{"title":"Poultry EC, Conductivity \u0026 Water Strength Testing","description":null,"products":[{"product_id":"hanna-instruments-83303-02-aquaculture-multi-parameter-photometer-with-ph-meter","title":"Hanna Instruments-83303-02 AquaCulture Multi-parameter Photometer with pH Meter","description":"One meter can be used for both photometric and pH measurements. The meter has 20 different programmed methods measuring 12 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003cbr\u003e\u003ch3\u003eHanna Instruments-83303 Aquaculture Photometer with pH meter\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable benchtop space, the Hanna Instruments-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input. Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMade with the aquaculture industry in mind, the Hanna Instruments-83303 is a comprehensive solution to maintaining optimal chemical and environmental conditions, preventing disease and increasing production.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 measures vital parameters such as Alkalinity, Calcium, Nitrite, and Phosphate. Alkalinity plays a part in a dynamic relationship with pH and CO2 concentrations, high alkalinity water lowers fluctuations in pH. The buffering capacity acts to store extra CO2 essential for photosynthesis in the ponds to produce oxygen. Maintaining calcium at certain levels is vital to proper fish growth and development. Excessive nitrite can be toxic to fish. When nitrite interacts with Haemoglobin, the iron becomes oxidised and the blood cell can no longer carry oxygen. Phosphate is essential to plant growth; too much phosphate in an aquaculture system can contribute to algal blooms decreasing dissolved oxygen vital for a successful ecosystem.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83303 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375336087,"sku":"HI-83303-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_2_82e0c6fb-4e30-4e5b-9e18-bcb58add9261.jpg?v=1624278828"},{"product_id":"hanna-instruments-83300-02-multi-parameter-benchtop-photometer-ph-meter","title":"Hanna Instruments-83300-02 Multi-parameter Benchtop Photometer \u0026 pH meter","description":"One meter can be used for both photometric and pH measurements. The meter has 60 different programmed methods measuring 37 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83300 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003cbr\u003e\u003ch3\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-83300 is a compact, multi-parameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFrom Aluminium to Zinc, the Hanna Instruments-83300 benchtop photometer measures 37 water quality parameters using 60 different methods. The photometer features an innovative optical system that uses LEDs, narrow band interference filters, and a focusing lens. It also has a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83300 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375467159,"sku":"HI-83300-02","price":1489.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_3_dc75fef9-64f1-4563-8b90-e8a5f746505a.jpg?v=1624278832"},{"product_id":"hanna-instruments-4114-potassium-combination-ise-electrode","title":"Hanna Instruments-4114 Potassium Combination ISE Electrode","description":"The Hanna Instruments-4114 is ideal for a variety of applications in wine, agriculture, and water analysis.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4114 is a Potassium Combination ISE ideal for the determination of Potassium ions in wine, waters, soils and biological samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4114 potassium ion selective electrode is a complete potentiometric cell that contains a silver\/silver chloride (Ag\/AgCl) reference housed within a PEI plastic body with a sodium chloride electrolyte. The internal elements are isolated from the sample by an organic polymer sensing membrane.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna’s liquid membrane combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFor the Hanna Instruments-4114 to measure potassium accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the potassium ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free potassium ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The Hanna Instruments-4114 potassium liquid membrane ISE can measure from 1µM (0.039 mg\/L) to 1M (39,100 mg\/L).\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354387951767,"sku":"HI-4114","price":1134.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-4114_potassium_combination_ise_electrode_338278d6-4c53-4683-b264-2188fcba759b.jpg?v=1624279203"},{"product_id":"hanna-instruments-98196-multiparameter-waterproof-meter","title":"Hanna Instruments-98196 Multiparameter Waterproof Meter","description":"\u003cp\u003e\u003cspan\u003eThe Hanna Instruments-98196 measures pH\/mV, ORP, Dissolved Oxygen, Atmospheric Pressure and Temperature.\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\u003cp\u003eHanna Instruments-98196 provides multi-parameter measurement in a compact and rugged IP67 waterproof enclosure. Ideal for demanding application, this meter features our rugged, quick connect multi-function probe with field replaceable sensors. The Hanna Instruments-98196 measures pH\/mV, ORP, Dissolved Oxygen, Atmospheric Pressure and Temperature\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eA backlit, graphic LCD provides easy to read resolution even in low-lit areas. A combination of dedicated and soft keys allows easy, intuitive operation in a choice of languages.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eHanna Instruments-98196 allows users to store up to 45,000 continuous or log-on demand samples with logging intervals from one second to three hours. Logged data can be later transferred to a PC with the Hanna Instruments-920015 micro USB cable and Hanna software.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eComprehensive GLP data includes data from the last five calibrations. The contextual Help Menu can be accessed to obtain on-screen information and assistance about each feature at the touch of a button.\u003c\/p\u003e\n\u003cbr\u003e\u003ch3\u003epH specific features\u003c\/h3\u003e\n\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eUp to three point calibration with five standard buffers and one custom buffer available\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eDissolved Oxygen specific features\u003c\/h3\u003e\n\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eDisplay units in % saturation of mg\/L (ppm)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSalinity compensation for concentration\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003ePressure compensation for concentration\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in barometer with user-selectable units (mmHg, inHg, atm, psi, kPa, mbar)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eTemperature compensation\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAutomatic polarisation of probe at startup\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eReady to use HDPE pre-tensioned membrane caps are easy to replace\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section four\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003cbr\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eIP67 rated waterproof, rugged enclosure for meter, IP68 for probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eColour-coded, field replaceable sensors\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAuto sensor recognition\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAutomatic logging of up to 45,000 samples\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eOn-screen context specific help is readily available at the press of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003ePC connectivity via opto-isolated micro-USB with Hanna software\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUp to 360 hours of battery life, powered by (4) 1.5V batteries\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eThe Hanna Instruments-7698196 probe features a quick connect DIN connector for a water tight connection\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354392539287,"sku":"HI-98196","price":1406.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-98196_multiparameter_waterproof_meter_0a771300-16ba-4a4f-bbd0-bce45ee4b28c.jpg?v=1624279302"},{"product_id":"hanna-instruments-hi-98199-ph-ec-do-digital-portable-meter","title":"HI-98199 pH, EC, DO digital portable meter (pH electrode included only)","description":"\u003ch3\u003epH electrode included\u003c\/h3\u003e\n\u003cp\u003eThe HI-98199 allows for the measurement of pH and temperature when used with the included HI-829113 digital pH probe.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUp to a three-point calibration with five standard buffers and one custom buffer available\u003c\/li\u003e\n\u003cli\u003epH in mV option is useful for diagnostics\u003c\/li\u003e\n\u003cli\u003eGLP data Offset, slope, date, time and buffers used\u003c\/li\u003e\n\u003cli\u003eAutomatically temperature compensated readings\u003c\/li\u003e\n\u003cli\u003epH sensor Gel filled and maintenance free\u003c\/li\u003e\n\u003cli\u003eDouble junction for reduced contamination of reference cell\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTemperature compensation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic polarisation of probe at startup\u003c\/li\u003e\n\u003cli\u003eReady-to-use HDPE pre-tensioned membrane caps are easy to replace\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBacklit Graphic LCD Display\u003c\/h3\u003e\n\u003cp\u003eThe HI-98199 features a backlit graphic LCD with on-screen help and the capability to display multiple parameters simultaneously. The use of virtual keys to provides for an intuitive user interface.\u003c\/p\u003e\n\u003ch3\u003eWaterproof Protection\u003c\/h3\u003e\n\u003cp\u003eHI-98199 is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probes feature an IP68 rating for continuous immersion in water.\u003c\/p\u003e\n\u003ch3\u003eQuick Connect Digital Probe\u003c\/h3\u003e\n\u003cp\u003epH, EC, and DO probes feature a Quick Connect DIN connector that makes a waterproof connection with the meter.\u003c\/p\u003e\n\u003ch3\u003eAuto-sensor Recognition\u003c\/h3\u003e\n\u003cp\u003eThe probe and meter automatically recognize the sensors that are connected.\u003c\/p\u003e\n\u003ch3\u003eData Logging\u003c\/h3\u003e\n\u003cp\u003eThe HI-98199 allows users to store up to 45,000 continuous or log-on-demand samples with logging intervals from one second to three hours.\u003c\/p\u003e\n\u003ch3\u003ePC Connectivity\u003c\/h3\u003e\n\u003cp\u003eLogged data can be transferred to a Window’s compatible PC with the included micro USB cable and Hanna software.\u003c\/p\u003e\n\u003ch3\u003eGLP Data\u003c\/h3\u003e\n\u003cp\u003eHI-98199 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers\/standards used for calibration, and slope characteristics.\u003c\/p\u003e\n\u003ch3\u003eDedicated Help Key\u003c\/h3\u003e\n\u003cp\u003eContextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting\/option being viewed.\u003c\/p\u003e\n\u003ch3\u003eLong Battery Life\u003c\/h3\u003e\n\u003cp\u003eThe meter displays a battery icon indicator to show the remaining power. The meter uses four 1.5V AA batteries that provide up to 360 hours of battery life.\u003c\/p\u003e\n\u003ch3\u003eVersatility when you need it\u003c\/h3\u003e\n\u003cp\u003eEach probe transmits readings digitally to the meter, where data points can be displayed and logged.\u003c\/p\u003e\n\u003ch3\u003eConductivity\u003c\/h3\u003e\n\u003cp\u003eThe HI-98199 allows for the measurement of conductivity, TDS (total dissolved solids), Resistivity, Salinity, seawater σ, and temperature when used with the optional HI-763093 digital EC probe.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-point calibration from six standards\u003c\/li\u003e\n\u003cli\u003eTemperature compensation Automatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eConfigurable temperature coefficient range from 0.00 to 6.00%\/°C\u003c\/li\u003e\n\u003cli\u003eChoice of reference temperatures at 20 or 25°C\u003c\/li\u003e\n\u003cli\u003eAbsolute conductivity can be displayed along with the temperature compensated value\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAuto-ranging\u003c\/h3\u003e\n\u003cp\u003eSalinity readings Practical Salinity Scale (PSU) based on conductivity calibration\u003c\/p\u003e\n\u003ch3\u003eDissolved Oxygen\u003c\/h3\u003e\n\u003cp\u003eThe HI-98199 allows for the measurement of dissolved oxygen, atmospheric pressure, and temperature when used with the optional HI-764103 digital DO probe.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay units in % saturation or ppm (mg\/L)\u003c\/li\u003e\n\u003cli\u003eSalinity compensation for saline waters Manual entry of salinity values\u003c\/li\u003e\n\u003cli\u003eReadings compensated for salinity effects\u003c\/li\u003e\n\u003cli\u003eBuilt-in barometer Automatic compensation for changes in atmospheric pressure\u003c\/li\u003e\n\u003cli\u003eUser selectable units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003epH \/ mV (using the included HI-829113 pH Probe)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH \/ ±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 pH \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH \/ ±0.5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic one, two, or three points of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eEC (using HI-763093 EC Probe – buy separately)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003emanual: 1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm; automatic: 1 μS\/cm from 0 to 9999 μS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 200.0 mS\/cm automatic mS\/cm: 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 200.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading or ±2 μS\/cm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic single point, with six standard solutions (84 μS\/cm, 1413 μS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTDS (using HI-763093 EC Probe - buy separately)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 200.0 ppt (g\/L) (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003emanual: 1 ppm (mg\/L); 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L); automatic: 1 ppm (mg\/L) from 0 to 9999 ppm (mg\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 200.0 ppt (g\/L) automatic ppt (g\/L): 0.001 ppt (g\/L) from 0.000 to 9.999 ppt (g\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 200.0 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 ppm (mg\/L) whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eResistivity (using HI-763093 EC Probe - buy separately)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Ω•cm; 0.1 kΩ•cm; 0.0001 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSalinity (using HI-763093 EC Probe – buy separately)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% of reading or ±0.01 PSU whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSeawater σ (using HI-763093 EC Probe – buy separately)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDissolved Oxygen (using HI-764103 DO Probe - buy separately)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0%; 0.00 to 50.00 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1%; 0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 ppm (mg\/L): ±1.5% of reading or ±0.10 ppm (mg\/L), whichever is greater; 30.00 ppm (mg\/L) to 50.00 ppm (mg\/L): ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic one or two points at 0, 100% or one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAtmospheric Pressure (using HI-764103 DO Probe – buy separately)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±3 mm Hg within ±15°C from the temperature during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01°C; 0.01°F; 0.01K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.15°C; ±0.27°F; ±0.15K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAdditional specifications\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temp compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic from -5 to 55°C (23 to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Logging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e45000 records (continuous logging or log-on-demand)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Logging Interval\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eone second to three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e PC Connectivity\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003evia USB (with Hanna PC software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Environment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Battery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 400 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Dimensions \/ Weight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e185.0 x 93.0 x 35.2 mm (7.3 x 3.6 x 1.4”) \/ 400 g (14.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-98199 is supplied with the HI-829113 pH digital probe with 4m (13’) cable, pH calibration solution sachets, PC software, micro USB cable, batteries, quality certificate, and instruction manual in a rugged carrying case.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProbes\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-829113 pH digital probe with 4m (13’) cable (supplied); HI-763093 EC digital probe with 4m (13’) cable (buy separately); HI-764103 DO digital probe with 4m (13’) cable (buy separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAccessories\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-710034 orange protective silicone rubber boot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":44386100117762,"sku":"HI-98199","price":877.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-98199-digital-ph-ec-do-portable-meter-with-hi-829113-ph-electrode.jpg?v=1710337708"}],"url":"https:\/\/testallwater.co.uk\/collections\/poultry-ec-conductivity-water-strength-testing.oembed","provider":"Test All Water","version":"1.0","type":"link"}