{"title":"Controllers \u0026 Monitors","description":null,"products":[{"product_id":"milwaukee-mc122-pro-ph-controller","title":"Milwaukee MC122 PRO pH Controller","description":"\u003cp class=\"MsoNormal\"\u003eTake the guesswork out of pH regulation with the \u003cb\u003eMilwaukee MC122 pH Controller\u003c\/b\u003e – a trusted tool designed for precision, automation, and peace of mind. Whether you're growing plants hydroponically, maintaining a healthy aquarium, or fine-tuning a water treatment system, the MC122 offers \u003cb\u003econtinuous pH monitoring and on\/off control\u003c\/b\u003e, so you can set it and forget it.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eEquipped with a high-accuracy pH electrode, adjustable setpoint, and LED alarm system, the MC122 gives you full command over your pH environment. Once connected to a dosing pump or CO₂ system (not included), it becomes an automated solution that helps maintain your ideal pH range – \u003cb\u003e24\/7\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFrom hydroponic growers to aquarists, lab technicians to industrial operators, the MC122 delivers reliable control in a compact, easy-to-use unit trusted worldwide.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eWhy Choose the Milwaukee MC122?\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l17 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eContinuous Monitoring\u003c\/b\u003e – Real-time pH readings with automatic regulation.\u003c\/li\u003e\n\u003cli style=\"mso-list: l17 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003ePrecision Control\u003c\/b\u003e – Set your ideal pH range (setpoint adjustable from 5.5 to 9.5 pH).\u003c\/li\u003e\n\u003cli style=\"mso-list: l17 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eBuilt-In Alarm LED\u003c\/b\u003e – Visual alerts when pH is out of range.\u003c\/li\u003e\n\u003cli style=\"mso-list: l17 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCompact \u0026amp; Easy to Install\u003c\/b\u003e – Wall-mountable, durable housing.\u003c\/li\u003e\n\u003cli style=\"mso-list: l17 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eIncludes Quality pH Electrode\u003c\/b\u003e – Ready to go right out of the box.\u003c\/li\u003e\n\u003cli style=\"mso-list: l17 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eBNC Connection\u003c\/b\u003e – Compatible with a wide range of pH probes.\u003c\/li\u003e\n\u003cli style=\"mso-list: l17 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eIdeal for Automation\u003c\/b\u003e – Control acid\/base dosing or CO₂ injection with ease.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eProper Care \u0026amp; Maintenance\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eTo keep your MC122 performing at its best:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l4 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAlways store the pH electrode in storage solution (not water).\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eClean the electrode regularly using a cleaning solution (like MA9016).\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCalibrate often using pH buffer solutions (like MA9004 and MA9007).\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eReplace the electrode as needed to maintain accurate readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWe recommend adding the \u003cb\u003eMilwaukee pH Maintenance Kit (PH-Main)\u003c\/b\u003e to your order to support cleaning, calibration, and storage from day one.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eAutomate with Confidence. Trust Milwaukee.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're growing, brewing, farming, or treating water – \u003cb\u003ethe Milwaukee MC122 is your reliable partner for pH control\u003c\/b\u003e. Designed to simplify your workflow and protect your results, it's the perfect balance of performance and peace of mind.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"specification-tab-pane\" role=\"tabpanel\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eRange: 0.0 - 14.0 pH\u003c\/div\u003e\n\u003cdiv\u003eResolution: 0.1 pH\u003c\/div\u003e\n\u003cdiv\u003eAccuracy: ±0.2 pH\u003c\/div\u003e\n\u003cdiv\u003eSet point: 5.5 to 9.5 pH\u003c\/div\u003e\n\u003cdiv\u003eCalibration: Manual 2 points\u003c\/div\u003e\n\u003cdiv\u003eAlarm Active when reading is higher or lower than set point\u003c\/div\u003e\n\u003cdiv\u003eDosing Contact: 1 power plug for CO2 dosing\u003c\/div\u003e\n\u003cdiv\u003epH electrode: MA911B\/2 (included)\u003c\/div\u003e\n\u003cdiv\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/div\u003e\n\u003cdiv\u003ePower Supply: 12 VDC adapter (included)\u003c\/div\u003e\n\u003cdiv\u003ePower Drivers: 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz\u003c\/div\u003e\n\u003cdiv\u003eMounting kit (Included)\u003c\/div\u003e\n\u003cdiv\u003eDimensions: 5.9 x 3.2 x 1.35 inches\u003c\/div\u003e\n\u003cdiv\u003eWeight: 6.3 ounces (meter only)\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003epH Controller for Hydroponics \u0026amp; Horticulture\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eMaintaining the right pH in your nutrient solution is critical to maximizing plant health, nutrient absorption, and overall yield. Even small shifts in pH can lock out key nutrients, leading to deficiencies and stunted growth. That’s where the Milwaukee MC122 pH Controller steps in.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDesigned specifically for growers, the MC122 continuously monitors the pH level of your nutrient reservoir and automatically activates a connected dosing pump (not included) when the pH drifts out of your desired range. This means it can add pH-lowering (or raising) solution as needed – without any manual testing or adjustment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're growing leafy greens, tomatoes, or herbs, the MC122 helps you maintain a stable root-zone environment. By keeping your pH level consistently within the optimal range, it eliminates one of the most common causes of plant stress in hydroponic systems. That means healthier plants, faster growth, and bigger yields – with less daily effort.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use in Hydroponics:\u003c\/b\u003e\u003c\/p\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l3 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCalibrate the controller with standard buffer solutions.\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePlace the electrode in your nutrient reservoir.\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eConnect a dosing pump or CO₂ system to the controller’s power outlet.\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSet your desired pH setpoint.\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eThe controller will switch the dosing system on\/off to maintain pH stability.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003epH Controller for Aquariums \u0026amp; Aquaculture\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eStable pH levels are essential for the health and wellbeing of fish, aquatic plants, and corals. Even minor fluctuations can cause stress, disrupt biological balance, and make aquatic life more susceptible to disease. The Milwaukee MC122 pH Controller takes the guesswork out of maintaining ideal pH by providing continuous monitoring and automated control.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIdeal for both freshwater and marine aquariums, as well as larger aquaculture setups, the MC122 can be connected to a CO₂ regulator or pH dosing system (not included) to maintain precise pH levels 24\/7. When the pH drifts outside your set range, the controller automatically turns the connected device on or off to bring the water chemistry back in line – no constant manual testing or adjustment needed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis is especially valuable in planted aquariums where CO₂ injection is used to boost plant growth, or in reef tanks where corals require a narrow pH range to thrive. In breeding tanks or fish farms, the MC122 helps prevent dangerous pH swings that could otherwise impact reproduction or growth rates.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBy automating pH stability, the MC122 creates a safer, more predictable environment for aquatic life – making it easier to build and maintain a balanced ecosystem.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use in Aquariums:\u003c\/b\u003e\u003c\/p\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l7 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCalibrate the pH electrode.\u003c\/li\u003e\n\u003cli style=\"mso-list: l7 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePlace the electrode in your aquarium or sump.\u003c\/li\u003e\n\u003cli style=\"mso-list: l7 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePlug your CO₂ solenoid valve or dosing system into the controller.\u003c\/li\u003e\n\u003cli style=\"mso-list: l7 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSet the target pH range.\u003c\/li\u003e\n\u003cli style=\"mso-list: l7 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eLet the MC122 maintain balance automatically.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e  \u003cbr\u003e\u003c\/p\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003epH Controller for Water Treatment \u0026amp; Purification\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eIn water treatment and purification processes, maintaining precise pH levels is critical for both safety and performance. pH affects how well chemical reactions occur – such as neutralization, coagulation, precipitation of metals, disinfection with chlorine, and removal of contaminants. Deviations from the ideal pH range can compromise efficiency, increase chemical usage, and result in non-compliance with environmental regulations.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Milwaukee MC122 pH Controller offers a straightforward and reliable solution for managing pH in smaller-scale treatment systems or laboratory setups. It continuously monitors the pH level of your water and automatically controls dosing by switching an acid or base delivery system (dosing pump not included) on or off depending on your pre-set pH threshold.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIts compact footprint, dependable performance, and user-friendly design make it a practical tool for ensuring optimal water quality and regulatory compliance – without requiring constant manual oversight.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC122 in Water Treatment \u0026amp; Purification:\u003c\/b\u003e\u003c\/p\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l9 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eInstall the Controller – \u003c\/b\u003eMount the MC122 near your water tank or treatment system. Make sure it's protected from splashes and has access to a power outlet.\u003c\/li\u003e\n\u003cli style=\"mso-list: l9 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eConnect a Dosing Pump or System – \u003c\/b\u003eConnect a compatible dosing pump (sold separately) that delivers either acid (to lower pH) or base (to raise pH), depending on your system’s needs.\u003c\/li\u003e\n\u003cli style=\"mso-list: l9 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eInsert the Electrode – \u003c\/b\u003eSubmerge the included pH electrode into your water system, ideally in a spot with consistent flow for accurate readings.\u003c\/li\u003e\n\u003cli style=\"mso-list: l9 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSet Your Desired pH Range – \u003c\/b\u003eUse the dial on the front panel to set the pH level you want to maintain. The controller will turn the dosing system on or off automatically when readings fall outside this threshold.\u003c\/li\u003e\n\u003cli style=\"mso-list: l9 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate the Electrode – \u003c\/b\u003eBefore use, calibrate the probe using pH 7.01 and pH 4.01 buffer solutions to ensure accurate readings.\u003c\/li\u003e\n\u003cli style=\"mso-list: l9 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMonitor and Maintain – \u003c\/b\u003eRegularly check the probe for buildup and clean as needed. Replace the electrode periodically to maintain optimal accuracy.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003eBy automating pH control, the MC122 not only improves treatment results but also reduces the time, effort, and potential for error that comes with manual testing and dosing.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003epH Controller for Laboratories \u0026amp; Educational Use\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eMaintaining a stable pH is often crucial in laboratory and educational settings – whether you're running a chemical experiment, studying biological processes, or demonstrating pH-dependent reactions in a classroom. The Milwaukee MC122 pH Controller is a smart, affordable solution that brings automation and continuous monitoring into the lab.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDesigned for real-time observation and consistent pH regulation, the MC122 fits seamlessly into experimental setups where precise control over solution pH is required. It allows instructors and researchers to focus on the science, rather than worrying about manual adjustments or fluctuations that could compromise data or outcomes.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIn educational environments\u003c\/b\u003e, the MC122 is an excellent tool for demonstrating:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAcid-base titrations and buffering capacity\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eThe impact of pH on enzyme activity or microbial growth\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCO₂ control in aquatic environments for biology and ecology studies\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eWater chemistry and environmental science applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIn laboratories\u003c\/b\u003e, the controller supports:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePilot experiments involving automated dosing\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eConsistent pH in fermentation, chemical synthesis, or electrochemical studies\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eLong-term monitoring and reaction stability in controlled systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe unit’s clear digital readout, adjustable pH set point, and plug-and-play compatibility with standard dosing pumps (not included) make it ideal for both students and researchers. Compact and reliable, the MC122 brings professional-grade control into an accessible and user-friendly format.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC122 in Laboratory \u0026amp; Educational Settings:\u003c\/b\u003e\u003c\/p\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l16 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMount the Controller – \u003c\/b\u003ePlace the MC122 in a secure location close to your experiment or demonstration area. Ensure it’s visible for observation but away from splashes.\u003c\/li\u003e\n\u003cli style=\"mso-list: l16 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eConnect the Electrode – \u003c\/b\u003eSubmerge the pH electrode into your beaker, flask, or reaction vessel. For best results, use it in well-mixed solutions to avoid localized readings.\u003c\/li\u003e\n\u003cli style=\"mso-list: l16 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eAttach a Dosing System (if applicable) – \u003c\/b\u003eIf your experiment requires automated pH control, connect a dosing pump filled with acid or base. For demonstrations, manual dosing can be triggered when the controller alerts you to a pH shift.\u003c\/li\u003e\n\u003cli style=\"mso-list: l16 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSet the Desired pH Value – \u003c\/b\u003eUse the adjustable set point dial to define your target pH. The controller will automatically activate the dosing system when the pH drifts outside the set range.\u003c\/li\u003e\n\u003cli style=\"mso-list: l16 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate the Electrode – \u003c\/b\u003eUse standard pH buffer solutions (typically 7.01 and 4.01 or 10.01) to calibrate the probe before use, ensuring accurate and reliable data.\u003c\/li\u003e\n\u003cli style=\"mso-list: l16 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eObserve \u0026amp; Record – \u003c\/b\u003eThe real-time digital display shows current pH values, making it ideal for visual learning or detailed data logging during experiments.\u003c\/li\u003e\n\u003cli style=\"mso-list: l16 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eClean \u0026amp; Store Properly – \u003c\/b\u003eAfter each use, rinse the electrode and store it in proper storage solution to extend its life and maintain performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003epH Controller for Homebrewing \u0026amp; Fermentation\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eFermentation isn’t just an art – it’s a science. pH plays a central role in shaping the flavor, safety, and overall success of your brew or ferment. The Milwaukee MC122 pH Controller brings precision and peace of mind to your process, allowing you to monitor and regulate pH levels with confidence.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're crafting \u003cb\u003ebeer, wine, kombucha, kefir\u003c\/b\u003e, or \u003cb\u003efermented vegetables\u003c\/b\u003e, maintaining a stable pH throughout the process helps control microbial activity, enhances flavor development, and extends shelf life. The MC122 is your silent assistant – automating pH control so you can focus on the craft, not just the numbers.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis compact, user-friendly unit continuously tracks the pH of your fermentation solution and activates a connected dosing pump (acid or alkaline, not included) whenever pH veers outside your set range. It’s ideal for brewers looking to:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l14 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eFine-tune mash pH for optimal enzymatic activity\u003c\/li\u003e\n\u003cli style=\"mso-list: l14 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eControl lactic acid development in sour beers or kombucha\u003c\/li\u003e\n\u003cli style=\"mso-list: l14 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePrevent spoilage in wild ferments\u003c\/li\u003e\n\u003cli style=\"mso-list: l14 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eEnsure safe acidity levels in vegetable and fruit fermentations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're a passionate hobbyist or a small-batch producer, the MC122 helps you achieve \u003cb\u003erepeatable, reliable fermentation results\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003cb\u003eHow to Use the MC122 for Fermentation \u0026amp; Brewing:\u003c\/b\u003e\u003c\/p\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMount the Controller Securely – \u003c\/b\u003eSet up the MC122 in your brewing or fermentation space, ideally close to your fermenter, carboy, or mash tun.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eInsert the pH Electrode – \u003c\/b\u003eSubmerge the pH electrode in your mash, wort, or fermentation brine. Stir gently to get an even reading if the solution is not naturally agitated.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSet the Desired pH – \u003c\/b\u003eUse the adjustable set point dial to choose your ideal pH value.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eConnect a Dosing Pump (optional) – \u003c\/b\u003eIf you wish to automate corrections, connect a dosing pump filled with an appropriate acid (like phosphoric or citric acid) or base (like calcium carbonate or baking soda solution). When pH drifts, the MC122 triggers the pump to bring it back in range.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate the Electrode – \u003c\/b\u003eBefore each batch, calibrate the electrode using certified pH buffer solutions to ensure accuracy.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eMonitor During Key Stages\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l18 level1 lfo15;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eBrewing: Track pH during mashing, boiling, and post-boil cooling\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l18 level1 lfo15;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eFermenting: Watch for shifts during active fermentation and aging\u003c\/p\u003e\n\u003col type=\"1\" start=\"7\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eClean and Store Properly – \u003c\/b\u003eAfter use, rinse the electrode thoroughly and store it in the proper solution to maintain accuracy and extend its lifespan.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003epH Controller for Pools \u0026amp; Spas\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eBalanced pool water is essential – not only for \u003cb\u003eswimmer comfort\u003c\/b\u003e but also for \u003cb\u003eequipment longevity\u003c\/b\u003e, \u003cb\u003echemical efficiency\u003c\/b\u003e, and \u003cb\u003eoverall water safety\u003c\/b\u003e. The \u003cb\u003eMilwaukee MC122 pH Controller\u003c\/b\u003e takes the guesswork out of pH regulation by providing \u003cb\u003econtinuous monitoring and automatic control\u003c\/b\u003e, ensuring your water stays within the ideal range.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're managing a \u003cb\u003esmall hotel spa\u003c\/b\u003e, a \u003cb\u003ehome hot tub\u003c\/b\u003e, or a \u003cb\u003eprivate pool\u003c\/b\u003e, the MC122 helps maintain water quality without constant manual testing and dosing. By automating pH control, it prevents common issues like:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l12 level1 lfo11; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eEye and skin irritation caused by high or low pH\u003c\/li\u003e\n\u003cli style=\"mso-list: l12 level1 lfo11; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eScaling and corrosion in pipes, heaters, and filters\u003c\/li\u003e\n\u003cli style=\"mso-list: l12 level1 lfo11; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eInefficient chlorine performance when pH is off balance\u003c\/li\u003e\n\u003cli style=\"mso-list: l12 level1 lfo11; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCloudy water or unsanitary conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThis smart, compact controller can be connected to an acid dosing pump (not included) to automatically correct pH when it drifts outside your setpoint. It's an ideal solution for \u003cb\u003eowners who want precision without the hassle\u003c\/b\u003e, especially in pools that are used frequently or exposed to variable conditions (like rain, sun, or heavy swimmer load).\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC122 for Pools \u0026amp; Spas:\u003c\/b\u003e\u003c\/p\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l13 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eInstall the Controller Safely – \u003c\/b\u003eMount the MC122 near your pool’s pump\/filter system or spa control station, in a dry, shaded area that’s easy to access.\u003c\/li\u003e\n\u003cli style=\"mso-list: l13 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSubmerge the pH Electrode – \u003c\/b\u003ePlace the included pH probe in a continuously circulating part of the system – like near the return jet or inside the filtration loop – ensuring it stays wet and clean.\u003c\/li\u003e\n\u003cli style=\"mso-list: l13 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSet Your Ideal pH Range – \u003c\/b\u003eUse the controller dial to set the desired pH level. For most pools and spas, the target range is:\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l6 level1 lfo14;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePools: \u003cb\u003e7.2 to 7.6\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l6 level1 lfo14;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eHot tubs\/spas: \u003cb\u003e7.2 to 7.8\u003c\/b\u003e\u003c\/p\u003e\n\u003col type=\"1\" start=\"4\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l13 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eConnect to a Dosing Pump – \u003c\/b\u003elink the controller to a dosing pump filled with an appropriate \u003cb\u003eacid solution\u003c\/b\u003e (commonly muriatic acid or sodium bisulfate). When the water’s pH exceeds your set limit, the controller activates the pump to restore balance.\u003c\/li\u003e\n\u003cli style=\"mso-list: l13 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate Regularly – \u003c\/b\u003eCalibrate the probe using pH 7.01 and 4.01 buffer solutions to maintain measurement accuracy, especially during seasonal changes.\u003c\/li\u003e\n\u003cli style=\"mso-list: l13 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMonitor System Alerts – \u003c\/b\u003eThe LED indicator and relay output provide instant status updates, making it easy to know when adjustments are being made.\u003c\/li\u003e\n\u003cli style=\"mso-list: l13 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eMaintenance Tips\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l15 level1 lfo13;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRinse the pH probe regularly and store it in proper solution when not in use\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l15 level1 lfo13;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eInspect pump tubing and acid containers to prevent leaks or blockages\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l15 level1 lfo13;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eReview readings weekly to ensure everything is running smoothly\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eResult:\u003c\/b\u003e A consistently balanced pool or spa that feels better, looks clearer, and stays healthier—with less effort on your part.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003epH Controller for Industrial Processes\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eIn industrial settings, \u003cb\u003eprecise pH control\u003c\/b\u003e is often \u003cb\u003enon-negotiable\u003c\/b\u003e – impacting everything from \u003cb\u003eproduct consistency\u003c\/b\u003e and \u003cb\u003eoperational safety\u003c\/b\u003e to \u003cb\u003eenvironmental compliance\u003c\/b\u003e and \u003cb\u003eregulatory approval\u003c\/b\u003e. Whether it's \u003cb\u003eelectroplating\u003c\/b\u003e, \u003cb\u003echemical manufacturing\u003c\/b\u003e, \u003cb\u003ewastewater discharge\u003c\/b\u003e, or \u003cb\u003ecooling tower treatment\u003c\/b\u003e, the \u003cb\u003eMilwaukee MC122 pH Controller\u003c\/b\u003e offers a \u003cb\u003ecost-effective, compact, and reliable\u003c\/b\u003e solution for maintaining control over your process.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDesigned for \u003cb\u003econtinuous monitoring\u003c\/b\u003e and \u003cb\u003eautomated dosing control\u003c\/b\u003e, the MC122 ensures your pH stays within a defined setpoint – helping avoid:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l5 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eProduct defects caused by incorrect acidity\/alkalinity\u003c\/li\u003e\n\u003cli style=\"mso-list: l5 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eEquipment wear or corrosion from aggressive chemical conditions\u003c\/li\u003e\n\u003cli style=\"mso-list: l5 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eFines or shutdowns due to non-compliance with wastewater regulations\u003c\/li\u003e\n\u003cli style=\"mso-list: l5 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eProcess variability or batch inconsistency in sensitive production systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe MC122 is a trusted tool for \u003cb\u003esmall to mid-scale applications\u003c\/b\u003e and \u003cb\u003epilot plants\u003c\/b\u003e where a simple and effective pH automation system is needed – without the complexity or cost of industrial-grade PLCs or SCADA systems.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIdeal for:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l8 level1 lfo18; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eElectroplating and metal finishing\u003c\/li\u003e\n\u003cli style=\"mso-list: l8 level1 lfo18; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eChemical dosing and neutralization systems\u003c\/li\u003e\n\u003cli style=\"mso-list: l8 level1 lfo18; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eIndustrial cooling and boiler water treatment\u003c\/li\u003e\n\u003cli style=\"mso-list: l8 level1 lfo18; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eResearch and development pilot plants\u003c\/li\u003e\n\u003cli style=\"mso-list: l8 level1 lfo18; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eFood and beverage production lines\u003c\/li\u003e\n\u003cli style=\"mso-list: l8 level1 lfo18; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eTextile dyeing and finishing\u003c\/li\u003e\n\u003cli style=\"mso-list: l8 level1 lfo18; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePulp and paper mills\u003c\/li\u003e\n\u003cli style=\"mso-list: l8 level1 lfo18; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAgricultural water systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the MC122, industries gain a \u003cb\u003esimple, accurate, and durable pH controller\u003c\/b\u003e that takes the stress out of critical pH regulation – freeing up personnel and ensuring your process remains stable and compliant.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC122 for Industrial Processes:\u003c\/b\u003e\u003c\/p\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l11 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMount the Controller in a Safe Location – \u003c\/b\u003eInstall the unit in a protected environment near your process tanks, dosing system, or control panel. The compact design makes it easy to integrate into existing setups.\u003c\/li\u003e\n\u003cli style=\"mso-list: l11 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003ePosition the pH Probe in the Process Line or Tank – \u003c\/b\u003eSubmerge the pH electrode in an area with active flow or mixing to ensure accurate readings. For aggressive media, consider using a probe holder or protective sleeve.\u003c\/li\u003e\n\u003cli style=\"mso-list: l11 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSet Your Desired pH Setpoint – \u003c\/b\u003eUse the simple dial control to define the pH level you want to maintain (e.g., 4.5 for plating baths, 7.0 for neutralization, etc.).\u003c\/li\u003e\n\u003cli style=\"mso-list: l11 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eConnect to a Dosing Pump or Solenoid Valve – \u003c\/b\u003ePlug the MC122 into a dosing pump that adds either acid or base, depending on your process. The relay is triggered when the pH deviates from your setpoint, automating corrections.\u003c\/li\u003e\n\u003cli style=\"mso-list: l11 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate the System – \u003c\/b\u003eCalibrate the probe regularly using standard pH 7.01 and 4.01 buffer solutions. Frequent calibration ensures measurement accuracy in demanding environments.\u003c\/li\u003e\n\u003cli style=\"mso-list: l11 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003ePerform Routine Maintenance\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l10 level1 lfo19;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRinse and inspect the probe weekly\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l10 level1 lfo19;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eReplace the probe as needed, especially if exposed to harsh chemicals or particulates\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l10 level1 lfo19;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCheck pump flow rates and refill chemical reservoirs regularly\u003c\/p\u003e\n\u003col type=\"1\" start=\"7\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l11 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMonitor Operation – \u003c\/b\u003eVisual indicators on the unit make it easy to verify if the pH is within range or if the dosing system is actively engaged. For more advanced setups, the MC122 can be used in combination with data loggers or timers for additional control layers.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56101761745269,"sku":"MC122","price":206.44,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/MC122copy_1920x1920_5c6d4ea0-80e9-42ce-b48d-b20bab88cb8f.jpg?v=1760530039"},{"product_id":"milwaukee-mc310-pro-conductivity-ec-monitor","title":"Milwaukee MC310 PRO Conductivity (EC) Monitor","description":"\u003ch1\u003eACCURATE. SIMPLE. RELIABLE. 24\/7 CONDUCTIVITY (EC) MONITORING.\u003c\/h1\u003e\n\u003cdiv\u003eThe Milwaukee MC310 PRO Conductivity (EC) monitor lets you measure EC levels automatically and alerts with an alarm when out of the set point range.\u003c\/div\u003e\n\u003ch3\u003eSUMMARY\u003c\/h3\u003e\n\u003cdiv\u003eThe MC310 EC automatically monitors your EC levels. Just set your EC parameters and let the Milwaukee EC monitor do the rest.\u003c\/div\u003e\n\u003cdiv\u003eThe Milwaukee PRO EC monitor is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks, hydroponics, and horticulture.\u003c\/div\u003e\n\u003cdiv\u003eThe Milwaukee PRO EC monitor offers:\u003c\/div\u003e\n\u003ch4\u003eACCURACY\u003c\/h4\u003e\n\u003cdiv\u003eThe Milwaukee PRO EC monitor offers an accuracy to ±2% full scale.\u003c\/div\u003e\n\u003cdiv\u003eAUTOMATION\u003c\/div\u003e\n\u003cdiv\u003eThe monitor has a set-point range from 1.0 to 5.0 mS\/cm with alarms that activate when readings are higher or lower than set point.\u003c\/div\u003e\n\u003ch1 class=\"product-detail-name\" itemprop=\"name\"\u003e\u003cbr\u003e\u003c\/h1\u003e\n\u003ch2\u003eDESIGN FEATURES\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eFast easy to read current results with large digital LCD readout and visual LED alarm.\u003c\/li\u003e\n\u003cli\u003eAccurate to ±2% full scale (0.0 to 10.0 mS\/cm) with the user selectable high\/low set points.\u003c\/li\u003e\n\u003cli\u003eSimple one-point calibration for increased accuracy with manual trimmers for easy adjustment.\u003c\/li\u003e\n\u003cli\u003eMA812\/2 hardwired EC probe included.\u003c\/li\u003e\n\u003cli\u003e6.5 feet (2 meter) probe cables for extra flexibility when testing.\u003c\/li\u003e\n\u003cli\u003e12 VDC power supply.\u003c\/li\u003e\n\u003cli\u003eEasy to use, easy set up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"specification-tab-pane\" role=\"tabpanel\" aria-labelledby=\"specification-tab\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eRange: 0.0 - 10.0 mS\/cm\u003c\/div\u003e\n\u003cdiv\u003eResolution: 0.1 mS\/cm\u003c\/div\u003e\n\u003cdiv\u003eAccuracy: ±2% F.S.\u003c\/div\u003e\n\u003cdiv\u003eCalibration: Manual, 1-point\u003c\/div\u003e\n\u003cdiv\u003eSet point: 1.0 to 5.0 mS\/cm\u003c\/div\u003e\n\u003cdiv\u003eAlarm: Visual, active when reading is higher or lower than set point\u003c\/div\u003e\n\u003cdiv\u003eTemperature Compensation: Automatic, from 0 to 50°C | 32 to 122°F\u003c\/div\u003e\n\u003cdiv\u003eEC electrode: MA812\/2 (included)\u003c\/div\u003e\n\u003cdiv\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/div\u003e\n\u003cdiv\u003ePower Supply: 12 VDC adapter (included)\u003c\/div\u003e\n\u003cdiv\u003ePower Drivers: 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz\u003c\/div\u003e\n\u003cdiv\u003eMounting kit (Included)\u003c\/div\u003e\n\u003cdiv\u003eDimensions: 5.9 x 3.2 x 1.35 inches (148.5 x 82.5 x 32 mm)\u003c\/div\u003e\n\u003cdiv\u003eWeight: 6.3 ounces (180 g) (meter only)\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56101891342709,"sku":"MC310","price":138.06,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/MC310_includes-EURO_1920x1920_68e632e2-c3aa-4358-983e-6b0de041e561.jpg?v=1760530683"},{"product_id":"milwaukee-mc720-pro-ph-controller-and-pump-kit","title":"Milwaukee MC720 PRO pH Controller and Pump Kit","description":"\u003cdiv class=\"offcanvas-content-container\"\u003e\n\u003cdiv class=\"product-detail-description tab-pane-container\"\u003e\n\u003cdiv class=\"product-detail-description-text\" itemprop=\"description\"\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003eMilwaukee MC720 PRO pH Controller and Dosing Pump Kit – Automated pH Control for Healthier Systems\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eIn any environment where water chemistry needs to be tightly controlled – such as hydroponics, aquariums, horticultural systems, or aquaculture tanks – maintaining a stable pH is critical to the success of your setup. Fluctuations can affect nutrient availability, water quality, and the health of plants or aquatic life. That’s where the \u003cb\u003eMilwaukee MC720 PRO pH Controller and Dosing Pump Kit\u003c\/b\u003e comes in.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis professional-grade kit combines the reliable MC122 pH controller with the powerful MP810 peristaltic dosing pump, offering a hands-free solution for pH regulation. Whether you’re managing a high-demand hydroponic grow room or maintaining pH-sensitive aquatic habitats, the MC720 PRO continuously monitors your water and automatically doses a pH adjuster to keep your levels where they need to be – day and night, without interruption.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eTake the Guesswork Out of pH Management\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith real-time monitoring and automatic dosing, the MC720 PRO transforms reactive maintenance into proactive control. The included pH probe, controller, and pump work together to help you avoid sudden shifts in pH that could damage your system. This is particularly valuable in hydroponic nutrient tanks or aquariums with CO₂ injection, where even minor changes can lead to imbalances.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDesigned with durability and ease of use in mind, the MC720 PRO is ideal for both professionals and serious hobbyists. It includes everything you need for installation: wall-mount-ready hardware, BNC-connected pH electrode, calibration solutions, and flexible tubing for dosing. This is not just a controller – it's a daily partner in maintaining ideal growing or living conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eWhy Choose the Milwaukee MC720 PRO?\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eAutomatic pH Control\u003c\/b\u003e – Continuously monitors your pH levels and activates the dosing pump when needed to keep your water chemistry within the desired range.\u003cbr\u003e• \u003cb\u003eTrusted Performance\u003c\/b\u003e – Built on the reliable MC122 pH controller and MP810 dosing pump, both proven in professional setups worldwide.\u003cbr\u003e• \u003cb\u003eHands-Free Operation\u003c\/b\u003e – Ideal for busy growers and aquarists who need consistent results without constant oversight.\u003cbr\u003e• \u003cb\u003eSimple Setup\u003c\/b\u003e – Includes everything you need to get started: pH controller, dosing pump, MA911B\/2 double junction pH electrode, 12V power supplies, calibration solutions, and tubing.\u003cbr\u003e• \u003cb\u003ePrecise and Adjustable\u003c\/b\u003e – Set your target pH range and let the system do the rest, automatically correcting deviations with dosing accuracy.\u003cbr\u003e• \u003cb\u003eWide Application Use\u003c\/b\u003e – Perfect for hydroponics, horticulture, aquariums, aquaculture systems, and anywhere that requires stable pH control.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHydroponics and Nutrient Tanks\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIn hydroponic systems, maintaining precise pH levels is crucial for nutrient uptake. The MC720 PRO automates pH adjustments, ensuring optimal conditions for plant growth. Its peristaltic pump delivers accurate dosing, making it ideal for hydroponic nutrient tanks.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eAquariums and Aquaculture\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eFor aquariums, especially those with CO₂ injection systems, and aquaculture setups, stable pH levels are vital for aquatic life health. The MC720 PRO provides continuous pH monitoring and automatic adjustments, safeguarding fish and coral environments.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHorticulture and Fertilization Systems\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIn horticultural practices, especially those involving fertigation, the MC720 PRO ensures that the pH of fertilization solutions remains within the desired range, promoting efficient nutrient absorption and plant health.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOverall, the Milwaukee MC720 PRO is a versatile tool suitable for any application requiring consistent and automated pH control in aqueous solutions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eProper Care \u0026amp; Maintenance\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eTo ensure long-term accuracy and reliable performance of your \u003cb\u003eMilwaukee MC720 PRO pH Controller and Dosing Pump Kit\u003c\/b\u003e, proper care of the pH probe and dosing system is essential. Most performance issues in pH meters arise from the electrode – specifically the glass sensing bulb and the reference junction – so regular maintenance can significantly extend the life of your equipment.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eUnderstanding the Probe\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSensing Bulb\u003c\/b\u003e: The glass bulb is responsible for detecting pH changes. Over time, it naturally loses sensitivity and will eventually need replacement. This is a normal part of all pH probe lifecycles.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eReference Junction\u003c\/b\u003e: This small porous junction allows electrical contact between the reference solution and the sample. If the junction becomes clogged, the probe can no longer provide accurate readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Extend Electrode Life\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate Regularly\u003c\/b\u003e: Perform two-point calibrations with quality pH buffer solutions (pH 7.01 and 4.01) to maintain precision.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eClean the Electrode\u003c\/b\u003e: Rinse the probe with distilled water after each use. Periodically clean it using proper cleaning solutions to remove buildup that can clog the junction or coat the sensing bulb.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eStore Properly\u003c\/b\u003e: Always keep the pH electrode moist. Never let it dry out, as this can permanently damage the sensing bulb and clog the reference junction.\u003c\/li\u003e\n\u003cul type=\"circle\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level2 lfo2; tab-stops: list 72.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eUse the Right Solution\u003c\/b\u003e: Store the probe in pH electrode storage solution (MA9015) or a pH 4.01 calibration buffer. \u003ci\u003eNever\u003c\/i\u003e store in distilled or tap water, which can degrade the probe’s performance.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level2 lfo2; tab-stops: list 72.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eUse the Cap\u003c\/b\u003e: Fill the probe’s cap with storage solution or buffer and tighten it securely to prevent evaporation. Ideally, store the electrode upright to minimize leakage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli style=\"mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eInspect Tubing and Pump\u003c\/b\u003e: Check the dosing pump tubing periodically for wear or buildup. Replace tubing as needed to ensure consistent and accurate pH adjustment.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eEnsure Secure Installation\u003c\/b\u003e: Mount the controller and pump securely in a location protected from excessive humidity and splashing to prevent electrical or mechanical issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWith regular maintenance and proper handling, your Milwaukee MC720 PRO will deliver reliable, automated pH control for years to come – helping you maintain optimal water quality with minimal manual intervention.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTake control of your water chemistry and gain peace of mind with the Milwaukee MC720 PRO – a \u003cb\u003esmart, fully automated solution designed to maintain optimal pH levels\u003c\/b\u003e around the clock. Whether you're growing nutrient-hungry plants in a hydroponic system or caring for delicate aquatic life, the \u003cb\u003eMC720 PRO ensures consistency, reduces manual work, and protects your long-term investment in water quality\u003c\/b\u003e. Precision, reliability, and ease – working together so your system can thrive.\u003c\/p\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"specification-tab-pane\" role=\"tabpanel\" aria-labelledby=\"specification-tab\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eMC122 SPECIFICATIONS\u003c\/h3\u003e\n\u003cdiv\u003eRange: 0.0 - 14.0 pH\u003c\/div\u003e\n\u003cdiv\u003eResolution: 0.1 pH\u003c\/div\u003e\n\u003cdiv\u003eAccuracy: ±0.2 pH\u003c\/div\u003e\n\u003cdiv\u003eSet point: 5.5 to 9.5 pH\u003c\/div\u003e\n\u003cdiv\u003eCalibration: Manual 2 points\u003c\/div\u003e\n\u003cdiv\u003eAlarm Active when reading is higher or lower than set point\u003c\/div\u003e\n\u003cdiv\u003eDosing Contact: 1 power plug for CO2 dosing\u003c\/div\u003e\n\u003cdiv\u003epH electrode: MA911B\/2 (included)\u003c\/div\u003e\n\u003cdiv\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/div\u003e\n\u003cdiv\u003ePower Supply: 12 VDC adapter (included)\u003c\/div\u003e\n\u003cdiv\u003ePower Drivers: 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz\u003c\/div\u003e\n\u003cdiv\u003eMounting kit (Included)\u003c\/div\u003e\n\u003cdiv\u003eDimensions: 5.9 x 3.2 x 1.35 inches\u003c\/div\u003e\n\u003cdiv\u003eWeight: 6.3 ounces (meter only)\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eMP810 SPECIFICATIONS\u003c\/h3\u003e\n\u003cdiv\u003eMax. Flow: 0.6 L\/h\u003c\/div\u003e\n\u003cdiv\u003eMax. Pressure: 1.5 bar\u003c\/div\u003e\n\u003cdiv\u003eSqueeze tubing: Santoprene\u003c\/div\u003e\n\u003cdiv\u003eExt. Tube connection: 6 mm\u003c\/div\u003e\n\u003cdiv\u003ePower supply: 240 VAC, 50-60 Hz or 110 VAC, 60 Hz\u003c\/div\u003e\n\u003cdiv\u003ePower consumption: 0.42 W\u003c\/div\u003e\n\u003cdiv\u003eDimensions: 100 x 106 x 108 mm\u003c\/div\u003e\n\u003cdiv\u003eWeight: 17.6 oz.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"application-tab-pane\" role=\"tabpanel\" aria-labelledby=\"application-tab\"\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eHydroponics and Nutrient Tanks\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn hydroponic systems, plants rely entirely on nutrient-rich water instead of soil to absorb the essential elements they need for growth. However, nutrient uptake is heavily influenced by the pH of the solution. If the pH drifts outside the optimal range – typically between 5.5 and 6.5 – many nutrients become unavailable to the plants, even if they are present in the water. This can lead to nutrient deficiencies, stunted growth, or poor yields.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC720 PRO pH Controller and Dosing Pump Kit\u003c\/b\u003e solves this challenge by automatically monitoring and adjusting the pH in your nutrient tank. The MC122 controller continuously measures the pH level in real-time using a professional-grade electrode. When the pH strays from your set target range, the MP810 dosing pump is triggered to deliver a precise amount of pH-adjusting solution (usually a pH down acid) directly into the reservoir.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis hands-free automation prevents fluctuations, eliminates the need for constant manual testing and corrections, and helps maintain the stable environment plants need to thrive. It's especially useful in recirculating systems, where pH can shift quickly due to nutrient absorption and microbial activity.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're growing leafy greens, herbs, tomatoes, or cannabis, the MC720 PRO ensures your hydroponic system runs smoothly with consistent pH control – maximizing plant health, nutrient absorption, and productivity.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC720 PRO in Hydroponics\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eInstall the pH Controller\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l19 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMount the \u003cb\u003eMC122 pH Controller\u003c\/b\u003e on a wall or stable surface near your nutrient tank. Avoid placing it in a high-humidity or splash-prone area.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l19 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eConnect the \u003cb\u003eMA911B\/2 pH electrode\u003c\/b\u003e to the controller and insert the probe into your nutrient reservoir or a recirculating line using a probe holder or grommet.\u003c\/p\u003e\n\u003col type=\"1\" start=\"2\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eConnect the Dosing Pump\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l16 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMount the \u003cb\u003eMP810 peristaltic pump\u003c\/b\u003e securely.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l16 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eInsert one end of the included tubing into a container of \u003cb\u003epH-adjusting solution\u003c\/b\u003e (commonly pH Down). Insert the other end into your nutrient reservoir.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l16 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMake sure the pump tubing is securely connected and free of air bubbles or blockages.\u003c\/p\u003e\n\u003col type=\"1\" start=\"3\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eSet Your Desired pH Range\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l15 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoListParagraph\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse the controller’s dial to set the lower and upper pH limits. When the pH goes above this range, the controller will activate the pump to deliver acid to lower the pH.\u003c\/p\u003e\n\u003col type=\"1\" start=\"4\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eCalibrate the pH Probe\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l10 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePerform a \u003cb\u003etwo-point calibration\u003c\/b\u003e using pH 7.01 and 4.01 buffer solutions. This ensures accurate readings.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l10 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRepeat calibration regularly based on usage frequency (weekly in high-use systems).\u003c\/p\u003e\n\u003col type=\"1\" start=\"5\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003ePower On and Monitor\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l6 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePlug in both the controller and the dosing pump using the included 12V power supplies.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l6 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMonitor the LCD display on the MC122 to check current pH readings. The system will automatically adjust the pH as needed within your set range.\u003c\/p\u003e\n\u003col type=\"1\" start=\"6\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eRegular Maintenance\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l7 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRefill your pH solution container as needed.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l7 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eClean the electrode regularly and store it properly when not in use.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l7 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eInspect tubing for wear and replace it if necessary.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the MC720 PRO, maintaining ideal pH conditions in hydroponics becomes easy, accurate, and automated – so you can focus on growing, not troubleshooting. Let your plants enjoy uninterrupted nutrient access and deliver the yields you’re aiming for.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eAquariums and Aquaculture\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn both aquariums and aquaculture systems, maintaining a \u003cb\u003estable pH\u003c\/b\u003e is essential for the health, behavior, and survival of aquatic life. Fish, corals, crustaceans, and beneficial microorganisms are all sensitive to pH fluctuations. Even minor, frequent swings can lead to stress, disease, poor growth, or even death.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eSaltwater and reef aquariums, in particular, require \u003cb\u003etight pH control\u003c\/b\u003e, typically between 8.1 and 8.4, especially in systems with \u003cb\u003eCO₂ injection for planted tanks or calcium reactors\u003c\/b\u003e. In freshwater aquariums or breeding tanks, stable and species-specific pH levels support proper development and reduce aggressive behavior or reproductive issues.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn aquaculture – whether for fish farming or shellfish cultivation – water quality is directly tied to productivity. pH shifts can impact oxygen levels, ammonia toxicity, and metabolic function in aquatic animals, ultimately affecting your yields and profitability.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC720 PRO\u003c\/b\u003e ensures around-the-clock monitoring and pH adjustment through a reliable, automated system. The \u003cb\u003eMC122 controller\u003c\/b\u003e tracks pH in real time, while the \u003cb\u003eMP810 dosing pump\u003c\/b\u003e adds acid or base as needed to maintain your desired pH range. This eliminates the guesswork, reduces manual intervention, and helps create a consistently healthy aquatic environment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're running a home reef tank, a professional breeding system, or a commercial aquaculture facility, the MC720 PRO helps protect your aquatic investment with precision and peace of mind.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC720 PRO in Aquariums and Aquaculture\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l4 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eSet Up the pH Controller\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l8 level1 lfo14; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMount the \u003cb\u003eMC122 pH controller\u003c\/b\u003e in a dry, splash-protected area near your aquarium or sump.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l8 level1 lfo14; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eConnect the \u003cb\u003eMA911B\/2 pH probe\u003c\/b\u003e to the controller and place it securely in your tank or sump using a probe holder or suction cup. Avoid positioning it near CO₂ injection or dosing points to prevent false readings.\u003c\/p\u003e\n\u003col type=\"1\" start=\"2\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l4 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eInstall the Dosing Pump\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l13 level1 lfo13; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMount the \u003cb\u003eMP810 pump\u003c\/b\u003e nearby on a secure surface.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l13 level1 lfo13; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eAttach the input tubing to your pH-adjusting solution (e.g., a \u003cb\u003ebuffer\u003c\/b\u003e or \u003cb\u003eacid\/base solution\u003c\/b\u003e depending on whether you need to raise or lower pH).\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l13 level1 lfo13; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePlace the output tubing into your sump or return section – somewhere with high water flow for even distribution.\u003c\/p\u003e\n\u003col type=\"1\" start=\"3\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l4 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eCalibrate the pH Probe\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l20 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePerform a \u003cb\u003etwo-point calibration\u003c\/b\u003e using fresh pH 7.01 and 4.01 buffer solutions.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l20 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCalibration is essential for accurate pH readings and should be done at least monthly or whenever readings seem inconsistent.\u003c\/p\u003e\n\u003col type=\"1\" start=\"4\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l4 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eSet Your Desired pH Range\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l0 level1 lfo11; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse the dial on the MC122 controller to define your ideal pH range (for example, 8.2 as your target in a reef aquarium).\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l0 level1 lfo11; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eWhen the pH drifts outside of this range, the controller activates the pump to dose your correction fluid and bring pH back in line.\u003c\/p\u003e\n\u003col type=\"1\" start=\"5\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l4 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003ePower On and Monitor\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l3 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePlug in the controller and pump. Monitor the live pH readings on the LCD display.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l3 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eThe system will automatically maintain your set pH range without manual adjustments.\u003c\/p\u003e\n\u003col type=\"1\" start=\"6\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l4 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eRoutine Maintenance\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l18 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eKeep the probe clean by rinsing with distilled water and storing it in \u003cb\u003estorage solution\u003c\/b\u003e (MA9015) when not in use.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l18 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eInspect and replace dosing tubing as needed to prevent clogging or wear.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l18 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRefill your pH adjustment solution as necessary.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l18 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRecalibrate the probe regularly for best results.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the Milwaukee MC720 PRO, aquarium and aquaculture enthusiasts gain a powerful tool for maintaining the water quality their aquatic life depends on. By automating pH control, you reduce stress on your livestock, support biological balance, and avoid the headaches of manual dosing.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eHorticulture and Fertilization Systems\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn professional horticulture, particularly in \u003cb\u003efertigation systems\u003c\/b\u003e where nutrients are delivered via irrigation, maintaining the correct pH of the nutrient solution is crucial. pH affects the \u003cb\u003esolubility and availability of essential nutrients\u003c\/b\u003e – a solution that is too acidic or too alkaline can lock out key elements like nitrogen, phosphorus, or potassium, leading to \u003cb\u003enutrient deficiencies\u003c\/b\u003e, \u003cb\u003estunted growth\u003c\/b\u003e, and \u003cb\u003ereduced crop yield\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDifferent crops have optimal pH ranges (commonly between \u003cb\u003e5.5 and 6.5\u003c\/b\u003e), and even small deviations can significantly impact plant performance. Manual pH adjustment in large-scale systems is not only time-consuming, but also inconsistent – especially when water quality fluctuates or when fertilizer recipes change.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC720 PRO\u003c\/b\u003e takes the guesswork out of pH management in fertigation. This system includes the \u003cb\u003eMC122 pH controller\u003c\/b\u003e, which continuously monitors the pH of your fertilization tank or irrigation line, and the \u003cb\u003eMP810 dosing pump\u003c\/b\u003e, which adds acid (or base) automatically to correct any drift outside your set range.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis automation leads to more \u003cb\u003euniform nutrient delivery\u003c\/b\u003e, \u003cb\u003eimproved uptake\u003c\/b\u003e, and \u003cb\u003ehealthier plants\u003c\/b\u003e, making it a valuable tool for greenhouses, nurseries, vertical farms, and field-scale fertigation systems.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC720 PRO in Horticulture and Fertigation Systems\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l12 level1 lfo15; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e1.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eMount the pH Controller\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l5 level1 lfo21; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eInstall the \u003cb\u003eMC122 controller\u003c\/b\u003e in a dry location near your fertigation mixing tank or dosing panel.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l5 level1 lfo21; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eConnect the \u003cb\u003eMA911B\/2 pH probe\u003c\/b\u003e and place it into the tank or directly into a flow-through cell on your irrigation line for continuous measurement.\u003c\/p\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l12 level1 lfo15; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e2.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eInstall the Dosing Pump\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l1 level1 lfo20; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eSecure the \u003cb\u003eMP810 pump\u003c\/b\u003e near the controller.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l1 level1 lfo20; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eConnect the \u003cb\u003einput tube\u003c\/b\u003e to your acid solution (commonly phosphoric or nitric acid) or base solution, depending on your water source and target pH.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l1 level1 lfo20; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePlace the \u003cb\u003eoutput tube\u003c\/b\u003e into the mixing tank or inline dosing point.\u003c\/p\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l12 level1 lfo15; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e3.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eCalibrate the pH Probe\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l9 level1 lfo19; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePerform a \u003cb\u003etwo-point calibration\u003c\/b\u003e with pH 7.01 and 4.01 buffer solutions.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l9 level1 lfo19; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRecalibrate regularly (e.g., weekly or bi-weekly) to maintain precision in environments with high fertilizer concentrations.\u003c\/p\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l12 level1 lfo15; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e4.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eSet the Target pH\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l11 level1 lfo18; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse the dial on the MC122 to set your target pH value, such as \u003cb\u003e5.8 for tomatoes\u003c\/b\u003e or \u003cb\u003e6.0 for leafy greens\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l11 level1 lfo18; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eThe controller will activate the pump to add acid\/base automatically when the pH drifts beyond your set value.\u003c\/p\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l12 level1 lfo15; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e5.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eBegin Operation\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l17 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePower on the system and monitor the live pH readings on the MC122 display.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l17 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eThe MC720 PRO will continuously maintain your desired pH range, adjusting in real-time as irrigation and fertilization cycles run.\u003c\/p\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l12 level1 lfo15; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e6.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eMaintain the System\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l14 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRinse the probe with distilled water and store in \u003cb\u003eMA9015 storage solution\u003c\/b\u003e when not in use.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l14 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eInspect the tubing for wear, and replace as needed to ensure precise chemical delivery.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l14 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eKeep the acid\/base solution container filled and secure.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l14 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCheck calibration routinely, especially after cleaning or heavy system use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBy integrating the Milwaukee MC720 PRO into your horticultural fertilization system, you can automate a critical variable – \u003cb\u003epH control\u003c\/b\u003e – that directly affects crop quality and yield. This not only saves time and labor but also enhances consistency, giving you healthier plants and more predictable results season after season.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56106054451573,"sku":"MC720KIT","price":348.19,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/MC122_incl-EUROcopy_1920x1920_5dbcff71-ac0f-4c6d-8d8a-723c5c8fe8a1.jpg?v=1760604097"},{"product_id":"milwaukee-mc120-pro-ph-monitor","title":"Milwaukee MC120 PRO pH Monitor","description":"\u003cdiv class=\"offcanvas-content-container\"\u003e\n\u003cdiv class=\"product-detail-description tab-pane-container\"\u003e\n\u003cdiv class=\"product-detail-description-text\" itemprop=\"description\"\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003eMilwaukee MC120 PRO pH Monitor – Reliable 24\/7 pH Monitoring for Stable Water Conditions\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eIn any application where water chemistry matters – hydroponics, aquariums, pools, or industrial water systems – keeping pH levels in check is crucial. Sudden shifts can throw off nutrient availability, stress aquatic life, or disrupt chemical balance. That’s where the \u003cb\u003eMilwaukee MC120 PRO\u003c\/b\u003e comes in: a compact, continuous pH monitoring solution built for users who need \u003cb\u003eround-the-clock reliability\u003c\/b\u003e and \u003cb\u003efast response times\u003c\/b\u003e – without the complexity of lab-grade instruments.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you’re managing a hydroponic nutrient reservoir, fine-tuning the pH of an aquaculture tank, or ensuring water stability in industrial settings, the MC120 PRO delivers peace of mind. With a clear digital display, real-time high and low pH alarms, and a durable double-junction probe, this unit offers professional-level monitoring in a user-friendly format. It’s trusted by hobbyists and professionals alike who need to monitor pH directly in the water – no constant testing, no guesswork.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe MC120 PRO is designed to be permanently installed, with everything you need included – mounting hardware, adapter, and a replaceable probe. Set it up once and let it keep an eye on your system, so you can focus on what really matters: results.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eWhy Choose the Milwaukee MC120 PRO?\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eContinuous pH Monitoring\u003c\/b\u003e: Offers real-time tracking of pH values directly in your reservoir, aquarium, or water system – 24\/7.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eBuilt-In Alarm System\u003c\/b\u003e: Customizable high and low set points trigger a flashing LED when your pH drifts out of range, giving you time to respond before it becomes a problem.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eLab-Grade Accuracy\u003c\/b\u003e: ±0.2 pH accuracy across a 0.0 to 14.0 range with two-point manual calibration ensures precise, dependable readings.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eDouble Junction Electrode\u003c\/b\u003e: The included MA911B\/2 pH probe is gel-filled and double-junction for enhanced durability and longer life – even in dirty or nutrient-rich water.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSimple Installation\u003c\/b\u003e: Comes with a 12 VDC adapter and mounting kit for quick setup in fixed locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\n\u003cb\u003eApplications\u003c\/b\u003e:\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1. Aquariums (Freshwater \u0026amp; Saltwater)\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpFirst\" style=\"margin-left: 18.0pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l0 level1 lfo5;\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eDesigned for \u003cb\u003eprofessional aquarium use\u003c\/b\u003e, including reef setups, to maintain ideal pH and alert on deviations.\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"margin-left: 18.0pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l0 level1 lfo5;\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eFrequently used by hobbyists, with reviews praising its reliability (“spot on” readings for reef tanks).\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2. Hydroponics \u0026amp; Recirculating Farming\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpFirst\" style=\"margin-left: 18.0pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l5 level1 lfo6;\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eIdeal for monitoring nutrient solution pH in hydroponic or reservoir systems – designed to \"continuously monitor pH … directly in your reservoir”.\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"margin-left: 18.0pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l5 level1 lfo6;\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eFits into “PRO Monitors” lineup for pH\/EC\/TDS control in plant growth environments.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3. Laboratory \u0026amp; Industrial Water Quality\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpFirst\" style=\"margin-left: 18.0pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l1 level1 lfo3;\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eProvides \u003cb\u003elab-grade accuracy\u003c\/b\u003e of ±0.2\u003cspan style=\"font-family: 'Arial',sans-serif;\"\u003e \u003c\/span\u003epH across 0\u003cspan style=\"mso-ascii-font-family: Aptos; mso-hansi-font-family: Aptos; mso-bidi-font-family: Aptos;\"\u003e–\u003c\/span\u003e14\u003cspan style=\"font-family: 'Arial',sans-serif;\"\u003e \u003c\/span\u003erange, suitable for basic water quality checks in R\u0026amp;D or industrial settings.\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"margin-left: 18.0pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l1 level1 lfo3;\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCompact size, continuous reading, and alarm features make it suitable for small-scale industrial monitoring.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e4. Educational \u0026amp; Teaching Setups\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 18.0pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l3 level1 lfo4;\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eDurable double‑junction electrode and simple 12\u003cspan style=\"font-family: 'Arial',sans-serif;\"\u003e \u003c\/span\u003eVDC powered design makes it suitable for schools and universities for teaching water chemistry with continuous monitoring.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCore Features Supporting These Applications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpFirst\" style=\"margin-left: 18.0pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l3 level1 lfo4;\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eContinuous 24\/7 monitoring with user-defined high\/low pH alarms via LED flash.\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"margin-left: 18.0pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l3 level1 lfo4;\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eWide range (0–14\u003cspan style=\"font-family: 'Arial',sans-serif;\"\u003e \u003c\/span\u003epH), manual two‑point calibration, lab‑grade double‑junction electrode.\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"margin-left: 18.0pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l3 level1 lfo4;\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eIncludes mounting hardware and AC adapter – ideal for permanent setups\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eProper Care \u0026amp; Maintenance\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eTo get the best performance and longest life out of your MC120 PRO pH Monitor:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eCalibrate Regularly\u003c\/b\u003e: Use pH 7.01 and 4.01 (or 10.01) buffer solutions for manual two-point calibration to keep measurements accurate.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eClean the Probe\u003c\/b\u003e: Rinse the pH electrode with distilled water after each use and periodically clean with a pH probe cleaning solution.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eStore Properly\u003c\/b\u003e: When not in use, keep the electrode tip in a proper storage solution (not dry) to prevent membrane damage.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eCheck for Wear\u003c\/b\u003e: Over time, probe performance may degrade—replace the electrode as needed to maintain reliable readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; line-height: 115%; font-family: 'Aptos',sans-serif; mso-ascii-theme-font: minor-latin; mso-fareast-font-family: Aptos; mso-fareast-theme-font: minor-latin; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi; mso-ansi-language: HU; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;\"\u003eTake control of your water chemistry with the Milwaukee MC120 PRO\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; line-height: 115%; font-family: 'Aptos',sans-serif; mso-ascii-theme-font: minor-latin; mso-fareast-font-family: Aptos; mso-fareast-theme-font: minor-latin; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi; mso-ansi-language: HU; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;\"\u003e—your dependable partner for fixed-location pH monitoring. Simple, accurate, and built to last, it’s the perfect solution for serious growers, aquarists, and anyone who values precision in water management\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-detail-description-text\" itemprop=\"description\"\u003e\n\u003cspan style=\"font-size: 12.0pt; line-height: 115%; font-family: 'Aptos',sans-serif; mso-ascii-theme-font: minor-latin; mso-fareast-font-family: Aptos; mso-fareast-theme-font: minor-latin; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi; mso-ansi-language: HU; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-detail-description-text\" itemprop=\"description\"\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"specification-tab-pane\" role=\"tabpanel\" aria-labelledby=\"specification-tab\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003epH Range: 0.0 - 14.0 pH\u003c\/div\u003e\n\u003cdiv\u003epH Resolution: 0.1 pH\u003c\/div\u003e\n\u003cdiv\u003epH Accuracy: ± 0.2 pH\u003c\/div\u003e\n\u003cdiv\u003eCalibration: Manual 2 points\u003c\/div\u003e\n\u003cdiv\u003eSetpoint range: 5.5 to 9.5 pH\u003c\/div\u003e\n\u003cdiv\u003eAlarm Active: when reading is higher or lower than set point\u003c\/div\u003e\n\u003cdiv\u003epH Electrode: MA911B\/2 (included)\u003c\/div\u003e\n\u003cdiv\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/div\u003e\n\u003cdiv\u003ePower Supply: 12 VDC adapter (included)\u003c\/div\u003e\n\u003cdiv\u003eDimensions: 5.9 x 3.2 x 1.35 inches\u003c\/div\u003e\n\u003cdiv\u003eWeight: 6.3 ounces (meter only)\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"application-tab-pane\" role=\"tabpanel\" aria-labelledby=\"application-tab\"\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eAquariums (Freshwater \u0026amp; Saltwater)\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eMaintaining stable pH is critical for the health and longevity of aquatic life. In both freshwater and saltwater aquariums – especially in sensitive environments like reef tanks – fluctuations in pH can lead to stress, illness, or even death in fish, corals, and invertebrates. The Milwaukee MC120 PRO provides an ideal solution for aquarists who need \u003cb\u003econstant, accurate pH monitoring without the hassle of daily manual testing\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe unit is frequently praised by aquarium hobbyists and professionals for its \u003cb\u003e\"set it and forget it\" reliability\u003c\/b\u003e. By continuously displaying the pH value and triggering visual alarms if the reading goes out of the desired range, the MC120 PRO allows users to act before problems arise – whether due to CO₂ swings, overfeeding, equipment malfunctions, or water chemistry imbalances.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis monitor is especially valuable in:\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l3 level1 lfo1;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eReef tanks\u003c\/b\u003e, where pH stability directly affects coral health and calcification.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l3 level1 lfo1;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eCO₂-injected planted tanks\u003c\/b\u003e, where tight control is needed to avoid acidification.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l3 level1 lfo1;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eFish breeding systems\u003c\/b\u003e, where consistent pH supports reproductive health and fry development.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l3 level1 lfo1;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eAquaculture operations\u003c\/b\u003e, where water quality directly impacts productivity.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC120 PRO in an Aquarium Setting\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1. Mount the Monitor\u003c\/b\u003e\u003cbr\u003e• Choose a stable, dry location near your tank or sump to mount the MC120 using the included bracket.\u003cbr\u003e• Ensure the display is easily visible so you can monitor pH levels at a glance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2. Connect the Probe\u003c\/b\u003e\u003cbr\u003e• Insert the MA911B\/2 double-junction pH probe into the BNC connector on the monitor.\u003cbr\u003e• Secure the probe in the aquarium or sump using a probe holder or suction mount, ensuring it stays submerged at all times. Avoid placing it near return nozzles or areas with air bubbles to prevent inaccurate readings.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3. Power Up\u003c\/b\u003e\u003cbr\u003e• Plug in the 12 VDC power adapter. The monitor will immediately begin displaying real-time pH values.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e4. Calibrate the Unit\u003c\/b\u003e\u003cbr\u003e• Perform a two-point manual calibration using fresh pH 7.01 and pH 4.01 (or 10.01) buffer solutions.\u003cbr\u003e• Follow the user manual instructions to adjust the calibration trimmers until the correct values are shown.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e5. Set the Alarm Range\u003c\/b\u003e\u003cbr\u003e• Define your ideal pH range (e.g., 7.8–8.3 for a reef tank) using the front panel high\/low adjustment knobs.\u003cbr\u003e• If pH falls outside this range, the LED alarm will flash to alert you.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6. Regular Maintenance\u003c\/b\u003e\u003cbr\u003e• Rinse the probe with distilled water weekly.\u003cbr\u003e• Keep the probe submerged at all times during use.\u003cbr\u003e• Calibrate monthly or as needed to maintain accuracy.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the MC120 PRO, aquarists no longer have to rely solely on manual testing kits or worry about silent pH swings. It provides an \u003cb\u003eextra layer of protection\u003c\/b\u003e, helping you create a healthier, more stable environment for your aquatic life.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eHydroponics \u0026amp; Recirculating Farming\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn hydroponics and recirculating farming systems, pH is one of the most critical variables affecting \u003cb\u003enutrient uptake\u003c\/b\u003e and \u003cb\u003eplant health\u003c\/b\u003e. Even slight imbalances can lock out key nutrients, slow down growth, or cause deficiencies and toxicity. The \u003cb\u003eMilwaukee MC120 PRO\u003c\/b\u003e is designed to \u003cb\u003econtinuously monitor the pH of your nutrient solution in real time\u003c\/b\u003e, providing an efficient and proactive way to manage your growing environment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eUnlike handheld testers or test kits that require manual measurements, the MC120 PRO is installed directly into your system – typically in the nutrient reservoir or a recirculating flow area – allowing growers to maintain optimal pH without daily checks. If the pH drifts out of the desired range (due to nutrient additions, biological activity, or water evaporation), the built-in high\/low pH alarm alerts you immediately.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis tool is particularly valuable for:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCommercial hydroponic growers\u003c\/b\u003e managing large or multi-bay systems.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSmall-scale and home growers\u003c\/b\u003e looking to improve consistency and reduce labor.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eRecirculating aquaponic systems\u003c\/b\u003e, where fish waste affects pH and plant nutrient availability.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eAutomated setups\u003c\/b\u003e, where the MC120 can be paired with dosing pumps for real-time adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWith consistent pH control, plants can absorb nutrients more efficiently, grow faster, and produce higher yields – making the MC120 PRO an essential part of any precision farming setup.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC120 PRO in Hydroponic Systems\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1. Mount the Monitor\u003c\/b\u003e\u003cbr\u003e• Choose a protected location near your reservoir or grow system to mount the MC120 using the included bracket.\u003cbr\u003e• Position the display so it’s visible during system checks or nutrient adjustments.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2. Install the pH Electrode\u003c\/b\u003e\u003cbr\u003e• Connect the MA911B\/2 pH probe to the monitor using the BNC connector.\u003cbr\u003e• Submerge the probe directly into the nutrient reservoir or in a return flow chamber.\u003cbr\u003e• Use a probe holder or grommet to keep the probe securely in place and fully immersed at all times.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3. Power the Monitor\u003c\/b\u003e\u003cbr\u003e• Plug the unit into a standard outlet using the included 12 VDC power adapter.\u003cbr\u003e• The monitor will instantly begin displaying the real-time pH level of your solution.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e4. Calibrate for Accuracy\u003c\/b\u003e\u003cbr\u003e• Perform a two-point calibration with fresh pH 7.01 and 4.01 (or 10.01) buffer solutions.\u003cbr\u003e• Adjust the trimmers on the monitor to match the solution values. Repeat regularly for best performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e5. Set the pH Alarm Range\u003c\/b\u003e\u003cbr\u003e• Use the high\/low setpoint dials to define your ideal pH range (e.g., 5.5 to 6.5 for most crops).\u003cbr\u003e• If the nutrient solution moves outside this range, the flashing LED alarm will alert you to take action.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6. Maintain the Probe\u003c\/b\u003e\u003cbr\u003e• Rinse the probe with distilled water weekly to prevent buildup from fertilizers.\u003cbr\u003e• Avoid allowing the probe to dry out – store it in proper storage solution when not in use for long periods.\u003cbr\u003e• Calibrate monthly or more frequently during intensive growing periods.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the \u003cb\u003eMilwaukee MC120 PRO\u003c\/b\u003e, growers can eliminate guesswork and manual testing from pH management. It brings \u003cb\u003eautomation and precision\u003c\/b\u003e to your hydroponic or recirculating farm, supporting healthier plants, better yields, and a more efficient growing process.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eLaboratory \u0026amp; Industrial Water Quality\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eAccurate and reliable pH monitoring plays a crucial role in laboratories and industrial settings – whether it’s for R\u0026amp;D, water treatment, chemical processing, or environmental compliance. The \u003cb\u003eMilwaukee MC120 PRO\u003c\/b\u003e is designed to meet these needs with \u003cb\u003elab-grade accuracy\u003c\/b\u003e and \u003cb\u003econtinuous monitoring\u003c\/b\u003e in a compact, easy-to-install format.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn research labs, maintaining the correct pH during chemical reactions, solution preparation, or biological experiments is essential for reproducibility and safety. In industrial environments, even small pH deviations can lead to corrosion, scaling, compromised product quality, or regulatory violations.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe MC120 PRO’s ±0.2 pH accuracy across a full 0.00 to 14.00 pH range makes it a dependable choice for:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eLaboratory testing stations\u003c\/b\u003e monitoring buffers, solutions, or treated water.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSmall-scale industrial processes\u003c\/b\u003e, such as plating, brewing, wastewater pretreatment, or cooling towers.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eQuality control points\u003c\/b\u003e, where continuous pH measurement adds an extra layer of assurance.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003ePilot plants or test environments\u003c\/b\u003e, where real-time data helps fine-tune chemical dosing or process parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eIts built-in LED alarm provides immediate visual feedback if the pH moves out of the acceptable range, helping teams react quickly to avoid system damage or downtime.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC120 PRO in Laboratory \u0026amp; Industrial Settings\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1. Mount the Monitor\u003c\/b\u003e\u003cbr\u003e• Install the MC120 in a dry, visible location near your testing area, bench station, or process tank using the included mounting bracket.\u003cbr\u003e• Ensure that staff can easily view the digital display and access the calibration trimmers when needed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2. Position the Probe\u003c\/b\u003e\u003cbr\u003e• Connect the MA911B\/2 double-junction pH probe to the monitor using the BNC connector.\u003cbr\u003e• Place the probe into the tank, sample chamber, or beaker where continuous pH monitoring is required. Use a clamp or holder to secure the probe and prevent shifting.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3. Power the Unit\u003c\/b\u003e\u003cbr\u003e• Plug in the included 12 VDC adapter. The monitor will begin displaying the real-time pH reading immediately.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e4. Calibrate for Precision\u003c\/b\u003e\u003cbr\u003e• Perform a two-point manual calibration using fresh buffer solutions (pH 7.01 and 4.01 or 10.01) depending on your measurement range.\u003cbr\u003e• Use the calibration trimmers on the front panel to adjust readings until they match the solution values.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e5. Set High\/Low Alarms\u003c\/b\u003e\u003cbr\u003e• Use the dials on the monitor to define your target pH limits.\u003cbr\u003e• If the measured pH moves outside this range, the LED warning will flash – prompting timely correction or intervention.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6. Routine Maintenance\u003c\/b\u003e\u003cbr\u003e• Rinse the probe with distilled water after each use, especially when measuring different chemical solutions.\u003cbr\u003e• Periodically clean the probe using an appropriate pH cleaning solution to remove buildup or residue.\u003cbr\u003e• Always store the pH electrode in proper storage solution when not in use to maintain its sensitivity.\u003cbr\u003e• Recalibrate regularly (weekly or monthly) depending on frequency of use and process criticality.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the \u003cb\u003eMilwaukee MC120 PRO\u003c\/b\u003e, laboratories and industrial users gain a \u003cb\u003ecost-effective, dependable solution\u003c\/b\u003e for real-time pH monitoring. Its accuracy, alarm system, and ease of installation make it a practical choice for applications where stability, compliance, and process efficiency are non-negotiable.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eEducational \u0026amp; Teaching Setups\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn classrooms, science labs, and university research programs, teaching students about water chemistry often involves hands-on experiments with \u003cb\u003ereal-time monitoring of pH levels\u003c\/b\u003e. The \u003cb\u003eMilwaukee MC120 PRO pH Monitor\u003c\/b\u003e is a practical, user-friendly tool that allows educators to introduce fundamental chemical principles while familiarizing students with professional-grade instrumentation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIts \u003cb\u003edurable double-junction electrode\u003c\/b\u003e, \u003cb\u003emanual calibration\u003c\/b\u003e, and \u003cb\u003econtinuous digital readout\u003c\/b\u003e make it ideal for:\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l0 level1 lfo4;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eHigh school chemistry labs teaching the basics of acids, bases, and buffer systems\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l0 level1 lfo4;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUniversity-level environmental science or biology courses monitoring water quality\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l0 level1 lfo4;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eTechnical schools or vocational training in fields like agriculture, aquaculture, or laboratory operations\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l0 level1 lfo4;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eDemonstrations in outreach programs or science fairs\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eUnlike more fragile or complex benchtop meters, the MC120 PRO is \u003cb\u003estraightforward to install\u003c\/b\u003e, easy to calibrate, and built to withstand repeated student use. The visual LED alarm adds an interactive learning element – making it easy for students to observe how pH levels change and respond to external variables like chemical additions or CO₂ exposure.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIt supports active learning, where measuring isn’t just a theory but a \u003cb\u003evisible, measurable process\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eHow to Use the MC120 PRO in Educational Environments\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1. Setup \u0026amp; Mounting\u003c\/b\u003e\u003cbr\u003e• Mount the unit on a lab wall, benchtop stand, or demonstration board using the included bracket.\u003cbr\u003e• Ensure the display is easily visible for group instruction or individual use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2. Connect the pH Probe\u003c\/b\u003e\u003cbr\u003e• Plug the MA911B\/2 double-junction electrode into the BNC connector.\u003cbr\u003e• Place the electrode into a sample container, beaker, or experimental setup.\u003cbr\u003e• Use a clamp or probe holder to keep the sensor stable and fully submerged.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3. Power Up\u003c\/b\u003e\u003cbr\u003e• Plug the unit into a standard outlet with the supplied 12 VDC adapter.\u003cbr\u003e• The monitor will begin showing the real-time pH level immediately.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e4. Calibration for Accuracy\u003c\/b\u003e\u003cbr\u003e• Perform a two-point manual calibration using fresh pH buffer solutions (commonly pH 7.01 and 4.01 or 10.01).\u003cbr\u003e• Let students observe the calibration process to understand how sensors are standardized.\u003cbr\u003e• Adjust the front panel calibration knobs to match buffer solution values.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e5. Set Alarm Thresholds\u003c\/b\u003e\u003cbr\u003e• Turn the high\/low dials to define an ideal pH range for the experiment (e.g., 6.0–8.0).\u003cbr\u003e• Use the LED alarm to help students visually understand pH drift during the experiment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6. Maintenance \u0026amp; Learning Practice\u003c\/b\u003e\u003cbr\u003e• Rinse the probe after each class or activity with distilled water.\u003cbr\u003e• Encourage students to record results over time and note how external factors affect pH.\u003cbr\u003e• Store the electrode tip in pH storage solution when not in use to preserve its accuracy.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBy incorporating the \u003cb\u003eMilwaukee MC120 PRO\u003c\/b\u003e into educational settings, instructors give students access to \u003cb\u003ereal-world tools\u003c\/b\u003e that reinforce theoretical knowledge with practical, visible results. It turns abstract chemistry concepts into interactive experiences – ideal for \u003cb\u003einspiring curiosity, encouraging scientific thinking, and preparing future professionals\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56106278912373,"sku":"MC120","price":138.06,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/1111_1920x1920_6c0e5b51-e91d-4d9f-a941-dc1731984be4.jpg?v=1760607304"},{"product_id":"milwaukee-mc110-pro-ph-monitor-mid-range","title":"Milwaukee MC110 PRO pH Monitor Mid Range","description":"\u003cdiv class=\"offcanvas-content-container\"\u003e\n\u003cdiv class=\"product-detail-description tab-pane-container\"\u003e\n\u003cdiv class=\"product-detail-description-text\" itemprop=\"description\"\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003eMilwaukee MC110 PRO pH Monitor Mid Range – Continuous Accuracy for Consistent Results\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eAchieving the perfect pH balance isn’t just a goal – it’s a necessity in many industries where water quality makes all the difference. Whether you’re nurturing a hydroponic system, running an aquarium, or operating a water treatment plant, stable pH levels are essential for success. That’s where the \u003cb\u003eMilwaukee MC110 PRO pH Monitor\u003c\/b\u003e comes in.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDesigned for continuous monitoring, the MC110 is a reliable, mid-range solution trusted by growers, aquarists, and professionals around the world. Featuring a large digital display, user-friendly calibration, and a replaceable, high-accuracy pH probe, this monitor delivers peace of mind – 24\/7. Say goodbye to manual spot checks and hello to real-time, stable monitoring.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith wall-mount capability and a clear visual alarm for out-of-range values, the MC110 is built to keep your system in check, even when you’re not watching. This monitor is perfect for users who need dependable and affordable pH control—without compromising on quality or performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eWhy Choose the Milwaukee MC110?\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eContinuous Monitoring\u003c\/b\u003e – Tracks pH levels in real-time for immediate response to changes.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eClear Visual Alarm\u003c\/b\u003e – Alerts you when pH levels fall outside your desired range.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003ePrecision Calibration\u003c\/b\u003e – Easy two-point manual calibration ensures accuracy over time.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eReplaceable Electrode\u003c\/b\u003e – Extends device life and reduces long-term costs.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMountable \u0026amp; Compact\u003c\/b\u003e – Ideal for tanks, nutrient reservoirs, and small labs.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eReliable Performance\u003c\/b\u003e – ±0.2 pH accuracy with a wide measuring range (0.0 – 14.0 pH).\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eDurable Design\u003c\/b\u003e – Built for continuous operation in demanding environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003e \u003c\/h2\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eApplications of the MC110 pH Monitor\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHydroponics \u0026amp; Horticulture\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIn hydroponic systems, even slight pH imbalances can affect nutrient uptake and stunt growth. The MC110 allows you to maintain consistent root-zone conditions for healthier plants and better yields. Monitor nutrient tanks effortlessly and respond quickly to pH shifts to keep your crops thriving.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eAquariums \u0026amp; Aquaculture\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eAquatic environments are sensitive to pH changes, especially in reef tanks or fish farms. The MC110 gives aquarists and fish farmers real-time monitoring to protect aquatic life, improve breeding conditions, and prevent pH-related health issues.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eLaboratory \u0026amp; Education\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eUsed in teaching labs and environmental research, the MC110 ensures controlled conditions and consistent monitoring for reliable experiment outcomes. It’s ideal for ongoing pH studies or student experiments requiring long-term monitoring.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eSwimming Pools \u0026amp; Spas\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eKeep your water crystal clear and safe for swimmers. The MC110 helps maintain pH balance, ensuring chlorine efficiency and preventing corrosion or discomfort caused by water that’s too acidic or too alkaline.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eWater Treatment \u0026amp; Purification\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether in municipal plants or home systems, stable pH is key to effective water treatment. The MC110 helps operators optimize chemical dosing and prevent corrosion in pipes and tanks.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eFood \u0026amp; Beverage Production\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIn fermentation and processing, pH influences taste, safety, and consistency. The MC110 is perfect for small wineries, breweries, or food processors who require continuous pH oversight without industrial-scale equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eProper Care \u0026amp; Maintenance\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eTo keep your MC110 performing at its best, routine maintenance is essential. Like all pH monitors, electrode lifespan and performance depend on proper care:\u003c\/p\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eAlways store the probe in MA9015 storage solution\u003c\/b\u003e – never in water.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eClean regularly\u003c\/b\u003e with MA9016 cleaning solution to prevent buildup and sensor drift.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate frequently\u003c\/b\u003e, especially after cleaning or long-term storage, using pH 7.01 and 4.01 buffer solutions.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eInspect the probe\u003c\/b\u003e for any signs of wear or contamination and replace it when response time slows.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eKeep the monitor in a stable, protected environment away from extreme temperatures and direct sunlight.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 class=\"MsoNormal\"\u003e \u003cb\u003eMILWAUKEE PRO PH PROBE CARE \u003c\/b\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003epH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eSENSING BULB \u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eREFERENCE JUNCTION \u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH pen will no longer function.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eYou can extend the life of your pH electrode in the following ways.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eSTORAGE \u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eStoring in pH probe storage solution or pH calibration buffers will help address both these issues.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not store in tap water and DI water. This will damage the sensitivity of the probe.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith proper maintenance, your MC110 will provide fast, reliable, and accurate pH monitoring for years to come.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eReady to Monitor Smarter?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eChoose the \u003cb\u003eMilwaukee MC110 PRO pH Monitor\u003c\/b\u003e for mid-range precision, long-term durability, and total peace of mind in pH control. Whether you’re growing, researching, or managing water systems – MC110 has your back.\u003c\/p\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"specification-tab-pane\" role=\"tabpanel\" aria-labelledby=\"specification-tab\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003epH Range: 0.0 - 14.0 pH\u003c\/div\u003e\n\u003cdiv\u003epH Resolution: 0.1 pH\u003c\/div\u003e\n\u003cdiv\u003epH Accuracy: ± 0.2 pH\u003c\/div\u003e\n\u003cdiv\u003eCalibration: Manual 2 points\u003c\/div\u003e\n\u003cdiv\u003eSetpoint range: 3.5 to 7.5 pH\u003c\/div\u003e\n\u003cdiv\u003eAlarm Active: when reading is higher or lower than set point\u003c\/div\u003e\n\u003cdiv\u003epH Electrode: MA911B\/2 (included)\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"application-tab-pane\" role=\"tabpanel\" aria-labelledby=\"application-tab\"\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eHydroponics \u0026amp; Horticulture\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn hydroponics and horticulture, pH balance directly affects nutrient availability. If the pH drifts too far from the optimal range (typically 5.5–6.5 for most plants), nutrients like nitrogen, phosphorus, and potassium become less accessible—no matter how well-formulated your nutrient mix is. The result? Slowed growth, nutrient deficiencies, and reduced yields.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC110 PRO pH Monitor\u003c\/b\u003e helps you avoid these issues by providing continuous, accurate monitoring of your nutrient solution’s pH. You’ll know the exact moment your pH begins to drift, allowing you to take fast corrective action. No more guessing, no more crop stress – just healthy, thriving plants with optimized root-zone conditions.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC110 in Hydroponics\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMount the Monitor\u003c\/b\u003e\u003cbr\u003eSecure the MC110 on a wall or stable surface near your nutrient reservoir or hydroponic tank using the included mounting bracket.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eInstall the Electrode\u003c\/b\u003e\u003cbr\u003ePlace the pH probe directly into your nutrient solution or tank, ensuring it's fully submerged and not resting on the bottom.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eConnect the Power Supply\u003c\/b\u003e\u003cbr\u003ePlug in the adapter to power the monitor. The digital display will activate immediately.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate the Monitor\u003c\/b\u003e\u003cbr\u003eUse Milwaukee’s pH 7.01 and pH 4.01 buffer solutions to perform a two-point manual calibration for optimal accuracy.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMonitor Continuously\u003c\/b\u003e\u003cbr\u003eOnce calibrated, the MC110 provides real-time pH readings. The built-in visual LED alarm will alert you if levels stray outside your desired range.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eAdjust Nutrient Solution as Needed\u003c\/b\u003e\u003cbr\u003eIf the pH goes off track, add pH up or pH down solutions accordingly to bring it back into range. The MC110 helps you respond faster, minimizing plant stress.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMaintain the Electrode\u003c\/b\u003e\u003cbr\u003eAfter use or every few weeks, clean the probe with MA9016 cleaning solution and store it in MA9015 storage solution to extend lifespan.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eAquariums \u0026amp; Aquaculture\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn both home aquariums and professional aquaculture, \u003cb\u003epH stability is crucial to aquatic health\u003c\/b\u003e. Even slight deviations can stress fish, disrupt biological filtration, and hinder coral or plant growth. In reef tanks, for instance, pH swings can harm sensitive invertebrates and corals, while in freshwater tanks or fish farms, poor pH control can increase disease risk and reduce breeding success.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the \u003cb\u003eMilwaukee MC110 PRO pH Monitor\u003c\/b\u003e, aquarists and fish farmers gain peace of mind through \u003cb\u003econtinuous, real-time pH tracking\u003c\/b\u003e. No more manual testing or worrying about overnight fluctuations – just accurate, around-the-clock monitoring to help you maintain ideal water chemistry and safeguard your aquatic life.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC110 in Aquariums \u0026amp; Fish Farms\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eChoose Your Mounting Spot\u003c\/b\u003e\u003cbr\u003eMount the MC110 monitor securely above or beside your tank or pond system. Ensure the display is easy to view at a glance.\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003ePosition the pH Electrode\u003c\/b\u003e\u003cbr\u003eSubmerge the electrode into the aquarium or aquaculture system, making sure it stays in a well-circulated area (away from filters or heaters that might skew readings).\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003ePower Up the Unit\u003c\/b\u003e\u003cbr\u003ePlug in the included power adapter. The digital display will turn on, ready to begin monitoring.\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate the Device\u003c\/b\u003e\u003cbr\u003eFor accurate performance, calibrate using Milwaukee's MA9004 (pH 4.01) and MA9007 (pH 7.01) buffer solutions before first use and periodically after that.\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eStart Monitoring pH Levels\u003c\/b\u003e\u003cbr\u003eWith the electrode in place, the MC110 will display live pH readings. The built-in LED alarm will alert you if levels drift outside your target range, so you can take immediate action.\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eAdjust pH as Needed\u003c\/b\u003e\u003cbr\u003eUse aquarium-safe pH up\/down solutions, buffers, or water changes to correct imbalances and restore stable conditions.\u003c\/li\u003e\n\u003cli style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCare for the Electrode\u003c\/b\u003e\u003cbr\u003eClean the probe regularly with MA9016 cleaning solution and store it in MA9015 storage solution when not in continuous use. Proper care ensures longer life and consistent accuracy.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eLaboratory \u0026amp; Education\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn laboratories and academic environments, \u003cb\u003eprecision and consistency are non-negotiable\u003c\/b\u003e. Whether you're conducting environmental research, chemistry experiments, or biology lab work, even small pH shifts can alter outcomes and compromise the integrity of data. For educational settings, students learning the scientific method need tools that are both \u003cb\u003ereliable and easy to use\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC110 PRO pH Monitor\u003c\/b\u003e is a trusted companion in both teaching labs and professional research spaces. It provides \u003cb\u003econtinuous, accurate pH readings\u003c\/b\u003e, allowing instructors, students, and researchers to focus on data interpretation instead of troubleshooting equipment. From monitoring aqueous solutions in environmental science to supporting chemistry demonstrations over multiple lab periods, the MC110 is built for long-term performance.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC110 in Labs \u0026amp; Classrooms\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l5 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSet Up the Monitor in a Safe Location\u003c\/b\u003e\u003cbr\u003eMount the MC110 on a stable lab bench or workstation where it’s easily visible and protected from splashes or movement.\u003c\/li\u003e\n\u003cli style=\"mso-list: l5 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eInstall the pH Electrode\u003c\/b\u003e\u003cbr\u003ePlace the electrode in a beaker, flask, or test container holding your solution. For classroom use, ensure students can observe the probe placement and read the display.\u003c\/li\u003e\n\u003cli style=\"mso-list: l5 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eConnect Power Supply\u003c\/b\u003e\u003cbr\u003ePlug in the AC adapter to power the monitor. The large, clear digital display makes it easy to track results during lectures or experiments.\u003c\/li\u003e\n\u003cli style=\"mso-list: l5 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003ePerform a Two-Point Calibration\u003c\/b\u003e\u003cbr\u003eUse Milwaukee's MA9004 (pH 4.01) and MA9007 (pH 7.01) buffer solutions to calibrate the monitor before each new experiment or lesson.\u003c\/li\u003e\n\u003cli style=\"mso-list: l5 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eBegin Monitoring\u003c\/b\u003e\u003cbr\u003eOnce calibrated, the monitor will continuously display the pH of the solution in real time—perfect for extended observation or reaction tracking.\u003c\/li\u003e\n\u003cli style=\"mso-list: l5 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eRecord \u0026amp; Analyze\u003c\/b\u003e\u003cbr\u003eStudents or researchers can log data at intervals or in real time, encouraging hands-on learning and accurate research documentation.\u003c\/li\u003e\n\u003cli style=\"mso-list: l5 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMaintain the Electrode for Accuracy\u003c\/b\u003e\u003cbr\u003eAfter use, clean the electrode with MA9016 cleaning solution and store it in MA9015 storage solution to preserve performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eSwimming Pools \u0026amp; Spas\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eMaintaining proper pH in pools and spas isn’t just about water clarity—it’s critical for \u003cb\u003eswimmer health\u003c\/b\u003e, \u003cb\u003eequipment protection\u003c\/b\u003e, and the \u003cb\u003eeffectiveness of sanitizing agents\u003c\/b\u003e like chlorine. A pH that’s too low (acidic) can cause \u003cb\u003eskin and eye irritation\u003c\/b\u003e, corrosion of ladders, pumps, and heaters, while a pH that’s too high (alkaline) can lead to \u003cb\u003escaling\u003c\/b\u003e, cloudy water, and reduced sanitizer performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMC110 PRO pH Monitor\u003c\/b\u003e by Milwaukee Instruments offers a dependable solution with \u003cb\u003econtinuous, accurate pH tracking\u003c\/b\u003e. This professional-grade monitor helps both residential and commercial users maintain ideal pH levels (typically between 7.2–7.6), ensuring optimal conditions for swimmers and extending the life of pool infrastructure.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're a facility manager, pool technician, or a homeowner who takes water care seriously, the MC110 empowers you to react quickly to fluctuations and make informed treatment decisions.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC110 in Pools \u0026amp; Spas\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l6 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMount the Monitor in a Dry, Visible Area\u003c\/b\u003e\u003cbr\u003eInstall the MC110 near the pool control center or water treatment area, ideally in a shaded and splash-protected spot for easy viewing.\u003c\/li\u003e\n\u003cli style=\"mso-list: l6 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003ePlace the Electrode in Circulating Water\u003c\/b\u003e\u003cbr\u003eSubmerge the pH electrode in a location where water is constantly moving, such as the return line or filtration outlet. This ensures accurate, representative readings of the pool’s overall pH.\u003c\/li\u003e\n\u003cli style=\"mso-list: l6 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eConnect to Power\u003c\/b\u003e\u003cbr\u003ePlug in the monitor using the included AC adapter. The digital display will begin showing live pH readings immediately.\u003c\/li\u003e\n\u003cli style=\"mso-list: l6 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate with Buffer Solutions\u003c\/b\u003e\u003cbr\u003ePerform a two-point calibration using Milwaukee buffer solutions (pH 4.01 and pH 7.01) to ensure accuracy. Calibration should be repeated regularly, especially before the swimming season starts.\u003c\/li\u003e\n\u003cli style=\"mso-list: l6 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMonitor Continuously\u003c\/b\u003e\u003cbr\u003eWith the MC110 installed and calibrated, you’ll get up-to-date pH readings throughout the day. This allows you to react quickly to changes caused by weather, bather load, or chemical additions.\u003c\/li\u003e\n\u003cli style=\"mso-list: l6 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eAdjust Treatment Accordingly\u003c\/b\u003e\u003cbr\u003eBased on readings, adjust your chemical dosing—like adding acid to lower pH or soda ash to raise it—while ensuring chlorine works at peak effectiveness.\u003c\/li\u003e\n\u003cli style=\"mso-list: l6 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eClean \u0026amp; Store the Electrode When Not in Use\u003c\/b\u003e\u003cbr\u003eIf the monitor will be inactive for an extended period (e.g., offseason), clean the electrode and store it in Milwaukee’s MA9015 storage solution to preserve its life.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eWater Treatment \u0026amp; Purification\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn both large-scale municipal facilities and compact home treatment systems, pH control is a \u003cb\u003ecritical step in the purification process\u003c\/b\u003e. Whether you're neutralizing acidic water, enhancing disinfection efficiency, or preventing scaling and corrosion, precise pH monitoring helps ensure \u003cb\u003ecompliance with safety standards\u003c\/b\u003e, \u003cb\u003eprotects infrastructure\u003c\/b\u003e, and \u003cb\u003eimproves overall water quality\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC110 PRO pH Monitor\u003c\/b\u003e is a professional, fixed-installation solution that provides \u003cb\u003econtinuous, high-accuracy pH readings\u003c\/b\u003e. It empowers water treatment operators, facility managers, and even advanced home users to keep pH within target ranges—typically between 6.5 and 8.5 depending on application—ensuring optimal dosing of chemicals like chlorine, lime, or acid neutralizers.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC110 in Water Treatment \u0026amp; Purification\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l3 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSecure the Unit in a Stable Location\u003c\/b\u003e\u003cbr\u003eMount the MC110 on a clean, dry surface near your water treatment panel or chemical injection system. Ensure it’s easily visible for regular checks.\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSubmerge or Install the pH Electrode in a Sample Line\u003c\/b\u003e\u003cbr\u003ePlace the electrode in a pipe loop, sampling tank, or inline cell where it receives a consistent flow of water. This provides real-time data representative of the system's overall water chemistry.\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003ePower and Calibrate the Monitor\u003c\/b\u003e\u003cbr\u003ePlug in the unit and calibrate it using certified buffer solutions (pH 7.01 and pH 4.01). Accurate calibration is crucial for precise pH control in treatment systems.\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMonitor pH Continuously\u003c\/b\u003e\u003cbr\u003eUse the digital display to track pH fluctuations in real-time. If the system veers out of range, the MC110 allows you to act before water quality is compromised.\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eFine-Tune Chemical Dosing\u003c\/b\u003e\u003cbr\u003eAdjust dosing pumps or chemical feeders based on the monitor’s readings. For example, if pH is too low, increase alkaline dosing (like soda ash); if too high, use acid feed to bring it down.\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMaintain the Electrode Regularly\u003c\/b\u003e\u003cbr\u003eClean the probe to remove scale or biofilm and recalibrate as needed—especially after major chemical adjustments. Store the probe in MA9015 storage solution if it’s not in continuous use.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eFood \u0026amp; Beverage Production\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn the food and beverage industry, pH is not just a measurement—it's a \u003cb\u003ecritical factor in flavor development, microbial safety, texture, and shelf life\u003c\/b\u003e. From wine fermentation to cheese aging or sauce production, maintaining a stable pH is key to producing a \u003cb\u003econsistent and high-quality product\u003c\/b\u003e every time.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC110 PRO pH Monitor\u003c\/b\u003e offers a \u003cb\u003eprofessional-grade, continuously operating pH monitoring solution\u003c\/b\u003e ideal for small wineries, microbreweries, kombucha makers, and artisanal food processors. It bridges the gap between handheld testers and costly industrial automation, delivering \u003cb\u003ereal-time monitoring\u003c\/b\u003e without overcomplicating your process.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBy having a reliable pH readout visible at all times, producers can confidently manage processes like:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMalolactic fermentation in wine\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMash conversions in brewing\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAcidification in sauces, yogurts, and preserves\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eEnsuring pH-critical HACCP compliance in processing plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC110 in Food \u0026amp; Beverage Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eInstall the Monitor Near Your Processing Station\u003c\/b\u003e\u003cbr\u003eMount the MC110 in a clean, splash-protected area within reach of your production line, fermentation tanks, or pH-critical mixing zones.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003ePlace the pH Probe in a Sampling Point or Tank\u003c\/b\u003e\u003cbr\u003eThe probe can be immersed in a sample jar, installed in a sample loop, or placed directly into small tanks during fermentation. Use a secure holder to keep the probe in place.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate with Food-Grade Buffer Solutions\u003c\/b\u003e\u003cbr\u003eBefore each production cycle, calibrate using certified pH 7.01 and 4.01 buffer solutions. Regular calibration ensures precise readings essential for food safety.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eMonitor Continuously During Production\u003c\/b\u003e\u003cbr\u003eKeep an eye on the display throughout the batch or fermentation process. This allows you to make quick adjustments to ingredients, temperature, or time based on real-time pH changes.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eAdjust Ingredients Based on Readings\u003c\/b\u003e\u003cbr\u003eUse pH readings to guide the addition of acids (e.g., citric or tartaric acid) or bases (e.g., calcium carbonate). In fermentation, you may also use pH to determine phase transitions or end points.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eClean and Store the Probe Correctly\u003c\/b\u003e\u003cbr\u003eAfter use, rinse the probe with distilled water and clean it using MA9016 cleaning solution to remove residues. Store in MA9015 storage solution to maintain sensor health.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56106781507957,"sku":"MC110","price":138.06,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/MC110_incl-EURO_1920x1920_146c5c92-3c6f-443b-a2ca-c404edbda888.jpg?v=1760610342"},{"product_id":"milwaukee-mc510-pro-digital-redox-orp-controller","title":"Milwaukee MC510 PRO Digital Redox ORP Controller","description":"\u003cdiv\u003eThe Milwaukee PRO digital Redox ORP controller automatically monitors and fine-tunes ORP levels. Just set your ORP parameters and let the Milwaukee ORP Controller do the rest.\u003c\/div\u003e\n\u003cdiv\u003eThe Milwaukee PRO digital ORP controller is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are aquariums, swimming pools and spas, and other water quality monitoring uses.\u003c\/div\u003e\n\u003cdiv\u003eThe Milwaukee PRO ORP controller offers:\u003c\/div\u003e\n\u003ch4\u003eACCURACY\u003c\/h4\u003e\n\u003cdiv\u003eThe Milwaukee PRO ORP controller is accurate ±5 mV.\u003c\/div\u003e\n\u003ch4\u003eAUTOMATION\u003c\/h4\u003e\n\u003cdiv\u003eThe controller provides a control range of ±1000 mV with a user selectable set point with a range of 0 - 600 mV and a visual \"Power Activated\" LED light.\u003c\/div\u003e\n\u003ch4\u003eCOMPATIBLE DOSING PUMP\u003c\/h4\u003e\n\u003cdiv\u003eMilwaukee includes a 12 VDC power plug socket compatible with Ozone Dosing units.\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eDESIGN FEATURES\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eFast easy to read current results with large digital LCD readout\u003c\/li\u003e\n\u003cli\u003eAccurate to ±5 mV with the user selectable high\/low set points\u003c\/li\u003e\n\u003cli\u003eGel-filled, double junction lab grade Platinum ORP electrode for low maintenance and high performance included\u003c\/li\u003e\n\u003cli\u003e6.5 feet probe cables for extra flexibility when testing\u003c\/li\u003e\n\u003cli\u003e12 VDC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eCARE AND USE\u003c\/h2\u003e\n\u003cdiv\u003eProperly maintaining your ORP probe will give your fast, accurate results for longer.\u003c\/div\u003e\n\u003cdiv\u003eHere are our top three tips.\u003c\/div\u003e\n\u003cdiv\u003e1. Always store with the cap full of buffer or storage solution not water.\u003c\/div\u003e\n\u003cdiv\u003e2. Clean your probe regularly by soaking in cleaning solution.\u003c\/div\u003e\n\u003cdiv\u003e3. After cleaning return the ORP probe sensor to the tank.\u003c\/div\u003e\n\u003cdiv\u003eThank you for considering Milwaukee to help you take your results to the next level.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003eRange: ±1000 mV\u003cbr\u003eResolution: 1 mV\u003cbr\u003eAccuracy: ±5 mV\u003cbr\u003eCalibration: Factory checked\u003cbr\u003eSet Point Range: 0 - 600 mV with alarm active when reading is higher or lower than set point\u003cbr\u003eDosing Contact: 1 power plug for O3 dosing\u003cbr\u003eElectrode: Double Junction MA921B\/2 Probe (included)\u003cbr\u003eEnvironment: 0 - 50°C | 32 to 122°F; max RH 95%\u003cbr\u003ePower Supply: 12 VDC adapter (included)\u003cbr\u003ePower Drivers: 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz\u003cbr\u003eDimensions: 5.8 x 3.2 x 1.3 inches\u003cbr\u003eWeight: 6.3 ounces (meter only)\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56134168478069,"sku":"MC510","price":222.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/MC510copy_1920x1920_dc1d6d97-d8ee-49dd-9f84-596443f60337.jpg?v=1761038704"},{"product_id":"milwaukee-mc125-pro-2-in-1-digital-ph-orp-controller","title":"Milwaukee MC125 PRO 2-in-1 Digital pH \/ ORP Controller","description":"\u003cdiv class=\"offcanvas-content-container\"\u003e\n\u003cdiv class=\"product-detail-description tab-pane-container\"\u003e\n\u003cdiv class=\"product-detail-description-text\" itemprop=\"description\"\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003eMilwaukee MC125 PRO 2-in-1 Digital pH \/ ORP Controller – Automated pH Monitoring \u0026amp; Control for Aquariums, Hydroponics and more\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eTake your pH management to the next level with the Milwaukee MC125 pH Controller. Whether you're managing a hydroponic system, maintaining an aquarium, working in a laboratory, or overseeing industrial processes, the MC125 is designed to provide continuous, real-time pH monitoring and on\/off control. With its precision, durability, and easy-to-use features, it ensures that pH levels are always within the desired range – automatically.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eEquipped with a high-quality pH electrode and intuitive controls, the MC125 helps you monitor and adjust your pH environment without manual intervention. From aquariums to water treatment systems, the MC125 ensures accurate pH regulation, offering peace of mind to professionals and hobbyists alike.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Milwaukee MC125 pH Controller is the go-to solution for anyone who needs reliable, automated pH management. Whether you're in agriculture, aquaculture, water treatment, or manufacturing, this controller takes the guesswork out of pH regulation, providing peace of mind and improving efficiency. Its easy-to-use design, combined with precision control and automation capabilities, makes the MC125 a trusted tool for professionals across many industries.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eWhy Choose the Milwaukee MC125?\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eContinuous pH Monitoring\u003c\/b\u003e – Always keep track of your pH levels with real-time readings.\u003cbr\u003e• \u003cb\u003ePrecise Control\u003c\/b\u003e – Set the ideal pH range with adjustable setpoints.\u003cbr\u003e• \u003cb\u003eBuilt-in Alarm LED\u003c\/b\u003e – Visual alerts when pH exceeds the set range.\u003cbr\u003e• \u003cb\u003eCompact \u0026amp; Easy to Install\u003c\/b\u003e – Durable, wall-mountable design for any space.\u003cbr\u003e• \u003cb\u003eIncludes pH Electrode\u003c\/b\u003e – Ready to use out of the box.\u003cbr\u003e• \u003cb\u003eVersatile Compatibility\u003c\/b\u003e – BNC connection works with a variety of pH probes.\u003cbr\u003e• \u003cb\u003eIdeal for Automation\u003c\/b\u003e – Integrate with dosing pumps, CO₂ systems, or other pH-adjusting devices.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eProper Care \u0026amp; Maintenance\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eTo ensure the longevity and accuracy of your \u003cb\u003eMC125\u003c\/b\u003e pH Controller:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l8 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAlways keep the pH probe in storage solution (not water) when not in use.\u003c\/li\u003e\n\u003cli style=\"mso-list: l8 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eClean the probe regularly using a cleaning solution (such as \u003cb\u003eMA9016\u003c\/b\u003e).\u003c\/li\u003e\n\u003cli style=\"mso-list: l8 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCalibrate the system frequently using pH buffer solutions (like \u003cb\u003eMA9004\u003c\/b\u003e and \u003cb\u003eMA9007\u003c\/b\u003e) to maintain precision.\u003c\/li\u003e\n\u003cli style=\"mso-list: l8 level1 lfo12; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eReplace the probe as needed to ensure consistent and accurate pH readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWe recommend adding the \u003cb\u003eMilwaukee pH Maintenance Kit (PH-Main)\u003c\/b\u003e to your order for comprehensive support with cleaning, calibration, and storage from day one.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eAutomate with Confidence. Trust Milwaukee.\u003c\/b\u003e\u003cbr\u003eWhether you're growing, brewing, treating water, or working in industrial processes – the \u003cb\u003eMilwaukee MC125\u003c\/b\u003e is your trusted partner for precise pH control. Designed to simplify your process and provide reliable results, it combines performance and peace of mind for your daily operations.\u003c\/p\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"specification-tab-pane\" role=\"tabpanel\" aria-labelledby=\"specification-tab\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003epH Range: 0.00 - 14.00 pH\u003c\/div\u003e\n\u003cdiv\u003eORP Range: ± 1000mV\u003c\/div\u003e\n\u003cdiv\u003epH Resolution: 0.01 pH\u003c\/div\u003e\n\u003cdiv\u003eORP Resolution: ± 1 mV\u003c\/div\u003e\n\u003cdiv\u003epH Accuracy: ± 0.2 pH\u003c\/div\u003e\n\u003cdiv\u003eORP Accuracy: ± 5 mV\u003c\/div\u003e\n\u003cdiv\u003eSet point pH: 4 to 8 pH\u003c\/div\u003e\n\u003cdiv\u003eSet point ORP: -200 to 600 mV\u003c\/div\u003e\n\u003cdiv\u003eCalibration: Manual 2 points pH\u003c\/div\u003e\n\u003cdiv\u003eAlarm Active when reading is higher or lower than set point\u003c\/div\u003e\n\u003cdiv\u003epH Dosing Contact\u003c\/div\u003e\n\u003cdiv\u003e1 power plug for CO2 dosing\u003c\/div\u003e\n\u003cdiv\u003eORP Dosing Contact\u003c\/div\u003e\n\u003cdiv\u003e1 power plug for O3 dosing\u003c\/div\u003e\n\u003cdiv\u003epH Electrode: MA911B\/2 (included)\u003c\/div\u003e\n\u003cdiv\u003eORP Electrode: MA921B\/2 (included)\u003c\/div\u003e\n\u003cdiv\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/div\u003e\n\u003cdiv\u003ePower Supply: 12 VDC adapter (included)\u003c\/div\u003e\n\u003cdiv\u003ePower Drivers: 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz\u003c\/div\u003e\n\u003cdiv\u003eDimensions: 5.8 x 3.25 x 1.26 inches\u003c\/div\u003e\n\u003cdiv\u003eWeight: 7.1 ounces\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHydroponics \u0026amp; Horticulture\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIn hydroponic systems and horticultural environments, maintaining the correct pH balance of the nutrient solution is critical for optimal plant health. The pH level influences the solubility and availability of essential nutrients, and a slight deviation from the ideal range can result in nutrient deficiencies, poor growth, or even plant death. The \u003cb\u003eMilwaukee MC125 pH Controller\u003c\/b\u003e ensures that your plants receive the perfect pH environment, supporting healthy growth and maximizing yield potential.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC125 pH Controller\u003c\/b\u003e is perfect for:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHydroponic vegetable growers\u003c\/b\u003e: Provides precise pH control for leafy greens, tomatoes, cucumbers, and other hydroponic crops.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHome growing \u003c\/b\u003e: Ensures the pH is perfectly suited for plants that require specific pH ranges for optimal growth, promoting healthy development and maximizing yield.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOrnamental plant production\u003c\/b\u003e: Whether you’re growing flowers or other ornamental plants, the MC125 helps you maintain the best growing conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBenefits:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eReduced Labor\u003c\/b\u003e: The MC125 eliminates the need for manual pH testing and adjustments, saving you time and effort.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eImproved Plant Health\u003c\/b\u003e: Consistent pH levels ensure that your plants receive the correct nutrients, leading to healthier, stronger plants.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIncreased Yields\u003c\/b\u003e: By optimizing the pH levels, you can increase the effectiveness of your nutrient solution, resulting in better yields and higher-quality produce.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow It Works:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC125 pH Controller\u003c\/b\u003e is a state-of-the-art, reliable tool designed to monitor and adjust the pH level of your nutrient solution. Here’s how it functions:\u003c\/p\u003e\n\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l10 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSet Desired pH Range:\u003c\/b\u003e Begin by selecting the pH range that is optimal for your plants (typically between 5.5-6.5 for hydroponics and horticulture). This range can vary depending on the type of plants being cultivated. For example, cannabis typically thrives in a pH range of 5.8–6.2, while vegetables may require a slightly higher range.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l10 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eAutomatic pH Adjustment:\u003c\/b\u003e The \u003cb\u003eMC125\u003c\/b\u003e continuously monitors the pH level of your nutrient solution. If the pH falls outside the desired range, the controller activates your dosing pump (sold separately), adding pH-adjusting solutions automatically. This ensures that the pH is always within the optimal range for nutrient absorption.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l10 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003ePrecision Monitoring:\u003c\/b\u003e The controller uses a high-precision pH probe that provides real-time readings. You can rely on the \u003cb\u003eMC125\u003c\/b\u003e to continuously check the pH without the need for manual testing, reducing the risk of human error.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l10 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eUser-Friendly Interface:\u003c\/b\u003e The controller’s simple and intuitive interface makes it easy to set up and adjust the pH parameters. With easy-to-read digital displays, you can easily see the current pH level and make any necessary adjustments to suit your system’s needs.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use:\u003c\/b\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eInstall the pH Probe: \u003c\/b\u003ePlace the included pH probe into your nutrient solution. Make sure it’s properly connected to the MC125 controller.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSet Your Desired pH Range:\u003c\/b\u003e Use the controller’s interface to set the target pH range for your system. For example, if you're growing hydroponic tomatoes, set the pH range between 5.8 and 6.2. The controller will then aim to keep the pH within this window.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eConnect the Dosing Pump:\u003c\/b\u003e Attach a compatible dosing pump to the \u003cb\u003eMC125\u003c\/b\u003e. This pump will be activated whenever the pH falls outside the set range. Ensure that the pump is connected to a container of pH-adjusting solution, such as phosphoric acid or potassium hydroxide, depending on whether the pH is too high or too low.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eMonitor and Adjust:\u003c\/b\u003e The \u003cb\u003eMC125\u003c\/b\u003e will continuously monitor the pH and make automatic adjustments as necessary. If the pH drifts too high or too low, the dosing pump will be activated to add the required pH solution. It’s important to check that the dosing pump is working properly and that you have sufficient pH solution available in the reservoir.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eRegular Calibration:\u003c\/b\u003e To maintain accuracy, it’s important to regularly calibrate the pH probe. Calibration ensures that the readings are precise and reliable over time. You can easily calibrate the probe using standard pH calibration solutions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eAquariums \u0026amp; Aquaculture\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIn both freshwater and marine environments, pH is a critical factor for maintaining a healthy ecosystem. Aquatic life, including fish, plants, and corals, all thrive within specific pH ranges. The MC125 pH Controller helps maintain a stable and optimal pH level, supporting the overall well-being of your aquatic environment. By automating the pH regulation process, it takes the guesswork out of water quality management, ensuring your system remains in balance without the need for constant manual testing.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIdeal for:\u003c\/b\u003e The MC125 is perfect for a variety of applications, including home aquariums, reef tanks, fish farms, and larger aquaculture systems. It’s designed to handle the delicate balance of maintaining ideal pH conditions for diverse aquatic species, from tropical fish to coral reefs and other marine life.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the MC125, you can rest assured that your aquatic environment is being managed with precision, allowing you to focus on enjoying and cultivating a thriving ecosystem.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow It Works:\u003c\/b\u003e The MC125 continuously monitors the pH levels of the water and automatically adjusts them as needed. When the pH falls outside the set range, the controller activates connected systems like CO₂ regulators or dosing pumps (sold separately), adding the necessary substances to bring the pH back into the desired range. This automatic action ensures that your aquatic life is consistently exposed to the ideal water conditions, minimizing stress and promoting healthy growth.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use:\u003c\/b\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSet Your pH Range:\u003c\/b\u003e Start by setting the desired pH range for your specific aquatic setup (e.g., freshwater tank, marine tank, or aquaculture system).\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eConnect the Dosing Systems:\u003c\/b\u003e Attach dosing pumps or CO₂ regulators to the controller to automatically adjust the pH levels when needed.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eContinuous Monitoring:\u003c\/b\u003e The MC125 will continuously monitor the pH, ensuring it stays within the optimal range. If any adjustments are required, the controller will automatically activate the connected systems, saving you time and effort in managing the water conditions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eWater Treatment \u0026amp; Purification\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIn water treatment processes, maintaining the correct pH is crucial for ensuring the effectiveness of various chemical reactions, such as disinfection, coagulation, and metal precipitation. pH levels that are too high or too low can hinder these processes, reducing the overall effectiveness of water treatment. The MC125 pH Controller provides a reliable, automated solution for small-scale water treatment systems, maintaining pH levels within the optimal range for efficient chemical reactions and compliance with water quality standards.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIdeal for:\u003c\/b\u003e The MC125 is designed for use in small-scale water treatment systems, including municipal water treatment plants, industrial water treatment setups, and laboratory environments. Whether you are managing the water quality in a municipal system or conducting experiments in a lab, the MC125 ensures that your pH control is automated and reliable, minimizing the need for constant manual adjustments.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBy using the MC125, you can streamline your water treatment processes, reduce the risk of pH-related inefficiencies, and improve both water quality and regulatory compliance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow It Works:\u003c\/b\u003e The MC125 continuously monitors the pH of the water and keeps it within the designated range by controlling connected acid\/base dosing systems (sold separately). When the pH drifts outside the set parameters, the controller activates the dosing pumps to introduce the necessary chemicals to correct the pH. This process helps to ensure that the water treatment reactions, such as disinfection and precipitation, proceed effectively, improving water quality and ensuring compliance with regulatory standards.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use:\u003c\/b\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSet Desired pH Range:\u003c\/b\u003e Determine the ideal pH range for your specific water treatment process, taking into account the chemical reactions involved.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eConnect Dosing Systems:\u003c\/b\u003e Link the MC125 to the appropriate acid\/base dosing systems to adjust the pH when necessary.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eContinuous pH Monitoring:\u003c\/b\u003e The MC125 will continuously monitor the pH levels of the water. When adjustments are needed, it will activate the dosing systems, ensuring that the pH remains within the optimal range.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eLaboratories \u0026amp; Educational Use\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIn both research laboratories and educational settings, precise pH control is vital for the success of experiments that rely on stable chemical, biochemical, or biological reactions. Even small fluctuations in pH can significantly affect the outcome of sensitive experiments, leading to inaccurate results or compromised findings. The MC125 pH Controller is designed to take the guesswork out of pH management, ensuring that your experiments remain consistent and reliable. This allows researchers, educators, and students to focus on the science rather than constantly monitoring and adjusting pH levels.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIdeal for:\u003c\/b\u003e The MC125 is ideal for use in a variety of laboratory and educational settings. It is perfect for \u003cb\u003eresearch labs\u003c\/b\u003e where precision is critical for successful experiments and \u003cb\u003eeducational institutions\u003c\/b\u003e where students can benefit from hands-on learning with automated, accurate pH control. It is also useful for \u003cb\u003escientific demonstrations\u003c\/b\u003e where pH management is a key component of the experiment, ensuring that everything runs smoothly and without interruption.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBy incorporating the MC125 into your lab or classroom, you can enhance the accuracy and reliability of your experiments, reduce the need for manual interventions, and provide a more efficient and productive learning or research environment. Whether it's ensuring the stability of a biochemical reaction or demonstrating the importance of pH in various scientific processes, the MC125 is a trusted tool for seamless pH control in the lab.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow It Works:\u003c\/b\u003e The MC125 integrates seamlessly into any laboratory or classroom setup. It continuously monitors the pH levels of solutions and automatically adjusts them using connected dosing systems (sold separately) to maintain the desired range. Whether conducting biochemical reactions, enzyme activity studies, or chemical synthesis, the MC125 ensures that the pH stays within the optimal parameters, eliminating the need for frequent manual pH checks. This automated control helps maintain the stability of experimental conditions, leading to more accurate and reproducible results.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use:\u003c\/b\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo5; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSet the pH Range:\u003c\/b\u003e Define the ideal pH range for your experiment or educational demonstration, considering the requirements of the chemical or biological process being studied.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo5; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eConnect Dosing Systems:\u003c\/b\u003e Link the MC125 to appropriate dosing systems for both acid and base solutions. These systems will automatically adjust the pH when necessary.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo5; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eContinuous pH Monitoring:\u003c\/b\u003e The MC125 will provide real-time pH monitoring and adjust the levels as needed to keep the experiment within the optimal range.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo5; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eEffortless Adjustment:\u003c\/b\u003e Once set, the system operates autonomously, allowing researchers or educators to focus on other aspects of their work while the MC125 handles pH management.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHomebrewing \u0026amp; Fermentation\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIn the world of brewing and fermentation, pH plays a pivotal role in the final product’s taste, safety, and quality. Whether you are crafting beer, wine, cider, or kombucha, maintaining the right pH levels throughout the brewing or fermentation process can be the difference between a successful batch and one that’s less than ideal. The \u003cb\u003eMC125 pH Controller\u003c\/b\u003e offers automated pH control, removing the guesswork and manual adjustments that can take time and attention away from perfecting your craft. With the MC125, you can ensure precise pH levels are maintained from the start of fermentation to the end, leading to better tasting and more consistent results in your brewed products.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIdeal for:\u003c\/b\u003e The \u003cb\u003eMC125\u003c\/b\u003e is a game-changer for \u003cb\u003ehomebrewers\u003c\/b\u003e, helping them achieve professional-grade pH control without needing a chemistry lab. It’s also perfect for \u003cb\u003esmall-batch breweries\u003c\/b\u003e looking to enhance the consistency and quality of their products. For \u003cb\u003efermenters\u003c\/b\u003e working with kombucha, cider, or wine, the MC125 ensures that each batch undergoes fermentation under the ideal conditions for taste and quality.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis automated pH control device is designed for those who are serious about their craft and want to ensure every batch is just right. From \u003cb\u003ehomebrew enthusiasts\u003c\/b\u003e to professionals in the \u003cb\u003emicrobrewery\u003c\/b\u003e or \u003cb\u003efermentation industry\u003c\/b\u003e, the MC125 helps you streamline the process and achieve consistently great results.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBy integrating the MC125 into your brewing or fermentation setup, you’ll eliminate the stress of constantly adjusting pH manually, allowing you to focus on what truly matters—crafting the perfect beverage. Whether you're brewing a crisp IPA, a rich stout, or fermenting a tangy batch of kombucha, the MC125 ensures that pH levels stay in check for better flavors, higher quality, and a more successful fermentation process.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003cb\u003eHow It Works:\u003c\/b\u003e The MC125 is designed to automate the pH management in your brewing or fermentation process. It continuously monitors the pH level and, if necessary, adjusts it using dosing pumps that add pH-adjusting solutions, ensuring the pH stays within the desired range. This level of control is perfect for fine-tuning the mash pH during the brewing process or ensuring the proper acidity for fermented beverages like beer, wine, or kombucha. Whether you’re brewing at home or managing a small-scale operation, the MC125 simplifies the process by maintaining pH balance with minimal intervention.\u003c\/p\u003e\n\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l9 level1 lfo6; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSet the Desired pH Range:\u003c\/b\u003e Establish the optimal pH levels for each phase of your brewing or fermentation process. For example, different stages may require varying pH ranges to achieve the best flavor or fermentation efficiency.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l9 level1 lfo6; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eLink to Dosing Pumps:\u003c\/b\u003e Connect the MC125 to your dosing pumps, which will add acid or base solutions when pH strays outside the set range. These dosing pumps are crucial for making precise adjustments, whether it’s lowering the pH during mash time or raising it for fermentation stabilization.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l9 level1 lfo6; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eContinuous Monitoring:\u003c\/b\u003e The MC125 will constantly monitor your brew or fermentation vessel, ensuring that the pH remains stable and within the ideal range for the process. This can help prevent issues like off-flavors caused by improper pH or stuck fermentation caused by unbalanced acidity.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l9 level1 lfo6; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eEffortless Automation:\u003c\/b\u003e Once set up, the MC125 provides a hands-off solution, allowing you to focus on refining your recipes and techniques while it maintains the perfect pH balance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use:\u003c\/b\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo9; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eInstall the pH Controller:\u003c\/b\u003e Place the \u003cb\u003eMC125 pH Controller\u003c\/b\u003e in a convenient location near your brewing setup. Connect it to the pH probe and the dosing pump (sold separately) that will add pH-adjusting solutions to your brew.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo9; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSet the Desired pH Range:\u003c\/b\u003e Input your target pH range on the MC125 controller. For most brewing applications, the ideal pH for the mash typically falls between \u003cb\u003e5.2 and 5.6\u003c\/b\u003e, depending on the grain bill and recipe. Adjust the range to suit your specific brewing process or fermentation style.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo9; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eConnect the Dosing Pump:\u003c\/b\u003e Connect the MC125 to a dosing pump. The pump will be used to automatically add pH-lowering chemicals (such as phosphoric acid or lactic acid) to your mash or wort when the pH exceeds the set limit. This ensures consistent and accurate pH control during the brewing process.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo9; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eMonitor the pH During Brewing:\u003c\/b\u003e Once everything is set up, the MC125 will continuously monitor the pH throughout your brewing process. When the pH moves outside the desired range, the controller will activate the dosing pump to bring the pH back within the target range. This happens automatically without the need for manual adjustments.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo9; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eFine-tune the pH for Fermentation:\u003c\/b\u003e The MC125 not only helps with the mash pH but can also be used during fermentation, especially for controlling the acidity of fermented beverages like beer, wine, or kombucha. As fermentation progresses, pH can fluctuate, and the MC125 will keep it stable, promoting the best flavor and fermentation conditions.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo9; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eEnjoy Consistent Results:\u003c\/b\u003e With the MC125 in place, you’ll enjoy precise, consistent pH control throughout your brewing process, ensuring that your final product is as intended, with optimal flavors and consistency in each batch.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003eThis will ensure that your homebrewing process is more precise and automated, leaving you more time to perfect your recipes while the MC125 handles the pH control!\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e  \u003cbr\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003ePools \u0026amp; Spas\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eMaintaining the right pH in your pool or spa is essential for several reasons. Not only does it ensure \u003cb\u003eswimmer comfort\u003c\/b\u003e by preventing skin irritation and eye discomfort, but it also protects your \u003cb\u003eequipment\u003c\/b\u003e from corrosion or scaling, prolonging its lifespan. Additionally, maintaining optimal pH is key to the effectiveness of \u003cb\u003esanitizers\u003c\/b\u003e, ensuring that your pool or spa water remains safe, clean, and inviting. The \u003cb\u003eMC125 pH Controller\u003c\/b\u003e helps you achieve and maintain this balance effortlessly, providing peace of mind and saving you time on manual pH testing and adjustments. By automating the pH regulation process, the MC125 ensures that your water stays within the ideal range for both safety and comfort.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIdeal for:\u003c\/b\u003e The \u003cb\u003eMC125\u003c\/b\u003e is an excellent solution for residential \u003cb\u003epools\u003c\/b\u003e, \u003cb\u003ehot tubs\u003c\/b\u003e, and \u003cb\u003espas\u003c\/b\u003e where constant pH monitoring and adjustments are needed. It's also well-suited for \u003cb\u003ehotel facilities\u003c\/b\u003e, \u003cb\u003epublic pools\u003c\/b\u003e, or \u003cb\u003ewellness centers\u003c\/b\u003e, where the volume of guests can lead to significant variations in water quality.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis pH controller ensures that your pool or spa water remains crystal clear, safe, and comfortable for swimmers by automating the pH management process. By maintaining the perfect pH, you will not only enhance the user experience but also safeguard your equipment and reduce the need for costly repairs or chemical overuse.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the \u003cb\u003eMC125 pH Controller\u003c\/b\u003e, maintaining the right pH becomes a hassle-free task, ensuring that your pool or spa stays comfortable, safe, and well-maintained year-round.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow It Works:\u003c\/b\u003e The \u003cb\u003eMC125\u003c\/b\u003e continuously monitors the pH levels in your pool or spa and integrates seamlessly with a dosing pump (sold separately) to automatically add pH-lowering chemicals when necessary. By constantly tracking the water’s pH, the MC125 ensures that it stays within the optimal range, typically between 7.2 and 7.8, which is ideal for both swimmer comfort and sanitizer effectiveness.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eHere’s how the process works:\u003c\/p\u003e\n\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo7; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSet the Desired pH Range:\u003c\/b\u003e Define the ideal pH level for your pool or spa. The MC125 allows you to easily customize the range, making it ideal for pools, spas, or hot tubs that require specific pH parameters for optimal performance.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo7; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eConnect to a Dosing Pump:\u003c\/b\u003e The MC125 links to a dosing pump, which will add pH-lowering chemicals (such as muriatic acid or sodium bisulfate) automatically when the pH goes above your set threshold. This helps to prevent problems caused by high pH, such as scaling on pool surfaces, cloudy water, or reduced sanitizer effectiveness.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo7; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eContinuous Monitoring and Adjustment:\u003c\/b\u003e The MC125 consistently monitors the pH, ensuring that any fluctuations are quickly addressed, keeping the water balanced without the need for manual intervention. This is especially useful for high-traffic pools or spas where pH can change more rapidly due to factors like temperature fluctuations, bather load, or rainfall.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo7; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eEffortless Maintenance:\u003c\/b\u003e Once set up, the MC125 provides automated, real-time adjustments, removing the hassle of frequent manual testing and chemical dosing. This gives pool or spa owners more time to enjoy their facilities without worrying about the technicalities of water chemistry.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use:\u003c\/b\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo8; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eInstall the pH Controller:\u003c\/b\u003e Place the MC125 in a suitable location near your pool or spa system and connect it to the pH probe and dosing pump.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo8; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSet the Desired pH Range:\u003c\/b\u003e Using the easy-to-navigate interface, input your desired pH range (typically between 7.2 and 7.8). The MC125 will monitor the pH in real-time and make adjustments automatically.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo8; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eConnect the Dosing Pump:\u003c\/b\u003e Connect the MC125 to the dosing pump, which will automatically add pH-lowering chemicals when the pH level rises beyond the set range. The controller will activate the pump only when necessary, ensuring chemical efficiency and cost savings.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo8; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eMonitor and Adjust Settings:\u003c\/b\u003e After setup, the MC125 will manage the pH levels continuously. However, you can adjust settings at any time to suit your needs, whether for seasonal changes or different bather loads.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo8; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eEnjoy Effortless Maintenance:\u003c\/b\u003e Once the system is set up, you can focus on enjoying your pool or spa without worrying about pH levels or water balance. The MC125 will handle all the hard work, ensuring that your water remains in perfect condition.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eIndustrial Processes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIndustrial processes often require precise pH control to ensure the quality of products, maintain safety standards, and meet regulatory requirements. The \u003cb\u003eMC125 pH Controller\u003c\/b\u003e offers a reliable and cost-effective solution for industries seeking to automate pH management, reduce manual intervention, and enhance operational efficiency.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAccurate pH levels are critical in various industrial processes, such as electroplating, chemical manufacturing, textile finishing, and industrial cooling. A slight deviation from the ideal pH range can impact product consistency, compromise process efficiency, and lead to costly waste. The \u003cb\u003eMC125\u003c\/b\u003e simplifies these challenges by automating pH regulation, reducing the risk of human error, and ensuring optimal conditions for every step of the process.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMC125\u003c\/b\u003e provides automated control, ensuring that pH levels remain stable and fall within the desired range for your production system. By adjusting the pH using a dosing pump (sold separately), the controller ensures that acids or bases are added when necessary, optimizing chemical reactions and product quality.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIdeal for:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eElectroplating\u003c\/b\u003e: Maintains the necessary pH for metal coatings, preventing inconsistent finishes and improving coating adhesion.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eChemical Manufacturing\u003c\/b\u003e: Supports the proper pH balance for chemical reactions, enhancing product quality and minimizing chemical waste.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eTextile Finishing\u003c\/b\u003e: Ensures consistent pH levels during dyeing and fabric treatments, improving color uniformity and fabric quality.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIndustrial Cooling Systems\u003c\/b\u003e: Regulates the pH of water used in cooling towers, preventing scale buildup and corrosion in heat exchangers.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow It Works:\u003c\/b\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eContinuous Monitoring:\u003c\/b\u003e The \u003cb\u003eMC125\u003c\/b\u003e continuously monitors the pH of your system, whether it's a chemical bath, wastewater, or cooling system. The pH probe continuously sends readings to the controller.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eAutomated pH Adjustment:\u003c\/b\u003e When pH levels shift beyond the preset limits, the \u003cb\u003eMC125\u003c\/b\u003e activates the connected dosing pump to inject the appropriate pH-adjusting solution (acid or base). This ensures that the pH returns to the ideal range without the need for manual intervention.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eCustomized Control:\u003c\/b\u003e The system is fully customizable, allowing you to set precise pH thresholds tailored to your specific industrial process. This flexibility is especially useful when dealing with multiple production stages or varying chemical reactions.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eReduced Maintenance and Waste:\u003c\/b\u003e With the \u003cb\u003eMC125\u003c\/b\u003e maintaining optimal pH levels, you can reduce maintenance costs, minimize waste, and improve the overall efficiency of your operation. It also helps to extend the lifespan of equipment by preventing scaling or corrosion caused by incorrect pH levels.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use:\u003c\/b\u003e\u003c\/p\u003e\n\u003col style=\"margin-top: 0cm;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l11 level1 lfo11; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eInstall the pH Probe \u0026amp; Controller:\u003c\/b\u003e\u003cbr\u003ePlace the pH probe in the relevant section of your industrial system where pH needs to be monitored (e.g., chemical bath, wastewater treatment tank). Connect the \u003cb\u003eMC125\u003c\/b\u003e controller to the probe and set it up in a central location near your system controls. Ensure it is securely connected to a dosing pump (sold separately) for automatic chemical injection.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l11 level1 lfo11; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eSet Desired pH Range:\u003c\/b\u003e\u003cbr\u003eBased on your specific industrial process, input the ideal pH range for your operation into the \u003cb\u003eMC125\u003c\/b\u003e controller. For example, electroplating baths often require a pH range of \u003cb\u003e2-3\u003c\/b\u003e, while chemical processes may require a slightly different range depending on the chemicals involved.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l11 level1 lfo11; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eConnect the Dosing Pump:\u003c\/b\u003e\u003cbr\u003eLink the \u003cb\u003eMC125\u003c\/b\u003e to the dosing pump. The pump will automatically inject either acid or base solutions to adjust the pH as needed. This automated process will occur whenever the system detects that the pH is outside the preset range.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l11 level1 lfo11; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eMonitor pH in Real-Time:\u003c\/b\u003e\u003cbr\u003eWith the controller in place, the \u003cb\u003eMC125\u003c\/b\u003e will continuously track and adjust the pH of your process. Whenever the pH drifts beyond the set range, the controller will trigger the dosing pump to restore balance. This keeps your industrial processes running smoothly without needing constant manual checks.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l11 level1 lfo11; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eAdjust Settings as Needed:\u003c\/b\u003e\u003cbr\u003eYou can fine-tune the settings of the \u003cb\u003eMC125\u003c\/b\u003e to account for different stages of the process or adjustments in the required pH. For example, you might need a slightly more acidic environment at the start of a chemical reaction or a more neutral pH during the final steps of production.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l11 level1 lfo11; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eMaintain System Efficiency:\u003c\/b\u003e\u003cbr\u003eRegularly check the system to ensure that the pH probe is functioning correctly and that dosing solutions are available. The \u003cb\u003eMC125\u003c\/b\u003e will help streamline your operations, reduce human error, and maintain the ideal pH for your industrial processes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the \u003cb\u003eMC125\u003c\/b\u003e, you'll have a reliable, automated solution to keep your industrial processes on track, ensuring optimal product quality, regulatory compliance, and smooth operation across a range of applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56134995804533,"sku":"MC125","price":320.44,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/MC125copy_1920x1920_90185450-b879-4324-b9b1-44c8f7d00bb8.jpg?v=1761050797"},{"product_id":"milwaukee-mc745-pro-conductivity-ec-controller-and-pump-kits","title":"Milwaukee MC745 PRO Conductivity (EC) Controller and Pump Kits","description":"\u003cp\u003eThe Milwaukee MC745 PRO Conductivity (EC) controller and pump lets you measure and adjust EC levels automatically.\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch1\u003eCONTROL THE EC AND FERTILIZER DOSAGE IN YOUR TANK AUTOMATICALLY\u003c\/h1\u003e\n\u003cdiv\u003eThe MC745 kit includes the MC311 EC controller and two MP810 dosing pumps to automatically monitor and fine-tune EC levels. Just set your EC parameters and let the Milwaukee EC Controller and pumps do the rest.\u003c\/div\u003e\n\u003cdiv\u003eThe Milwaukee MC745 PRO controller kit is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks.\u003c\/div\u003e\n\u003cdiv\u003eThe Milwaukee PRO EC controller and pumps offers:\u003c\/div\u003e\n\u003ch4\u003eACCURACY\u003c\/h4\u003e\n\u003cdiv\u003eThe Milwaukee PRO EC controller offers an accuracy to ±2% full scale.\u003c\/div\u003e\n\u003ch4\u003eAUTOMATION\u003c\/h4\u003e\n\u003cdiv\u003eThe controller provides a control range of 0.0 to 10.0 mS\/cm with alarms that activate when readings are higher or lower than set point.\u003c\/div\u003e\n\u003ch4\u003eCOMPATIBLE DOSING PUMP\u003c\/h4\u003e\n\u003cdiv\u003eThe Milwaukee MP810 dosing pump (designed specifically for use with the MC311) is included in the kit.\u003c\/div\u003e\n\u003ch4\u003eEASY INSTALLATION\u003c\/h4\u003e\n\u003cdiv\u003eThe MC745 EC controller and pump kit comes with a complete mounting kit including a probe holder.\u003c\/div\u003e\n\u003ch3\u003eDESIGN FEATURES\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eFast easy to read current results with large digital LCD readout and visual LED alarm\u003c\/li\u003e\n\u003cli\u003eAccurate to ±2% full scale (0.0 pH to 10.0 mS\/cm) with the user selectable high\/low set points\u003c\/li\u003e\n\u003cli\u003eSimple one-point calibration for increased accuracy with manual trimmers for easy adjustment\u003c\/li\u003e\n\u003cli\u003eMA812\/2 hardwired EC probe included\u003c\/li\u003e\n\u003cli\u003e6.5 feet probe cables for extra flexibility when testing\u003c\/li\u003e\n\u003cli\u003e12 VDC power supply\u003c\/li\u003e\n\u003cli\u003ePump provides a maximum pressure of 1.5 bar or more than 50 feet of head pressure with a 0.16 GPM dosing flow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"specification-tab-pane\" role=\"tabpanel\" aria-labelledby=\"specification-tab\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eMC311 SPECIFICATIONS\u003c\/h3\u003e\n\u003cdiv\u003eRange: 0.0 - 10.0 mS\/cm\u003c\/div\u003e\n\u003cdiv\u003eResolution: 0.1 mS\/cm\u003c\/div\u003e\n\u003cdiv\u003eAccuracy: ±2% F.S.\u003c\/div\u003e\n\u003cdiv\u003eCalibration: Manual, 1-point\u003c\/div\u003e\n\u003cdiv\u003eSet point: 0.8 to 2.8 mS\/cm\u003c\/div\u003e\n\u003cdiv\u003eAlarm: Active when reading is higher or lower than set point\u003c\/div\u003e\n\u003cdiv\u003eTemperature Compensation: Automatic, from 0 to 50°C\u003c\/div\u003e\n\u003cdiv\u003eEC electrode: MA812\/2 (included)\u003c\/div\u003e\n\u003cdiv\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/div\u003e\n\u003cdiv\u003ePower Supply: 12 VDC adapter (included)\u003c\/div\u003e\n\u003cdiv\u003ePower Drivers: 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz\u003c\/div\u003e\n\u003cdiv\u003eMounting kit (Included)\u003c\/div\u003e\n\u003cdiv\u003eDimensions: 5.9 x 3.2 x 1.35 inches\u003c\/div\u003e\n\u003cdiv\u003eWeight: 6.3 ounces (meter only)\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eMP810 SPECIFICATIONS\u003c\/h3\u003e\n\u003cdiv\u003eMax. Flow: 0.6 L\/h\u003c\/div\u003e\n\u003cdiv\u003eMax. Pressure: 1.5 bar\u003c\/div\u003e\n\u003cdiv\u003eSqueeze tubing: Santoprene\u003c\/div\u003e\n\u003cdiv\u003eExt. Tube connection: 6 mm\u003c\/div\u003e\n\u003cdiv\u003ePower supply: 240 VAC, 50-60 Hz or 110 VAC, 60 Hz\u003c\/div\u003e\n\u003cdiv\u003ePower consumption: 0.42 W\u003c\/div\u003e\n\u003cdiv\u003eDimensions: 100 x 106 x 108 mm\u003c\/div\u003e\n\u003cdiv\u003eWeight: 17.6 oz.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56190670274933,"sku":"MC745","price":551.63,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/MC311_includes-EUROcopy_1920x1920_e054386d-6203-4989-91a1-347e3312a259.jpg?v=1761749039"},{"product_id":"milwaukee-mc811-max-ph-ec-temp-monitor","title":"Milwaukee MC811 MAX pH\/EC\/Temp Monitor","description":"\u003ch1 class=\"product-detail-name\" itemprop=\"name\"\u003eMilwaukee MC811 MAX pH\/EC\/Temp Monitor\u003c\/h1\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003eMilwaukee MC811 MAX pH\/EC\/Temp Monitor – Precision Monitoring for Optimal Water Quality\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eIn environments where water quality is paramount – be it hydroponic farms, aquariums, swimming pools, or industrial processes – accurate and continuous monitoring of pH, electrical conductivity (EC), and temperature is essential. The \u003cb\u003eMilwaukee MC811 MAX\u003c\/b\u003e is engineered to meet the demands of both professionals and serious hobbyists, offering a robust, easy-to-use solution that delivers real-time data, around-the-clock accuracy, and long-term reliability.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith its three large LCD displays and high-performance probes, the MC811 MAX helps you track critical water parameters at a glance – making it an ideal tool for anyone who needs to monitor nutrient concentration, chemical dosing, or water stability in a fixed location.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDesigned for Demanding Water Monitoring Needs\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe MC811 MAX is more than just a monitor – it’s a daily partner in precision. Whether you're optimizing growth conditions in a hydroponic setup or maintaining the delicate balance of an aquarium or aquaculture system, the MC811 MAX gives you confidence in your water’s condition. With continuous monitoring, you can catch shifts before they become problems, saving you time, resources, and costly setbacks.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBuilt to withstand continuous use, this monitor is ready for installation on-site with everything you need included: mounting brackets, high-quality pH and EC probes, and long cables for flexible placement. The gel-filled, double-junction pH electrode and fixed carbon EC probe are low maintenance and designed for durability, even in demanding environments.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eWhy Choose the Milwaukee MC811 MAX?\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eHigh Accuracy\u003c\/b\u003e: Achieve precise measurements with ±0.2 pH accuracy, ±2% full-scale EC accuracy, and ±0.5°F (±0.3°C) temperature accuracy.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eContinuous Monitoring\u003c\/b\u003e: Designed for 24\/7 operation, the MC811 MAX continuously displays pH, EC, and temperature readings, allowing for immediate detection of any fluctuations.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eUser-Friendly Interface\u003c\/b\u003e: Features three large, backlit LCD displays for easy reading of all parameters simultaneously.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eEasy Calibration\u003c\/b\u003e: Simple two-point manual calibration for pH and one-point calibration for EC ensures ongoing measurement accuracy.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eRobust Design\u003c\/b\u003e: Includes a gel-filled, double junction MA911B\/2 pH electrode and a fixed EC probe, both designed for low maintenance and high performance.\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eFlexible Installation\u003c\/b\u003e: Comes with a complete mounting kit and 6.5-foot probe cables, allowing for versatile placement options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe versatility of the MC811 MAX makes it suitable for a wide range of applications:\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eAgriculture \u0026amp; Hydroponics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eMaintaining optimal nutrient levels is crucial for plant health. The MC811 MAX allows growers to monitor and adjust pH and EC levels in nutrient solutions, ensuring plants receive the right balance of nutrients for maximum yield.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eAquariums \u0026amp; Aquaculture\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eAquatic life thrives in stable environments. The MC811 MAX helps aquarists and fish farmers maintain ideal water conditions by continuously monitoring pH, EC, and temperature, preventing harmful fluctuations that could stress or harm aquatic organisms.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eWater Treatment \u0026amp; Purification\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIn water treatment facilities, monitoring pH and EC is essential for assessing water quality and treatment efficiency. The MC811 MAX provides real-time data, aiding in the optimization of purification processes and ensuring compliance with water quality standards.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eFood \u0026amp; Beverage Industry\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eWater quality directly impacts product taste and safety. The MC811 MAX assists in monitoring the pH and EC of water used in food and beverage production, ensuring consistency and adherence to quality control measures.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eLaboratories \u0026amp; Research\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eFor scientific experiments requiring precise water quality conditions, the MC811 MAX offers reliable monitoring of pH, EC, and temperature, supporting accurate and reproducible research outcomes.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eEnvironmental Monitoring\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eEnvironmental scientists can utilize the MC811 MAX to monitor natural water bodies, detecting changes in pH and EC that may indicate pollution or ecological shifts, thereby aiding in environmental protection efforts.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eProper Care \u0026amp; Maintenance\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003epH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eSensing bulb\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eReference junction\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eYou can extend the life of your pH electrode in the following ways.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eStorage\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eStoring in pH probe storage solution or pH calibration buffers will help address both these issues. Do not store in tap water and DI water. This will damage the sensitivity of the probe.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe best way to store the probe is with the probe's cap filled with storage solution or calibiration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eCleaning\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eResidue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eCalibration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eThe pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your MAX monitor accurate. Also, calibrate after cleaning or a long period of storage.\u003c\/p\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"specification-tab-pane\" role=\"tabpanel\" aria-labelledby=\"specification-tab\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003epH Range: 0.0 - 12.0 pH \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003epH Resolution: 0.1 pH \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003epH Accuracy: ±0.2 pH \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003epH Calibration: Manual, 2 points (trimmer) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003epH Probe: MA911B\/2 (included) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eEC Range: 0.00 - 5.00 mS\/cm \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eEC Resolution: 0.01 mS\/cm \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eEC Accuracy: ±2% Full Scale \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eEC Calibration: manual, 1 point (trimmer) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eEC Probe: MA812 (fixed, Included)\u003c\/div\u003e\n\u003cdiv\u003eTemperature Range: 14.0 to 140.0°F (-10.0 to 60.0°C) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTemperature Resolution: 0.1°F \/ 0.1°C \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTemperature Accuracy: ±0.5°F \/ ±0.3°C \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTemperature Calibration: Factory Calibrated Temperature Compensation: Automatic, 41 to 122°F (5 to 50°C), (TDS \/ EC Readings Only) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTemperature Probe: Stainless Steel (fixed, included) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003ePower Supply: 12 VDC adapter (included) Dimensions: 6.3\" x 4.3\" x 1.4\" (160 mm x 110 mm x 35 mm )\u003c\/div\u003e\n\u003cdiv\u003eMounting kit: (Included) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eWeight: 1.2 lbs. (560 g)\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"application-tab-pane\" role=\"tabpanel\" aria-labelledby=\"application-tab\"\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eHydroponics \u0026amp; Horticulture\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn hydroponic and horticultural systems, plants grow without soil, relying entirely on nutrient-rich water solutions. This makes water quality management critical, as even small imbalances in pH or nutrient concentration (measured via electrical conductivity, or EC) can have immediate and visible effects on plant health.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003epH\u003c\/b\u003e determines how easily plants can absorb nutrients. If the pH is too low (acidic) or too high (alkaline), essential nutrients like nitrogen, phosphorus, and potassium become less available – even if they are present in the solution. This can lead to \u003cb\u003enutrient lockout\u003c\/b\u003e, a condition where plants show deficiency symptoms despite adequate feeding.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEC\u003c\/b\u003e reflects the total concentration of dissolved salts, essentially telling you how \"strong\" or \"weak\" your nutrient solution is. If the EC is too low, your plants may not get enough food. Too high, and you risk \u003cb\u003enutrient toxicity\u003c\/b\u003e, root burn, or osmotic stress, where the roots can't properly absorb water.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMC811 MAX\u003c\/b\u003e gives you \u003cb\u003ereal-time visibility\u003c\/b\u003e into all three essential factors: pH, EC, and temperature. This means you can:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l38 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eIdentify issues before they affect growth\u003c\/b\u003e\u003c\/li\u003e\n\u003cli style=\"mso-list: l38 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eMake precise adjustments to nutrient dosing\u003c\/b\u003e\u003c\/li\u003e\n\u003cli style=\"mso-list: l38 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eMaintain ideal growing conditions 24\/7\u003c\/b\u003e\u003c\/li\u003e\n\u003cli style=\"mso-list: l38 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eReduce waste by preventing overfeeding or incorrect pH corrections\u003c\/b\u003e\u003c\/li\u003e\n\u003cli style=\"mso-list: l38 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eBoost plant yield, quality, and consistency\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the \u003cb\u003eMC811 MAX\u003c\/b\u003e, hydroponic growers can achieve \u003cb\u003eprecision feeding and environmental control\u003c\/b\u003e – leading to healthier plants, faster growth, and more predictable harvests. Whether you're managing a hobby greenhouse or a commercial grow operation, this monitor ensures you never lose sight of what’s happening in your root zone.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC811 MAX in Hydroponics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l50 level1 lfo2; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e1.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eInstallation\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l19 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMount the MC811 MAX in a convenient, visible location near your nutrient reservoir or grow system.\u003c\/li\u003e\n\u003cli style=\"mso-list: l19 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eUse the included bracket and screws to secure the device safely.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l50 level1 lfo2; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e2.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eProbe Placement\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l12 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eInsert the \u003cb\u003epH\u003c\/b\u003e and \u003cb\u003eEC\/temperature\u003c\/b\u003e probes into the reservoir or nutrient flow system.\u003c\/li\u003e\n\u003cli style=\"mso-list: l12 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eEnsure the probes are fully submerged and in a location with good water circulation for accurate readings.\u003c\/li\u003e\n\u003cli style=\"mso-list: l12 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eUse the provided probe holders or cable supports to prevent strain or movement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l50 level1 lfo2; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e3.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eCalibration\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l15 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCalibrate the pH and EC probes using the appropriate \u003cb\u003eMilwaukee calibration solutions\u003c\/b\u003e before first use and regularly thereafter.\u003c\/li\u003e\n\u003cli style=\"mso-list: l15 level1 lfo5; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eFollow the user manual prompts to perform a \u003cb\u003e2-point calibration for pH\u003c\/b\u003e and \u003cb\u003e1-point calibration for EC\u003c\/b\u003e to ensure accurate readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l50 level1 lfo2; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e4.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eMonitoring\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l22 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eOnce installed and calibrated, the monitor will continuously display real-time readings of pH, EC, and temperature.\u003c\/li\u003e\n\u003cli style=\"mso-list: l22 level1 lfo6; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCheck the display during feeding, topping up, or when adjusting nutrient mixes to ensure levels are within optimal ranges for your crops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l50 level1 lfo2; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e5.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eIntervention\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf readings drift out of the ideal range (e.g., pH 5.5–6.5 for most hydroponic crops, or EC 1.0–2.5 mS\/cm depending on growth stage), you can take immediate action:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l31 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAdjust pH using pH Up\/Down solutions\u003c\/li\u003e\n\u003cli style=\"mso-list: l31 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDilute or strengthen your nutrient mix based on EC\u003c\/li\u003e\n\u003cli style=\"mso-list: l31 level1 lfo7; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eEnsure the water temperature is within the recommended range for nutrient uptake (typically 18–22°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 18.0pt; text-indent: -18.0pt; mso-list: l50 level1 lfo2; tab-stops: list 18.0pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"mso-bidi-font-family: Aptos; mso-bidi-theme-font: minor-latin;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e6.\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eMaintenance\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l21 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRinse the probes regularly with clean water.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l21 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eStore the pH probe with proper \u003cb\u003estorage solution\u003c\/b\u003e when not in use.\u003c\/p\u003e\n\u003cp style=\"text-indent: -18.0pt; mso-list: l21 level1 lfo8; tab-stops: list 36.0pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eReplace calibration solutions regularly and recalibrate as needed to maintain accuracy.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e  \u003cbr\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eAquariums \u0026amp; Aquaculture\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're maintaining a home aquarium or operating a commercial fish farm, \u003cb\u003ewater quality is everything\u003c\/b\u003e. Aquatic animals are highly sensitive to changes in their environment, and parameters like \u003cb\u003epH\u003c\/b\u003e, \u003cb\u003etemperature\u003c\/b\u003e, and \u003cb\u003eelectrical conductivity (EC)\u003c\/b\u003e directly impact their health, stress levels, growth, and reproduction.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn an aquarium or aquaculture system, pH affects the \u003cb\u003etoxicity of ammonia\u003c\/b\u003e, a waste product that can be deadly at high levels. For example, at a higher pH, ammonia becomes more toxic. Keeping pH within a safe, species-appropriate range is essential for fish, corals, and invertebrates.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEC\u003c\/b\u003e, which reflects the total dissolved salts or minerals in the water, plays a critical role in \u003cb\u003eosmoregulation\u003c\/b\u003e – how fish maintain the balance of fluids and electrolytes in their bodies. While freshwater and marine species require different salinity ranges, even within those environments, excessive changes in EC can cause stress or illness.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eTemperature\u003c\/b\u003e regulates metabolic rates, oxygen levels, and immune function. Sudden fluctuations can weaken fish, promote disease, or even cause death, especially for temperature-sensitive tropical species or breeding stock.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMC811 MAX\u003c\/b\u003e is designed to provide \u003cb\u003ereal-time, continuous monitoring\u003c\/b\u003e of all three parameters, helping aquarists and aquaculture professionals:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l17 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDetect issues before they escalate\u003c\/li\u003e\n\u003cli style=\"mso-list: l17 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMaintain a stable and healthy environment\u003c\/li\u003e\n\u003cli style=\"mso-list: l17 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eReduce fish loss and improve welfare\u003c\/li\u003e\n\u003cli style=\"mso-list: l17 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eOptimize breeding and growth conditions\u003c\/li\u003e\n\u003cli style=\"mso-list: l17 level1 lfo9; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePrevent stress-related diseases and behavioral changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're caring for ornamental fish, raising edible species like tilapia or shrimp, or maintaining sensitive coral reef tanks, the MC811 MAX delivers the accuracy and reliability needed to keep aquatic life thriving.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC811 MAX in Aquariums \u0026amp; Aquaculture\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eInstallation\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l65 level1 lfo15; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMount the MC811 MAX in a dry, visible area near the tank or aquaculture system using the included bracket.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l65 level1 lfo15; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eEnsure the monitor is placed at a height where readings are easy to observe without risking water splashes.\u003c\/p\u003e\n\u003col type=\"1\" start=\"2\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eProbe Placement\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l52 level1 lfo14; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eSubmerge the \u003cb\u003epH\u003c\/b\u003e and \u003cb\u003eEC\/temperature\u003c\/b\u003e probes into the aquarium or tank.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l52 level1 lfo14; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eFor best results, place the probes in an area with consistent water circulation (not near filters or stagnant zones).\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l52 level1 lfo14; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse probe holders to prevent movement, stress on cables, or accidental dislodging by animals or equipment.\u003c\/p\u003e\n\u003col type=\"1\" start=\"3\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eCalibration\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l40 level1 lfo13; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCalibrate the \u003cb\u003epH\u003c\/b\u003e and \u003cb\u003eEC\u003c\/b\u003e probes before first use using certified Milwaukee calibration solutions.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l40 level1 lfo13; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePerform a \u003cb\u003e2-point calibration\u003c\/b\u003e for pH and a \u003cb\u003e1-point calibration\u003c\/b\u003e for EC, following the monitor’s user instructions.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l40 level1 lfo13; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRecalibrate periodically (e.g., monthly or as needed) to maintain measurement accuracy.\u003c\/p\u003e\n\u003col type=\"1\" start=\"4\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eMonitoring\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l26 level1 lfo12; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eThe MC811 MAX will continuously display up-to-date values for pH, EC, and temperature.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l26 level1 lfo12; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMonitor these values daily to identify any drift or sudden changes that may indicate biological or mechanical issues (e.g., equipment failure, overfeeding, or water contamination).\u003c\/p\u003e\n\u003col type=\"1\" start=\"5\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo10; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eResponding to Readings\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 36.0pt;\" class=\"MsoNormal\"\u003eTake corrective action when needed:\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l39 level1 lfo11; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eIf pH is out of range, adjust with aquarium-safe buffers.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l39 level1 lfo11; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eIf EC rises unexpectedly, check for overfeeding, evaporation, or build-up of minerals—partial water changes may help.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l39 level1 lfo11; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eIf temperature shifts, inspect heaters, chillers, or ambient conditions.\u003c\/p\u003e\n\u003cp style=\"margin-left: 36.0pt;\" class=\"MsoNormal\"\u003eKeeping parameters consistent is especially important for sensitive species and during breeding cycles.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eSwimming Pools \u0026amp; Spas\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn pools and spas, water quality isn’t just about aesthetics – it’s essential for \u003cb\u003ehealth, safety, comfort, and equipment longevity\u003c\/b\u003e. When the pH level strays from the ideal range or conductivity spikes due to excess salts and dissolved solids, swimmers may experience \u003cb\u003eskin and eye irritation\u003c\/b\u003e, \u003cb\u003ecorrosive damage\u003c\/b\u003e can occur to heaters and pumps, and \u003cb\u003echlorine efficiency\u003c\/b\u003e can be drastically reduced.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC811 MAX\u003c\/b\u003e helps pool operators, maintenance professionals, and spa owners take full control over water chemistry by continuously monitoring \u003cb\u003epH\u003c\/b\u003e, \u003cb\u003eelectrical conductivity (EC)\u003c\/b\u003e, and \u003cb\u003etemperature\u003c\/b\u003e – the three pillars of effective pool water management.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eWhy pH \u0026amp; EC Monitoring Matters in Pools and Spas:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l10 level1 lfo24; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003epH\u003c\/b\u003e regulates chlorine effectiveness. If pH is too high, chlorine becomes sluggish and ineffective; if too low, it becomes aggressive and corrosive.\u003c\/li\u003e\n\u003cli style=\"mso-list: l10 level1 lfo24; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eOptimal pH range:\u003c\/b\u003e 7.2–7.6 for most pools and spas\u003c\/li\u003e\n\u003cli style=\"mso-list: l10 level1 lfo24; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eEC (electrical conductivity)\u003c\/b\u003e gives an indication of \u003cb\u003etotal dissolved solids (TDS)\u003c\/b\u003e such as minerals, salts, or chemical residues. High EC levels can lead to cloudy water, scaling, and reduced sanitizer performance.\u003c\/li\u003e\n\u003cli style=\"mso-list: l10 level1 lfo24; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eTemperature monitoring\u003c\/b\u003e is crucial, especially for spas, to ensure user comfort and prevent overheating or inefficiency of thermal systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBy using the MC811 MAX, you gain a \u003cb\u003ereal-time window\u003c\/b\u003e into these crucial water parameters, helping you to keep water crystal clear and safe, prevent chemical imbalances before they become problems, reduce chemical waste through more precise dosing and extend the life of pool infrastructure and filtration systems\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're managing a private backyard pool, a hotel spa, or a commercial wellness facility, the MC811 MAX brings \u003cb\u003elab-grade precision\u003c\/b\u003e into your daily maintenance routine.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC811 MAX in Swimming Pools \u0026amp; Spas\u003c\/b\u003e\u003c\/p\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo25; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eSetup and Installation\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l59 level1 lfo32; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMount the MC811 MAX monitor in a shaded, splash-protected area near the filtration system or pump room.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l59 level1 lfo32; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eEnsure the display is easily viewable for daily checks.\u003c\/p\u003e\n\u003col type=\"1\" start=\"2\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo25; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eProbe Placement\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l60 level1 lfo31; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eInstall the \u003cb\u003epH\u003c\/b\u003e and \u003cb\u003eEC\/temperature\u003c\/b\u003e probes in a \u003cb\u003eflow-through pipe\u003c\/b\u003e, \u003cb\u003esampling line\u003c\/b\u003e, or \u003cb\u003ebypass line\u003c\/b\u003e where treated water circulates.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l60 level1 lfo31; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eAvoid placing probes directly into stagnant or turbulent water to ensure accurate and stable readings.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l60 level1 lfo31; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse protective housings or probe holders to shield them from physical damage and prevent fouling.\u003c\/p\u003e\n\u003col type=\"1\" start=\"3\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo25; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eCalibration\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l18 level1 lfo30; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePerform regular calibration using \u003cb\u003eMilwaukee pH buffer solutions\u003c\/b\u003e (e.g., pH 7.01 and pH 4.01 or 10.01) and \u003cb\u003eEC standard solution\u003c\/b\u003e (e.g., 1413 µS\/cm).\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l18 level1 lfo30; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCalibrate before the first use, after extended storage, or if readings become unstable.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l18 level1 lfo30; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eFor optimal accuracy, calibrate at least \u003cb\u003emonthly\u003c\/b\u003e, or \u003cb\u003eweekly\u003c\/b\u003e for high-use commercial systems.\u003c\/p\u003e\n\u003col type=\"1\" start=\"4\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo25; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eDaily Monitoring\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l45 level1 lfo29; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse the digital display to check the current values of pH, EC, and temperature at a glance.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l45 level1 lfo29; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eSet internal alarms or create manual alerts if values drift outside of safe ranges:\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003epH: 7.2–7.6\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eEC: varies by pool\/spa size and local water supply, typically \u0026lt;2000 µS\/cm for clean water\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eTemperature: ~26–30°C (78–86°F) for pools; up to 40°C (104°F) for spas\u003c\/p\u003e\n\u003col type=\"1\" start=\"5\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo25; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eInterpreting Readings\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l3 level1 lfo28; tab-stops: list 53.4pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003epH too high?\u003c\/b\u003e Add acid (like muriatic acid) to bring it down.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l3 level1 lfo28; tab-stops: list 53.4pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003epH too low?\u003c\/b\u003e Add a pH increaser (like soda ash).\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l3 level1 lfo28; tab-stops: list 53.4pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eEC rising?\u003c\/b\u003e Indicates buildup of chemicals – consider partial water replacement.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l3 level1 lfo28; tab-stops: list 53.4pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eTemperature fluctuation?\u003c\/b\u003e Check heating or circulation systems.\u003c\/p\u003e\n\u003col type=\"1\" start=\"6\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo25; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eMaintenance Tips\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l35 level1 lfo27; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eClean probes weekly or biweekly, especially in outdoor pools or spas with high bather loads.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l35 level1 lfo27; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eSoak pH probe in \u003cb\u003eMilwaukee MA9015 storage solution\u003c\/b\u003e when not in use to preserve lifespan.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l35 level1 lfo27; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRinse probes with clean water after exposure to heavy dosing or cleaning chemicals.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l35 level1 lfo27; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eReplace probes when calibration becomes difficult or readings are erratic even after cleaning.\u003c\/p\u003e\n\u003col type=\"1\" start=\"7\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo25; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eRecordkeeping \u0026amp; Safety\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l36 level1 lfo26; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eLog readings daily for troubleshooting, warranty support, or compliance with pool safety regulations.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l36 level1 lfo26; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse the MC811 MAX to \u003cb\u003eoptimize chemical use\u003c\/b\u003e, reducing operating costs and environmental impact.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the \u003cb\u003eMC811 MAX\u003c\/b\u003e, you're not just testing your pool water – you’re mastering it. This robust, precision instrument turns guesswork into actionable insight, making your pool or spa safer, clearer, and more enjoyable for everyone.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eSwimming Pools \u0026amp; Spas\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn pools and spas, water quality isn’t just about aesthetics – it’s essential for \u003cb\u003ehealth, safety, comfort, and equipment longevity\u003c\/b\u003e. When the pH level strays from the ideal range or conductivity spikes due to excess salts and dissolved solids, swimmers may experience \u003cb\u003eskin and eye irritation\u003c\/b\u003e, \u003cb\u003ecorrosive damage\u003c\/b\u003e can occur to heaters and pumps, and \u003cb\u003echlorine efficiency\u003c\/b\u003e can be drastically reduced.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC811 MAX\u003c\/b\u003e helps pool operators, maintenance professionals, and spa owners take full control over water chemistry by continuously monitoring \u003cb\u003epH\u003c\/b\u003e, \u003cb\u003eelectrical conductivity (EC)\u003c\/b\u003e, and \u003cb\u003etemperature\u003c\/b\u003e – the three pillars of effective pool water management.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eWhy pH \u0026amp; EC Monitoring Matters in Pools and Spas:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l41 level1 lfo33; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003epH\u003c\/b\u003e regulates chlorine effectiveness. If pH is too high, chlorine becomes sluggish and ineffective; if too low, it becomes aggressive and corrosive.\u003c\/li\u003e\n\u003cli style=\"mso-list: l41 level1 lfo33; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eOptimal pH range:\u003c\/b\u003e 7.2–7.6 for most pools and spas\u003c\/li\u003e\n\u003cli style=\"mso-list: l41 level1 lfo33; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eEC (electrical conductivity)\u003c\/b\u003e gives an indication of \u003cb\u003etotal dissolved solids (TDS)\u003c\/b\u003e such as minerals, salts, or chemical residues. High EC levels can lead to cloudy water, scaling, and reduced sanitizer performance.\u003c\/li\u003e\n\u003cli style=\"mso-list: l41 level1 lfo33; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eTemperature monitoring\u003c\/b\u003e is crucial, especially for spas, to ensure user comfort and prevent overheating or inefficiency of thermal systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBy using the MC811 MAX, you gain a \u003cb\u003ereal-time window\u003c\/b\u003e into these crucial water parameters, helping you to keep water crystal clear and safe, prevent chemical imbalances before they become problems, reduce chemical waste through more precise dosing and to extend the life of pool infrastructure and filtration systems\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're managing a private backyard pool, a hotel spa, or a commercial wellness facility, the MC811 MAX brings \u003cb\u003elab-grade precision\u003c\/b\u003e into your daily maintenance routine.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC811 MAX in Swimming Pools \u0026amp; Spas\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l27 level1 lfo34; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eSetup and Installation\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l58 level1 lfo41; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMount the MC811 MAX monitor in a shaded, splash-protected area near the filtration system or pump room.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l58 level1 lfo41; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eEnsure the display is easily viewable for daily checks.\u003c\/p\u003e\n\u003col type=\"1\" start=\"2\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l27 level1 lfo34; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eProbe Placement\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l54 level1 lfo40; tab-stops: list 53.4pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eInstall the \u003cb\u003epH\u003c\/b\u003e and \u003cb\u003eEC\/temperature\u003c\/b\u003e probes in a \u003cb\u003eflow-through pipe\u003c\/b\u003e, \u003cb\u003esampling line\u003c\/b\u003e, or \u003cb\u003ebypass line\u003c\/b\u003e where treated water circulates.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l54 level1 lfo40; tab-stops: list 53.4pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eAvoid placing probes directly into stagnant or turbulent water to ensure accurate and stable readings.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l54 level1 lfo40; tab-stops: list 53.4pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse protective housings or probe holders to shield them from physical damage and prevent fouling.\u003c\/p\u003e\n\u003col type=\"1\" start=\"3\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l27 level1 lfo34; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eCalibration\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l63 level1 lfo39; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePerform regular calibration using \u003cb\u003eMilwaukee pH buffer solutions\u003c\/b\u003e (e.g., pH 7.01 and pH 4.01 or 10.01) and \u003cb\u003eEC standard solution\u003c\/b\u003e (e.g., 1413 µS\/cm).\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l63 level1 lfo39; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCalibrate before the first use, after extended storage, or if readings become unstable.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l63 level1 lfo39; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eFor optimal accuracy, calibrate at least \u003cb\u003emonthly\u003c\/b\u003e, or \u003cb\u003eweekly\u003c\/b\u003e for high-use commercial systems.\u003c\/p\u003e\n\u003col type=\"1\" start=\"4\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l27 level1 lfo34; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eDaily Monitoring\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l37 level1 lfo38; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse the digital display to check the current values of pH, EC, and temperature at a glance.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l37 level1 lfo38; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eSet internal alarms or create manual alerts if values drift outside of safe ranges:\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003epH: 7.2–7.6\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eEC: varies by pool\/spa size and local water supply, typically \u0026lt;2000 µS\/cm for clean water\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eTemperature: ~26–30°C (78–86°F) for pools; up to 40°C (104°F) for spas\u003c\/p\u003e\n\u003col type=\"1\" start=\"5\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l27 level1 lfo34; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eInterpreting Readings\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l23 level1 lfo37; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003epH too high?\u003c\/b\u003e Add acid (like muriatic acid) to bring it down.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l23 level1 lfo37; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003epH too low?\u003c\/b\u003e Add a pH increaser (like soda ash).\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l23 level1 lfo37; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eEC rising?\u003c\/b\u003e Indicates buildup of chemicals – consider partial water replacement.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l23 level1 lfo37; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eTemperature fluctuation?\u003c\/b\u003e Check heating or circulation systems.\u003c\/p\u003e\n\u003col type=\"1\" start=\"6\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l27 level1 lfo34; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eMaintenance Tips\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l11 level1 lfo36; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eClean probes weekly or biweekly, especially in outdoor pools or spas with high bather loads.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l11 level1 lfo36; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eSoak pH probe in \u003cb\u003eMilwaukee MA9015 storage solution\u003c\/b\u003e when not in use to preserve lifespan.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l11 level1 lfo36; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRinse probes with clean water after exposure to heavy dosing or cleaning chemicals.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l11 level1 lfo36; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eReplace probes when calibration becomes difficult or readings are erratic even after cleaning.\u003c\/p\u003e\n\u003col type=\"1\" start=\"7\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l27 level1 lfo34; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eRecordkeeping \u0026amp; Safety\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l51 level1 lfo35; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eLog readings daily for troubleshooting, warranty support, or compliance with pool safety regulations.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l51 level1 lfo35; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse the MC811 MAX to \u003cb\u003eoptimize chemical use\u003c\/b\u003e, reducing operating costs and environmental impact.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the \u003cb\u003eMC811 MAX\u003c\/b\u003e, you're not just testing your pool water – you’re mastering it. This robust, precision instrument turns guesswork into actionable insight, making your pool or spa safer, clearer, and more enjoyable for everyone.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eLaboratories \u0026amp; Education\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn academic institutions, research labs, and educational facilities, \u003cb\u003eprecision, repeatability, and data integrity\u003c\/b\u003e are critical to every experiment. Whether conducting long-term environmental studies, teaching practical chemistry, or simulating hydroponic systems in the classroom, \u003cb\u003eaccurate water quality monitoring\u003c\/b\u003e is foundational to scientific success.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC811 MAX\u003c\/b\u003e is designed to meet these rigorous standards, providing \u003cb\u003econtinuous, high-resolution measurements\u003c\/b\u003e of \u003cb\u003epH\u003c\/b\u003e, \u003cb\u003eelectrical conductivity (EC)\u003c\/b\u003e, and \u003cb\u003etemperature\u003c\/b\u003e. This real-time monitoring solution allows researchers, educators, and students to observe and analyze changes over time with \u003cb\u003egreater consistency\u003c\/b\u003e and \u003cb\u003eless manual intervention\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIdeal Applications in Laboratories \u0026amp; Education:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l28 level1 lfo42; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eWater chemistry analysis\u003c\/b\u003e and titration labs\u003c\/li\u003e\n\u003cli style=\"mso-list: l28 level1 lfo42; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eEnvironmental science experiments\u003c\/b\u003e, including water pollution and remediation studies\u003c\/li\u003e\n\u003cli style=\"mso-list: l28 level1 lfo42; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003ePlant biology and hydroponics research\u003c\/b\u003e\u003c\/li\u003e\n\u003cli style=\"mso-list: l28 level1 lfo42; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eAquatic ecosystems monitoring\u003c\/b\u003e\u003c\/li\u003e\n\u003cli style=\"mso-list: l28 level1 lfo42; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003ePhysics or chemistry demonstrations\u003c\/b\u003e involving ionic concentration and thermodynamics\u003c\/li\u003e\n\u003cli style=\"mso-list: l28 level1 lfo42; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eEngineering projects\u003c\/b\u003e involving sensors, controls, or automation\u003c\/li\u003e\n\u003cli style=\"mso-list: l28 level1 lfo42; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSTEM classrooms\u003c\/b\u003e, where hands-on data improves student understanding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBy using the MC811 MAX in labs or classrooms, you can ensure stable and replicable conditions in long-term experiments, reduce user error through real-time digital readouts, demonstrate scientific principles interactively and accurately, support data logging, comparisons, and trend analysis over time and minimize the need for manual sampling or repeated probe dipping\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're educating future scientists or performing groundbreaking research, the MC811 MAX becomes a \u003cb\u003etrusted monitoring assistant\u003c\/b\u003e, freeing up time while enhancing reliability.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e \u003cb\u003eHow to Use the MC811 MAX in Laboratories \u0026amp; Educational Settings\u003c\/b\u003e\n\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l57 level1 lfo43; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eInitial Setup\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l42 level1 lfo50; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMount the MC811 MAX unit near the experiment station, lab bench, or inside a controlled growth\/environment chamber.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l42 level1 lfo50; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePlug it into a standard power outlet; no batteries or handheld meter handling required.\u003c\/p\u003e\n\u003col type=\"1\" start=\"2\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l57 level1 lfo43; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eProbe Placement\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l13 level1 lfo49; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePlace the \u003cb\u003epH\u003c\/b\u003e and \u003cb\u003eEC\/temperature\u003c\/b\u003e probes in a beaker, flask, nutrient reservoir, or tank depending on your setup.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l13 level1 lfo49; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eFor environmental or aquatic experiments, submerge probes in a \u003cb\u003erepresentative water sample\u003c\/b\u003e or real-time flow cell.\u003c\/p\u003e\n\u003col type=\"1\" start=\"3\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l57 level1 lfo43; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eCalibration\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l43 level1 lfo48; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePerform a \u003cb\u003etwo-point calibration\u003c\/b\u003e for the pH probe using standard buffer solutions (pH 7.01 and pH 4.01 or 10.01).\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l43 level1 lfo48; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCalibrate the EC probe with a \u003cb\u003estandard conductivity solution\u003c\/b\u003e (e.g., 1413 µS\/cm or 12880 µS\/cm).\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l43 level1 lfo48; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCalibration is crucial before experiments and whenever measurements must meet high precision standards.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l43 level1 lfo48; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse calibration logs to support academic documentation or research reproducibility.\u003c\/p\u003e\n\u003col type=\"1\" start=\"4\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l57 level1 lfo43; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eReal-Time Monitoring\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l14 level1 lfo47; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eReadings for \u003cb\u003epH\u003c\/b\u003e, \u003cb\u003eEC\u003c\/b\u003e, and \u003cb\u003etemperature\u003c\/b\u003e are continuously displayed – ideal for experiments requiring constant conditions or tracking gradual shifts.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l14 level1 lfo47; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse this live data to make observations, adjust conditions, or trigger interventions such as dosing, aeration, or heating.\u003c\/p\u003e\n\u003col type=\"1\" start=\"5\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l57 level1 lfo43; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eRecording \u0026amp; Analysis\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l20 level1 lfo46; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eStudents or researchers can record values manually or set intervals for logging (if integrated with external data acquisition tools).\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l20 level1 lfo46; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCompare data across trials or over time to study:\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eReaction rates\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003ePlant uptake and growth\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eIon concentration changes\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eEnvironmental impact simulations\u003c\/p\u003e\n\u003col type=\"1\" start=\"6\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l57 level1 lfo43; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eMaintenance\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l29 level1 lfo45; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRinse probes thoroughly between uses to avoid cross-contamination between experiments.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l29 level1 lfo45; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eStore the pH probe in \u003cb\u003estorage solution\u003c\/b\u003e (never dry) to maintain electrode health.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l29 level1 lfo45; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eClean probes periodically using appropriate solutions to prevent buildup or signal drift.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l29 level1 lfo45; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eReplace probes after extensive use or if calibration becomes unreliable.\u003c\/p\u003e\n\u003col type=\"1\" start=\"7\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l57 level1 lfo43; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eTeaching Tips\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l25 level1 lfo44; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse the MC811 MAX as part of a \u003cb\u003edemonstration station\u003c\/b\u003e in science labs.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l25 level1 lfo44; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eTeach students how to interpret pH, EC, and temperature data in real-time.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l25 level1 lfo44; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eEncourage hands-on calibration as part of lab technique training.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l25 level1 lfo44; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCombine with lessons on the chemistry of acids\/bases, nutrient solutions, or thermodynamics.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe MC811 MAX empowers both \u003cb\u003eeducators\u003c\/b\u003e and \u003cb\u003einvestigators\u003c\/b\u003e with dependable monitoring and professional-grade accuracy. It bridges the gap between theory and application, making scientific inquiry more interactive, insightful, and trustworthy.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eFood \u0026amp; Beverage Processing\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn the food and beverage industry, \u003cb\u003ewater quality is a critical control point\u003c\/b\u003e – affecting everything from product flavor and shelf life to food safety and regulatory compliance. Whether used as a direct ingredient, for cleaning equipment, or in the production process (e.g., brewing, blanching, or fermentation), water must meet \u003cb\u003estrict physicochemical standards\u003c\/b\u003e to maintain consistency and consumer safety.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC811 MAX\u003c\/b\u003e provides continuous, accurate monitoring of \u003cb\u003epH\u003c\/b\u003e, \u003cb\u003eelectrical conductivity (EC)\u003c\/b\u003e, and \u003cb\u003etemperature\u003c\/b\u003e – key parameters that directly influence water purity and process efficiency. By installing this monitor in strategic stages of the production line, you can ensure that water meets your \u003cb\u003eHACCP\u003c\/b\u003e (Hazard Analysis Critical Control Points) or \u003cb\u003eISO 22000\u003c\/b\u003e standards before it interacts with ingredients or processing equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eWhy pH \u0026amp; EC Matter in Food \u0026amp; Beverage Water Monitoring:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l47 level1 lfo51; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003epH affects product quality\u003c\/b\u003e – in brewing, cheese making, fermentation, and beverage pH, even slight variations can result in inconsistent taste, color, or microbial activity.\u003c\/li\u003e\n\u003cli style=\"mso-list: l47 level1 lfo51; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eEC indicates mineral content or total dissolved solids (TDS)\u003c\/b\u003e, which can affect the flavor, appearance, or performance of processing equipment (e.g., boilers, reverse osmosis systems).\u003c\/li\u003e\n\u003cli style=\"mso-list: l47 level1 lfo51; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eTemperature control\u003c\/b\u003e is vital for process consistency, sanitization effectiveness, and fermentation dynamics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWith the MC811 MAX, food processors and beverage makers can:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l46 level1 lfo52; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMonitor and control input water and rinse water quality in real time\u003c\/li\u003e\n\u003cli style=\"mso-list: l46 level1 lfo52; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eEnsure repeatability in recipes that depend on consistent water chemistry\u003c\/li\u003e\n\u003cli style=\"mso-list: l46 level1 lfo52; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePrevent scale buildup or corrosion in steam, heating, or pasteurization equipment\u003c\/li\u003e\n\u003cli style=\"mso-list: l46 level1 lfo52; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMinimize downtime from unexpected water quality deviations\u003c\/li\u003e\n\u003cli style=\"mso-list: l46 level1 lfo52; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDocument compliance for audits and traceability programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're bottling spring water, crafting beer, processing dairy, or preparing ready-made meals, the MC811 MAX offers a \u003cb\u003epractical, continuous solution\u003c\/b\u003e for protecting product integrity and operational reliability.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003e How to Use the MC811 MAX in Food \u0026amp; Beverage Production\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l61 level1 lfo53; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eInstallation \u0026amp; Setup\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l7 level1 lfo60; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMount the monitor near the water intake, blending tanks, or process line, preferably in a \u003cb\u003eclean-in-place (CIP)-compatible\u003c\/b\u003e area with access to power.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l7 level1 lfo60; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eEnsure display is visible to plant operators or integrated into a monitoring panel.\u003c\/p\u003e\n\u003col type=\"1\" start=\"2\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l61 level1 lfo53; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eProbe Integration\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l62 level1 lfo59; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eInsert the \u003cb\u003epH\u003c\/b\u003e and \u003cb\u003eEC\/temperature\u003c\/b\u003e probes into a \u003cb\u003eflow-through pipe\u003c\/b\u003e, \u003cb\u003esampling loop\u003c\/b\u003e, or \u003cb\u003esensor well\u003c\/b\u003e where water is circulating continuously (e.g., pre-mixing or pre-boiling stages).\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l62 level1 lfo59; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eFor food-contact areas, use \u003cb\u003efood-grade probe holders\u003c\/b\u003e or housings made of stainless steel or approved plastics.\u003c\/p\u003e\n\u003col type=\"1\" start=\"3\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l61 level1 lfo53; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eCalibration\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l64 level1 lfo58; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCalibrate pH and EC probes using \u003cb\u003etraceable calibration solutions\u003c\/b\u003e:\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003epH: Use pH 7.01 and either pH 4.01 or 10.01 depending on your target range.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eEC: Use standards such as 1413 µS\/cm or 12880 µS\/cm.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l64 level1 lfo58; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCalibrate at least \u003cb\u003eweekly\u003c\/b\u003e, or \u003cb\u003edaily\u003c\/b\u003e in critical control areas, and always before a production batch or shift.\u003c\/p\u003e\n\u003col type=\"1\" start=\"4\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l61 level1 lfo53; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eReal-Time Monitoring\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l5 level1 lfo57; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse the MC811 MAX’s display for ongoing supervision of water quality during:\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eRinse cycles\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eIngredient blending\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eBoiler feed or steam generation\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt;\" class=\"MsoNormal\"\u003eYeast propagation or fermentation control\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l5 level1 lfo57; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eSet visual alerts or connect to a control panel to signal when values are out of specification.\u003c\/p\u003e\n\u003col type=\"1\" start=\"5\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l61 level1 lfo53; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eResponding to Variations\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l55 level1 lfo56; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003epH out of range?\u003c\/b\u003e Adjust using food-safe acid\/base agents or check water source contamination.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l55 level1 lfo56; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eHigh EC?\u003c\/b\u003e Indicates mineral-heavy water – filters, RO system performance, or switch water source.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l55 level1 lfo56; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eTemperature issues?\u003c\/b\u003e Investigate heat exchanger performance or steam line pressures.\u003c\/p\u003e\n\u003col type=\"1\" start=\"6\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l61 level1 lfo53; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eMaintenance\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l53 level1 lfo55; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eClean probes regularly using food-safe cleaning agents or Milwaukee’s \u003cb\u003eprobe cleaning solution\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l53 level1 lfo55; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eStore pH probe in \u003cb\u003estorage solution\u003c\/b\u003e between uses or shifts.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l53 level1 lfo55; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eInspect for fouling, particularly from proteins, oils, or organic residues.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l53 level1 lfo55; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eDocument calibration and cleaning as part of your \u003cb\u003equality assurance SOP\u003c\/b\u003e.\u003c\/p\u003e\n\u003col type=\"1\" start=\"7\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l61 level1 lfo53; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eAudit-Ready Recordkeeping\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l24 level1 lfo54; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eLog daily pH, EC, and temperature values along with calibration checks.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l24 level1 lfo54; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse data in HACCP audits, ISO certifications, or traceability reports.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l24 level1 lfo54; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eEnsure records align with your food safety management system and critical control point protocols.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe MC811 MAX is more than a monitor – it’s a \u003cb\u003equality gatekeeper\u003c\/b\u003e in your production chain. Its dependable, real-time readings help you deliver consistent, compliant, and high-quality food and beverages every single time.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e  \u003cbr\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eIndustrial \u0026amp; Environmental Monitoring\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn both industrial and environmental contexts, \u003cb\u003ewater chemistry plays a crucial role in operational efficiency, compliance, and ecological safety\u003c\/b\u003e. Whether you're managing a plating line, monitoring boiler feed water, or analyzing runoff from agricultural zones, even minor fluctuations in \u003cb\u003epH\u003c\/b\u003e, \u003cb\u003eelectrical conductivity (EC)\u003c\/b\u003e, or \u003cb\u003etemperature\u003c\/b\u003e can have significant consequences.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC811 MAX\u003c\/b\u003e delivers real-time monitoring of these three critical parameters, helping operators \u003cb\u003erespond quickly to deviations\u003c\/b\u003e, maintain regulatory compliance, and \u003cb\u003eoptimize processes or protection efforts\u003c\/b\u003e.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e \u003cb\u003eIndustrial Applications\u003c\/b\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eIndustries that use or discharge large volumes of water – such as \u003cb\u003emetal finishing, power generation, textile processing, chemical manufacturing\u003c\/b\u003e, and \u003cb\u003ecooling tower management\u003c\/b\u003e—depend on tight control of water chemistry. Here's why:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l68 level1 lfo61; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003epH imbalances\u003c\/b\u003e can lead to equipment corrosion, poor plating adhesion, scaling, or reduced chemical reactivity.\u003c\/li\u003e\n\u003cli style=\"mso-list: l68 level1 lfo61; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eEC levels\u003c\/b\u003e reflect the ionic concentration in wate – key for evaluating process water purity, chemical dosing accuracy, and system fouling risks.\u003c\/li\u003e\n\u003cli style=\"mso-list: l68 level1 lfo61; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eTemperature\u003c\/b\u003e affects reaction kinetics, solubility, and microbial growth – impacting safety and efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWith continuous data from the MC811 MAX, facility managers can prevent damage to heat exchangers and piping, monitor cooling systems for scaling or biofouling risks, control pH in plating baths or chemical reactors, track wastewater treatment parameters before discharge, maintain safe and stable process conditions.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e \u003cb\u003eEnvironmental Applications\u003c\/b\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003eFor environmental professionals, \u003cb\u003ereal-time monitoring\u003c\/b\u003e is a powerful tool in tracking and protecting water quality in natural or managed ecosystems. The MC811 MAX can be used at \u003cb\u003eoutflow points, streams, reservoirs, or constructed wetlands\u003c\/b\u003e to monitor:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l30 level1 lfo62; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003epH drift\u003c\/b\u003e from acid rain, industrial discharge, or agricultural runoff\u003c\/li\u003e\n\u003cli style=\"mso-list: l30 level1 lfo62; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eEC increases\u003c\/b\u003e indicating nutrient loading or contamination from fertilizers, salts, or urban runoff\u003c\/li\u003e\n\u003cli style=\"mso-list: l30 level1 lfo62; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eTemperature shifts\u003c\/b\u003e that affect aquatic life or signal thermal pollution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eUsed by NGOs, researchers, or municipalities, the MC811 MAX supports \u003cb\u003ecompliance with water quality standards, early detection of contamination events, baseline establishment for long-term studies, impact assessment of nearby industrial or agricultural activity.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e \u003cb\u003eHow to Use the MC811 MAX in Industrial \u0026amp; Environmental Settings\u003c\/b\u003e\n\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1. Installation \u0026amp; Power Supply\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l44 level1 lfo63; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMount the MC811 MAX in a central location where readings are easily visible to operators.\u003c\/li\u003e\n\u003cli style=\"mso-list: l44 level1 lfo63; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eIn industrial settings, install it \u003cb\u003enear a water sampling point\u003c\/b\u003e, flow cell, or inline process loop.\u003c\/li\u003e\n\u003cli style=\"mso-list: l44 level1 lfo63; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eFor field monitoring, use a weather-resistant enclosure with appropriate electrical protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2. Probe Positioning\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l56 level1 lfo64; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eInsert the \u003cb\u003epH\u003c\/b\u003e and \u003cb\u003eEC\/temperature probes\u003c\/b\u003e into a bypass line, sample tank, or direct immersion point depending on application.\u003c\/li\u003e\n\u003cli style=\"mso-list: l56 level1 lfo64; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eIn environmental settings, place probes in \u003cb\u003ea sampling well, stream inlet, or outflow basin\u003c\/b\u003e – secured in place and protected from debris.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3. Calibration\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l16 level1 lfo65; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate the pH probe\u003c\/b\u003e using fresh buffer solutions at pH 7.01 and 4.01 (or 10.01, depending on your expected range).\u003c\/li\u003e\n\u003cli style=\"mso-list: l16 level1 lfo65; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eCalibrate the EC probe\u003c\/b\u003e using a known conductivity standard (e.g., 1413 µS\/cm or 12880 µS\/cm).\u003c\/li\u003e\n\u003cli style=\"mso-list: l16 level1 lfo65; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePerform calibration:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eDaily or weekly\u003c\/b\u003e in industrial process environments\u003c\/p\u003e\n\u003cp style=\"margin-left: 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eBefore each deployment or sampling session\u003c\/b\u003e in environmental monitoring\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e4. Real-Time Monitoring\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l9 level1 lfo66; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMonitor continuously to:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 36.0pt;\" class=\"MsoNormal\"\u003eDetect unusual pH or EC shifts that could indicate contamination, chemical spills, or process errors\u003c\/p\u003e\n\u003cp style=\"margin-left: 36.0pt;\" class=\"MsoNormal\"\u003eAdjust chemical dosing in real-time to stabilize water quality\u003c\/p\u003e\n\u003cp style=\"margin-left: 36.0pt;\" class=\"MsoNormal\"\u003ePrevent system damage or regulatory violations\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e5. Data Interpretation\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l69 level1 lfo67; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eSudden pH drops\u003c\/b\u003e may signal acid leaks, microbial growth, or chemical reactions.\u003c\/li\u003e\n\u003cli style=\"mso-list: l69 level1 lfo67; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eEC spikes\u003c\/b\u003e may reflect increased ion concentrations – useful for tracking pollutant loading, dosing accuracy, or membrane performance.\u003c\/li\u003e\n\u003cli style=\"mso-list: l69 level1 lfo67; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cb\u003eTemperature anomalies\u003c\/b\u003e could indicate heat exchanger failures, thermal discharge, or seasonal shifts in natural water bodies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6. Maintenance\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l48 level1 lfo68; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eRinse probes after each use or sampling session to remove solids, oil, or scale.\u003c\/li\u003e\n\u003cli style=\"mso-list: l48 level1 lfo68; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eUse probe cleaning solutions when buildup is visible or accuracy drifts.\u003c\/li\u003e\n\u003cli style=\"mso-list: l48 level1 lfo68; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eStore pH probe in storage solution – never let it dry.\u003c\/li\u003e\n\u003cli style=\"mso-list: l48 level1 lfo68; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePeriodically inspect cables and probe connectors for damage, especially in rugged or outdoor conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e7. Reporting \u0026amp; Compliance\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l49 level1 lfo69; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eLog data regularly – either manually or by connecting the monitor to a data acquisition system.\u003c\/li\u003e\n\u003cli style=\"mso-list: l49 level1 lfo69; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eUse readings as part of environmental impact assessments, safety documentation, or compliance reports.\u003c\/li\u003e\n\u003cli style=\"mso-list: l49 level1 lfo69; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eGenerate alerts when values exceed predefined thresholds (if connected to SCADA or alarm systems).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you're managing an industrial water loop or monitoring the health of a natural ecosystem, the Milwaukee MC811 MAX offers \u003cb\u003erobust, dependable monitoring\u003c\/b\u003e for a wide range of demanding applications. It empowers professionals to make data-driven decisions, protect assets, and safeguard the environment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e  \u003cbr\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eWater Treatment \u0026amp; Purification\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eIn both municipal and industrial water treatment systems, maintaining water quality isn’t just important—it’s \u003cb\u003eregulated and mission-critical\u003c\/b\u003e. Whether you’re purifying drinking water, treating wastewater, or operating a filtration system for industrial reuse, \u003cb\u003eprecise and continuous monitoring\u003c\/b\u003e of parameters like \u003cb\u003epH\u003c\/b\u003e, \u003cb\u003eelectrical conductivity (EC)\u003c\/b\u003e, and \u003cb\u003etemperature\u003c\/b\u003e is essential for efficiency, safety, and compliance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003epH\u003c\/b\u003e plays a pivotal role in nearly every stage of water treatment. It affects \u003cb\u003echemical dosing\u003c\/b\u003e efficiency (e.g., chlorine, coagulants, lime), \u003cb\u003ebiological treatment performance\u003c\/b\u003e in systems like activated sludge, \u003cb\u003ecorrosion control\u003c\/b\u003e in distribution systems, \u003cb\u003eprecipitation and removal\u003c\/b\u003e of metals or phosphates, \u003cb\u003eelectrical conductivity (EC)\u003c\/b\u003e is used as a quick indicator of \u003cb\u003etotal dissolved solids (TDS)\u003c\/b\u003e, salinity, or the ionic content of the water.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eChanges in EC may indicate \u003cb\u003einflows of pollutants or saltwater intrusion, breakthrough in filtration systems, effectiveness of reverse osmosis, ion exchange, or deionization processes\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eTemperature\u003c\/b\u003e influences the solubility of gases, reaction rates, and biological activity, especially in aerobic or anaerobic treatment systems. Monitoring temperature ensures consistent process performance and helps prevent equipment issues.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eMilwaukee MC811 MAX\u003c\/b\u003e gives plant operators and water quality managers a \u003cb\u003ereliable, real-time window\u003c\/b\u003e into these essential metrics. Its continuous monitoring capability allows:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l6 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eFaster reaction to anomalies or system failures\u003c\/li\u003e\n\u003cli style=\"mso-list: l6 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eImproved chemical dosing accuracy\u003c\/li\u003e\n\u003cli style=\"mso-list: l6 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eVerification of treatment effectiveness\u003c\/li\u003e\n\u003cli style=\"mso-list: l6 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDocumentation for regulatory compliance\u003c\/li\u003e\n\u003cli style=\"mso-list: l6 level1 lfo16; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eReduced manual sampling and labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eFrom small-scale purification units to large-scale municipal plants, the MC811 MAX ensures stable operation and supports both preventive and corrective actions before minor deviations escalate into costly issues.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003eHow to Use the MC811 MAX in Water Treatment \u0026amp; Purification Systems\u003c\/b\u003e\u003c\/h3\u003e\n\u003col type=\"1\" start=\"1\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l8 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eInstallation\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l67 level1 lfo23; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMount the MC811 MAX unit in a dry, protected location near your water system’s sampling or treatment area.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l67 level1 lfo23; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eEnsure good visibility for reading display values and easy access for maintenance.\u003c\/p\u003e\n\u003col type=\"1\" start=\"2\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l8 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eProbe Placement\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l34 level1 lfo22; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eSubmerge the \u003cb\u003epH\u003c\/b\u003e and \u003cb\u003eEC\/temperature\u003c\/b\u003e probes in the sample flow or treatment basin.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l34 level1 lfo22; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eFor best results, install the probes in \u003cb\u003eflow-through cells\u003c\/b\u003e, \u003cb\u003eside-stream lines\u003c\/b\u003e, or \u003cb\u003ededicated monitoring points\u003c\/b\u003e where consistent and representative water samples are available.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l34 level1 lfo22; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse appropriate fittings or holders to protect the probes from physical damage and fouling.\u003c\/p\u003e\n\u003col type=\"1\" start=\"3\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l8 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eCalibration\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l66 level1 lfo21; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ePerform a \u003cb\u003e2-point calibration\u003c\/b\u003e for pH and \u003cb\u003e1-point calibration\u003c\/b\u003e for EC using Milwaukee’s certified calibration solutions.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l66 level1 lfo21; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCalibrate prior to first use and routinely (weekly to monthly depending on system complexity and importance).\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l66 level1 lfo21; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eKeep detailed calibration logs to support quality assurance or regulatory inspections.\u003c\/p\u003e\n\u003col type=\"1\" start=\"4\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l8 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eMonitoring\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l2 level1 lfo20; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eThe MC811 MAX displays real-time values for all three parameters on its bright, easy-to-read interface.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l2 level1 lfo20; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eCompare readings against established control limits or quality targets.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l2 level1 lfo20; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse the monitor in tandem with SCADA systems or data loggers, if applicable, by manually recording or automating the values.\u003c\/p\u003e\n\u003col type=\"1\" start=\"5\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l8 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eResponding to Data\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l4 level1 lfo19; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eWhen pH drifts from the target range, assess chemical dosing systems or check for system upsets.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l4 level1 lfo19; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eIf EC increases sharply, investigate possible contamination, chemical overuse, or membrane\/filter breakthrough.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l4 level1 lfo19; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eMonitor temperature for consistency, especially in biologically active treatment processes.\u003c\/p\u003e\n\u003col type=\"1\" start=\"6\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l8 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eMaintenance\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l32 level1 lfo18; tab-stops: list 53.4pt;\" class=\"MsoListParagraphCxSpFirst\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eClean probes regularly to prevent fouling from biological growth, scaling, or sludge.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l32 level1 lfo18; tab-stops: list 53.4pt;\" class=\"MsoListParagraphCxSpMiddle\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse \u003cb\u003epH storage solution\u003c\/b\u003e to preserve electrode longevity when not in use.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; mso-add-space: auto; text-indent: -18.0pt; mso-list: l32 level1 lfo18; tab-stops: list 53.4pt;\" class=\"MsoListParagraphCxSpLast\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eReplace probes as necessary when calibration becomes unstable or measurement drift occurs frequently.\u003c\/p\u003e\n\u003col type=\"1\" start=\"7\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l8 level1 lfo17; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cb\u003eDocumentation \u0026amp; Compliance\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l33 level1 lfo70; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eUse MC811 MAX readings as part of your standard operating procedures (SOPs) and recordkeeping.\u003c\/p\u003e\n\u003cp style=\"margin-left: 53.4pt; text-indent: -18.0pt; mso-list: l33 level1 lfo70; tab-stops: list 53.4pt;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eRegular logs of pH and EC values can support inspections, audits, or certifications (e.g., ISO, local environmental authorities).\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhether you’re optimizing chemical usage in a filtration system, ensuring your effluent meets discharge standards, or simply maintaining the performance of a small purification unit, the MC811 MAX offers a dependable, professional-grade monitoring solution – 24\/7.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56193396343157,"sku":"MC811","price":305.31,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/mc811_4_1920x1920_f131583a-1023-4326-8989-7d9dfb0a78ca.jpg?v=1761815413"},{"product_id":"milwaukee-mc810-max-ph-tds-temp-monitor","title":"Milwaukee MC810 MAX pH\/TDS\/Temp Monitor","description":"\u003cdiv class=\"offcanvas-content-container\"\u003e\n\u003cdiv class=\"product-detail-description tab-pane-container\"\u003e\n\u003cdiv class=\"product-detail-description-text\" itemprop=\"description\"\u003e\n\u003ch2\u003e\u003cstrong\u003eAccurate. Simple. Reliable. 24\/7 pH\/TDS\/Temp Monitoring.\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eWhy Guard when you can Monitor! The Milwaukee MC810 MAX pH\/TDS\/Temp Monitor lets you monitor your pH\/TDS\/Temp levels 24\/7 automatically.\u003c\/p\u003e\n\u003ch3\u003eComments From Field Testing\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\"I run this unit 24\/7 and have not had any problems for the past two months. I can monitor 24\/7, point a camera on it and connect to my phone.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\"Easy to calibrate.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\"Using this now, far less expensive than what my friends paid ... I recommend this to any serious grower.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSummary\u003c\/h3\u003e\n\u003cp\u003eThe MC810 MAX Monitor automatically monitors and displays pH\/TDS\/Temp levels.  Just calibrate the parameters and let the Milwaukee MAX Monitor do the rest.\u003c\/p\u003e\n\u003cp\u003eThe Milwaukee MC810 MAX pH\/TDS\/Temp Monitor is preferred by people looking to know 24\/7 what their pH and nutrient levels are on an ongoing basis. Common uses are nutrient tanks, Hydroponics and aquariums.\u003c\/p\u003e\n\u003cp\u003eThe Milwaukee MAX pH\/TDS\/Temp Monitor offers:\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Milwaukee MAX Monitor offers an accuracy to \u003cspan class=\"single-product-meta-item-value\"\u003e± \u003c\/span\u003e0.2 pH with two point manual calibration, TDS accuracy of \u003cspan\u003e±\u003c\/span\u003e2% Full Scale and \u003cspan\u003e±\u003c\/span\u003e0.5 °F (0.3C) temperature accuracy.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAutomation\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eJust calibrate the parameters and begin to monitor 24\/7!\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eDesign features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFast easy to read current results with 3 large digital BACKLIT LCD readouts.\u003c\/li\u003e\n\u003cli\u003eAccurate to \u003cspan\u003e±\u003c\/span\u003e0.2 pH (0.0 pH to 12.0 pH).\u003c\/li\u003e\n\u003cli\u003eAccurate  \u003cspan\u003e±2% Full Scale TDS. \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExternal Switch atop the unit converts EC conductivity to TDS (ppm) using 0.5 or 0.7 conversion factor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eSimple two-point pH calibration and one point TDS, for increased accuracy with manual trimmers for easy adjustment.\u003c\/li\u003e\n\u003cli\u003eGel-filled, double junction MA911B\/2 (included) lab grade pH electrode for low maintenance and high performance.\u003c\/li\u003e\n\u003cli\u003e6.5 feet probe cables for extra flexibility when testing.\u003c\/li\u003e\n\u003cli\u003e12 VDC power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e Use and Care \u003c\/h3\u003e\n\u003cp\u003epH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSensing bulb\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eReference junction\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.\u003c\/p\u003e\n\u003cp\u003eYou can extend the life of your pH electrode in the following ways.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.\u003c\/p\u003e\n\u003cp\u003eStoring in pH probe storage solution or pH calibration buffers will help address both these issues. Do not store in tap water and DI water. This will damage the sensitivity of the probe.\u003c\/p\u003e\n\u003cp\u003eThe best way to store the probe is with the probe's cap filled with storage solution or calibiration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCleaning\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eResidue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your PRO pH controller accurate. \u003cspan style=\"font-weight: 400;\"\u003eAlso, calibrate after cleaning or a long period of storage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"specification-tab-pane\" role=\"tabpanel\" aria-labelledby=\"specification-tab\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003epH Range: 0.0 - 12.0 pH \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003epH Resolution: 0.1 pH \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003epH Accuracy: ±0.2 pH \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003epH Calibration: Manual, 2 points (trimmer) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003epH Probe: MA911B\/2 (included) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTDS Range: 0 - 1990 ppm \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTDS Resolution: 10 ppm \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTDS Accuracy: ±2% Full Scale \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTDS Calibration: manual, 1 point (trimmer) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTDS Probe: MA811 (fixed, Included) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTemperature Range: 14.0 to 140.0°F (-10.0 to 60.0°C) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTemperature Resolution: 0.1°F \/ 0.1°C \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTemperature Accuracy: ±0.5°F \/ ±0.3°C \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTemperature Calibration: Factory Calibrated Temperature Compensation: Automatic, 41 to 122°F (5 to 50°C), (TDS \/ EC Readings Only) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTemperature Probe: Stainless Steel (fixed, included) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003ePower Supply: 12 VDC adapter (included) Dimensions: 6.3\" x 4.3\" x 1.4\" (160 mm x 110 mm x 35 mm )\u003c\/div\u003e\n\u003cdiv\u003eMounting kit: (Included) \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eWeight: 1.2 lbs. (560 g)\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56193431798133,"sku":"MC810","price":305.31,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/mc810_01_1920x1920_b79bcb46-c36a-4b96-a3e9-7e7191499c46.jpg?v=1761815774"},{"product_id":"milwaukee-mc740-pro-conductivity-ec-controller-and-pump-kit","title":"Milwaukee MC740 PRO Conductivity (EC) Controller and Pump Kit","description":"\u003ch1 class=\"product-detail-name\" itemprop=\"name\"\u003eMilwaukee MC740 PRO Conductivity (EC) Controller and Pump Kit\u003c\/h1\u003e\n\u003cp\u003eThe Milwaukee MC740 PRO Conductivity (EC) controller and pump lets you measure and adjust EC levels automatically.\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCONTROL THE EC AND FERTILIZER DOSAGE IN YOUR TANK AUTOMATICALLY\u003c\/h2\u003e\n\u003cdiv\u003eThe MC740 kit includes the MC311 EC controller and the MP810 dosing pump to automatically monitor and fine-tune EC levels. Just set your EC parameters and let the Milwaukee EC Controller and pump do the rest.\u003c\/div\u003e\n\u003cdiv\u003eThe Milwaukee PRO EC controller kit is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks.\u003c\/div\u003e\n\u003cdiv\u003eThe Milwaukee PRO EC controller and pump offers:\u003c\/div\u003e\n\u003ch4\u003eACCURACY\u003c\/h4\u003e\n\u003cdiv\u003eThe Milwaukee PRO EC controller offers an accuracy to ±2% full scale.\u003c\/div\u003e\n\u003ch4\u003eAUTOMATION\u003c\/h4\u003e\n\u003cdiv\u003eThe controller provides a control range of 0.0 to 10.0 mS\/cm with alarms that activate when readings are higher or lower than set point.\u003c\/div\u003e\n\u003ch4\u003eCOMPATIBLE DOSING PUMP\u003c\/h4\u003e\n\u003cdiv\u003eThe Milwaukee MP810 dosing pump (designed specifically for use with the MC311) is included in the kit.\u003c\/div\u003e\n\u003ch4\u003eEASY INSTALLATION\u003c\/h4\u003e\n\u003cdiv\u003eThe MC740 EC controller and pump kit comes with a complete mounting kit including a probe holder.\u003c\/div\u003e\n\u003ch2\u003eDESIGN FEATURES\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eFast easy to read current results with large digital LCD readout and visual LED alarm\u003c\/li\u003e\n\u003cli\u003eAccurate to ±2% full scale (0.0 pH to 10.0 mS\/cm) with the user selectable high\/low set points\u003c\/li\u003e\n\u003cli\u003eSimple one-point calibration for increased accuracy with manual trimmers for easy adjustment\u003c\/li\u003e\n\u003cli\u003eMA812\/2 hardwired EC probe included\u003c\/li\u003e\n\u003cli\u003e6.5 feet probe cables for extra flexibility when testing\u003c\/li\u003e\n\u003cli\u003e12 VDC power supply\u003c\/li\u003e\n\u003cli\u003ePump provides a maximum pressure of 1.5 bar or more than 50 feet of head pressure with a 0.16 GPM dosing flow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"specification-tab-pane\" role=\"tabpanel\" aria-labelledby=\"specification-tab\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eMC311 SPECIFICATIONS\u003c\/h3\u003e\n\u003cdiv\u003eRange: 0.0 - 10.0 mS\/cm\u003c\/div\u003e\n\u003cdiv\u003eResolution: 0.1 mS\/cm\u003c\/div\u003e\n\u003cdiv\u003eAccuracy: ±2% F.S.\u003c\/div\u003e\n\u003cdiv\u003eCalibration: Manual, 1-point\u003c\/div\u003e\n\u003cdiv\u003eSet point: 0.8 to 2.8 mS\/cm\u003c\/div\u003e\n\u003cdiv\u003eAlarm: Active when reading is higher or lower than set point\u003c\/div\u003e\n\u003cdiv\u003eTemperature Compensation: Automatic, from 0 to 50°C\u003c\/div\u003e\n\u003cdiv\u003eEC electrode: MA812\/2 (included)\u003c\/div\u003e\n\u003cdiv\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/div\u003e\n\u003cdiv\u003ePower Supply: 12 VDC adapter (included)\u003c\/div\u003e\n\u003cdiv\u003ePower Drivers: 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz\u003c\/div\u003e\n\u003cdiv\u003eMounting kit (Included)\u003c\/div\u003e\n\u003cdiv\u003eDimensions: 5.9 x 3.2 x 1.35 inches\u003c\/div\u003e\n\u003cdiv\u003eWeight: 6.3 ounces (meter only)\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eMP810 SPECIFICATIONS\u003c\/h3\u003e\n\u003cdiv\u003eMax. Flow: 0.6 L\/h\u003c\/div\u003e\n\u003cdiv\u003eMax. Pressure: 1.5 bar\u003c\/div\u003e\n\u003cdiv\u003eSqueeze tubing: Santoprene\u003c\/div\u003e\n\u003cdiv\u003eExt. Tube connection: 6 mm\u003c\/div\u003e\n\u003cdiv\u003ePower supply: 240 VAC, 50-60 Hz or 110 VAC, 60 Hz\u003c\/div\u003e\n\u003cdiv\u003ePower consumption: 0.42 W\u003c\/div\u003e\n\u003cdiv\u003eDimensions: 100 x 106 x 108 mm\u003c\/div\u003e\n\u003cdiv\u003eWeight: 17.6 oz.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56193628635509,"sku":"MC740KIT","price":410.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/MC311_includes-EUROcopy_1920x1920_b478f28e-c157-4797-ae1e-03f8f399ae6d.jpg?v=1761819179"},{"product_id":"milwaukee-mc410-pro-total-dissolved-solids-tds-monitor","title":"Milwaukee MC410 PRO Total Dissolved solids (TDS) Monitor","description":"\u003ch1 class=\"product-detail-name\" itemprop=\"name\"\u003eMilwaukee MC410 PRO Total Dissolved solids (TDS) Monitor\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003eACCURATE. SIMPLE. RELIABLE. 24\/7 TDS MONITORING.\u003c\/h1\u003e\n\u003cdiv\u003eThe Milwaukee MC410 PRO Total Dissolved Solids (TDS) monitor lets you measure TDS levels automatically and alerts with an alarm when out of the set point range.\u003c\/div\u003e\n\u003ch3\u003eSUMMARY\u003c\/h3\u003e\n\u003cdiv\u003eThe MC410 automatically monitors your TDS levels. Just set your TDS parameters and let the Milwaukee TDS monitor do the rest.\u003c\/div\u003e\n\u003cdiv\u003eThe Milwaukee PRO TDS monitor is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks, aquariums, aquaculture \u0026amp; coral, pools and water conditioning.\u003c\/div\u003e\n\u003cdiv\u003eThe Milwaukee PRO TDS monitor offers:\u003c\/div\u003e\n\u003ch4\u003eACCURACY\u003c\/h4\u003e\n\u003cdiv\u003eThe Milwaukee PRO TDS monitor offers an accuracy to ±2% full scale.\u003c\/div\u003e\n\u003ch4\u003eAUTOMATION\u003c\/h4\u003e\n\u003cdiv\u003eThe Milwaukee PRO TDS monitor has a range of 0 to 1990 (ppm) with visual alarms that activate when readings are higher or lower than set point.\u003c\/div\u003e\n\u003ch3\u003eDESIGN FEATURES\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eFast easy to read current results with large digital LCD readout and visual LED alarm.\u003c\/li\u003e\n\u003cli\u003eAccurate to ±2% full scale (0 to 1990 ppm) with the user selectable high\/low set points.\u003c\/li\u003e\n\u003cli\u003eSimple one-point calibration for increased accuracy with manual trimmers for easy adjustment.\u003c\/li\u003e\n\u003cli\u003eAutomatic temperture compensation.\u003c\/li\u003e\n\u003cli\u003eMA812\/2 hardwired EC probe included.\u003c\/li\u003e\n\u003cli\u003e6.5 feet (2 meter) probe cables for extra flexibility when testing.\u003c\/li\u003e\n\u003cli\u003e12 VDC power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"tab-pane fade show active\" id=\"specification-tab-pane\" role=\"tabpanel\" aria-labelledby=\"specification-tab\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eRange: 0 - 1990 (ppm) mg\/L\u003c\/div\u003e\n\u003cdiv\u003eResolution: 10 (ppm)\u003c\/div\u003e\n\u003cdiv\u003eAccuracy: ±2% F.S.\u003c\/div\u003e\n\u003cdiv\u003eConversion factor: 0.7\u003c\/div\u003e\n\u003cdiv\u003eCalibration: Manual, 1-point\u003c\/div\u003e\n\u003cdiv\u003eSet point: 100 to 1900 (ppm)\u003c\/div\u003e\n\u003cdiv\u003eAlarm: Active when reading is higher or lower than set point\u003c\/div\u003e\n\u003cdiv\u003eTemperature Compensation: Automatic, from 0 to 50°C | 32 to 122°F\u003c\/div\u003e\n\u003cdiv\u003eEC electrode: MA812\/2 (included)\u003c\/div\u003e\n\u003cdiv\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/div\u003e\n\u003cdiv\u003ePower Supply: 12 VDC adapter (included)\u003c\/div\u003e\n\u003cdiv\u003eMounting kit (Included)\u003c\/div\u003e\n\u003cdiv\u003eDimensions: 5.9 x 3.2 x 1.35 inches (148.5 x 82.5 x 32 mm)\u003c\/div\u003e\n\u003cdiv\u003eWeight: 6.3 ounces (180 g) (meter only)\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":56255088329077,"sku":"MC410","price":138.06,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/MC410_includescopy_1920x1920_5b8f9c13-afc8-47f0-ac00-e2bd250d458d.jpg?v=1762424849"}],"url":"https:\/\/testallwater.co.uk\/collections\/controllers-monitors.oembed","provider":"Test All Water","version":"1.0","type":"link"}