, EC and pH immediately out of the box, including a calibration solution starter set.\u003c\/p\u003e \u003cp\u003eHI-6000 is a fully flexible measurement platform that can be customised according to the user’s application needs. Designed and developed using the latest generation technologies, it gives complete control over measurements.\u003c\/p\u003e \u003cp\u003eSix different pre-built kits are available for the HI-6000 multimeter, including the modules and electrodes required for laboratory-grade measurement:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6222 pH\/ORP\/ISE Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6522 pH\/ORP\/ISE + EC Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6542 pH\/ORP\/ISE + Optical DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6542\/P pH\/ORP\/ISE + Polarographic DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6553 pH\/ORP\/ISE + EC + Optical DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003ciframe width=\"1903\" height=\"750\" src=\"https:\/\/www.youtube.com\/embed\/tFJ33akvrmE\" title=\"Go Modular: The HI-6000 Multiparameter Modular System from Hanna Instruments\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e \u003ch3\u003eAccurate \u0026amp; Reliable\u003c\/h3\u003e \u003cp\u003eTogether with appropriate electrodes, the meter provides highly accurate and reliable measurement for all laboratories. Up to three measurement channels can be viewed simultaneously. Views can be mixed and matched. Data can be shown in basic or in full detail, in a table or plotted as a graph.\u003c\/p\u003e \u003cp\u003eThe HI-6000 Series allows for up to 5-point calibration for pH, ISE and Conductivity for optimum results.\u003c\/p\u003e \u003cul\u003e \u003cli\u003epH calibration up to 5 points with 8 stored standard buffers and 5 custom buffers\u003c\/li\u003e \u003cli\u003eISE calibration up to 5 points with 5 stored standards and 5 custom buffers\u003c\/li\u003e \u003cli\u003eConductivity calibration up to 5 points with 6 stored standards and 1 user standard\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eGo digital\u003c\/h3\u003e \u003cp\u003eThe HI-6000 multimeter helps you avoid errors caused by manual transcription of results, thanks to simple and flexible data management. The instrument can store up to 1,000,000 data points for each user.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eData can be shared via Wi-Fi, Ethernet, email, web server, USB flash drive or PC\u003c\/li\u003e \u003cli\u003eNo software is required\u003c\/li\u003e \u003cli\u003eConveniently connect a keyboard, a barcode scanner, a printer or two stirrers to improve your workflow\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eSeamless simplicity\u003c\/h3\u003e \u003cp\u003eThe HI-6000 multiparameter meter features a user-friendly design for effortless control and seamless simplicity. The benchtop unit has a large capacitive touch screen with multi-touch support. The help menu supports you with an overview of the main functionalities through text and video tutorials for quick assistance.\u003c\/p\u003e \u003ch3\u003eUser-friendly interface\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eUser-friendly icons and symbols enable easy navigation and interpretation of instrument functions\u003c\/li\u003e \u003cli\u003eChoice of five different display modes: Standard, Simple GLP with calibration information, Full GLP with electrode status and calibration point details, Interactive graph updated in real-time,\u003c\/li\u003e \u003cli\u003eTabulated data with date, time and notes\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003e10 user profiles\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eFor direct access to daily analyses, users can save their procedures in profiles grouping all their method configuration data.\u003c\/li\u003e \u003cli\u003eEach user profile is password-protected\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eOn-board help and video tutorials\u003c\/h3\u003e \u003cp\u003eThe help menu supports users with a brief overview of the system’s main functionalities through text and video tutorials.\u003c\/p\u003e \u003ch3\u003eCertified accuracy\u003c\/h3\u003e \u003cp\u003eOur technical department offers a comprehensive certification and periodic calibration service, ensuring that your measuring instruments are always reliable and comply with the required standards. Each instrument, module, and probe is provided with a quality certificate, guaranteeing their high performance.\u003c\/p\u003e \u003cp\u003eRegular maintenance of instruments is essential for those operating quality management systems, as it helps maintain precision and reliability in measurements, aspects that can be verified during audits.\u003c\/p\u003e \u003ch3\u003eOngoing support\u003c\/h3\u003e \u003cp\u003eOur technical team is here to help you with:\u003c\/p\u003e \u003cul\u003e \u003cli\u003ePhone support\u003c\/li\u003e \u003cli\u003eQuick assistance\u003c\/li\u003e \u003cli\u003eAdvice on choosing the right electrodes for your application\u003c\/li\u003e \u003cli\u003eCalibration services\u003c\/li\u003e \u003cli\u003eRepairs on our premises\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135401.png\" alt=\"a close-up image of the HI-6000 modular multiparameter system modules\" width=\"1000\" height=\"393\"\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eAbout the HI-6000 modules\u003c\/h2\u003e \u003cp\u003eThe HI-6222 pH\/ORP\/ISE kit includes the HI-6000-2 pH\/ISE module, HI-6000-3 EC module and HI-6000-4 DO module, covering all of the key measurement parameters required for laboratory measurement. \u003c\/p\u003e \u003cp\u003eThe Hanna HI-6000-2 module for the HI-6000 Advanced Multiparameter Meter provides a repeatable, accurate solution for measuring pH, ORP and ISE. This module can be combined with up to two other modules at once in the HI-6000 system, allowing for the measurement of a wide range of samples simultaneously. \u003c\/p\u003e \u003cp\u003eThe HI-6000-3 module for the Hanna HI-6000 Advanced Benchtop Meter is an accurate and reliable solution for measuring conductivity (μS\/cm, mS\/cm), resistivity (Ω·cm, kΩ·cm, MΩ·cm), TDS (ppm, ppt) and salinity (ppt, PSU, %) with temperature. This module is specifically designed for conductivity measurements required to prepare water for injection according to USP \u0026lt;645\u0026gt;.\u003c\/p\u003e \u003cp\u003eThe HI-6000-4 module for the HI-6000 Benchtop Advance Benchtop Multiparameter Meter offers a reliable, accurate and repeatable solution to measure dissolved oxygen within fresh and saltwater samples. This module supports numerous dissolved oxygen applications, such as oxygen uptake rate, specific oxygen uptake rate and biological oxygen demand.\u003c\/p\u003e \u003cp\u003eModules available for the HI-6000 include: \u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-6000-1 module for pH\/ORP\u003c\/li\u003e \u003cli\u003eHI-6000-2 module for pH\/ORP\/ISE\u003c\/li\u003e \u003cli\u003eHI-6000-3 module for EC\u003c\/li\u003e \u003cli\u003eHI-6000-4 module for DO\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eModules can be ordered individually, allowing you to further expand the functionality of the HI-6000 beyond your kit at any time.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135207.png\" alt=\"a close-up image of the HI-6000 multiparameter modular system featuring three displays for different parameters\" width=\"1000\" height=\"447\"\u003e\u003c\/p\u003e \u003ch2\u003eHI-6000 Features\u003c\/h2\u003e \u003ch3\u003ePlug-and-play modular design\u003c\/h3\u003e \u003cp\u003eThe HI-6000 provides full flexibility to create the multiparameter meter that suits your requirements. ‘Plug-and-play’ modules can be easily swapped to configure the HI-6000 to suit your workflow and volume of testing, allowing this benchtop multimeter to adapt and evolve for accurate, repeatable measurement over a range of parameters.\u003c\/p\u003e \u003ch3\u003eComprehensive parameter range\u003c\/h3\u003e \u003cp\u003eThe HI-6000 modular units cover a comprehensive selection of the most common parameters for laboratories when combined with suitable Hanna Instruments electrodes and probes. Measure pH, ORP, ISE, DO and EC with exceptional accuracy across a wide range, including niche areas, industrial purposes and environmental applications.\u003c\/p\u003e \u003cp\u003eThe HI-6000-2 ISE, pH and ORP module introduces a new parameter into the HI-6000 range of laboratory-grade meters. This module is compatible with Hanna’s comprehensive range of ISE electrodes for the measurement of niche parameters in samples according to industry requirements.\u003c\/p\u003e \u003cp\u003eThe EC module HI-6000-3 in combination with the HI-6000 system provides an ideal solution for the three stages of USP \u0026lt;645\u0026gt;, with all three stages programmed directly into the meter ready to use out of the box.\u003c\/p\u003e \u003ch3\u003eCompatible with Hanna laboratory-grade probes and electrodes\u003c\/h3\u003e \u003cp\u003eCombine the HI-6000 modules with Hanna’s highly accurate probes and electrodes for reliability in testing. Each module has a recommended probe configuration for accurate testing. The HI-2000-2 pH, ISE and ORP modules are compatible with Hanna’s range of ion-selective electrodes, allowing you to tailor your HI-6000 multiparameter meter to your specific requirements for measurement.\u003c\/p\u003e \u003ch3\u003eModern, functional design\u003c\/h3\u003e \u003cp\u003eThe HI-6000 series is designed to be an ideal solution for modern laboratories. A streamlined design with a large capacitive touch screen that works even with gloves and a small footprint allows this advanced meter to take up less space while providing all the functionality of a multiparameter meter with swappable modules. The electrode arms can be placed on both or either side for additional flexibility in the lab.\u003c\/p\u003e \u003ch3\u003eExceptional accuracy across all parameters\u003c\/h3\u003e \u003cp\u003eThe HI-6000 is a highly accurate, laboratory-grade multiparameter meter. In combination with Hanna electrodes and probes, each module of the HI-6000 provides exceptionally accurate, repeatable measurements from testing. In-built features such as galvanic isolation ensure the same degree of accuracy without interference across a wide range of different samples and applications.\u003c\/p\u003e \u003ch3\u003eComplete accessibility\u003c\/h3\u003e \u003cp\u003eAccess data anywhere with the HI-6000, with WiFi and ethernet capability that allows measurements to be sent remotely to offices, other labs or directly to clients as required. The HI-6000 series can also export .csv universal data via a USB stick or to a connected printer or PC. \u003c\/p\u003e \u003ch3\u003eUser-friendly interface\u003c\/h3\u003e \u003cp\u003eHI-6000 meters are designed to be easy to follow, with user-friendly menus and an intuitive interface to reduce the time between setup and measurement. The settings menu includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eNetwork\u003c\/li\u003e \u003cli\u003eConnect and Print\u003c\/li\u003e \u003cli\u003eSystem\u003c\/li\u003e \u003cli\u003eCustom Users\u003c\/li\u003e \u003cli\u003eUser Account Management\u003c\/li\u003e \u003cli\u003eInfo Screen\u003c\/li\u003e \u003cli\u003eLog Recall\u003c\/li\u003e \u003cli\u003eLog History and Sharing\u003c\/li\u003e \u003cli\u003eLog Detail\u003c\/li\u003e \u003cli\u003eOn-Board Help\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eFive views, three measurements\u003c\/h3\u003e \u003cp\u003eThe HI-6000 can measure up to three samples simultaneously, splitting the screen in half or into thirds depending on your measurement requirements. Five individual views are available on-screen:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eBasic View:\u003c\/strong\u003e A simplified display of the measurement unit, measured value and temperature source.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSimple GLP View:\u003c\/strong\u003e A more complex display with the last calibration date and time, Offset value, average slope and electrode condition.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFull GLP View:\u003c\/strong\u003e A complete display including electrode symbol and used buffers tray in addition to all of the above.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGraph View:\u003c\/strong\u003e A live, plotted graph of the measured value\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eTabulated View:\u003c\/strong\u003e A classic table-style display featuring all measured values in chronological order with date, time and notes.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eUp to one million data points\u003c\/h3\u003e \u003cp\u003eThe HI-6000 has the capacity for up to 1 million individual data points, complete with time and date stamps for practical organisation and management. This data is accessible via WiFi and ethernet to FTP and email as well as over a USB stick or direct connection to a laptop, PC or printer.\u003c\/p\u003e \u003ch3\u003eComplete alarm system\u003c\/h3\u003e \u003cp\u003eBoth audible and visual alarms are available for the HI-6000, allowing you to be notified of any measurements that are outside of the correct ranges. Customise the ranges directly to set audible, visual or both alarms that activate outside of the defined limit, saving time in identifying potential calibration or sample problems.\u003c\/p\u003e \u003ch3\u003eUSB C and USB A functionality\u003c\/h3\u003e \u003cp\u003eBoth USB A and USB C connections are included with the HI-6000 series, allowing you to easily transfer data and connect peripherals such as a keyboard. Data from measurements are exported in a universal .csv format, requiring no additional software to access logged data on any laptop or PC.\u003c\/p\u003e \u003ch3\u003eVideo and text tutorial system\u003c\/h3\u003e \u003cp\u003eAn in-built tutorial system available through the HELP button makes the learning curve for the HI-6000 series as minimal as possible. Both text instructions and video tutorials are available, matching your preferred learning style for the setup of the HI-6000.\u003c\/p\u003e \u003ch3\u003eCreate and manage users\u003c\/h3\u003e \u003cp\u003eA complete user management system allows the HI-6000 multiparameter lab meter to be customised for individual students and technicians. Both administrator and standard accounts can be created, with the administrator role having full management of standard accounts via the Account Management Screen to assign or remove permissions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/HI-6000\/Screenshot%202024-10-21%20135504.png\" alt=\"an image of the Hanna Instruments HI-6000 modular multiparameter meter\" width=\"1000\" height=\"461\"\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eFAQs\u003c\/h2\u003e \u003ch3\u003eWhat is included with this meter kit?\u003c\/h3\u003e \u003cp\u003eThis kit for the HI-6000 laboratory grade meter includes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-6000 modular multiparameter meter system\u003c\/li\u003e \u003cli\u003eHI-6000-2 pH\/ISE module\u003c\/li\u003e \u003cli\u003eHI-6000-3 EC module\u003c\/li\u003e \u003cli\u003eHI-6000-4 DO module\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003e\u003cspan\u003eHI-7631233 EC \u0026amp; resistivity probe\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan\u003eHI-764833 polarographic DO probe\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003eA calibration solution starter set for pH, EC and DO\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eHow do you swap modules?\u003c\/h3\u003e \u003cp\u003eSwapping modules with the HI-6000 multimeter is easy, with a simple latch and screw feature that holds the module firmly in place while allowing for fast and easy module swapping. Three modules can be used at any time with the HI-6000 benchtop meter, with split-screen functionality to view all sample measurements at the same time.\u003c\/p\u003e \u003ch3\u003eCan I book a demonstration of the HI-6000 modular system?\u003c\/h3\u003e \u003ch3\u003eIs the HI-6000 suitable for use in a laboratory?\u003c\/h3\u003e \u003cp\u003eThe HI-6000 modular meter is specifically designed for use in a laboratory environment for applications in various industries and businesses as well as for labs that provide outsourced services to their clients. This lab-grade multiparameter meter provides exceptional accuracy across all parameters, including dissolved oxygen, conductivity, pH, ORP and ISE.\u003c\/p\u003e \u003ch3\u003eWhat are the key features of the HI-6000?\u003c\/h3\u003e \u003cp\u003eSome of the key features of the Hanna HI-6000 include:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eModular design with four different modules\u003c\/li\u003e \u003cli\u003e‘Plug-and-play’ modular functionality\u003c\/li\u003e \u003cli\u003eCompatible with a range of Hanna electrodes and probes\u003c\/li\u003e \u003cli\u003eSplit screen for measurements\u003c\/li\u003e \u003cli\u003eWiFi and ethernet connectivity\u003c\/li\u003e \u003cli\u003eUser-friendly interface\u003c\/li\u003e \u003cli\u003eFlexible, compact design\u003c\/li\u003e \u003cli\u003eExceptional accuracy and repeatability\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eCan I get training on the HI-6000?\u003c\/h3\u003e \u003ch3\u003eWhat industries is the HI-6000 suitable for?\u003c\/h3\u003e \u003cp\u003eThe modular nature of the HI-6000 benchtop lab meter and the six individual kits available allow this instrument to be customised to the requirements of a wide range of industries and applications. \u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-6553P-02 pH\/ORP\/ISE + EC + Polarographic DO Kit\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eISE\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1 x 10-6 to 9.99 x 1010 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1; 0.1; 0.01; 0.001 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV offset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard buffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOffset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable; Isopotential point: -2.000 to 20.000pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eConductivity\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm; 100.0 to 999.9 μS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e0.0500 to 200.00 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Type\u003c\/td\u003e\n\u003ctd\u003eautomatic; manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eSingleMultiple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration solutions\u003c\/td\u003e\n\u003ctd\u003e84.00 μS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear, natural, standard, disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003eRange: 5.0 to 30.0˚C (41.0 to 86.0˚CResolution 0.1˚C \/ 0.1˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00%\/˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eResistivity\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 Ω・cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS)\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eSalinity\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 for Practical Scale \/ Natural Sea Water 0.1 % for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 point for Percent Scale, using 100% salinity calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C; -4.0 to 248.0˚F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDissolved Oxygen\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eRefer to individual specifications for probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHI-764833 Polarographic probe\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5 % of reading ±1, least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eBarometric Pressure\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mmHg; 600 to 1133 mBar; 60 to 113.32 kPa; 17.72 to 33.46 inHg; 8.702 to 16.436 psi; 0.592 to 1.1184 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mmHg; 0.1 mBar; 0.01 kPa; 0.01 inHg; 0.001 psi; 0.0001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mmHg within ±15 % from the calibration point ±3 mmHg ±1 least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eRefer to specification of probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eDO Calibration\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoints\u003c\/td\u003e\n\u003ctd\u003eOne or two points at 100.0% (8.26 mg\/L) and 0.0% (0.00 mg\/L) automatic. Manual using a value entered by the user in % saturation, mg\/L or ppm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point, configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003eManual; 0.00 to 45.00 PSU or ppt 0.0 to 130.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640069693813,"sku":"HI-6553P-02","price":1380.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-6553p-02-ph-orp-ise-ec-polarographic-do-multiparameter-modular-benchtop-system_ece5a86b-663d-4d5c-b454-913e9045457a.jpg?v=1791580403"},{"product_id":"hanna-instruments-hi-943500c-conductivity-controller-low-range","title":"Hanna Instruments HI-943500C Conductivity Controller (Low Range)","description":"\u003cp\u003eThis controller allows the direct connection of a potentiometric conductivity probe (HI-7638) with a cable up to 20 metres long, without using any transmitter.\u003c\/p\u003e\u003cp\u003eFour different models are available with different measurement ranges to satisfy any application requirements.\u003c\/p\u003e \u003cp\u003eThe output configuration for connecting a recorder or a PLC can be chosen between 0-20 or 4-20 mA.\u003c\/p\u003e \u003cp\u003eThe LED on the front panel indicates the operating status of the controller.\u003c\/p\u003e \u003cp\u003eThe automatic temperature compensation (ATC) is performed directly by the HI-7638 probe with built-in temperature sensor.\u003c\/p\u003e \u003cp\u003eThe front panel is protected behind a transparent splash-proof cover.\u003c\/p\u003e \u003cp\u003e\u003cbr\u003e \u003cb\u003eOrder Information:\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe HI-943500 series is supplied with mounting brackets and instructions.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0 to 1999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic, 0 to 60°C (32 to 140°F), with ß=2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint Relay\u003c\/td\u003e\n\u003ctd\u003e1, isolated, 2A, Max. 240 V, resistive load, 1,000,000 strokes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay\u003c\/td\u003e\n\u003ctd\u003e1, isolated, 2A, Max. 240 V, resistive load, 1,000,000 strokes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e115\/230 ±10% Vac; 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eBlack anodised aluminium body; front and back with ABS;transparent splash-proof front cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-10 to 50°C (4 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Cutout\u003c\/td\u003e\n\u003ctd\u003e141 x 69 mm (5.6 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg (2.2 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640100987253,"sku":"HI-943500C","price":638.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-943500c-conductivity-controller-low-range.jpg?v=1791581310"},{"product_id":"hanna-instruments-hi-97107-disinfectants-portable-photometer-with-cal-check-meter-only","title":"Hanna Instruments HI-97107 Disinfectants Portable Photometer with CAL Check - meter only","description":"\u003cp\u003eThe Hanna HI-97107 Disinfectants Photometer is designed to measure the 7 most important parameters for Legionella control and compliance. Bromine, Free and Total Chlorine Low range, Total Chlorine UHR, Chlorine Dioxide, Hydrogen Peroxide, Ozone and pH are all included and results are displayed directly on the digital display without the need to refer to charts or tables.\u003c\/p\u003e\u003cp\u003eHI-97107 Disinfectants Portable Photometer with CAL Check - meter only\u003c\/p\u003e \u003cp\u003eThis multi-functional photometer is ideal for monitoring in the following industries:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eLegionella control and compliance for risk assessments, monitoring, and disinfectants\u003c\/li\u003e \u003cli\u003ePotable Biocides in spas, pools and drinking water\u003c\/li\u003e \u003cli\u003eDrinking water and wastewater\u003c\/li\u003e \u003cli\u003eWater tanks\u003c\/li\u003e \u003cli\u003eHot and cold water systems\u003c\/li\u003e \u003cli\u003eCooling towers and systems\u003c\/li\u003e \u003cli\u003ePapermills\u003c\/li\u003e \u003cli\u003eWater feature maintenance\u003c\/li\u003e \u003cli\u003eFood manufacturing – cleaning lines\u003c\/li\u003e \u003cli\u003eHoliday Parks\u003c\/li\u003e \u003cli\u003eHospitality\u003c\/li\u003e \u003cli\u003eHospitals\u003c\/li\u003e \u003cli\u003eTemporary water supplies eg: events\u003c\/li\u003e \u003cli\u003eFacilities management\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe HI-97107 is a multiparameter portable photometer designed specifically to meet the needs of Legionella compliance and control. Benefiting from Hanna’s years of experience as a manufacturer of analytical instruments it features the Hanna CAL Check™ functionality for maximum accuracy and the unique to Hanna built-in tutorial mode.\u003c\/p\u003e \u003cp\u003eThe highly accurate optical system is sealed from outside dust, dirt and water with an exclusive positive-locking system to ensure that the cuvettes are placed into the holder in the same position every time.\u003c\/p\u003e \u003cp\u003eWith the CAL Check™ functionality, users can validate the performance of the instrument at any time and apply a user calibration (if necessary). Hanna Instruments CAL Check™ cuvettes are made with NIST traceable standards.\u003c\/p\u003e \u003cp\u003eThe built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents and quantities.\u003c\/p\u003e \u003ch3\u003eAbout the seven parameters\u003c\/h3\u003e \u003cp\u003e\u003cb\u003eBromine\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eBromine is a powerful water disinfectant, particularly effective in hot water (treatment of pools and spas). Bromine can act as an alternative to chlorine.\u003c\/p\u003e \u003cp\u003eThe method for bromine is an adaptation of Standard Methods for the Examination of Water and Wastewater, DPD Method.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChlorine\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eChlorine is a widely used disinfectant. In order for it to be effective, the pH of the water should be less than 8.0. The method for chlorine is an adaptation of US EPA Method 330.5, DPD Colorimetric Method.\u003c\/p\u003e \u003cp\u003eThe method for pH is an adaptation of the Phenol Red Method.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChlorine Dioxide\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eChlorine Dioxide is a powerful and selective disinfectant used in water treatment across a broad pH range.\u003c\/p\u003e \u003cp\u003eide is an adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Ed., 4500 ClO₂ D.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eHydrogen Peroxide\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eHydrogen Peroxide is an environmentally friendly, broad spectrum disinfectant. The method for hydrogen peroxide is an adaptation of German Standard Methods for the Examination of Water and Wastewater DIN 38409-15.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eOzone\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eOzone is a widely used disinfectant in the treatment of drinking water, wastewater and swimming pools. The method for ozone is the DPD Colorimetric Method.\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003eAbout the Photometer\u003c\/h3\u003e \u003cp\u003e\u003cb\u003eWaterproof casing\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe casing offers IP67 waterproof protection and floats.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eBacklit graphic LCD\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe 128 x 64 pixel backlit graphic LCD allows for an intuitive user interface with virtual keys, battery status, and on-screen help and tutorials to guide the user through use of the meter.\u003c\/p\u003e \u003cp\u003e\u003cb\u003ePositive locking system\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe Hanna positive-locking system ensures cuvettes are placed into the holder in the same position every time.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eVirtual Keys\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eMenu available at the touch of a button\u003c\/p\u003e \u003cp\u003e\u003cb\u003eDedicated HELP button\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eA dedicated help key provides informational help relating to the current meter operation, and can be used at any stage in the setup or measurement process.\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003eOur advanced LED optical system features\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e8 nm narrow band interference filter that is accurate to ±1 nm and offers a 25% increase in light efficiency over conventional filters\u003c\/li\u003e \u003cli\u003eA reference detector that modulates the voltage to the LED for consistent light output\u003c\/li\u003e \u003cli\u003eA concave focusing lens that reduces errors from imperfections in the cuvette\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eHigh efficiency light source\u003c\/h3\u003e \u003cp\u003eLED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.\u003c\/p\u003e \u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/img\/cms\/light%20source%20insert.png\" alt=\"Light source\" width=\"526\" height=\"295\"\u003e\u003c\/p\u003e \u003ch3\u003eHigh quality filters\u003c\/h3\u003e \u003cp\u003eHigh tolerance optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received providing higher measurement stability and repeatability.\u003c\/p\u003e \u003ch3\u003eStable light source\u003c\/h3\u003e \u003cp\u003eThe internal reference system of Hanna photometers compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light, the readings are fast and reliable between blank (zero) measurements and sample measurements.\u003c\/p\u003e \u003ch3\u003eGreater light yield\u003c\/h3\u003e \u003cp\u003eA focusing lens collects all of the light that exits the cuvette, reducing errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.\u003c\/p\u003e \u003ch3\u003eLarge cuvette size\u003c\/h3\u003e \u003cp\u003eThe sample cell of these photometers fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples. The cuvette holder features ridges to protect scratching of the optical path by the cuvette.\u003c\/p\u003e \u003ch3\u003eKey features\u003c\/h3\u003e \u003cp\u003e\u003cb\u003eMethod and parameter\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eChosen parameter and method used is displayed along with the reading.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eMultiple measurement methods\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eMethod selection can be accessed by pressing the menu button and selecting Methods. Use the function keys to highlight the desired method.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eAuto logging\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eLog and recall the last 50 measurements.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eBuilt-in reaction timer\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eWaiting for the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eCAL Check™ functionality\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eHanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards.\u003c\/p\u003e \u003cp\u003eOur CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings. The CAL Check screen guides the user step-by-step through the validation process and user calibration.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eGLP data\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eGood Laboratory Practice (GLP) shows the date and time of the last user calibration.\u003c\/p\u003e \u003cp\u003eSetup options\u003c\/p\u003e \u003cp\u003eSetup options for meter personalization include date and time format, language, and enabling the tutorial mode.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eAuto-off protection\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eSupplied with 3 x standard AA batteries provides power 800 measurements to be taken. Our batter preserving auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eBattery status indicator indicates the amount of battery life left.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003eDedicated help\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eA dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eOn-screen tutorial mode with animations\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe built in tutorial mode guides users step-by-step through the measurement process.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eError messages\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eMessages appear on the display alerting to problems such as out of range, light low, light high, ambient temperature out of limits, and battery low.\u003c\/p\u003e \u003ch3\u003eHI-97107 What's included:\u003c\/h3\u003e \u003cp\u003eEach HI-97107 is delivered is supplied with:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSample cuvette with cap (2 pcs.)\u003c\/li\u003e \u003cli\u003ePlastic stopper (2 pcs.)\u003c\/li\u003e \u003cli\u003e1.5V AA alkaline battery (3 pcs.)\u003c\/li\u003e \u003cli\u003eBattery safety insert\u003c\/li\u003e \u003cli\u003eQuick reference guide with instructions for manual download and instrument quality certificate.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e2 Years meter\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eAccessories – to buy separately\u003c\/h3\u003e \u003cp\u003e\u003cb\u003eStandards\u003c\/b\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-97107-11 CAL Check™ Validation and Calibration Standards Cuvette Kit.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cb\u003eReagents\u003c\/b\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-96795-01 Hydrogen Peroxide reagents for 100 tests\u003c\/li\u003e \u003cli\u003eHI-96795-03 Hydrogen Peroxide reagents for 300 tests\u003c\/li\u003e \u003cli\u003eHI-93701-F Free Chlorine reagent for 300 tests (liquid)\u003c\/li\u003e \u003cli\u003eHI-93701-T Total Chlorine reagent for 300 tests (liquid)\u003c\/li\u003e \u003cli\u003eHI-93703-52 Glycine powder reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-93710-01 pH reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-93710-03 pH reagent for 300 tests\u003c\/li\u003e \u003cli\u003eHI-93716-01 Bromine reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-93716-03 Bromine reagent for 300 tests\u003c\/li\u003e \u003cli\u003eHI-93757-01 Ozone reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-93757-03 Ozone reagent for 300 tests\u003c\/li\u003e \u003cli\u003eHI-95771-01 Total Chlorine UHR reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-95771-03 Total Chlorine UHR reagent for 300 tests\u003c\/li\u003e \u003cli\u003eHI-96779-01 Chlorine Dioxide (Rapid) reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-96779-03 Chlorine Dioxide (Rapid) reagent for 300 tests\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cb\u003eOther \u003c\/b\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-7101422 Blue carrying case\u003c\/li\u003e \u003cli\u003eHI-731318 Cloth for wiping cuvettes (4 pcs.)\u003c\/li\u003e \u003cli\u003eHI-731331 Glass cuvette (4 pcs.)\u003c\/li\u003e \u003cli\u003eHI-731336N Cap for glass cuvette (4 pcs.)\u003c\/li\u003e \u003cli\u003eHI-740034P Cap for 100 mL beaker (10 pcs.)\u003c\/li\u003e \u003cli\u003eHI-740036P 100 mL plastic beaker (10 pcs.)\u003c\/li\u003e \u003cli\u003eHI-740143 1 mL graduated syringe (6 pcs.)\u003c\/li\u003e \u003cli\u003eHI-740144P Pipette tip for 1 mL graduated syringe (10 pcs.)\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eBromine\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 mg\/L (as Br₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.08 mg\/L ±3% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eFree and Total Chlorine LR\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy*\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAdaptation of US EPA Method 330.5, DPD Colorimetric Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTotal Chlorine UHR\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 500 mg\/L (as Cl₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mg\/L ±3% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of Standard Methods for Examination of Water and Wastewater, 20th Edition, 4500-Cl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eChlorine Dioxide (Rapid)\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as ClO₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.10 mg\/L ±5% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, 4500 ClO₂ D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHydrogen Peroxide\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 500 mg\/L H₂O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±3% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of DIN 38409-15, German Standard Methods for the Examination of Water and Wastewater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eOzone\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as O₃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 mg\/L ±3% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eDPD Colorimetric Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e6.5 to 8.5 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Phenol Red Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eMeasurement System\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eLight Emitting Diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter\u003c\/td\u003e\n\u003ctd\u003e525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter wavelength accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight detector\u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette type\u003c\/td\u003e\n\u003ctd\u003eRound 24.6 mm diameter (22 mm inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAdditional specifications\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto logging\u003c\/td\u003e\n\u003ctd\u003e50 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel black and white LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003eAfter 15 minutes of inactivity (30 minutes before a READ measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003e1.5 V AA Alkaline (3 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003eMore than 800 measurements (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e380 g (13.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase ingress protection rating\u003c\/td\u003e\n\u003ctd\u003eIP67, floating case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640102560117,"sku":"HI-97107","price":502.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-97107-disinfectants-portable-photometer-with-cal-check-meter-only_4a8b9d90-0729-4f24-92cc-c6452335e796.jpg?v=1791581355"},{"product_id":"hanna-instruments-hi-97107c-disinfectants-kit-including-photometer-calcheck-standards-and-carry-case","title":"Hanna Instruments HI-97107C Disinfectants Kit including photometer, CALCheck standards and carry case","description":"\u003cp\u003eThe Hanna HI-97107C Disinfectants Photometer kit is designed to measure the 7 most important parameters for Legionella control and compliance. Bromine, Free and Total Chlorine Low range, Total Chlorine UHR, Chlorine Dioxide, Hydrogen Peroxide, Ozone and pH are all included and results are displayed directly on the digital display without the need to refer to charts or tables. The complete kit here allows you to be ready to start testing. \u003cstrong\u003eNOTE: Items in the actual HI-97107C product case will differ from the display photo here.\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eHI-97107C Disinfectants Kit including photometer, CALCheck standards and carry case\u003c\/h3\u003e \u003cp\u003eEach HI-97107C is delivered in a rugged carrying case and is supplied with:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSample cuvette with cap (2 pcs.)\u003c\/li\u003e \u003cli\u003ePlastic stopper (2 pcs.)\u003c\/li\u003e \u003cli\u003eChlorine reagent kit\u003c\/li\u003e \u003cli\u003eReagent A, 30 mL dropper (1 pc.)\u003c\/li\u003e \u003cli\u003eReagent B, 30 mL dropper (1 pc.)\u003c\/li\u003e \u003cli\u003eReagent C, 20 mL dropper (1 pc.)\u003c\/li\u003e \u003cli\u003epH reagent, 30 mL dropper (1 pc.)\u003c\/li\u003e \u003cli\u003eBromine reagent (for 25 tests)\u003c\/li\u003e \u003cli\u003eOzone reagent (for 25 tests)\u003c\/li\u003e \u003cli\u003eGlycine powder (for 25 tests)\u003c\/li\u003e \u003cli\u003eUHR Chlorine reagent kit\u003c\/li\u003e \u003cli\u003eReagent A (for 25 tests)\u003c\/li\u003e \u003cli\u003eReagent B (for 25 tests)\u003c\/li\u003e \u003cli\u003eChlorine Dioxide (rapid) reagent kit\u003c\/li\u003e \u003cli\u003eReagent A, 30 mL dropper (1 pc.)\u003c\/li\u003e \u003cli\u003eReagent B (for 25 tests)\u003c\/li\u003e \u003cli\u003eHydrogen Peroxide reagent, 30 mL dropper (1 pc.)\u003c\/li\u003e \u003cli\u003eCloth for wiping cuvettes\u003c\/li\u003e \u003cli\u003eScissors\u003c\/li\u003e \u003cli\u003e1.5V AA alkaline battery (3 pcs.)\u003c\/li\u003e \u003cli\u003eBattery safety insert\u003c\/li\u003e \u003cli\u003eQuick reference guide with instructions for manual download and instrument quality certificate\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eAbout the HI-97107 Disinfectants photometer\u003c\/h3\u003e \u003cp\u003eThis multi-functional photometer is ideal for monitoring in the following industries:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eLegionella control and compliance for risk assessments, monitoring, and disinfectants\u003c\/li\u003e \u003cli\u003ePotable Biocides in spas, pools and drinking water\u003c\/li\u003e \u003cli\u003eDrinking water and wastewater\u003c\/li\u003e \u003cli\u003eWater tanks\u003c\/li\u003e \u003cli\u003eHot and cold water systems\u003c\/li\u003e \u003cli\u003eCooling towers and systems\u003c\/li\u003e \u003cli\u003ePapermills\u003c\/li\u003e \u003cli\u003eWater feature maintenance\u003c\/li\u003e \u003cli\u003eFood manufacturing – cleaning lines\u003c\/li\u003e \u003cli\u003eHoliday Parks\u003c\/li\u003e \u003cli\u003eHospitality\u003c\/li\u003e \u003cli\u003eHospitals\u003c\/li\u003e \u003cli\u003eTemporary water supplies eg: events\u003c\/li\u003e \u003cli\u003eFacilities management\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe HI-97107 is a multiparameter portable photometer designed specifically to meet the needs of Legionella compliance and control. Benefiting from Hanna’s years of experience as a manufacturer of analytical instruments it features the Hanna CAL Check™ functionality for maximum accuracy and the unique to Hanna built-in tutorial mode.\u003c\/p\u003e \u003cp\u003eThe highly accurate optical system is sealed from outside dust, dirt and water with an exclusive positive-locking system to ensure that the cuvettes are placed into the holder in the same position every time.\u003c\/p\u003e \u003cp\u003eWith the CAL Check™ functionality, users can validate the performance of the instrument at any time and apply a user calibration (if necessary). Hanna Instruments CAL Check™ cuvettes are made with NIST traceable standards.\u003c\/p\u003e \u003cp\u003eThe built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents and quantities.\u003c\/p\u003e \u003ch3\u003eAbout the seven parameters\u003c\/h3\u003e \u003cp\u003e\u003cb\u003eBromine\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eBromine is a powerful water disinfectant, particularly effective in hot water (treatment of pools and spas). Bromine can act as an alternative to chlorine.\u003c\/p\u003e \u003cp\u003eThe method for bromine is an adaptation of Standard Methods for the Examination of Water and Wastewater, DPD Method.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChlorine\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eChlorine is a widely used disinfectant. In order for it to be effective, the pH of the water should be less than 8.0. The method for chlorine is an adaptation of US EPA Method 330.5, DPD Colorimetric Method.\u003c\/p\u003e \u003cp\u003eThe method for pH is an adaptation of the Phenol Red Method.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eChlorine Dioxide\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eChlorine Dioxide is a powerful and selective disinfectant used in water treatment across a broad pH range.\u003c\/p\u003e \u003cp\u003eide is an adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Ed., 4500 ClO₂ D.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eHydrogen Peroxide\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eHydrogen Peroxide is an environmentally friendly, broad spectrum disinfectant. The method for hydrogen peroxide is an adaptation of German Standard Methods for the Examination of Water and Wastewater DIN 38409-15.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eOzone\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eOzone is a widely used disinfectant in the treatment of drinking water, wastewater and swimming pools. The method for ozone is the DPD Colorimetric Method.\u003c\/p\u003e \u003ch3\u003e\u003c\/h3\u003e \u003ch3\u003eFurther information about the Photometer\u003c\/h3\u003e \u003cp\u003e\u003cb\u003eWaterproof casing\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe casing offers IP67 waterproof protection and floats.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eBacklit graphic LCD\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe 128 x 64 pixel backlit graphic LCD allows for an intuitive user interface with virtual keys, battery status, and on-screen help and tutorials to guide the user through use of the meter.\u003c\/p\u003e \u003cp\u003e\u003cb\u003ePositive locking system\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe Hanna positive-locking system ensures cuvettes are placed into the holder in the same position every time.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eVirtual Keys\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eMenu available at the touch of a button\u003c\/p\u003e \u003cp\u003e\u003cb\u003eDedicated HELP button\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eA dedicated help key provides informational help relating to the current meter operation, and can be used at any stage in the setup or measurement process.\u003c\/p\u003e \u003ch3\u003eOur advanced LED optical system features\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e8 nm narrow band interference filter that is accurate to ±1 nm and offers a 25% increase in light efficiency over conventional filters\u003c\/li\u003e \u003cli\u003eA reference detector that modulates the voltage to the LED for consistent light output\u003c\/li\u003e \u003cli\u003eA concave focusing lens that reduces errors from imperfections in the cuvette\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eHigh efficiency light source\u003c\/h3\u003e \u003cp\u003eLED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability\u003c\/p\u003e \u003ch3\u003eHigh quality filters\u003c\/h3\u003e \u003cp\u003eHigh tolerance optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received providing higher measurement stability and repeatability.\u003c\/p\u003e \u003ch3\u003eStable light source\u003c\/h3\u003e \u003cp\u003eThe internal reference system of Hanna photometers compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light, the readings are fast and reliable between blank (zero) measurements and sample measurements.\u003c\/p\u003e \u003ch3\u003eGreater light yield\u003c\/h3\u003e \u003cp\u003eA focusing lens collects all of the light that exits the cuvette, reducing errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.\u003c\/p\u003e \u003ch3\u003eLarge cuvette size\u003c\/h3\u003e \u003cp\u003eThe sample cell of these photometers fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples. The cuvette holder features ridges to protect scratching of the optical path by the cuvette.\u003c\/p\u003e \u003ch3\u003eKey features\u003c\/h3\u003e \u003cp\u003e\u003cb\u003eMethod and parameter\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eChosen parameter and method used is displayed along with the reading.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eMultiple measurement methods\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eMethod selection can be accessed by pressing the menu button and selecting Methods. Use the function keys to highlight the desired method.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eAuto logging\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eLog and recall the last 50 measurements.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eBuilt-in reaction timer\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eWaiting for the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eCAL Check™ functionality\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eHanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards.\u003c\/p\u003e \u003cp\u003eOur CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings. The CAL Check screen guides the user step-by-step through the validation process and user calibration.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eGLP data\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eGood Laboratory Practice (GLP) shows the date and time of the last user calibration.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eSetup options\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eSetup options for meter personalization include date and time format, language, and enabling the tutorial mode.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eAuto-off protection\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eSupplied with 3 x standard AA batteries provides power 800 measurements to be taken. Our batter preserving auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eBattery status indicator indicates the amount of battery life left.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003e\u003cb\u003eDedicated help\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eA dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eOn-screen tutorial mode with animations\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eThe built in tutorial mode guides users step-by-step through the measurement process.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eError messages\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eMessages appear on the display alerting to problems such as out of range, light low, light high, ambient temperature out of limits, and battery low.\u003c\/p\u003e \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e2 Years meter\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eAccessories – replacements to buy separately\u003c\/h3\u003e \u003cp\u003e\u003cb\u003eStandards\u003c\/b\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-97107-11 CAL Check™ Validation and Calibration Standards Cuvette Kit.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cb\u003eReagents\u003c\/b\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-96795-01 Hydrogen Peroxide reagents for 100 tests\u003c\/li\u003e \u003cli\u003eHI-96795-03 Hydrogen Peroxide reagents for 300 tests\u003c\/li\u003e \u003cli\u003eHI-93701-F Free Chlorine reagent for 300 tests (liquid)\u003c\/li\u003e \u003cli\u003eHI-93701-T Total Chlorine reagent for 300 tests (liquid)\u003c\/li\u003e \u003cli\u003eHI-93703-52 Glycine powder reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-93710-01 pH reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-93710-03 pH reagent for 300 tests\u003c\/li\u003e \u003cli\u003eHI-93716-01 Bromine reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-93716-03 Bromine reagent for 300 tests\u003c\/li\u003e \u003cli\u003eHI-93757-01 Ozone reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-93757-03 Ozone reagent for 300 tests\u003c\/li\u003e \u003cli\u003eHI-95771-01 Total Chlorine UHR reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-95771-03 Total Chlorine UHR reagent for 300 tests\u003c\/li\u003e \u003cli\u003eHI-96779-01 Chlorine Dioxide (Rapid) reagent for 100 tests\u003c\/li\u003e \u003cli\u003eHI-96779-03 Chlorine Dioxide (Rapid) reagent for 300 tests\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cb\u003eOther replacements\u003c\/b\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHI-7101422 Blue carrying case\u003c\/li\u003e \u003cli\u003eHI-731318 Cloth for wiping cuvettes (4 pcs.)\u003c\/li\u003e \u003cli\u003eHI-731331 Glass cuvette (4 pcs.)\u003c\/li\u003e \u003cli\u003eHI-731336N Cap for glass cuvette (4 pcs.)\u003c\/li\u003e \u003cli\u003eHI-740034P Cap for 100 mL beaker (10 pcs.)\u003c\/li\u003e \u003cli\u003eHI-740036P 100 mL plastic beaker (10 pcs.)\u003c\/li\u003e \u003cli\u003eHI-740143 1 mL graduated syringe (6 pcs.)\u003c\/li\u003e \u003cli\u003eHI-740144P Pipette tip for 1 mL graduated syringe (10 pcs.)\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eBromine\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 mg\/L (as Br₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.08 mg\/L ±3% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eFree and Total Chlorine LR\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy*\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAdaptation of US EPA Method 330.5, DPD Colorimetric Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eTotal Chlorine UHR\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 500 mg\/L (as Cl₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mg\/L ±3% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of Standard Methods for Examination of Water and Wastewater, 20th Edition, 4500-Cl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eChlorine Dioxide (Rapid)\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as ClO₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.10 mg\/L ±5% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, 4500 ClO₂ D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eHydrogen Peroxide\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 500 mg\/L H₂O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±3% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of DIN 38409-15, German Standard Methods for the Examination of Water and Wastewater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eOzone\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as O₃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 mg\/L ±3% of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eDPD Colorimetric Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e6.5 to 8.5 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH of reading at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Phenol Red Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eMeasurement System\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eLight Emitting Diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter\u003c\/td\u003e\n\u003ctd\u003e525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter wavelength accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight detector\u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette type\u003c\/td\u003e\n\u003ctd\u003eRound 24.6 mm diameter (22 mm inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"text-align:left;\"\u003e\u003cstrong\u003eAdditional specifications\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto logging\u003c\/td\u003e\n\u003ctd\u003e50 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel black and white LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003eAfter 15 minutes of inactivity (30 minutes before a READ measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003e1.5 V AA Alkaline (3 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003eMore than 800 measurements (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e380 g (13.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase ingress protection rating\u003c\/td\u003e\n\u003ctd\u003eIP67, floating case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57640102658421,"sku":"HI-97107C","price":736.53,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-97107c-disinfection-kit-including-photometer-calcheck-standards-and-carry-case.jpg?v=1791581357"}],"url":"https:\/\/testallwater.co.uk\/collections\/process-instrumentation-and-control.oembed?page=2","provider":"Test All Water","version":"1.0","type":"link"}