{"title":"Manufacturing and Processing","description":null,"products":[{"product_id":"hanna-instruments-4102-bromide-combination-ise-electrode","title":"Hanna Instruments-4102 Bromide Combination ISE Electrode","description":"The Hanna Instruments-4102 is ideal for a variety of applications in the pharmaceutical industry, laboratories, drinking water and wastewater treatment, food and beverage production, and in printing processes.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4102 bromide ion selective electrode is a complete potentiometric cell that contains a silver\/silver chloride (Ag\/AgCl) reference housed within a PEI plastic body with a potassium nitrate electrolyte. The internal elements are isolated from the sample by a compressed silver bromide sensing membrane.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna's solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFor the Hanna Instruments-4102 to measure bromide accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free bromide ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The Hanna Instruments-4102 bromide solid state ISE can measure from 1ÂµM (0.08 mg\/L) to 1M (79,910 mg\/L).\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354372976791,"sku":"HI-4102","price":940.41,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-4102_bromide_combination_ise_electrode_153bdf8a-36d2-4706-8fa5-3085e99a1acd.jpg?v=1624278755"},{"product_id":"hanna-instruments-83306-02-multi-parameter-environmental-analysis-photometer-with-ph-meter","title":"Hanna Instruments-83306-02 Multi-parameter Environmental Analysis Photometer with pH meter","description":"One meter can be used for both photometric and pH measurements. Hanna Instruments-83306 is a compact, multi-parameter photometer for use in the environmental lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 23 different programmed methods measuring 16 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. Environmental parameters include nitrate, phosphorous and dissolved oxygen.\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHanna Instruments-83306-02 Environmental Analysis Photometer with pH digital input \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe photometer features an innovative optical system that uses LEDs, narrow band interference filters, a focusing lens, and a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source which ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83306 was developed to measure the most common parameters in environmental water quality monitoring. Nutrients such as nitrates and phosphates are key indicators of nutrient pollution from agricultural sources and are considered dangerous to environmental waters. Too few nutrients and waters will be unable to sustain healthy ecosystems; too many nutrients and algal blooms can form, which can be detrimental to water quality and aquatic health. Dissolved oxygen is an essential to performing biological processes for many forms of aquatic life, such as fish, plants and microorganisms.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83306 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the four wavelengths of light (420 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability, the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eKey features: \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHigh Efficiency LED Light Source\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHigh Quality Narrow Band Interference Filters \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eReference Detector for a Stable Light Source \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eLarge Cuvette Size \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eFocusing Lens for Greater Light Yield \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354373075095,"sku":"HI-83306-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83306-02_multi-parameter_environmental_analysis_photometer_with_ph_meter_357082fd-4ba0-4d5e-8514-04ae70880382.jpg?v=1624278761"},{"product_id":"hanna-instruments-801-02-iris-spectrophotometer","title":"Hanna Instruments-801-02 Iris Spectrophotometer","description":"The Hanna Instruments-801 iris is a sleek and intuitive spectrophotometer that allows for measurement of all wavelengths of visible light.\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior design for superior results\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm.\u003c\/p\u003e\n\u003cp\u003eWith the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy. No need for measurement conversions Whether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-801 iris is a sleek and intuitive spectrophotometer that allows for measurement of all wavelengths of visible light.\u003c\/p\u003e\n\u003cp\u003eCustomise your methods, take a wide range of measurements, and feel confident in your testing accuracy with iris.\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eiris features precise wavelength selection between 340 nm to 900 nm for complete method compliance and accuracy that is necessary in industries like professional laboratories, water treatment facilities, wineries, and more.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eResults are consistent and accurate regardless of throughput with the high quality and uniquely designed optics system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCustomisation options include multiple cuvette shapes and sizes, custom calibration curves, and methods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354373271703,"sku":"HI-801-02","price":3340.01,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-801-02_iris_spectrophotometer_ae9cb400-8683-4282-b36b-666f4c257144.jpg?v=1624278769"},{"product_id":"hanna-instruments-93501p-thermistor-thermometer-with-probe","title":"Hanna Instruments-93501P Thermistor Thermometer with probe","description":"\u003cp\u003eFood service, food preparation, packaging, storage and transport of food require temperature to be monitored or controlled. Spot checking temperatures with Hanna food thermometers ensures daily work routines are carried out at the correct temperature.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eHanna Instruments-93501 is a thermistor style thermometer that includes a stainless steel replaceable style penetration probe (FC762PW). It measures temperatures from -50°C to 150°C.\u003c\/p\u003e\n\u003cp\u003eStandard features include waterproof casing (rated IP65) and stainless steel penetration probe designed for continuous contact with foodstuffs in accordance with regulations. Hanna Instruments-93501 also includes features such as CAL check, low battery detection, auto-off capability, and long battery life.\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e±0.1 °C\/ ±0.2 °F accuracy\u003c\/li\u003e\n\u003cli\u003eEnable automatic shut off after 8 minutes, 60 minutes, or disabled\u003c\/li\u003e\n\u003cli\u003ePerfect for spot checking of food in kitchens, BBQ's, and catering\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354374418583,"sku":"HI-93501P","price":106.97,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-93501p_thermistor_thermometer_with_probe_c2512a2c-4aa5-4fea-be14-bfeb7c949b44.jpg?v=1624278802"},{"product_id":"hanna-instruments-83303-02-aquaculture-multi-parameter-photometer-with-ph-meter","title":"Hanna Instruments-83303-02 AquaCulture Multi-parameter Photometer with pH Meter","description":"One meter can be used for both photometric and pH measurements. The meter has 20 different programmed methods measuring 12 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003cbr\u003e\u003ch3\u003eHanna Instruments-83303 Aquaculture Photometer with pH meter\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable benchtop space, the Hanna Instruments-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input. Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMade with the aquaculture industry in mind, the Hanna Instruments-83303 is a comprehensive solution to maintaining optimal chemical and environmental conditions, preventing disease and increasing production.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 measures vital parameters such as Alkalinity, Calcium, Nitrite, and Phosphate. Alkalinity plays a part in a dynamic relationship with pH and CO2 concentrations, high alkalinity water lowers fluctuations in pH. The buffering capacity acts to store extra CO2 essential for photosynthesis in the ponds to produce oxygen. Maintaining calcium at certain levels is vital to proper fish growth and development. Excessive nitrite can be toxic to fish. When nitrite interacts with Haemoglobin, the iron becomes oxidised and the blood cell can no longer carry oxygen. Phosphate is essential to plant growth; too much phosphate in an aquaculture system can contribute to algal blooms decreasing dissolved oxygen vital for a successful ecosystem.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83303 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375336087,"sku":"HI-83303-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_2_82e0c6fb-4e30-4e5b-9e18-bcb58add9261.jpg?v=1624278828"},{"product_id":"hanna-instruments-83300-02-multi-parameter-benchtop-photometer-ph-meter","title":"Hanna Instruments-83300-02 Multi-parameter Benchtop Photometer \u0026 pH meter","description":"One meter can be used for both photometric and pH measurements. The meter has 60 different programmed methods measuring 37 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83300 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003cbr\u003e\u003ch3\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-83300 is a compact, multi-parameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFrom Aluminium to Zinc, the Hanna Instruments-83300 benchtop photometer measures 37 water quality parameters using 60 different methods. The photometer features an innovative optical system that uses LEDs, narrow band interference filters, and a focusing lens. It also has a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83300 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375467159,"sku":"HI-83300-02","price":1489.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_3_dc75fef9-64f1-4563-8b90-e8a5f746505a.jpg?v=1624278832"},{"product_id":"hanna-instruments-1053b-ph-electrode-for-use-with-semi-solids","title":"Hanna Instruments-1053B pH Electrode for use with Semi-Solids","description":"The Hanna Instruments-1053B is a glass bodied refillable single junction combination pH electrode with a spear tip measuring tip and suitable for pH measurement of fats and creams, soil samples, semi solid product, low conductivity samples and emulsions.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-1053B is a glass bodied refillable single junction combination pH electrode with a spear tip.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eIdeal for\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFats or creams\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSoil samples\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSemi-solid products\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLow conductivity samples\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eEmulsions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eSupplied fitted with\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBNC connector\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e1m cable\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375663767,"sku":"HI-1053B","price":230.19,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-1053b_ph_electrode_for_use_with_semi-solids_259e5deb-41f9-4fa3-b617-d35cc8af8ebd.jpg?v=1624278834"},{"product_id":"hanna-instruments-98509-checktemp1-pocket-thermometer","title":"Hanna Instruments-98509 Checktemp1 Pocket Thermometer","description":"\u003cp\u003eChecktemp is a great choice for easy operation with clear digits and better accuracy over a wide range without fear of breakage or condensation.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"rangeOverview sub-range\"\u003e\n\u003cbr\u003e\n\u003ch3 class=\"range-heading\"\u003eHanna Instruments HI98509 Checktemp® 1 Pocket Digital Thermometer\u003c\/h3\u003e\n\u003cbr\u003e\n\u003cp class=\"range-paragraph\"\u003eThe Hanna Instruments HI98509 Checktemp® 1 pocket digital thermometer is a high-accuracy thermometer with a 1m long flexible silicone cable connecting the meter and the stainless steel probe. The sharp-tipped penetration probe easily lances semi-solid products such as fruits, vegetables and cheeses. This makes routine controls fast and simple for incoming and outgoing goods. The probe can also handle liquid, air and measurements in frozen materials, and incorporates a Negative Temperature Coefficient (NTC) thermistor sensor to measure the temperature. Applications of the HI98509 Checktemp® 1 pocket digital thermometer include education, laboratory and food industries (storage, transportation, manufacturing, cooling).\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp class=\"overViewList range-list\"\u003eOne of the world's most accurate temperature testers\u003cbr\u003eTemperature range -50 to +150 °C (-58 to +302 °F)\u003cbr\u003eResolution 0.1 °C (0.1 °F)\u003cbr\u003eAccuracy: ±0.3 °C (-20 to +90 °C), ±0.5 °C outside; ±0.5 °F (-4 to +194 °F), ±1 °F outside\u003cbr\u003eEnvironment -20 to +50 °C (-4 to +122 °F) RH maximum 95%\u003cbr\u003eCAL CHECK™ automatically verifies calibration at start-up\u003cbr\u003eUser selectable °C\/°F Status\u003cbr\u003eLarge display with wide environmental temperature range and viewing angle\u003cbr\u003eIP65 water resistant protection\u003cbr\u003eHazard Analysis and Critical Control Points (HACCP) compatible - can be used as a tool for control in HACCP analysis\u003cbr\u003eAuto-Off (select from 8 min, 60 min or turn the feature off)\u003cbr\u003eAISI 316 stainless steel probe 97.3 mm long x 3.5 mm diameter, with 1m long silicone cable\u003cbr\u003ePowered by 3 x 1.5V AAA batteries\u003cbr\u003eDimensions 107 x 59 x 16.5 mm\u003cbr\u003eWeight 80g\u003c\/p\u003e\n\u003cbr\u003e\n\u003cdiv class=\"range-tables\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 1.17em;\"\u003eSupplied with\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cp class=\"range-supplied-with\"\u003epenetration probe, silicone cable, batteries, instructions\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"rangeOverview line-drawing-images\"\u003e\u003cspan style=\"font-size: 1.17em;\"\u003eHandheld Pocket Temperature Indicators\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"rangeOverview line-drawing-images\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"rangeOverview line-drawing-images\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"heading divider-red\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" class=\"table table-striped\" style=\"width: 840px; height: 249px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"table-title\"\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Temperature Measurement\u003c\/td\u003e\n\u003ctd\u003e+150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermometer Type\u003c\/td\u003e\n\u003ctd\u003ePocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003eNTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCooking), Education, Food (Storage, Laboratory, Manufacturing, Transportation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 (-20 → +90 °C) °C, ±0.5 (Out Side) °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Temperature Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e58mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e19mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e106mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e58 x 19 x 106mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eAAA Alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Scale\u003c\/td\u003e\n\u003ctd\u003eCentigrade, Fahrenheit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e80g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number p\u003c\/td\u003e\n\u003ctd\u003eHI 98509\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375893143,"sku":"HI-98509","price":87.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-98509_checktemp1_pocket_thermometer_845f66f9-7007-4995-ba49-3e4f6c910a67.jpg?v=1624278853"},{"product_id":"hanna-instruments-96802-refractometer-for-fructose-0-to-85-scale","title":"Hanna Instruments-96802 Refractometer for Fructose 0 to 85% scale","description":"The Hanna Instruments-96802 measures the refractive index to determine the % fructose in aqueous solutions. The refractive index of the sample is converted to % mass (%w\/w) concentration units.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-98602 is used across the food industry for measuring the % fructose in foods.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eQuick and easy to use it is ideal for analysing the sugar content in a wide range of food products including fruit, energy drinks, puddings, tofu, jams, honey, soups and sauces.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003ePriced inexpensively does not mean a compromise on accuracy, the Hanna refractometer offers all the benefits of high precision digital technology at the same price as a mechanical model.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-96802 measures the refractive index to determine the % fructose in aqueous solutions. The refractive index of the sample is then converted to % by weight concentration units.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eProduct uses\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFruit growers and importers\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eFruit juice \u0026amp; drink manufacturers\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eProduction of jams, preserves \u0026amp; sauces\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eWhite water resistant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eEasy clean sample well\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eZero using pure water\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery operated with auto shut-off\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eMain benefits\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003e1.5 second measurement time\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDirect readout in % Brix and °C\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eNo calibration solutions required\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLarge clear LCD display\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354376188055,"sku":"HI-96802","price":323.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-96802_refractometer_for_fructose_0_to_85_scale_d9c1cb0c-8843-46d4-94cd-e7d4c40eb864.jpg?v=1624278856"},{"product_id":"hanna-instruments-83325-02-multi-parameter-photometer-with-ph-meter-for-plant-nutrient-analysis","title":"Hanna Instruments-83325-02 Multi-parameter Photometer with pH meter for Plant Nutrient analysis","description":"\u003cp\u003eOne meter can be used for both photometric and pH measurements. The Hanna Instruments-83325 benchtop photometer measures 8 different plant nutrient water quality parameters using 9 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time. Key parameters are: Ammonia, Calcium, Magnesium, Nitrate, Phosphorus, Potassium, Sulphate and pH.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eHanna Instruments-83325-02 Plant Nutrient Analysis Photometer with pH meter\u003c\/h3\u003e\n\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/p\u003e\n\u003cp\u003eConsistent and thorough monitoring of plant nutrients is essential to maintaining healthy growth and reproduction. This is easy with the Hanna Instruments-83325, a comprehensive way to monitor vital plant nutrients such as potassium, calcium and magnesium. Required in large quantities, potassium plays a vital role in water uptake and enzyme regulation. Calcium helps to strengthen plant cell walls protecting against heat stress while magnesium helps build a strong immune system.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83325 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the three wavelengths of light (420 nm, 466 nm, and 525 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch3\u003eKey features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cli\u003eError Messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354376482967,"sku":"HI-83325-02","price":853.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_4_244ef4df-8e10-4227-a272-550e2bc9fb4e.jpg?v=1624278870"},{"product_id":"hanna-instruments-99162-portable-ph-temperature-meter-for-milk-analysis","title":"Hanna Instruments-99162 Portable pH\/Temperature Meter for Milk Analysis","description":"The Hanna Instruments-99162 is a portable pH and temperature meter designed specifically for milk analysis.\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-99162 is a portable pH and temperature meter designed specifically for milk analysis.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThis meter is supplied with the FC101D pH electrode with internal temperature sensor. The FC101D is composed of food grade PVDF plastic and has a spheric tip providing a large surface area for contact with milk samples. The construction of this electrode provides accurate measurements both on the dairy farm and production facility.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eHanna Instruments-99162 features automatic calibration at one or two points with two sets of buffers. All calibrations and measurements are automatically compensated for temperature variations due to the internal temperature sensor in the FC101D electrode.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThe split-level LCD displays both pH and temperature readings, along with indicators for reading stability, battery percentage, and calibration instructions.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section four\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003cbr\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eApplication specific electrode\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAutomatic temperature compensation (ATC)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eStability indicator for accurate data recording\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eApplication importance\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003eThe measurement of pH in milk is important in testing for impurities, spoilage, and signs of mastitis infection. While there are a number of factors that affect the composition of milk, pH measurements can help producers understand what might be causing certain compositional changes. pH measurements are commonly performed at various points in a milk processing plant.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eFresh milk has a pH value of 6.7. When the pH value of the milk falls below pH 6.7, it typically indicates spoilage by bacterial degradation. Bacteria from the family of Lactobacillaceae are lactic acid bacteria (LAB) responsible for the breakdown of the lactose in milk to form lactic acid. Eventually when the milk reaches an acidic enough pH, coagulation or curdling will occur along with the characteristic smell and taste of 'sour' milk.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eMilk with pH values higher than pH 6.7 potentially indicate that the milk may have come from cows infected with mastitis.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eMastitis is an ever-present challenge with dairy milking cows. When infected, the cow's immune system releases histamine and other compounds in response to the infection. There is a resulting increase in permeability of endothelial and epithelial cell layers, allowing blood components to pass through a paracellular pathway. Since blood plasma is slightly alkaline, the resulting pH of milk will be higher than normal. Typically milk producers can perform a somatic cell count to detect a mastitis infection, but a pH measurement offers a quick way to screen for infection.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eUnderstanding the pH of raw milk can also help producers optimise their processing techniques. For example, in operations that use Ultra High Temperature (UHT) processing, even small variations from pH 6.7 can affect the time required for pasteurisation and stability of the milk after treatment.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354376614039,"sku":"HI-99162","price":630.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-99162_portable_phtemperature_meter_for_milk_analysis_64ff2b9a-4218-4cfb-a4a7-50103175c8e7.jpg?v=1624278880"},{"product_id":"hanna-instruments-83308-water-conditioning-photometer-with-ph-meter","title":"Hanna Instruments-83308 Water Conditioning Photometer with pH meter","description":"\u003cp\u003eOne meter can be used for both photometric and pH measurements. This meter has 23 different programmed methods measuring 15 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. Water conditioning parameters include Fluoride, Chlorine, Ammonia, Manganese, Copper, Iron, Silver and Zinc.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 benchtop photometer measures 15 different key water quality parameters using 23 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 was developed to measure the most common parameters in water quality monitoring. One important parameter to test water quality is iron since it can affect colour, odour, and turbidity and can also be the most troublesome factor for appliances and surfaces in contact with water. High levels of iron in water can result in clogged water pipes or heat exchangers.\u003c\/p\u003e\n\u003cp\u003eAdditionally, Ammonia detection in water treatment systems is particularly important for aquarium owners and fish farm operators since ammonia is highly soluble in water and extremely toxic to fish. One other important parameter in water quality monitoring is Fluoride. Fluoride is best known for preventing tooth decay. While it does help prevent tooth decay, too little fluoride can be ineffective while too much can cause staining of teeth.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the four wavelengths of light (420 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch3\u003eKey features:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eError Messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Focusing Lens for Greater Light Yield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\n\u003cdiv id=\"product_tabs\" class=\"product__tabs\"\u003e\n\u003cdiv class=\"tabs\"\u003e\n\u003cdiv class=\"tab specification active\"\u003e\n\u003cdiv class=\"tab__content\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pH electrode input and 4 photometer wavelengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital pH electrode (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLog on demand with user name and sample ID optional input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-A host for flash drive; micro-USB-B for power and computer connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibration data for connected pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 VDC Li-polymer rechargeable battery\/ \u0026gt;500 photometric measurements or 50 hours of continuous pH measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e206 x 177 x 97mm (8.1 x 7.0 x 3.8\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon Photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e8nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter wavelength accruacy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e+-1nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRound, 24.6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Methods\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-83308 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAMMONIA\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 3.00 mg\/L (as NH3-N) Medium Range: 0.00 to 10.00 mg\/L (as NH3-N) High Range: 0.0 to 100.0 mg\/L (as NH3-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading Medium Range: ±0.05 mg\/L ±5% of reading High range: ±0.5 mg\/L ±5% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCHLORINE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA 330.5 DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCOPPER\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.500 mg\/L (as Cu2+) High range: 0.00 to 5.00 mg\/L (as Cu2+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±5% of reading High Range ±0.02 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFLUORIDE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as F-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIRON\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.600 mg\/L (as Fe) High Range: 0.00 to 5.00 mg\/L (as Fe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±8% of reading High Range: ±0.04 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the TPTZ Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMANGANESE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 300 µg\/L (as Mn) High range: 0.0 to 20.0 mg\/L (as Mn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.02 mg\/L ±3% of reading; High Range: ±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMOLYBDENUM\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 40.0 mg\/L (as Mo6+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the mercaptoacetic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNICKEL\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.000 mg\/L (as Ni); High Range: 0.00 to 7.00 g\/L (as Ni)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow range: ±0.010 mg\/L ±7% of reading High Range: ±0.07 g\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN method; High Range: Adaptation of the photometric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNITRATE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L (as NO3-- N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±10% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the cadmium reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOXYGEN, DISSOLVED\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L (as O2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.4 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003epH\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 0.1 pH pH electrode: 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: ±0.1 pH pH electrode: ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eclean electrode and check buffer\/check probe displayed during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: phenol red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePHOSPHATE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.50 mg\/L (as PO43-) High range: 0.0 to 30.0 mg\/L (as PO43-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading High Range: ±1 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the Ascorbic Acid method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSILICA\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as SiO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSILVER\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.000 mg\/L (as Ag)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.020 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the PAN method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eZINC\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.00 mg\/L (as Zn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eREAGENTS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia HR, MR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93733-01 (100 tests); HI-93733-03 (300 tests); MR - HI-93715-01 (100 tests); HI-93715-03 (300 tests); LR - HI-93700-01 (100 tests); HI-93700-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine - Free\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Total\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)\u003cbr\u003eChlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93702-01 (100 tests); HI-93702-03 (300 tests)\u003cbr\u003eLR - HI-95747-01 (100 tests); HI-95747-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93739-01 (100 tests); HI-93739-03 (300 tests)\u003cbr\u003eLR - HI-93729-01 (100 tests); HI-93729-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93721-01 (100 tests); HI-93721-03 (300 tests)\u003cbr\u003eLR - HI-93746-01 (100 tests); HI-93746-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93709-01 (100 tests); HI-93709-03 (300 tests)\u003cbr\u003eLR - HI-93748-01 (50 tests); HI-93748-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93730-01 (100 tests); HI-93730-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel - HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93726-01 (100 tests); HI-93726-03 (300 tests)\u003cbr\u003eLR - HI-93740-01 (50 tests); HI-93740-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93728-01 (100 tests); HI-93728-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved (DO)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93732-01 (100 tests); HI-93732-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93710-01 (100 tests); HI-93710-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate - HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93717-01 (100 tests); HI-93717-03 (300 tests)\u003cbr\u003eLR - HI-93713-01 (100 tests); HI-93713-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica – LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLR - HI-93705-01 (100 tests); HI-93705-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93737-01 (50 tests); HI-93737-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93731-01 (100 tests); HI-93731-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354377793687,"sku":"HI-83308-02","price":717.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83308_water_conditioning_photometer_with_ph_meter_65bd256c-bf7f-4276-8991-38095b909212.jpg?v=1624278907"},{"product_id":"hanna-instruments-83305-02-multi-parameter-photometer-ph-meter-for-boiling-and-cooling-towers","title":"Hanna Instruments-83305-02 Multi-parameter Photometer \u0026 pH Meter for Boiling and Cooling towers","description":"One meter can be used for both photometric and pH measurements. The meter has 30 different programmed methods measuring 18 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves.\u003cbr\u003e\u003ch3\u003eHanna Instruments-83305-02 Boiler and Cooling Tower Photometer with pH digital input\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable benchtop space, the Hanna Instruments-83305 doubles as a professional pH meter with its digital pH\/temperature electrode input. Suitable for use in boiling and cooling tower applications, parameters specific to boiling and cooling towers include oxygen scavengers and silica which are important for maintaining equipment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable laboratory benchtop space, the Hanna Instruments-83305 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis photometer features an innovative optical system that uses LEDs, narrow band interference filters, a focusing lens, plus a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source which ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eSpecifically designed for use with boilers and cooling towers, the Hanna Instruments-83305 is a comprehensive way to maintain precise water conditions in systems. Problems such as corrosion, deposition, and microbial growth can occur if these key parameters, such as oxygen scavengers and silica, aren't maintained. Oxygen scavengers are added to remove residual dissolved oxygen in boiler feed water that can cause corrosion in a steam generating plant. It is important that levels of oxygen scavengers be routinely checked to prevent against corrosion and ensure that equipment is working efficiently. Boiler water maintenance is necessary to prevent or control deposit formation as seen with silica. Silica contamination can reduce system efficiency and increase maintenance of equipment due to scaling.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built-in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built-in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83305 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability, the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354378645655,"sku":"HI-83305-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83305-02_multi-parameter_photometer_ph_meter_for_boiling_and_cooling_towers_181f2f4b-06e5-4b51-9be1-abf10313a96a.jpg?v=1624278958"},{"product_id":"hanna-instruments-83749-02-portable-turbidity-meter-and-bentonite-monitoring","title":"Hanna Instruments-83749-02 Portable Turbidity Meter and bentonite monitoring","description":"The portable turbidity meter and bentonite monitoring system measures turbidity of samples from 0.00 to 1200 NTU (Nephelometric Turbidity Units) and is USEPA compliant. Wines with low phenol contents, such as rose, light reds and whites should be checked for protein stability before bottling.\u003cbr\u003e\u003ch3\u003eHanna Instruments-83749-02 Portable Turbidity Meter\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eWines with low phenol contents, such as rose, light reds and whites should be checked for protein stability before bottling. Hanna offers a quick test meter to verify the risk of future protein haze formation. If protein instability is detected, a subsequent test can help define the right amount of bentonite to be added for improving protein stability. It is important not to overdose bentonite to avoid stripping wine flavour, body and significant loss of colour, especially in young red wines.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMoreover, adding only the necessary amount of bentonite to obtain the desired protein stability also saved costs.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83749 measures turbidity of samples from 0.00 to 1200 NTU (Nephelometric Turbidity Units) and is USEPA compliant. In the USEPA measurement mode the instrument rounds the readings to meet USEPA reporting requirements.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOther features include:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eGLP features\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit LCD\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003ePC Interface via USB\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eFast Tracker™\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83749 is equipped with Fast Tracker™ Tag Idenfication System (TIS) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of specific measurement or series of measurements using iButton® tags near sampling points for quick and easy readings. Each iButton® tag contains a computer chip with a unique identification code encased in stainless steel\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354379268247,"sku":"HI-83749-02","price":1447.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83749-02_portable_turbidity_meter_and_bentonite_monitoring_b504e5ec-928a-4613-ae63-d9e10a3dcbe2.jpg?v=1624278976"},{"product_id":"hanna-instruments-7871-220-mini-level-controller-control-relay-high-and-low-220v","title":"Hanna Instruments-7871\/220 Mini Level Controller, control relay: high and low, 220V","description":"Hanna Instruments-7871 mini-level controller is ideal for liquid level control over distances of up to 100 meters (330 feet). It is highly compact and will fit in tight spaces.\u003cbr\u003e\u003ch3\u003eMini Level Controller, control relay: high and low, 220, 240V\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThese easy-to-use controllers are ideal for nearly any liquid level application, such as industrial and municipal water treatment, nutrient tank control in farming, hydroponics, aquaculture applications and plating rinse baths.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-7871 includes an overflow alarm and can be connected to a 2-wire transmitter, which is ideal for level monitoring in remote applications.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA complete liquid level measuring system requires:\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eController (Hanna Instruments-7871)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003ebar holder with amplifier circuitry (Hanna Instruments-7874)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eMeasuring bars (Hanna Instruments-731324)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUndecal connector (Hanna Instruments-7164)\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-7871 requires four bars with the additional bar used for overflow measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information:\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-7871 is supplied with mounting brackets and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354380480663,"sku":"HI-7871\/220","price":127.78,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-787120_mini_level_controller_control_relay_high_and_low_220v.jpg?v=1624279023"},{"product_id":"hanna-instruments-943500d-conductivity-controller-low-range-199-9-µs-cm","title":"Hanna Instruments-943500D Conductivity Controller (Low Range @ 199.9 µS\/cm)","description":"Hanna Instruments-943500 are panel-mounted conductivity controllers designed for simplicity of use in a wide range of industrial process applications. Four different models are available with different measurement ranges, to satisfy any application requirements.\u003cbr\u003e\u003cp\u003eFour different models are available with different measurement ranges, to satisfy any application requirements.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe output configuration for connecting a recorder or a PLC can be chosen between 0-20 or 4-20 mA.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe LED on the front panel indicates the operating status of the controller.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe automatic temperature compensation (ATC) is performed directly by the Hanna Instruments-7638 probe with built-in temperature sensor.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe front panel is protected behind a transparent splash-proof cover.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information:\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-943500 series is supplied with mounting brackets and instructions.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500A: 0.0 to 199.9 mS\/cm\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500B: 0.00 to 19.99 mS\/cm\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500C: 0 to 1999 µS\/cm\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHanna Instruments-943500D: 0.0 to 199.9 µS\/cm\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354380578967,"sku":"HI-943500D","price":756.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-943500d_conductivity_controller_low_range_199.9_scm_0a23d3d4-993d-4a95-8dd7-77731bc238f0.jpg?v=1624279024"},{"product_id":"hanna-instruments-3887-free-chlorine-and-ph-test-kit","title":"Hanna Instruments-3887 Free Chlorine and pH Test Kit","description":"Chlorine is the most commonly used water disinfectant in applications that vary from treatment of drinking water and wastewater, pools and spas sanitisation, to food processing and sterilisation.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-3887 is a chemical test kit for testing Free Chlorine and pH.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFree chlorine reacts with ammonium ions and organic compounds to form chlorine compounds resulting in diminished disinfecting capabilities compared with free chlorine. These chlorine compounds together with chloramines form combined chlorine. Combined chlorine and excess free chlorine together result in total chlorine. While free chlorine has a much higher disinfectant potential, combined chlorine has a much higher stability and has a lesser volatility. There should be sufficient levels of unreacted free chlorine for adequate disinfection, but not so much as to become harmful.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-3887 test kit comes with colour comparison cubes (2), 20 mL reagent 1, 15 mL reagent 2, 25 mL Hanna Instruments-3881-0 pH 6.0-8.5 reagent\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354382708887,"sku":"HI-3887","price":57.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hanna_instruments_3887_free_chlorine_ph_test_kit.jpg?v=1624279068"},{"product_id":"hanna-instruments-935002-2-channel-k-type-thermocouple-thermometer","title":"Hanna Instruments-935002 2-Channel K-Type Thermocouple Thermometer","description":"HI 935002 and HI 935009 are waterproof 2-channel thermometers offering a wide temperature range and an extraordinary 1600 hours of battery life ideal for extended lab and field use.\u003cbr\u003e\u003ch3\u003e2-Channel, K-Type Thermocouple Thermomete\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-935002 is a 2-channel, water resistant, K-type thermometer that offers accurate temperature measurements in a wide range as well as 1600 hours of battery life.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis unit displays current temperature along with the minimum and maximum for each channel achieved during the measuring session. The difference between each channel can be shown, or a relative value can be set on each channel and variances around that value can be monitored.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis instrument is equipped with BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eDual input channels\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eOne point calibration\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eWater resistant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUp to 1600 battery life\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eReading storage\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eSupplied with\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eInstructions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354382905495,"sku":"HI-935002","price":214.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-935002_2-channel_k-type_thermocouple_thermometer_ce2167b3-8517-433c-9e1a-04f0c11f5921.jpg?v=1624279073"},{"product_id":"fc400b-foodcare-heavy-duty-ph-electrode-for-meat-applications-1","title":"FC400B Foodcare Heavy Duty pH Electrode for Meat Applications","description":"The design is ideal for pH measurements in products such as meats and semi-frozen food products. The recommended operating temperature range is from 0 to 50°C.\u003cbr\u003e\u003ch3\u003eFC400B Foodcare Heavy Duty pH Electrode for Meat Applications\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe FC400B electrode design consideration is ideal for pH measurements in products such as meats and semi-frozen food products. The recommended operating temperature range is from 0 to 50°C.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe main body of the electrode is covered in PVDF which is both easy to clean and food safe.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe FC400B has a double junction and a BNC connector, plus a 1 metre cable. The FC400B electrode features an open junction design with viscolene gel electrolyte, a sensing bulb made of low temperature glass, and a conical tip shape.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimised. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate forming to clog the junction.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354383069335,"sku":"FC400B","price":240.64,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/fc400b_foodcare_heavy_duty_ph_electrode_for_meat_applications_af16bd2a-a7bc-402c-8c43-67ec4355c865.jpg?v=1624279074"},{"product_id":"hanna-instruments-93531-waterproof-k-type-thermocouple-thermometer","title":"Hanna Instruments-93531 Waterproof K-Type Thermocouple Thermometer","description":"These thermometers can read with a resolution of 0.1 in the range of -149.9 to 999.9°C or -24.9 to 999.9°F. The meters are equipped with a HOLD function that freezes the current reading on the display. A °C\/°F button will change between Celsius and Fahrenheit modes. Battery level is shown at startup and low battery warning with Battery Error Prevention System (BEPS) assure long periods of trouble-free use between battery changes.\u003cbr\u003e\u003ch3\u003e0.1° Resolution K-Type Thermocouple Thermometer\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe HI 93531 is a K-type water resistant thermometer that features 0.1° resolution in the -149.9 to 999.9°C range, making it ideal for precise temperature measurements. This instrument displays the current temperature along with the minimum and maximum extremes achieved.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe HOLD button freezes the display to allow the user time to record readings. The °C\/°F button switches between the Celsius and Fahrenheit temperature scale. The CLEAR button restarts the evaluation of high and low values.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis instrument is equipped with BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eOne point calibration\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eWater resistant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHigh\/Low function\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e°C to °F shifting\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHOLD function\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBEPS and low battery warning\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery life indicator at start-up\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAuto-off capability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklight display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eReading storage\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eSupplied with\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBatteries and instructions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354383757463,"sku":"HI-93531","price":250.04,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-93531_waterproof_k-type_thermocouple_thermometer_5bce0ddb-68c9-4ab4-ad1d-36167847c44b.jpg?v=1624279095"},{"product_id":"fc230b-food-ph-electrode-for-use-with-fc099-knife-adaptor-1","title":"FC230B Food pH Electrode for use with FC099 Knife Adaptor","description":"The Hanna FC230B features a white foodgrade PTFE spear body with the ability to attach 2 different length knife blades for the measurement of meat products.\u003cbr\u003e\u003cp\u003eThe FC230B features a white food grade PTFE spear body and has the ability to attach two different knife blades for the pH measurement of meat products.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis electrode is supplied complete with a 1m white food cable and standard fit BNC connector allowing it to be used on most types of pH meter.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354386018455,"sku":"FC230B","price":294.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/fc230b_food_ph_electrode_for_use_with_fc099_knife_adaptor_ee2609d0-784b-425a-9d53-79360edcba83.jpg?v=1624279116"},{"product_id":"bl-983320-0-conductivity-mini-controller-range-199-9-µs-cm","title":"Hanna Instruments Conductivity Mini Controller (Range 199.9 µS\/cm) BL-983320-0","description":"The Hanna mini controllers have been specially designed for water conditioning and growing applications. The BL-983320 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0.0 to 199.9 μS\/cm range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. Compact in size, they can be mounted in confined spaces or even right next to the vat or barrel containing the chemicals.\u003cbr\u003e\n\u003cp\u003eWhen in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionised) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL-983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.\u003c\/p\u003e\n\u003ch3\u003eAdjustable Dry Contact Dosing Relay\u003c\/h3\u003e\n\u003cp\u003eThe BL-983320 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch3\u003eProgrammable Overdose Protection\u003c\/h3\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch3\u003eRelay Control Override\u003c\/h3\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch3\u003eMulticolour LED Indicator\u003c\/h3\u003e\n\u003cp\u003eMulticolour LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFuse Protected Dosing Contacts\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLabelled Termination Connections\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQuick-connect terminal blocks are clearly labelled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe BL-983320 mini controller uses the HI-7634-00 conductivity probe that is available with different cable lengths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*HI-7634-00 is not included and must be ordered separately\u003c\/p\u003e\n\u003ch3\u003eOrder Information:\u003c\/h3\u003e\n\u003cp\u003eThe BL-983320 is supplied with mounting brackets, transparent cover, and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354386411671,"sku":"BL-983320-0","price":231.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983320-0_conductivity_mini_controller_range_199.9_scm_f2017210-2133-4214-a3fa-72bca529132b.jpg?v=1624279134"},{"product_id":"hanna-instruments-4111-iodine-combination-electrode","title":"Hanna Instruments-4111 Iodine Combination Electrode","description":"The Hanna Instruments-4111 is ideal for a variety of applications in food production and environmental monitoring.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4111 iodide selective electrode is a complete potentiometric cell that contains a silver\/silver chloride (Ag\/AgCl) reference housed within a PEI plastic body with a potassium nitrate electrolyte. The internal elements are isolated from the sample by a compressed silver iodide sensing membrane.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna’s solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFor the Hanna Instruments-4111 to measure iodide accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free iodide ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The Hanna Instruments-4111 iodide solid state ISE can measure from 0.1µM (0.01 mg\/L) to1M (127,000 mg\/L).\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354386772119,"sku":"HI-4111","price":940.41,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-4111_iodine_combination_electrode_2aeb85d0-6cb3-48a0-95e8-ca6abc2cb268.jpg?v=1624279152"},{"product_id":"hanna-instruments-83303k-aquaculture-photometer-kit","title":"Hanna Instruments-83303K Aquaculture Photometer kit","description":"\u003cp\u003e\u003cstrong\u003eHanna Instruments-83303K Aquaculture Photometer Kit\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eKit contains:\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eHI 83303-02 - meter\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93700-01 - ammonia tests x 100\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93732-01 - dissolved oxygen tests x 100\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93710-01 - pH tests x 100\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93728-01 - nitrate tests x 50\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93707-01 - nitrite tests x 50\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 740222N - blue carrying case\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eOne meter can be used for both photometric and pH measurements. The meter has 20 different programmed methods measuring 12 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input. Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMade with the aquaculture industry in mind, the Hanna Instruments-83303 is a comprehensive solution to maintaining optimal chemical and environmental conditions, preventing disease and increasing production.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 measures vital parameters such as Alkalinity, Calcium, Nitrite, and Phosphate. Alkalinity plays a part in a dynamic relationship with pH and CO2 concentrations, high alkalinity water lowers fluctuations in pH. The buffering capacity acts to store extra CO2 essential for photosynthesis in the ponds to produce oxygen. Maintaining calcium at certain levels is vital to proper fish growth and development. Excessive nitrite can be toxic to fish. When nitrite interacts with Haemoglobin, the iron becomes oxidised and the blood cell can no longer carry oxygen. Phosphate is essential to plant growth; too much phosphate in an aquaculture system can contribute to algal blooms decreasing dissolved oxygen vital for a successful ecosystem.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHigh Efficiency LED Light Source\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHigh Quality Narrow Band Interference Filters\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eReference Detector for a Stable Light Source\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eLarge Cuvette Size\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83303 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eFocusing Lens for Greater Light Yield\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354386903191,"sku":"HI-83303K","price":913.24,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83303k_aquaculture_photometer_kit_4005254e-d1f0-4bd5-aba5-9872d22dd173.jpg?v=1624279156"},{"product_id":"hanna-instruments-98161-general-purpose-foodcare-ph-and-temperature-meter","title":"Hanna Instruments-98161 General Purpose Foodcare pH and Temperature meter","description":"\u003cp\u003eThe Hanna Instruments-98161 is a rugged, waterproof, portable pH meter that measures pH and temperature using the specialised FC2023 Foodcare pH electrode.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003ehe Hanna Instruments-98161 is a rugged, waterproof, portable pH meter that measures pH and temperature using the specialised FC2023 Foodcare pH electrode. This professional, waterproof meter complies with IP67 standards. The Hanna Instruments-98161 is supplied with all necessary accessories to perform a pH\/temperature measurement packaged into a durable thermoformed carrying case that holds the meters, probes and calibration buffers securely in place.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWaterproof - The professional meter is IP67 rated.\u003c\/li\u003e\n\u003cli\u003eCAL Check™ - Alerts users to problems.\u003c\/li\u003e\n\u003cli\u003eAutomatic or manual temperature compensation.\u003c\/li\u003e\n\u003cli\u003eCalibration.\u003c\/li\u003e\n\u003cli\u003e200 hour battery life approximately with 1.5V AA batteries (x4) .\u003c\/li\u003e\n\u003cli\u003eClear display.\u003c\/li\u003e\n\u003cli\u003eAuto hold.\u003c\/li\u003e\n\u003cli\u003eCalibration timeout.\u003c\/li\u003e\n\u003cli\u003ePC Connectivity via USB.\u003c\/li\u003e\n\u003cli\u003eGLP.\u003c\/li\u003e\n\u003cli\u003eIntuitive keypad.\u003c\/li\u003e\n\u003cli\u003eCarry case and accessories.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354387132567,"sku":"HI-98161","price":893.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-98161_general_purpose_foodcare_ph_and_temperature_meter_63cf425f-817c-4d1a-984d-4d764a83dc33.jpg?v=1624279174"},{"product_id":"hanna-instruments-98308-pure-water-test","title":"Hanna Instruments-98308 Pure Water Test","description":"The Hanna Pure Water Test (PWT) enables you to check the purity of your distilled or demineralised water in laboratory or industrial environments.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-98308 Pure Water Test (PWT) enables users to check the purity of your distilled or demineralised water in laboratory or industrial environments.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis water purity test is suited for fields such as printed circuit board washing, laundry, steam cleaning, checking car battery water and all areas where distilled, demineralised or pure water is used.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-98308 is housed in a durable case that provides excellent protection against harsh industrial environments. \u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eExposed temperature probe for fast response\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGraphite sensors for reduced polarisation\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eReplaceable probes\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e0.1 µS\/cm resolution\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eSupplied with\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCalibration screwdriver\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eInstructions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354387361943,"sku":"HI-98308","price":123.79,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-98308_pure_water_test_935cbf6d-352a-4d18-87ea-0beac3caf8ab.jpg?v=1624279182"},{"product_id":"hanna-instruments-146-00-wall-mounting-precision-thermometer-with-calcheck®","title":"Hanna Instruments-146-00 Wall-mounting Precision Thermometer with CalCheck®","description":"The Hanna Instruments-146-00 is a high accuracy compact food thermometer designed to be mounted on a wall with a 2m cable sensor.\u003cbr\u003e\u003ch3\u003eall-mounting precision thermometer, °C\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-146-00 is a high accuracy thermometer with a professional grade probe and a flexible 2 m cable.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe CAL CHECK® feature is incorporated into its function to allow you to confirm the accuracy of the meters any time. You can monitor the exact temperature of any product continuously and easily observe it on the LCD display.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-146-00 can be easily carried from station to station or installed in a fixed position using the moulded eye and a wall mount probe holder.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eWith its compact and simplified design featuring a fixed stainless steel probe and optional probe holder, this thermometer is ideal for monitoring the temperatures of liquids, semi-solids and refrigerated foods.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eHACCP compliant\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL CHECK® feature\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eStainless steel temperature probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eWater resistant\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eSupplied with\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eStainless steel temperature probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eInstructions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354389328023,"sku":"HI-146-00","price":114.38,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-146-00_wall-mounting_precision_thermometer_with_calcheck_2320cbc8-c8b8-40f9-87f6-bba4d4a88d83.jpg?v=1624279241"},{"product_id":"hanna-instruments-766z-k-type-thermocouple-wire-probe-for-ovens-1-7m-cable","title":"Hanna Instruments-766Z K-Type Thermocouple Wire Probe for Ovens, 1.7m cable","description":"The Hanna Instruments-766PX series are K-type thermocouple temperature probes to be used with thermocouple thermometers – ideal for industrial situations where very high temperatures are expected. All probes in the Hanna Instruments-766 series are made from stainless steel for long life and easy cleaning. The series includes a wide range of probes for measurement of liquids, air, gas and penetration in semi-solids, as well as curved, planed or hard-to-reach surfaces. In addition, models are available with interchangeable or fixed handles for maximum versatility.\u003cbr\u003e\u003ch3\u003eHanna Instruments-766Z Wire Temperature Probe\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eWire probe designed to measure temperature ovens\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354390343831,"sku":"HI-766Z","price":97.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-766z_k-type_thermocouple_wire_probe_for_ovens_1.7m_cable_d18e2c4b-c2f4-42f0-a9ef-2c24aaefa5e1.jpg?v=1624279243"},{"product_id":"hanna-instruments-3827-boiler-feedwater-test-kit-for-6-parameters","title":"Hanna Instruments-3827 Boiler feedwater test kit for 6 parameters","description":"\u003cp\u003eThis combination test kit is supplied in a rugged case and contains all that you need to test Alkalinity, Chloride, Hardness, pH, Phosphate and Sulphite.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eBoiler and Feedwater Combination Test Kit\u003c\/h3\u003e\n\u003cp\u003eThe Hanna Instruments-3827 boiler and feedwater chemical test kit measures 6 main parameters; alkalinity, chloride, hardness, pH, phosphate and sulphite\u003c\/p\u003e\n\u003cp\u003eAll the tests are performed with a titration method except for the pH test. pH is obtained with Hanna's pHep®, pH electronic tester which guarantees greater accuracy and a longer life than traditional litmus paper.\u003c\/p\u003e\n\u003cp\u003eThis kit is equipped with all the necessary reagents and equipment to perform over 100 tests (50 for phosphate). All tests are easy to perform with step-by-step instructions and the kit is supplied with a rugged portable carrying case for transportation.\u003c\/p\u003e\n\u003ch3\u003eSignificance of use\u003c\/h3\u003e\n\u003cp\u003eMonitoring the alkalinity, chloride, hardness, phosphate, pH, and sulphite concentrations in boiler and feedwater is essential in preventing hazardous or costly situations.\u003c\/p\u003e\n\u003cp\u003eThese parameters are important in determining the corrosive characteristics of water due to carbonates and chloride.\u003c\/p\u003e\n\u003cp\u003eSulphite is critical to prevent pitting and oxidation of metal components. A high level of sulphite results in a lowered pH, which can also promote corrosion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAlkalinity (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100mg\/L (ppm)\u003cbr\u003e0-300 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1mg\/L (ppm)\u003cbr\u003e3mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein\/bromphenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e110 avg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eChloride (as Cl\u003csup\u003e-\u003c\/sup\u003e)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100mg\/L (ppm)\u003cbr\u003e0-1000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1mg\/L (ppm)\u003cbr\u003e10mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e110 avg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHardness (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0-30.0mg\/L (ppm)\u003cbr\u003e0-300 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3mg\/L (ppm)\u003cbr\u003e3mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eEDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e100 avg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePhosphate (as PO\u003csup\u003e3-\u003c\/sup\u003e\u003csub\u003e4\u003c\/sub\u003e)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eColorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0-5mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAscorbic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e50 avg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003epH\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic pH tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0-14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003epH tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLife of the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSulphite (as Na\u003csub\u003e2\u003c\/sub\u003eSO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 – 20.0 mg\/L (ppm)\u003cbr\u003e0-200 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Smallest increment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2mg\/L (ppm)\u003cbr\u003e2 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Number of tests\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e110 avg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e440 x 330 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOrdering Information\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-3827 test kit includes all of the necessary reagents and accessories to perform over 100 tests for every parameter, with the exception of phosphate, which includes reagents for 50 tests, hard carrying cases and instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eReplacement Reagents\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-3811-100 Alkalinity (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003cbr\u003eHI-3815-100 Chloride, 110 tests\u003cbr\u003eHI-3812-100 Hardness, total (as CaCO\u003csub\u003e3\u003c\/sub\u003e) 100 tests\u003cbr\u003eHI-3833-050 Phosphate, 50 tests\u003cbr\u003eHI-3810-100 Dissolved Oxygen, 110 tests\u003cbr\u003eHI-3822-100 Sulphite (as Na\u003csub\u003e2\u003c\/sub\u003eSO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354393718935,"sku":"HI-3827","price":358.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-3827_boiler_feedwater_test_kit_for_6_parameters_d602b166-7cb5-472b-9120-842ae966049b.jpg?v=1624279344"},{"product_id":"hanna-instruments-766tv1-k-type-thermocouple-pipe-clamp-probe-1m-cable","title":"Hanna Instruments-766TV1 K-Type Thermocouple Pipe Clamp Probe, 1m cable","description":"The Hanna Instruments-766PX series are K-type thermocouple temperature probes to be used with thermocouple thermometers – ideal for industrial situations where very high temperatures are expected. All probes in the Hanna Instruments-766 series are made from stainless steel for long life and easy cleaning. The series includes a wide range of probes for measurement of liquids, air, gas and penetration in semi-solids, as well as curved, planed or hard-to-reach surfaces. In addition, models are available with interchangeable or fixed handles for maximum versatility.\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-766TV1 is a K-Type Thermocouple pipe clamp probe with 1 m cable.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThis probe is suitable for use with any K-Type Thermcouple Thermometer.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section four\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003cbr\u003e\u003ch3\u003eHanna Instruments-766TV1 Pipe clamp probe\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003eProbe for measuring the temperature of pipes and tubes.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/766tv1_diagram.jpg\"\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"section-image col-xs-12 col-sm-5 rem-p-r\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354393751703,"sku":"HI-766TV1","price":82.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-766tv1_k-type_thermocouple_pipe_clamp_probe_1m_cable_94ca104d-c269-46b9-96fa-b4ae657876fe.jpg?v=1624279346"},{"product_id":"hanna-instruments-7873-220-liquid-level-controller","title":"Hanna Instruments-7873\/220 Liquid Level Controller","description":"Hanna Instruments-7873 mini-level controller is ideal for liquid level control over distances of up to 100 meters (330 feet). It is highly compact and will fit in tight spaces.\u003cbr\u003e\u003cp\u003eThese easy-to-use controllers are ideal for nearly any liquid level application, such as industrial and municipal water treatment, nutrient tank control in farming, hydroponics, aquaculture applications and plating rinse baths.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-7873 includes an overflow alarm and can be connected to a 2-wire transmitter, which is ideal for level monitoring in remote applications.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA complete liquid level measuring system requires:\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eController (Hanna Instruments-7873)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003ebar holder with amplifier circuitry (Hanna Instruments-7874)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eMeasuring bars (Hanna Instruments-731324)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUndecal connector (Hanna Instruments-7164)\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-7873 requires four bars with the additional bar used for overflow measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information:\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-7873 is supplied with mounting brackets and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354393915543,"sku":"HI-7873\/220","price":163.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-7873220_liquid_level_controller.jpg?v=1624279354"},{"product_id":"hanna-instruments-935004p-t-type-thermocouple-thermometer-for-the-food-industry","title":"Hanna Instruments-935004P T-type Thermocouple Thermometer for the Food Industry","description":"\u003cp\u003eHanna Instruments-935004 is a thermometer that includes a T-type thermocouple stainless steel replaceable style penetration probe (FC767PW). This thermometer offers temperature measurement from -50 to 300°C.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eStandard features include waterproof casing and stainless steel penetration probe for measurements in semi-solid food, liquids or pastes. Hanna Instruments-935004 also includes features such as CAL check, low battery detection, auto-off capability, and long battery life.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eCAL Check™ Feature\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-935004 includes Hanna‘s exclusive CAL Check™ technology. CAL Check™ allows the user to check calibration status. If the meter is calibrated, the display will automatically show \"0.0°C\" during startup.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLow Battery Indicator\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe included AAA batteries provide 3500 hours of continuous use. When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eAutomatic Shut-off\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe auto-off feature can be set to shut the meter off at 8 or 60 minutes, or it can be disabled so that the meter continuously stays on. The auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354394046615,"sku":"HI-935004P","price":106.97,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/935004p_default_e3864514-2cce-488a-bf24-f5b3a443300f.jpg?v=1624279360"},{"product_id":"fc2423-foodcare-ph-and-temperature-electrode-for-cheese-1","title":"FC2423 Foodcare pH and temperature electrode for cheese","description":"The FC2423 used with the HI-98165 is designed specifically for measuring pH in cheese.\u003cbr\u003e\u003ch3\u003eFC2423 Foodcare pH and temperature electrode for cheese\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eCheese products can provide challenges for the person that needs to measure pH. Cheese products tend to be solid to semi-solids. Both types of samples will coat the sensitive glass membrane surface and\/or clog the reference junction.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFrom a conic tip shape in a durable 5 mm diameter stainless steel body for easy penetration into cheese without leaving a large hole to an open junction that resist clogging; the FC2423 is an ideal general-purpose pH electrode for cheese. The FC2423 connects to the HI-98165 with a quick-connect, waterproof DIN connector, allowing for a secure, non-threaded attachment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe robust stainless steel sheath paired with the conical sensing tip allows for penetration in cheese at various points throughout the production process. An integrated temperature sensor also ensures that all pH measurements are compensated for temperature without the need for a separate temperature probe.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eMore information\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eStainless steel body\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eConic Glass Tip\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-In Temperature Sensor\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLow temperature glass\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eFor use with the HI-98165 Foodcare meter\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354394996887,"sku":"FC2423","price":342.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/fc2423_foodcare_ph_and_temperature_electrode_for_cheese_35dfb324-a94d-4c99-b7e6-84b23761e561.jpg?v=1624279404"},{"product_id":"hanna-instruments-70632l-electrode-cleaning-and-disinfection-solution-for-blood-products","title":"Hanna Instruments-70632L Electrode Cleaning  and Disinfection Solution for Blood Products","description":"Here at HANNA, we recommend to always clean an electrode after every testing to eliminate impurities and residue. Regular cleansing and proper care ensures the electrode is correctly maintained for maximum performance to achieve accurate readings, faster response times, and repeatability.\u003cbr\u003e\u003ch3\u003eHanna Instruments-70632L Cleaning \u0026amp; Disinfection Solution for Blood Products (500 mL)\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-70632L is a highly-effective cleaning and disinfection solution specially formulated for use in applications where a pH electrode is in contact with blood products.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eElectrodes become dirty from use and will produce inaccurate results even if they read correctly in a pH buffer. HANNA’s cleaning solutions eliminate impurities and residues which are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAt HANNA, we suggest cleaning the bulb and junction of your electrode on a regular basis in our ready-to-use cleaning solutions to ensure that the probe is always clean and to prevent any clogging of the junction.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAll cleaning solutions are packaged in an air tight bottle with tamper-proof seal to ensure quality and freshness. All solutions show a batch number and expiry date.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAvailable in 500ml bottles. \u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eUseful tips:\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAfter cleaning, rinse the electrode in tap water and then place in a HANNA Storage Solution before calibrating or taking measurements.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlways follow up with a HANNA Buffer\/calibrating Solution for the best results.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eWhich cleaning solution to use . . .?\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eGeneral Cleaning\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eSoak in HANNA General Cleaning Solution (Hanna Instruments-7061) for between 30 minutes and 1-and-a-half hours to dissolve mineral deposits and other general coatings. (Non-aggressive formula).\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eProtein Coating\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eSoak in HANNA Protein Cleaning Solution (Hanna Instruments-7073) for 15 minutes to enzymatically dissolve deposits from protein sources.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eInorganic Soak\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eSoak in HANNA Inorganic Cleaning Solution (Hanna Instruments-7074) for 5 to 15 minutes. This cleaner is especially effective at removal of precipitates caused by possible reactions - Usually used in industrial applications.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eOil and Grease Rinse\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eOil and grease removal require the correct chemicals to dissolve the coating, but mild enough to leave the electrode unaffected. Use HANNA Hanna Instruments-7007 or Hanna Instruments-8077 Oil and Fat Cleaning Solution for effective cleaning after each measurement, followed by flushing with tap water.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eSpecialised Cleaning Solutions\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eWine deposits (Hanna Instruments-70635L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eWine stains (Hanna Instruments-70636L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSalt (Hanna Instruments-70670L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCheese (Hanna Instruments-70642L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eMilk (Hanna Instruments-70640L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDairy – Cleaning and Disinfection Solution (Hanna Instruments-70641)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSoil (Hanna Instruments-70663L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHumus (Hanna Instruments-70664L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAgricultural (Hanna Instruments-700661P)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eInk (Hanna Instruments-70681L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlgae, Fungi and Bacteria (Hanna Instruments-70671L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBlood – Cleaning and Disinfection Solution (Hanna Instruments-70632L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlkaline cleaning for meat grease and fats (Hanna Instruments-70631L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAcid cleaning solution for meat grease and fats (Hanna Instruments-700630P)\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eRemember:\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eCleaning is a fast and effective routine which should be performed on a regular basis as a preventative measure against using dirty equipment.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlways clean the junction and bulb of the electrode\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlways clean your meter, electrode or probe before calibration\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, modern pH meters assume that the electrode is clean and will give you a starting point accordingly. So, if you haven’t cleaned your meter, your readings will be inaccurate from the start.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eAll ready-to-use cleaning solutions are made with the highest quality of materials and chemicals complying with standards set by the National Institute of Standards and Technology (NIST), to ensure quality and accuracy. Also available in light blocking bottles to prevent against degradation by UV light compatible with FDA Standards (US Food and Drug Administration).\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354395095191,"sku":"HI-70632L","price":39.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-70632l_electrode_cleaning_and_disinfection_solution_for_blood_products_952e47bf-da82-4e51-ac06-3dad0e8fdb3c.jpg?v=1624279404"},{"product_id":"fc231d-intelligent-electrode-for-meat-products-1","title":"FC231D 'Intelligent Electrode' for Meat Products","description":"The Hanna FC231D is a specialised electrode designed for use in the food industry using one of the Hanna 'Intelligent Electrode' compatible meters. It is suitable for pH measurement of meat products and can be fitted with 2 different length knife blades.\u003cbr\u003e\u003ch3\u003eIntelligent pH Electrode for Meat Products\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe FC231D is a specialised electrode designed for use in the food industry. It is suitable for pH measurement of meat products and can be fitted with two different knife blades.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis electrode is supplied complete with a 1m white food cable and 7-pin DIN connector.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLow Temperature Glass Formulation\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe glass tip uses a special LT glass formulation with a lower resistance of approximately 50 megaohms compared to general purpose (GP) with a resistance of about 100 megaohms. This is beneficial since many food products are stored at low temperatures. As the temperature of the glass decreases in the sample, the resistance of the LT glass will increase approaching that of GP glass at ambient temperatures. If using GP glass, the resistance would increase above the optimum resistance for the high impedance input of a pH meter. The FC231D is suitable to use with samples that measure from 0 to 50°C.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003ePVDF Body\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003ePolyvinylidene fluoride (PVDF) is a food grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOpen Junction Reference\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eSuspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time, erratic readings, and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag\/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable readings.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eDIN Connector\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe FC231D Smart pH electrode has a DIN connector that can only be used with the HI-98140, HI-98150, HI-98230, and H-I98240 portable meters.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eBuilt-In Microchip\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe built-in microchip stores sensor type, serial number and calibration information including date, time, offset, slope, probe condition, and buffers used. This information is automatically retrieved by edge® once the electrode is plugged in. The ability to transfer information allows for hot swapping of probes without having to recalibrate. All pH measurements are performed within the electrode and transferred digitally to the meter. This overcomes any noise issues associated with the traditional high impedance analogue measuring system. Electrical noise can be generated from a built in temperature sensor and while working in a humid environment.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354395324567,"sku":"FC231D","price":304.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/fc231d_intelligent_electrode_for_meat_products_e064ab99-593d-4869-a6b3-131f2ee4a8c4.jpg?v=1624279418"},{"product_id":"hanna-instruments-4110-fluoride-combination-ise-electrode","title":"Hanna Instruments-4110 Fluoride Combination ISE Electrode","description":"\u003cp\u003eThe Hanna Instruments-4110 is a solid state, combination ion selective electrode (ISE) for the determination of fluoride (F-) in solution. The lanthanum fluoride crystal membrane produces a potential change due to the fluoride ion exchange between the membrane and the sample. The internal sensing elements are housed within a durable body, composed of a mixture of polyetherimide (PEI) and epoxy.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4110 is ideal for a variety of applications in drinking water treatment, environmental monitoring, and plating baths.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eSolid state sensor\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSkirted cone geometry\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDetection from 0.02 mg\/L to saturated F-\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4110 is a Fluoride combination ISE ideal for the detection of Free Fluoride in potable water, soft drinks, wine, plants, emulsified food products, plating and pickling acids.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4110 fluoride selective electrode is a complete potentiometric cell that contains a silver\/silver chloride (Ag\/AgCl) reference housed within a PEI\/epoxy body with a potassium nitrate\/potassium chloride electrolyte. The internal elements are isolated from the sample by a lanthanum fluoride crystal membrane.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna’s solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFor the Hanna Instruments-4110 to accurately measure total fluoride concentration, it is important that the pH and ionic strength of the standards and sample be adjusted to a constant value. The total ionic strength adjustment buffer (TISAB) ensures that the solution pH is between pH 5 and 8 and that the activity coefficient is constant. The TISAB solution also preferentially complexes with various metal ions, such as aluminium and iron, which tend to form complexes with fluoride ions. TISAB thus ensures that these metal ions do not interfere, permitting an accurate total fluoride measurement. Measuring all solutions with a constant pH and ionic strength reduces the margin of error between measurements. The Hanna Instruments-4110 fluoride solid state ion selective electrodes can measure from 1µM (0.02 mg\/L) to saturated F-.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eReplaceable Sensing Modules - Combination solid state ion selective electrodes are electrodes that detect free ions in a solution. The lanthanum fluoride crystal sensing membrane is replaceable and easy to attach to the sensor body.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDurable PEI Body - The probe body is composed of a mixture of polyetherimide (PEI) and epoxy.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBNC Connection - The Hanna Instruments-4110 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354396340375,"sku":"HI-4110","price":995.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-4110_fluoride_combination_ise_electrode_4bf12a2f-f651-47a3-938b-8ca7a9bf197e.jpg?v=1624279453"},{"product_id":"hanna-instruments-96832-refractometer-for-propylene-glycol","title":"Hanna Instruments-96832 Refractometer for Propylene Glycol","description":"\u003cform action=\"https:\/\/www.hannainstruments.co.uk\/checkout\/cart\/add\/uenc\/aHR0cHM6Ly93d3cuaGFubmFpbnN0cnVtZW50cy5jby51ay9wcm9weWxlbmUtZ2x5Y29sLXJlZnJhY3RvbWV0ZXItMC0xMDAuaHRtbA,,\/product\/1725\/form_key\/A5v7u5usUOjSHa38\/\" id=\"product_addtocart_form\" method=\"post\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__product-essential__product-shop col-sm-5 col-xs-12 rem-pad-mobile rem-p-r\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__product-essential__product-shop__short-description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"std\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-96832 Propylene Glycol Digital Refractometer is a rugged, portable, water resistant device that utilises the measurement of refractive index to determine the percentage volume and freezing point of propylene glycol based solutions.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/form\u003e\u003cbr\u003e\u003cdiv class=\"product-view__roundels col-xs-12 col-sm-5 rem-p-r\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/waterresistant_roundel_219.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eWater Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/battery_roundel_254.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eBattery powered – Allows use away from a power source. Batteries are included with all battery operated products.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cp\u003eThis digital refractometer eliminates the uncertainty associated with mechanical refractometers. Hanna Instruments-96832 samples are measured after a simple user calibration with distilled or deionised water.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eWithin seconds, the refractive index and temperature are measured and converted into one of two measurement units; % volume or freezing point.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis meter uses internationally recognised references for unit conversion and temperature compensation for glycol solutions.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eDual-level LCD displays measurement and temperature readings simultaneously\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAutomatic Temperature Compensation for accurate measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eEasy measurement; place a few drops of the sample in the well and press the READ key\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eMain benefits\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eQuick, accurate results, readings are displayed in approximately 1.5 seconds\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSingle point calibration with distilled or deionised water\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSmall sample size; can be as small as 2 metric drops\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eStainless steel sample well, easy to clean and corrosion resistant\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eSupplied with\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBattery\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eInstructions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354396602519,"sku":"HI-96832","price":323.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-96832_refractometer_for_propylene_glycol_ed892abb-8134-448d-a314-f2787e6e707a.jpg?v=1624279455"},{"product_id":"hanna-instruments-766z-7-k-type-thermocouple-wire-probe-for-ovens-7m-cable","title":"Hanna Instruments-766Z\/7 K-Type Thermocouple Wire Probe for Ovens, 7m cable","description":"\u003cform action=\"https:\/\/www.hannainstruments.co.uk\/checkout\/cart\/add\/uenc\/aHR0cHM6Ly93d3cuaGFubmFpbnN0cnVtZW50cy5jby51ay93aXJlLXRlbXBlcmF0dXJlLXByb2JlLWZvci1vdmVucy03LW0tY2FibGUuaHRtbA,,\/product\/1130\/form_key\/A5v7u5usUOjSHa38\/\" id=\"product_addtocart_form\" method=\"post\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__product-essential__product-shop col-sm-5 col-xs-12 rem-pad-mobile rem-p-r\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__product-essential__product-shop__short-description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"std\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-766PX series are K-type thermocouple temperature probes to be used with thermocouple thermometers – ideal for industrial situations where very high temperatures are expected. All probes in the Hanna Instruments-766 series are made from stainless steel for long life and easy cleaning. The series includes a wide range of probes for measurement of liquids, air, gas and penetration in semi-solids, as well as curved, planed or hard-to-reach surfaces. In addition, models are available with interchangeable or fixed handles for maximum versatility.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/form\u003e\u003cbr\u003e\u003cdiv class=\"product-view__roundels col-xs-12 col-sm-5 rem-p-r\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/ktype_roundel_39.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eK-type Connection – Industry standard K-type Thermocouple connector. Can be used with any HANNA K-type thermocouple thermometer.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-766Z\/7 is a K-Type Thermocouple wire probe specifically designed to measure temperatures inside ovens.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThis probe has a 7m cable.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section four\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003cbr\u003e\u003ch3\u003eHanna Instruments-766Z Wire Temperature Probe\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003eWire probe designed to measure temperature inside ovens.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cimg src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/766z_diagram_2.jpg\"\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354396831895,"sku":"HI-766Z\/7","price":287.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-766z7_k-type_thermocouple_wire_probe_for_ovens_7m_cable.jpg?v=1624279457"},{"product_id":"bl-983314-0-resistivity-mini-controller-1","title":"BL-983314-0 Resistivity Mini Controller","description":"The BL-983314 is a simple to operate resistivity controller designed for ultra pure water, reverse osmosis, and water conditioning applications. The BL-983314 resistivity controller is also ideal for continuous monitoring to process solutions. Setpoint and calibration are manually adjusted with a trimmer and the alarm relay allows for simple control.\u003cbr\u003e\u003ch3\u003eAbout the BL-983314 Resistivity Mini Controllers\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFire retardant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSelectable overdose protection system\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSplash-resistant cover\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eReadings are automatically temperature compensated with three different coefficients (β=2.4, 3.5 or 4.5 %\/°C). The alarm contact can be used for connection to an alarm, pump, solenoid or dosing system.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe relay contact is open when readings are higher than the setpoint, while for measurements lower than setpoint, the relay contact is closed. The hysteresis is typically 0.20 MΩ •cm from the setpoint.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMeasurements are displayed on the LCD and the multi-coloured LED continuously indicates if the controller is in measurement, dosing, or alarm mode. Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits operators to enable or disable the dosing relay according to need.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe overtime control system advises users when the relay is active for too long, helping to prevent over-dosage.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354397061271,"sku":"BL-983314-0","price":350.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983314-0_resistivity_mini_controller_1_6165b1eb-d17a-47d9-87e4-fb041ae86748.jpg?v=1624279469"},{"product_id":"hanna-instruments-96801-refractometer-for-general-purpose-sugars","title":"Hanna Instruments-96801 Refractometer for General Purpose Sugars","description":"\u003cform action=\"https:\/\/www.hannainstruments.co.uk\/checkout\/cart\/add\/uenc\/aHR0cHM6Ly93d3cuaGFubmFpbnN0cnVtZW50cy5jby51ay9yZWZyYWN0b21ldGVyLWdlbmVyYWwtcHVycG9zZS1zdWdhcnMuaHRtbA,,\/product\/1712\/form_key\/A5v7u5usUOjSHa38\/\" id=\"product_addtocart_form\" method=\"post\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__product-essential__product-shop col-sm-5 col-xs-12 rem-pad-mobile rem-p-r\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__product-essential__product-shop__short-description\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"std\"\u003e\n\u003cbr\u003e\n\u003cp\u003eThe Hanna Instruments-96801 measures the refractive index to determine the % Brix of sugar in aqueous solutions. The refractive index of the sample is converted to % Brix concentration units.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eHanna offers five sugar refractometers to meet the requirements of the food industry. The Hanna Instruments-96800 Refractive Index\/Brix, Hanna Instruments-96801 % Brix (sucrose), Hanna Instruments-96802 Fructose, Hi-96803 Glucose, and Hanna Instruments-96804 Invert Sugar digital refractometers are rugged, portable and water-resistant for measurements in the lab or field.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/form\u003e\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels col-xs-12 col-sm-5 rem-p-r\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/waterresistant_roundel_207.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eWater Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/battery_roundel_242.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eBattery powered – Allows use away from a power source. Batteries are included with all battery operated products.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\n\u003cp\u003eThe Hanna Instruments-98601 is used across the food industry for measuring the concentrations of general purpose sugars in foods.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eQuick and easy to use it is ideal for analysing the sugar content in a wide range of food products including fruit, energy drinks, puddings, tofu, jams, honey, soups and sauces.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003ePriced inexpensively does not mean a compromise on accuracy, the Hanna refractometer offers all the benefits of high precision digital technology at the same price as a mechanical model.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eThe Hanna Instruments-96801 measures the refractive index to determine the % Brix of sugar in aqueous solutions. The refractive index of the sample is then converted to % Brix concentration units.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eProduct uses\u003c\/h3\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eFruit growers and importers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eFruit juice \u0026amp; drink manufacturers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eProduction of jams, preserves \u0026amp; sauces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ch3\u003eOrder Information\u003c\/h3\u003e\n\u003cbr\u003e\n\u003cp\u003eThe following options are available below:\u003c\/p\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eHanna Instruments-96801 - Sucrose sugar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eHanna Instruments-96802 - Fructose sugar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eHanna Instruments-96803 - Glucose sugar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eHanna Instruments-96804 - Inverted sugar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"section-row section four\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003cbr\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eWhite, water resistant, casing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEasy clean sample well\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eZero using pure water\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBattery operated with auto shut-off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ch3\u003eMain benefits\u003c\/h3\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e1.5 second measurement time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eDirect readout in % Brix and °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eNo calibration solutions required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eLarge clear LCD display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354397520023,"sku":"HI-96801","price":355.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/image_13775_85edda50-ad6d-426b-83b6-03797b578e7d.jpg?v=1624279473"},{"product_id":"hanna-instruments-98501-checktemp®-digital-thermometer","title":"Hanna Instruments-98501 Checktemp® Digital Thermometer","description":"Checktemp is a great choice for easy operation with clear digits and better accuracy over a wide range without fear of breakage or condensation.\u003cbr\u003e\u003cdiv class=\"rangeOverview sub-range\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Checktemp delivers high accuracy temperature measurements over a wide range without concern for breakage or condensation.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThe Checktemp offers no breakage, no waste, and no difficulty in reading; the digital display prevents a parallax error (observing the wrong measurement due to the angle of view) and is optimised for a wide range of environmental temperatures.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eChecktemp is provided with Hanna’s unique CAL Check™ function for accurate measurements every time. The Checktemp® implements a CAL Check upon startup and reports the status as “0” or “err”.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThe sharp-tip probe of the Checktemp® easily penetrates semi-solid products making routine temperature checks simple and quick for both incoming and outgoing goods. Checktemp is the ideal instrument for measuring temperature according to HACCP requirements.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003ch3\u003e100% reassurance with Hanna Cal Check\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003eHanna's exclusive Cal Check, saves time and brings peace of mind to users in busy catering environments. In hot kitchens, fast production lines and hectic retail environments, few operators have the time to keep checking the accuracy of their meters.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eHanna Cal Check automatically verifies the thermometer circuit accuracy at 0.0°C every time it is switched on. During start up, the calibration of the thermometers circuit is checked and the result is briefly displayed on the thermometers display to show the operator the calibration result.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003ePlease note: \u003c\/strong\u003eThe Cal Check system can only check the electronic circuit calibration and does not check the sensor of the thermometer. For further peace of mind it is recommended to check the sensor by performing an ice test or comparative test against a reference thermometer.\u003c\/p\u003e\n\u003cbr\u003e\u003ch3\u003e\u003c\/h3\u003e\n\u003cbr\u003e\u003ch3\u003eCAL Check™\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003eAutomatically verifies calibration at startup and alerts the user of the calibration status.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003ch3\u003eSave battery life with auto-off feature\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003eWith the auto-off feature, select from 8 minutes, 60 minutes, or disable the feature.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003ch3\u003eEasy battery change\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003eEasily replace the battery with a twist-off cover.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003ch3\u003eProtective probe sleeve included\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003eProtects the probe when not in use.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354398044311,"sku":"HI-98501","price":56.43,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi98501_6ef05b40-04a6-4214-92ea-c082258862cd.jpg?v=1624279491"},{"product_id":"hanna-instruments-761-total-chlorine-ultra-low-range-handheld-colorimeter-checker®hc","title":"Hanna Instruments-761 Total Chlorine Ultra Low Range  Handheld Colorimeter, Checker HC","description":"\u003cdiv class=\"row\"\u003eThe Hanna Instruments-761 Checker is a simple, accurate, and cost effective way to measure ultra-low ranges of total chlorine.\u003cbr\u003e\n\u003cdiv id=\"description\" class=\"section-row section 1\"\u003e\n\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cp\u003eDesigned as a more accurate alternative to chemical test kits, this checker provides quick, accurate results in four easy steps\u003c\/p\u003e\nThe Hanna Instruments-761 uses an adaptation of the USEPA method 330.5. The reaction between the chlorine and DPD reagent causes a pink tint in the sample.\u003cbr\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\nSmall palm-sized design\u003c\/div\u003e\n\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cp\u003eAccurate from ±5ppb ± 5% of reading\u003c\/p\u003e\nDedicated to a single parameter\u003cbr\u003e\n\u003cp\u003eUses a single AAA battery\u003c\/p\u003e\nAuto Power Off after 10 minutes in inactivity\u003cbr\u003e\n\u003cp\u003eBuilt-in timer for timed reaction readings\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eIdeal for:\u003c\/h3\u003e\nWater Quality\u003cbr\u003e\n\u003cp\u003eEducation\u003c\/p\u003e\nWater Purification\u003cbr\u003e\n\u003cp\u003eEnvironmental\u003c\/p\u003e\n\u003cbr\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003eThe Hanna Instruments-761 Checker is supplied with 2 cuvettes and caps, reagent starter kit (6 packets for total chlorine ultra-low range - re-ordering information Hanna Instruments-761-25 x 25 tests), 1 x 1.5V AAA battery, and an instruction manual.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eAlso available: Calibration set Hanna Instruments-711-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFour steps. One click. Instant Readout\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"section-row section nine\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6 rem-pad-mobile rem-p-l\"\u003e\n\u003cdiv class=\"section-text col-xs-7 col-sm-9\"\u003e\n\u003cp\u003e1. ‘Zero’ the Checker®HC with your vial inside\u003c\/p\u003e\n\u003c\/div\u003e\n2. Place a 10ml water sample into the vial and add your reagent\u003c\/div\u003e\n\u003cbr\u003e3. Place your vial into your Checker®HC\u003cbr\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6 rem-pad-mobile rem-p-r\"\u003e\n\u003cdiv class=\"section-image col-xs-5 col-sm-3 circle-left\"\u003e\u003cbr\u003e\u003c\/div\u003e\n4. Press the button and read the results\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":54897205051765,"sku":"HI-761","price":71.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/total-chlorine-checker-ultra-low-range-0-to-500ppb.jpg?v=1733408724"},{"product_id":"bl-982411-1-orp-controller-range-0-to-1000-mv-1","title":"BL-982411-1 ORP Controller (Range 0 to 1000 mV)","description":"\u003cp\u003eBL 982411 is an ORP mini controller for panel mounting, specially designed for swimming pools and spas. Thanks to its compact size, BL 982411 can be installed in small spaces.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eBL 982411 is an ORP mini controller for panel mounting, specially designed for swimming pools and spas. Thanks to its compact size, BL 982411 can be installed in small spaces. BL 982411 is the ideal solution for those who have always checked ORP manually. Thanks to the automatic dosing, this mini controller will significantly reduce maintenance time.\u003c\/p\u003e\n\u003cp\u003eBL 982411 can be used with any ORP electrode with standard BNC connector. The instrument measures ORP in the 0 to 1000 mV range and shows the readings on the large display.\u003c\/p\u003e\n\u003cp\u003eThe status LED continuously indicates if the controller is in measurement, dosing or alarm mode.\u003c\/p\u003e\n\u003cp\u003eBL 982411 is also provided with a relay for selecting the dosing direction, oxidising or reducing.\u003c\/p\u003e\n\u003cp\u003eYou can also choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits you to enable or disable the dosing relay according to your need.\u003c\/p\u003e\n\u003cp\u003eThe overtime control system advises you when the relay is active for too long, helping to prevent over-dosage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL 982411 is supplied with mounting brackets, transparent cover, and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354400698519,"sku":"BL-982411-1","price":231.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-982411-1_orp_controller_range_0_to_1000_mv_3aa47787-c9aa-4d4c-8381-e228819fb2b0.jpg?v=1624279530"},{"product_id":"hanna-instruments-98713-iso-portable-turbidity-meter-with-fast-tracker-technology","title":"Hanna Instruments-98713 ISO Portable Turbidity meter with Fast Tracker Technology","description":"\u003cp\u003eThe Hanna Instruments-98713 meets and exceeds the requirements of the ISO 7027 for water quality. The instrument is specially designed for water quality measurements, providing a reliable and accurate reading on low turbidity values. Ratio method with 90° and 180° light detector for accurate measurements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-98713-02 meets and exceeds the requirements of the ISO 7027 for water quality and provides reliable and accurate readings on low turbidity values.\u003c\/p\u003e\n\u003cp\u003eAn effective algorithm calculates and converts the detectors output in FNU. Depending on the needed accuracy, normal, continuous, or signal averaging can be selected.\u003c\/p\u003e\n\u003cp\u003eThe optical system consists of an infrared LED and two detectors, that assures long term stability and minimises stray light and colour interferences.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-98713 also compensates for variations in intensity of the LED, minimising the need for frequent calibration.\u003c\/p\u003e\n\u003cp\u003eThis instrument incorporates complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points, time and date can be checked at the touch of a button.\u003c\/p\u003e\n\u003ch3\u003eKey features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo, three or four point calibration\u003c\/li\u003e\n\u003cli\u003eUSB and RS 232 PC connectivity\u003c\/li\u003e\n\u003cli\u003eLog up to 200 records\u003c\/li\u003e\n\u003cli\u003eGLP Features\u003c\/li\u003e\n\u003cli\u003eContinuous current time on display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eExclusive Fast Tracker™\u003c\/h3\u003e\n\u003cp\u003eFor advanced field applications, the Hanna Instruments-98713 is equipped with Fast Tracker™-Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.\u003c\/p\u003e\n\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSample cuvettes and caps\u003c\/li\u003e\n\u003cli\u003eHanna Instruments-98713-11 calibration cuvettes\u003c\/li\u003e\n\u003cli\u003eCuvette cleaning cloth\u003c\/li\u003e\n\u003cli\u003eBatteries and AC adapter\u003c\/li\u003e\n\u003cli\u003eInstructions and rugged carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv id=\"product_tabs\" class=\"product__tabs\"\u003e\n\u003cdiv class=\"headings\"\u003e\u003cstrong\u003e\u003cspan id=\"product_specification_heading\" class=\"cta_specification active\"\u003eSpecification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"tabs\"\u003e\n\u003cdiv class=\"tab specification active\"\u003e\n\u003cdiv class=\"tab__content\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 9.99 FTU\u003cbr\u003e10.0 to 99.9 FTU\u003cbr\u003e100 to 1000 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Selection\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatically\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 FTU from 0.00 to 9.99 FTU\u003cbr\u003e0.1 FTU from 10.0 to 99.9 FTU\u003cbr\u003e1 FTU from 100 to 1000 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% of reading plus 0.1 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatibility\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or 0.01 FTU, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical EMC Deviation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.05 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e860 nm infrared LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of ISO 7027, ratio method with 90° and 180° detector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e60 x 90 mm LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1, 15, 100 and 750 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo, three or four point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e200 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 and USB 1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x 1.5V AA alkaline batteries or AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Shut-off\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 15 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e224 x 87 x 77 mm (8.8 x 3.4 x 3.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e512 g (18 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354406039703,"sku":"HI-98713-02","price":1382.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-98713_iso_portable_turbidity_meter_with_fast_tracker_technology_17a146e8-1a04-44aa-a69e-bcd7517017ac.jpg?v=1624279568"},{"product_id":"fc200s-foodcare-kynar-body-ph-electrode-1","title":"FC200S Foodcare Kynar Body pH Electrode","description":"This design is ideal for pH measurements in the food industry including dairy, dough, ground meats, and other semi-solid food samples. The recommended operating temperature range is from 0 to 50°C.\u003cbr\u003e\u003cp\u003eHanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe FC200S uses low temperature (LT) glass, conical bulb, food grade PVDF body, and open junction with viscolene gel electrolyte.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eConical Glass Tip\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe conical shaped tip design allows for penetration into solids, semi solids, and emulsions for the direct measurement of pH in food products including meat, cheese, yogurt, and milk.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOpen Junction Reference\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eSuspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time, erratic readings, and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag\/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable readings.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354406465687,"sku":"FC200S","price":236.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/fc200s_foodcare_kynar_body_ph_electrode_f97d0108-d8a5-4b7b-b673-069a0a4a568b.jpg?v=1624279592"},{"product_id":"hanna-instruments-96821-refractometer-for-food-industry-salt-measurements","title":"Hanna Instruments-96821 Refractometer for Food Industry Salt Measurements","description":"\u003cform action=\"https:\/\/www.hannainstruments.co.uk\/checkout\/cart\/add\/uenc\/aHR0cHM6Ly93d3cuaGFubmFpbnN0cnVtZW50cy5jby51ay9yZWZyYWN0b21ldGVyLWZvci1mb29kLWluZHVzdHJ5LXNhbHQtbWVhc3VyZW1lbnRzLmh0bWw,\/product\/1722\/form_key\/Ectq6sF2Y6PAxAOD\/\" id=\"product_addtocart_form\" method=\"post\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__product-essential__product-shop col-sm-5 col-xs-12 rem-pad-mobile rem-p-r\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__product-essential__product-shop__short-description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"std\"\u003e\n\u003cbr\u003e\u003cp\u003eHanna offers the Hanna Instruments-96821 digital Sodium Chloride refractometer to meet the requirements of the food industry. This optical instrument employs the measurement of the refractive index to determine sodium chloride concentration in aqueous solutions used in food preparation. It is not intended for seawater salinity measurements.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/form\u003e\u003cbr\u003e\u003cdiv class=\"product-view__roundels col-xs-12 col-sm-5 rem-p-r\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/battery_roundel_251.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eBattery powered – Allows use away from a power source. Batteries are included with all battery operated products.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/waterresistant_roundel_216.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eWater Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-96821 Salt Refractometer is portable, lightweight and easy to use as well as being precise and accurate. What's more it offers all the benefits of a digital meter at the cost of little more than a mechanical model.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eDesigned for use in the food industry, the Hanna Instruments-96821 is ideal for drop sampling and for testing the salt content of solutions used in food preparation.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eUsing the measurement of the refractive index to determine salt content, readings are quick and simple.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eSamples are measured after simple user calibration with distilled or deionised water. Within seconds the refractive index of the solution is measured with speed and precision.\u003c\/p\u003e\n\u003cbr\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eLarge dual level LCD displays measurement and temperature simultaneously\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSample well is designed for easy measurement - simply place a few drops of the sample in the well and press the READ key\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eWhite waterproof casing with stainless steel well is easy to keep clean\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLarge clear buttons make this meter easy to use in laboratory and test conditions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section four\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003cbr\u003e\u003ch3\u003eMain benefits\u003c\/h3\u003e\n\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003e1.5 second measurement time\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e0.1 resolution with 0.2% accuracy\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eZero using distilled or de-ionised water\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery operated with automatic shut-off after 3 minutes of non-use\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery error prevention system\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003e9v battery\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSimple operation: smart results\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eWhen the Salt Refractometer is turned on, the remaining battery life is first shown on the display followed by status for operation.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eTo select the unit of measurement required, simply press RANGE to key through the cycle of g\/100g; g\/100mL; Specific Gravity; Baumé.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eTo zero on start-up, use a pipette to cover the prism in the sample well with distilled or deionised water and press ZERO.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eTo take a measurement, use a plastic pipette to drip sample solution onto the prism surface until the well is full. Press READ to display results on the LCD in your selected units.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354408300695,"sku":"HI-96821","price":323.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-96821_refractometer_for_food_industry_salt_measurements_917dda56-644b-41e2-9673-7b01b57c450f.jpg?v=1624279619"},{"product_id":"hanna-instruments-99161-handheld-food-and-dairy-ph-meter","title":"Hanna Instruments-99161 Handheld Food and Dairy pH Meter","description":"\u003cp\u003eDedicated pH meter for food. Supplied complete with specialised food pH electrode for longer life and greater accuracy. Use with all types of foods including:\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eSoft Cheeses, Sushi Rice, Milk, Ready Meals\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eMayonnaise, Ketchup, Food Sauces, Jams, Chutneys\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAll types of semi-solid foods\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eMeasuring the pH of food requires a specialised pH electrode. Conventional pH electrodes will work but they will have a much shorter life when used to measure food products because the reference junction becomes clogged with food particles. The response time will also be slower and results can become inaccurate. Conventional electrodes are also more difficult to keep clean as food products are often sticky or difficult to remove when dry.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Hanna Instruments-99161 food pH meter is supplied complete with a specialised food pH electrode designed to overcome these problems.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354412724375,"sku":"HI-99161N","price":605.21,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-99161_handheld_food_and_dairy_ph_meter_2969c921-9394-4686-9d5a-5b8cda5bd905.jpg?v=1624279707"},{"product_id":"hanna-instruments-93531n-waterproof-k-type-thermocouple-thermometer","title":"Hanna Instruments-93531N Waterproof K-Type Thermocouple Thermometer","description":"When it's necessary to know the highest and lowest temperatures measured during a certain process, Hanna has incorporated a dual-level LCD into this portable range.\u003cbr\u003eAlong with the current reading, the highest and lowest temperature in the series can be assessed at a glance.\u003cbr\u003e\u003cp\u003eHanna has incorporated a dual-level LCD into this portable instrument. Along with the current reading, the highest and lowest temperature in the series can be assessed at a glance.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThese thermometers can read with a resolution of 0.1 in the range of -149.9 to 999.9°C or -24.9 to 999.9°F. The meters are equipped with a HOLD function that freezes the current reading on the display. A °C\/°F button will change between Celsius and Fahrenheit modes. Battery level is shown at startup and low battery warning with Battery Error Prevention System (BEPS) assure long periods of trouble-free use between battery changes.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-93531N also features a backlit LCD and can be calibrated at one point with a simple ice bath by pressing the CAL button.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHI 93531R is the top of the range model, featuring RS232 output for transferring measurements (once every second) to devices provided with RS232 input (PC or printer).\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna manufactures several thermocouple probes for different applications (HI 766 series).\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-93531N is supplied with batteries, protective case and instructions.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354415214743,"sku":"HI-93531N","price":294.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-93531n_waterproof_k-type_thermocouple_thermometer_4e5ed88a-c270-418f-9ced-1a4a4c5646b4.jpg?v=1624279744"},{"product_id":"hanna-instruments-76320-karl-fischer-dual-platinum-pin-electrode-for-hanna-instruments-903","title":"Hanna Instruments-76320 Karl Fischer Dual Platinum Pin electrode for Hanna Instruments-903","description":"For use with the Karl Fischer Hanna Instruments-903 Titrator.\u003cbr\u003e\u003ch3\u003eKarl Fischer Dual Platinum Pin electrode for Hanna Instruments-903\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-76320 is a glass bodied, dual platinum pin electrode for use with the Hanna Instruments-903 Karl Fischer titration system. Each sensor is designed for sensitive, precise, and accurate readings.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMore features:\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eGlass Body\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDual Platinum Pin\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBNC Connection\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354417508503,"sku":"HI-76320","price":534.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-76320_karl_fischer_dual_platinum_pin_electrode_for_hi-903_327bf69a-4202-4d85-8ebe-a0fbd5947e4c.jpg?v=1624279798"},{"product_id":"bl-983314-1-panel-mounted-resistivity-controller-115-230v-1","title":"BL-983314-1 Panel mounted resistivity controller 115\/230V","description":"\u003cp\u003eThe BL-983314 is a simple to operate resistivity controller designed for ultra pure water, reverse osmosis, and water conditioning applications. The BL-983314 resistivity controller is also ideal for continuous monitoring of process solutions. Setpoint and calibration are manually adjusted with a trimmer and the alarm relay allows for simple control.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFire-retardant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSelectable overdose protection system\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSplash-resistant cover\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eReadings are automatically temperature compensated, with three different coefficients (β=2.4, 3.5 or 4.5 %\/°C). The alarm contact can be used for connection to an alarm, pump, solenoid or dosing system.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe relay contact is open when readings are higher than the setpoint, while for measurements lower than setpoint, the relay contact is closed. The hysteresis is typically 0.20 MΩ•cm from the setpoint.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMeasurements are displayed on the LCD and the multi-coloured LED continuously indicates if the controller is in measurement, dosing, or alarm mode. Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits operators to enable or disable the dosing relay according to need.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe overtime control system advises users when the relay is active for too long, helping to prevent over-dosage.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354418950295,"sku":"BL-983314-1","price":350.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/bl-983314-1_panel_mounted_resistivity_controller_115230v_6509caee-4df1-408c-a645-a22340c09ff8.jpg?v=1624279827"}],"url":"https:\/\/testallwater.co.uk\/collections\/manufacturing-and-processing.oembed?page=2","provider":"Test All Water","version":"1.0","type":"link"}