{"title":"Chemical and Laboratory Analysis","description":null,"products":[{"product_id":"hanna-instruments-4102-bromide-combination-ise-electrode","title":"Hanna Instruments-4102 Bromide Combination ISE Electrode","description":"The Hanna Instruments-4102 is ideal for a variety of applications in the pharmaceutical industry, laboratories, drinking water and wastewater treatment, food and beverage production, and in printing processes.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4102 bromide ion selective electrode is a complete potentiometric cell that contains a silver\/silver chloride (Ag\/AgCl) reference housed within a PEI plastic body with a potassium nitrate electrolyte. The internal elements are isolated from the sample by a compressed silver bromide sensing membrane.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna's solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFor the Hanna Instruments-4102 to measure bromide accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free bromide ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The Hanna Instruments-4102 bromide solid state ISE can measure from 1ÂµM (0.08 mg\/L) to 1M (79,910 mg\/L).\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354372976791,"sku":"HI-4102","price":940.41,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-4102_bromide_combination_ise_electrode_153bdf8a-36d2-4706-8fa5-3085e99a1acd.jpg?v=1624278755"},{"product_id":"hanna-instruments-83306-02-multi-parameter-environmental-analysis-photometer-with-ph-meter","title":"Hanna Instruments-83306-02 Multi-parameter Environmental Analysis Photometer with pH meter","description":"One meter can be used for both photometric and pH measurements. Hanna Instruments-83306 is a compact, multi-parameter photometer for use in the environmental lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 23 different programmed methods measuring 16 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. Environmental parameters include nitrate, phosphorous and dissolved oxygen.\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHanna Instruments-83306-02 Environmental Analysis Photometer with pH digital input \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe photometer features an innovative optical system that uses LEDs, narrow band interference filters, a focusing lens, and a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source which ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83306 was developed to measure the most common parameters in environmental water quality monitoring. Nutrients such as nitrates and phosphates are key indicators of nutrient pollution from agricultural sources and are considered dangerous to environmental waters. Too few nutrients and waters will be unable to sustain healthy ecosystems; too many nutrients and algal blooms can form, which can be detrimental to water quality and aquatic health. Dissolved oxygen is an essential to performing biological processes for many forms of aquatic life, such as fish, plants and microorganisms.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83306 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the four wavelengths of light (420 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability, the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eKey features: \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHigh Efficiency LED Light Source\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHigh Quality Narrow Band Interference Filters \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eReference Detector for a Stable Light Source \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eLarge Cuvette Size \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eFocusing Lens for Greater Light Yield \u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354373075095,"sku":"HI-83306-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83306-02_multi-parameter_environmental_analysis_photometer_with_ph_meter_357082fd-4ba0-4d5e-8514-04ae70880382.jpg?v=1624278761"},{"product_id":"hanna-instruments-801-02-iris-spectrophotometer","title":"Hanna Instruments-801-02 Iris Spectrophotometer","description":"The Hanna Instruments-801 iris is a sleek and intuitive spectrophotometer that allows for measurement of all wavelengths of visible light.\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior design for superior results\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm.\u003c\/p\u003e\n\u003cp\u003eWith the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy. No need for measurement conversions Whether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-801 iris is a sleek and intuitive spectrophotometer that allows for measurement of all wavelengths of visible light.\u003c\/p\u003e\n\u003cp\u003eCustomise your methods, take a wide range of measurements, and feel confident in your testing accuracy with iris.\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eiris features precise wavelength selection between 340 nm to 900 nm for complete method compliance and accuracy that is necessary in industries like professional laboratories, water treatment facilities, wineries, and more.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eResults are consistent and accurate regardless of throughput with the high quality and uniquely designed optics system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCustomisation options include multiple cuvette shapes and sizes, custom calibration curves, and methods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354373271703,"sku":"HI-801-02","price":3340.01,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-801-02_iris_spectrophotometer_ae9cb400-8683-4282-b36b-666f4c257144.jpg?v=1624278769"},{"product_id":"hanna-instruments-83303-02-aquaculture-multi-parameter-photometer-with-ph-meter","title":"Hanna Instruments-83303-02 AquaCulture Multi-parameter Photometer with pH Meter","description":"One meter can be used for both photometric and pH measurements. The meter has 20 different programmed methods measuring 12 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003cbr\u003e\u003ch3\u003eHanna Instruments-83303 Aquaculture Photometer with pH meter\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable benchtop space, the Hanna Instruments-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input. Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMade with the aquaculture industry in mind, the Hanna Instruments-83303 is a comprehensive solution to maintaining optimal chemical and environmental conditions, preventing disease and increasing production.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 measures vital parameters such as Alkalinity, Calcium, Nitrite, and Phosphate. Alkalinity plays a part in a dynamic relationship with pH and CO2 concentrations, high alkalinity water lowers fluctuations in pH. The buffering capacity acts to store extra CO2 essential for photosynthesis in the ponds to produce oxygen. Maintaining calcium at certain levels is vital to proper fish growth and development. Excessive nitrite can be toxic to fish. When nitrite interacts with Haemoglobin, the iron becomes oxidised and the blood cell can no longer carry oxygen. Phosphate is essential to plant growth; too much phosphate in an aquaculture system can contribute to algal blooms decreasing dissolved oxygen vital for a successful ecosystem.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83303 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375336087,"sku":"HI-83303-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_2_82e0c6fb-4e30-4e5b-9e18-bcb58add9261.jpg?v=1624278828"},{"product_id":"hanna-instruments-83300-02-multi-parameter-benchtop-photometer-ph-meter","title":"Hanna Instruments-83300-02 Multi-parameter Benchtop Photometer \u0026 pH meter","description":"One meter can be used for both photometric and pH measurements. The meter has 60 different programmed methods measuring 37 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83300 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003cbr\u003e\u003ch3\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-83300 is a compact, multi-parameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFrom Aluminium to Zinc, the Hanna Instruments-83300 benchtop photometer measures 37 water quality parameters using 60 different methods. The photometer features an innovative optical system that uses LEDs, narrow band interference filters, and a focusing lens. It also has a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83300 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375467159,"sku":"HI-83300-02","price":1489.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_3_dc75fef9-64f1-4563-8b90-e8a5f746505a.jpg?v=1624278832"},{"product_id":"hanna-instruments-1053b-ph-electrode-for-use-with-semi-solids","title":"Hanna Instruments-1053B pH Electrode for use with Semi-Solids","description":"The Hanna Instruments-1053B is a glass bodied refillable single junction combination pH electrode with a spear tip measuring tip and suitable for pH measurement of fats and creams, soil samples, semi solid product, low conductivity samples and emulsions.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-1053B is a glass bodied refillable single junction combination pH electrode with a spear tip.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eIdeal for\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFats or creams\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSoil samples\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSemi-solid products\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLow conductivity samples\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eEmulsions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eSupplied fitted with\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBNC connector\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e1m cable\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375663767,"sku":"HI-1053B","price":230.19,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-1053b_ph_electrode_for_use_with_semi-solids_259e5deb-41f9-4fa3-b617-d35cc8af8ebd.jpg?v=1624278834"},{"product_id":"hanna-instruments-96802-refractometer-for-fructose-0-to-85-scale","title":"Hanna Instruments-96802 Refractometer for Fructose 0 to 85% scale","description":"The Hanna Instruments-96802 measures the refractive index to determine the % fructose in aqueous solutions. The refractive index of the sample is converted to % mass (%w\/w) concentration units.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-98602 is used across the food industry for measuring the % fructose in foods.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eQuick and easy to use it is ideal for analysing the sugar content in a wide range of food products including fruit, energy drinks, puddings, tofu, jams, honey, soups and sauces.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003ePriced inexpensively does not mean a compromise on accuracy, the Hanna refractometer offers all the benefits of high precision digital technology at the same price as a mechanical model.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-96802 measures the refractive index to determine the % fructose in aqueous solutions. The refractive index of the sample is then converted to % by weight concentration units.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eProduct uses\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFruit growers and importers\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eFruit juice \u0026amp; drink manufacturers\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eProduction of jams, preserves \u0026amp; sauces\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eWhite water resistant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eEasy clean sample well\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eZero using pure water\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery operated with auto shut-off\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eMain benefits\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003e1.5 second measurement time\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDirect readout in % Brix and °C\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eNo calibration solutions required\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLarge clear LCD display\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354376188055,"sku":"HI-96802","price":323.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-96802_refractometer_for_fructose_0_to_85_scale_d9c1cb0c-8843-46d4-94cd-e7d4c40eb864.jpg?v=1624278856"},{"product_id":"hanna-instruments-83325-02-multi-parameter-photometer-with-ph-meter-for-plant-nutrient-analysis","title":"Hanna Instruments-83325-02 Multi-parameter Photometer with pH meter for Plant Nutrient analysis","description":"\u003cp\u003eOne meter can be used for both photometric and pH measurements. The Hanna Instruments-83325 benchtop photometer measures 8 different plant nutrient water quality parameters using 9 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time. Key parameters are: Ammonia, Calcium, Magnesium, Nitrate, Phosphorus, Potassium, Sulphate and pH.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eHanna Instruments-83325-02 Plant Nutrient Analysis Photometer with pH meter\u003c\/h3\u003e\n\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/p\u003e\n\u003cp\u003eConsistent and thorough monitoring of plant nutrients is essential to maintaining healthy growth and reproduction. This is easy with the Hanna Instruments-83325, a comprehensive way to monitor vital plant nutrients such as potassium, calcium and magnesium. Required in large quantities, potassium plays a vital role in water uptake and enzyme regulation. Calcium helps to strengthen plant cell walls protecting against heat stress while magnesium helps build a strong immune system.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83325 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the three wavelengths of light (420 nm, 466 nm, and 525 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch3\u003eKey features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cli\u003eError Messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354376482967,"sku":"HI-83325-02","price":853.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_4_244ef4df-8e10-4227-a272-550e2bc9fb4e.jpg?v=1624278870"},{"product_id":"hanna-instruments-99162-portable-ph-temperature-meter-for-milk-analysis","title":"Hanna Instruments-99162 Portable pH\/Temperature Meter for Milk Analysis","description":"The Hanna Instruments-99162 is a portable pH and temperature meter designed specifically for milk analysis.\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-99162 is a portable pH and temperature meter designed specifically for milk analysis.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThis meter is supplied with the FC101D pH electrode with internal temperature sensor. The FC101D is composed of food grade PVDF plastic and has a spheric tip providing a large surface area for contact with milk samples. The construction of this electrode provides accurate measurements both on the dairy farm and production facility.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eHanna Instruments-99162 features automatic calibration at one or two points with two sets of buffers. All calibrations and measurements are automatically compensated for temperature variations due to the internal temperature sensor in the FC101D electrode.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThe split-level LCD displays both pH and temperature readings, along with indicators for reading stability, battery percentage, and calibration instructions.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section four\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003cbr\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eApplication specific electrode\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAutomatic temperature compensation (ATC)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eStability indicator for accurate data recording\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eApplication importance\u003c\/h3\u003e\n\u003cbr\u003e\u003cp\u003eThe measurement of pH in milk is important in testing for impurities, spoilage, and signs of mastitis infection. While there are a number of factors that affect the composition of milk, pH measurements can help producers understand what might be causing certain compositional changes. pH measurements are commonly performed at various points in a milk processing plant.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eFresh milk has a pH value of 6.7. When the pH value of the milk falls below pH 6.7, it typically indicates spoilage by bacterial degradation. Bacteria from the family of Lactobacillaceae are lactic acid bacteria (LAB) responsible for the breakdown of the lactose in milk to form lactic acid. Eventually when the milk reaches an acidic enough pH, coagulation or curdling will occur along with the characteristic smell and taste of 'sour' milk.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eMilk with pH values higher than pH 6.7 potentially indicate that the milk may have come from cows infected with mastitis.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eMastitis is an ever-present challenge with dairy milking cows. When infected, the cow's immune system releases histamine and other compounds in response to the infection. There is a resulting increase in permeability of endothelial and epithelial cell layers, allowing blood components to pass through a paracellular pathway. Since blood plasma is slightly alkaline, the resulting pH of milk will be higher than normal. Typically milk producers can perform a somatic cell count to detect a mastitis infection, but a pH measurement offers a quick way to screen for infection.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eUnderstanding the pH of raw milk can also help producers optimise their processing techniques. For example, in operations that use Ultra High Temperature (UHT) processing, even small variations from pH 6.7 can affect the time required for pasteurisation and stability of the milk after treatment.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354376614039,"sku":"HI-99162","price":630.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-99162_portable_phtemperature_meter_for_milk_analysis_64ff2b9a-4218-4cfb-a4a7-50103175c8e7.jpg?v=1624278880"},{"product_id":"hanna-instruments-83308-water-conditioning-photometer-with-ph-meter","title":"Hanna Instruments-83308 Water Conditioning Photometer with pH meter","description":"\u003cp\u003eOne meter can be used for both photometric and pH measurements. This meter has 23 different programmed methods measuring 15 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. Water conditioning parameters include Fluoride, Chlorine, Ammonia, Manganese, Copper, Iron, Silver and Zinc.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 benchtop photometer measures 15 different key water quality parameters using 23 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 was developed to measure the most common parameters in water quality monitoring. One important parameter to test water quality is iron since it can affect colour, odour, and turbidity and can also be the most troublesome factor for appliances and surfaces in contact with water. High levels of iron in water can result in clogged water pipes or heat exchangers.\u003c\/p\u003e\n\u003cp\u003eAdditionally, Ammonia detection in water treatment systems is particularly important for aquarium owners and fish farm operators since ammonia is highly soluble in water and extremely toxic to fish. One other important parameter in water quality monitoring is Fluoride. Fluoride is best known for preventing tooth decay. While it does help prevent tooth decay, too little fluoride can be ineffective while too much can cause staining of teeth.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Instruments-83308 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the four wavelengths of light (420 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch3\u003eKey features:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eError Messages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Focusing Lens for Greater Light Yield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\n\u003cdiv id=\"product_tabs\" class=\"product__tabs\"\u003e\n\u003cdiv class=\"tabs\"\u003e\n\u003cdiv class=\"tab specification active\"\u003e\n\u003cdiv class=\"tab__content\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pH electrode input and 4 photometer wavelengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital pH electrode (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLog on demand with user name and sample ID optional input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-A host for flash drive; micro-USB-B for power and computer connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibration data for connected pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 VDC Li-polymer rechargeable battery\/ \u0026gt;500 photometric measurements or 50 hours of continuous pH measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e206 x 177 x 97mm (8.1 x 7.0 x 3.8\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon Photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e8nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass filter wavelength accruacy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e+-1nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRound, 24.6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Methods\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-83308 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAMMONIA\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 3.00 mg\/L (as NH3-N) Medium Range: 0.00 to 10.00 mg\/L (as NH3-N) High Range: 0.0 to 100.0 mg\/L (as NH3-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading Medium Range: ±0.05 mg\/L ±5% of reading High range: ±0.5 mg\/L ±5% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCHLORINE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA 330.5 DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCOPPER\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.500 mg\/L (as Cu2+) High range: 0.00 to 5.00 mg\/L (as Cu2+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±5% of reading High Range ±0.02 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFLUORIDE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as F-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIRON\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.600 mg\/L (as Fe) High Range: 0.00 to 5.00 mg\/L (as Fe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±8% of reading High Range: ±0.04 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the TPTZ Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMANGANESE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 300 µg\/L (as Mn) High range: 0.0 to 20.0 mg\/L (as Mn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.02 mg\/L ±3% of reading; High Range: ±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMOLYBDENUM\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 40.0 mg\/L (as Mo6+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the mercaptoacetic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNICKEL\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.000 mg\/L (as Ni); High Range: 0.00 to 7.00 g\/L (as Ni)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow range: ±0.010 mg\/L ±7% of reading High Range: ±0.07 g\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN method; High Range: Adaptation of the photometric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNITRATE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L (as NO3-- N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±10% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the cadmium reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOXYGEN, DISSOLVED\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L (as O2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.4 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003epH\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 0.1 pH pH electrode: 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: ±0.1 pH pH electrode: ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eclean electrode and check buffer\/check probe displayed during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotometer: phenol red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePHOSPHATE\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.50 mg\/L (as PO43-) High range: 0.0 to 30.0 mg\/L (as PO43-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading High Range: ±1 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the Ascorbic Acid method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSILICA\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as SiO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSILVER\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.000 mg\/L (as Ag)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.020 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the PAN method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eZINC\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.00 mg\/L (as Zn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eREAGENTS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia HR, MR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93733-01 (100 tests); HI-93733-03 (300 tests); MR - HI-93715-01 (100 tests); HI-93715-03 (300 tests); LR - HI-93700-01 (100 tests); HI-93700-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine - Free\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFree Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Total\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)\u003cbr\u003eChlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93702-01 (100 tests); HI-93702-03 (300 tests)\u003cbr\u003eLR - HI-95747-01 (100 tests); HI-95747-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93739-01 (100 tests); HI-93739-03 (300 tests)\u003cbr\u003eLR - HI-93729-01 (100 tests); HI-93729-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93721-01 (100 tests); HI-93721-03 (300 tests)\u003cbr\u003eLR - HI-93746-01 (100 tests); HI-93746-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese – HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93709-01 (100 tests); HI-93709-03 (300 tests)\u003cbr\u003eLR - HI-93748-01 (50 tests); HI-93748-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93730-01 (100 tests); HI-93730-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel - HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93726-01 (100 tests); HI-93726-03 (300 tests)\u003cbr\u003eLR - HI-93740-01 (50 tests); HI-93740-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93728-01 (100 tests); HI-93728-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Dissolved (DO)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93732-01 (100 tests); HI-93732-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93710-01 (100 tests); HI-93710-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate - HR \u0026amp; LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHR - HI-93717-01 (100 tests); HI-93717-03 (300 tests)\u003cbr\u003eLR - HI-93713-01 (100 tests); HI-93713-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica – LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLR - HI-93705-01 (100 tests); HI-93705-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93737-01 (50 tests); HI-93737-03 (150 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-93731-01 (100 tests); HI-93731-03 (300 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354377793687,"sku":"HI-83308-02","price":717.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83308_water_conditioning_photometer_with_ph_meter_65bd256c-bf7f-4276-8991-38095b909212.jpg?v=1624278907"},{"product_id":"hanna-instruments-83305-02-multi-parameter-photometer-ph-meter-for-boiling-and-cooling-towers","title":"Hanna Instruments-83305-02 Multi-parameter Photometer \u0026 pH Meter for Boiling and Cooling towers","description":"One meter can be used for both photometric and pH measurements. The meter has 30 different programmed methods measuring 18 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves.\u003cbr\u003e\u003ch3\u003eHanna Instruments-83305-02 Boiler and Cooling Tower Photometer with pH digital input\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable benchtop space, the Hanna Instruments-83305 doubles as a professional pH meter with its digital pH\/temperature electrode input. Suitable for use in boiling and cooling tower applications, parameters specific to boiling and cooling towers include oxygen scavengers and silica which are important for maintaining equipment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTo save valuable laboratory benchtop space, the Hanna Instruments-83305 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis photometer features an innovative optical system that uses LEDs, narrow band interference filters, a focusing lens, plus a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source which ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eSpecifically designed for use with boilers and cooling towers, the Hanna Instruments-83305 is a comprehensive way to maintain precise water conditions in systems. Problems such as corrosion, deposition, and microbial growth can occur if these key parameters, such as oxygen scavengers and silica, aren't maintained. Oxygen scavengers are added to remove residual dissolved oxygen in boiler feed water that can cause corrosion in a steam generating plant. It is important that levels of oxygen scavengers be routinely checked to prevent against corrosion and ensure that equipment is working efficiently. Boiler water maintenance is necessary to prevent or control deposit formation as seen with silica. Silica contamination can reduce system efficiency and increase maintenance of equipment due to scaling.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built-in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built-in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83305 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability, the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354378645655,"sku":"HI-83305-02","price":812.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83305-02_multi-parameter_photometer_ph_meter_for_boiling_and_cooling_towers_181f2f4b-06e5-4b51-9be1-abf10313a96a.jpg?v=1624278958"},{"product_id":"hanna-instruments-3887-free-chlorine-and-ph-test-kit","title":"Hanna Instruments-3887 Free Chlorine and pH Test Kit","description":"Chlorine is the most commonly used water disinfectant in applications that vary from treatment of drinking water and wastewater, pools and spas sanitisation, to food processing and sterilisation.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-3887 is a chemical test kit for testing Free Chlorine and pH.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFree chlorine reacts with ammonium ions and organic compounds to form chlorine compounds resulting in diminished disinfecting capabilities compared with free chlorine. These chlorine compounds together with chloramines form combined chlorine. Combined chlorine and excess free chlorine together result in total chlorine. While free chlorine has a much higher disinfectant potential, combined chlorine has a much higher stability and has a lesser volatility. There should be sufficient levels of unreacted free chlorine for adequate disinfection, but not so much as to become harmful.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eOrder Information\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-3887 test kit comes with colour comparison cubes (2), 20 mL reagent 1, 15 mL reagent 2, 25 mL Hanna Instruments-3881-0 pH 6.0-8.5 reagent\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354382708887,"sku":"HI-3887","price":57.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hanna_instruments_3887_free_chlorine_ph_test_kit.jpg?v=1624279068"},{"product_id":"hanna-instruments-935002-2-channel-k-type-thermocouple-thermometer","title":"Hanna Instruments-935002 2-Channel K-Type Thermocouple Thermometer","description":"HI 935002 and HI 935009 are waterproof 2-channel thermometers offering a wide temperature range and an extraordinary 1600 hours of battery life ideal for extended lab and field use.\u003cbr\u003e\u003ch3\u003e2-Channel, K-Type Thermocouple Thermomete\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-935002 is a 2-channel, water resistant, K-type thermometer that offers accurate temperature measurements in a wide range as well as 1600 hours of battery life.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis unit displays current temperature along with the minimum and maximum for each channel achieved during the measuring session. The difference between each channel can be shown, or a relative value can be set on each channel and variances around that value can be monitored.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis instrument is equipped with BEPS (Battery Error Prevention System) which alerts the user in the event that low battery power could adversely affect readings.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eDual input channels\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eOne point calibration\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eWater resistant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUp to 1600 battery life\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eReading storage\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eSupplied with\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eInstructions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354382905495,"sku":"HI-935002","price":214.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-935002_2-channel_k-type_thermocouple_thermometer_ce2167b3-8517-433c-9e1a-04f0c11f5921.jpg?v=1624279073"},{"product_id":"fc230b-food-ph-electrode-for-use-with-fc099-knife-adaptor-1","title":"FC230B Food pH Electrode for use with FC099 Knife Adaptor","description":"The Hanna FC230B features a white foodgrade PTFE spear body with the ability to attach 2 different length knife blades for the measurement of meat products.\u003cbr\u003e\u003cp\u003eThe FC230B features a white food grade PTFE spear body and has the ability to attach two different knife blades for the pH measurement of meat products.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis electrode is supplied complete with a 1m white food cable and standard fit BNC connector allowing it to be used on most types of pH meter.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354386018455,"sku":"FC230B","price":294.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/fc230b_food_ph_electrode_for_use_with_fc099_knife_adaptor_ee2609d0-784b-425a-9d53-79360edcba83.jpg?v=1624279116"},{"product_id":"hanna-instruments-4111-iodine-combination-electrode","title":"Hanna Instruments-4111 Iodine Combination Electrode","description":"The Hanna Instruments-4111 is ideal for a variety of applications in food production and environmental monitoring.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4111 iodide selective electrode is a complete potentiometric cell that contains a silver\/silver chloride (Ag\/AgCl) reference housed within a PEI plastic body with a potassium nitrate electrolyte. The internal elements are isolated from the sample by a compressed silver iodide sensing membrane.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna’s solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFor the Hanna Instruments-4111 to measure iodide accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free iodide ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The Hanna Instruments-4111 iodide solid state ISE can measure from 0.1µM (0.01 mg\/L) to1M (127,000 mg\/L).\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354386772119,"sku":"HI-4111","price":940.41,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-4111_iodine_combination_electrode_2aeb85d0-6cb3-48a0-95e8-ca6abc2cb268.jpg?v=1624279152"},{"product_id":"hanna-instruments-83303k-aquaculture-photometer-kit","title":"Hanna Instruments-83303K Aquaculture Photometer kit","description":"\u003cp\u003e\u003cstrong\u003eHanna Instruments-83303K Aquaculture Photometer Kit\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eKit contains:\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eHI 83303-02 - meter\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93700-01 - ammonia tests x 100\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93732-01 - dissolved oxygen tests x 100\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93710-01 - pH tests x 100\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93728-01 - nitrate tests x 50\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 93707-01 - nitrite tests x 50\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHI 740222N - blue carrying case\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eOne meter can be used for both photometric and pH measurements. The meter has 20 different programmed methods measuring 12 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83303 doubles as a professional pH meter with its digital pH\/temperature electrode input. Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMade with the aquaculture industry in mind, the Hanna Instruments-83303 is a comprehensive solution to maintaining optimal chemical and environmental conditions, preventing disease and increasing production.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 measures vital parameters such as Alkalinity, Calcium, Nitrite, and Phosphate. Alkalinity plays a part in a dynamic relationship with pH and CO2 concentrations, high alkalinity water lowers fluctuations in pH. The buffering capacity acts to store extra CO2 essential for photosynthesis in the ponds to produce oxygen. Maintaining calcium at certain levels is vital to proper fish growth and development. Excessive nitrite can be toxic to fish. When nitrite interacts with Haemoglobin, the iron becomes oxidised and the blood cell can no longer carry oxygen. Phosphate is essential to plant growth; too much phosphate in an aquaculture system can contribute to algal blooms decreasing dissolved oxygen vital for a successful ecosystem.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83303 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHigh Efficiency LED Light Source\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHigh Quality Narrow Band Interference Filters\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eReference Detector for a Stable Light Source\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eLarge Cuvette Size\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83303 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eFocusing Lens for Greater Light Yield\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354386903191,"sku":"HI-83303K","price":913.24,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-83303k_aquaculture_photometer_kit_4005254e-d1f0-4bd5-aba5-9872d22dd173.jpg?v=1624279156"},{"product_id":"hanna-instruments-146-00-wall-mounting-precision-thermometer-with-calcheck®","title":"Hanna Instruments-146-00 Wall-mounting Precision Thermometer with CalCheck®","description":"The Hanna Instruments-146-00 is a high accuracy compact food thermometer designed to be mounted on a wall with a 2m cable sensor.\u003cbr\u003e\u003ch3\u003eall-mounting precision thermometer, °C\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-146-00 is a high accuracy thermometer with a professional grade probe and a flexible 2 m cable.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe CAL CHECK® feature is incorporated into its function to allow you to confirm the accuracy of the meters any time. You can monitor the exact temperature of any product continuously and easily observe it on the LCD display.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-146-00 can be easily carried from station to station or installed in a fixed position using the moulded eye and a wall mount probe holder.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eWith its compact and simplified design featuring a fixed stainless steel probe and optional probe holder, this thermometer is ideal for monitoring the temperatures of liquids, semi-solids and refrigerated foods.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eHACCP compliant\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL CHECK® feature\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eStainless steel temperature probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eWater resistant\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eSupplied with\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eStainless steel temperature probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eInstructions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354389328023,"sku":"HI-146-00","price":114.38,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-146-00_wall-mounting_precision_thermometer_with_calcheck_2320cbc8-c8b8-40f9-87f6-bba4d4a88d83.jpg?v=1624279241"},{"product_id":"fc2423-foodcare-ph-and-temperature-electrode-for-cheese-1","title":"FC2423 Foodcare pH and temperature electrode for cheese","description":"The FC2423 used with the HI-98165 is designed specifically for measuring pH in cheese.\u003cbr\u003e\u003ch3\u003eFC2423 Foodcare pH and temperature electrode for cheese\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eCheese products can provide challenges for the person that needs to measure pH. Cheese products tend to be solid to semi-solids. Both types of samples will coat the sensitive glass membrane surface and\/or clog the reference junction.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFrom a conic tip shape in a durable 5 mm diameter stainless steel body for easy penetration into cheese without leaving a large hole to an open junction that resist clogging; the FC2423 is an ideal general-purpose pH electrode for cheese. The FC2423 connects to the HI-98165 with a quick-connect, waterproof DIN connector, allowing for a secure, non-threaded attachment.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe robust stainless steel sheath paired with the conical sensing tip allows for penetration in cheese at various points throughout the production process. An integrated temperature sensor also ensures that all pH measurements are compensated for temperature without the need for a separate temperature probe.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eMore information\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eStainless steel body\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eConic Glass Tip\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-In Temperature Sensor\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLow temperature glass\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eFor use with the HI-98165 Foodcare meter\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354394996887,"sku":"FC2423","price":342.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/fc2423_foodcare_ph_and_temperature_electrode_for_cheese_35dfb324-a94d-4c99-b7e6-84b23761e561.jpg?v=1624279404"},{"product_id":"hanna-instruments-70632l-electrode-cleaning-and-disinfection-solution-for-blood-products","title":"Hanna Instruments-70632L Electrode Cleaning  and Disinfection Solution for Blood Products","description":"Here at HANNA, we recommend to always clean an electrode after every testing to eliminate impurities and residue. Regular cleansing and proper care ensures the electrode is correctly maintained for maximum performance to achieve accurate readings, faster response times, and repeatability.\u003cbr\u003e\u003ch3\u003eHanna Instruments-70632L Cleaning \u0026amp; Disinfection Solution for Blood Products (500 mL)\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-70632L is a highly-effective cleaning and disinfection solution specially formulated for use in applications where a pH electrode is in contact with blood products.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eElectrodes become dirty from use and will produce inaccurate results even if they read correctly in a pH buffer. HANNA’s cleaning solutions eliminate impurities and residues which are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAt HANNA, we suggest cleaning the bulb and junction of your electrode on a regular basis in our ready-to-use cleaning solutions to ensure that the probe is always clean and to prevent any clogging of the junction.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAll cleaning solutions are packaged in an air tight bottle with tamper-proof seal to ensure quality and freshness. All solutions show a batch number and expiry date.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAvailable in 500ml bottles. \u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eUseful tips:\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAfter cleaning, rinse the electrode in tap water and then place in a HANNA Storage Solution before calibrating or taking measurements.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlways follow up with a HANNA Buffer\/calibrating Solution for the best results.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eWhich cleaning solution to use . . .?\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eGeneral Cleaning\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eSoak in HANNA General Cleaning Solution (Hanna Instruments-7061) for between 30 minutes and 1-and-a-half hours to dissolve mineral deposits and other general coatings. (Non-aggressive formula).\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eProtein Coating\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eSoak in HANNA Protein Cleaning Solution (Hanna Instruments-7073) for 15 minutes to enzymatically dissolve deposits from protein sources.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eInorganic Soak\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eSoak in HANNA Inorganic Cleaning Solution (Hanna Instruments-7074) for 5 to 15 minutes. This cleaner is especially effective at removal of precipitates caused by possible reactions - Usually used in industrial applications.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eOil and Grease Rinse\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eOil and grease removal require the correct chemicals to dissolve the coating, but mild enough to leave the electrode unaffected. Use HANNA Hanna Instruments-7007 or Hanna Instruments-8077 Oil and Fat Cleaning Solution for effective cleaning after each measurement, followed by flushing with tap water.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eSpecialised Cleaning Solutions\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eWine deposits (Hanna Instruments-70635L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eWine stains (Hanna Instruments-70636L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSalt (Hanna Instruments-70670L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCheese (Hanna Instruments-70642L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eMilk (Hanna Instruments-70640L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDairy – Cleaning and Disinfection Solution (Hanna Instruments-70641)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSoil (Hanna Instruments-70663L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHumus (Hanna Instruments-70664L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAgricultural (Hanna Instruments-700661P)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eInk (Hanna Instruments-70681L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlgae, Fungi and Bacteria (Hanna Instruments-70671L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBlood – Cleaning and Disinfection Solution (Hanna Instruments-70632L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlkaline cleaning for meat grease and fats (Hanna Instruments-70631L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAcid cleaning solution for meat grease and fats (Hanna Instruments-700630P)\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eRemember:\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eCleaning is a fast and effective routine which should be performed on a regular basis as a preventative measure against using dirty equipment.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlways clean the junction and bulb of the electrode\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlways clean your meter, electrode or probe before calibration\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, modern pH meters assume that the electrode is clean and will give you a starting point accordingly. So, if you haven’t cleaned your meter, your readings will be inaccurate from the start.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eAll ready-to-use cleaning solutions are made with the highest quality of materials and chemicals complying with standards set by the National Institute of Standards and Technology (NIST), to ensure quality and accuracy. Also available in light blocking bottles to prevent against degradation by UV light compatible with FDA Standards (US Food and Drug Administration).\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354395095191,"sku":"HI-70632L","price":39.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-70632l_electrode_cleaning_and_disinfection_solution_for_blood_products_952e47bf-da82-4e51-ac06-3dad0e8fdb3c.jpg?v=1624279404"},{"product_id":"hanna-instruments-4110-fluoride-combination-ise-electrode","title":"Hanna Instruments-4110 Fluoride Combination ISE Electrode","description":"\u003cp\u003eThe Hanna Instruments-4110 is a solid state, combination ion selective electrode (ISE) for the determination of fluoride (F-) in solution. The lanthanum fluoride crystal membrane produces a potential change due to the fluoride ion exchange between the membrane and the sample. The internal sensing elements are housed within a durable body, composed of a mixture of polyetherimide (PEI) and epoxy.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4110 is ideal for a variety of applications in drinking water treatment, environmental monitoring, and plating baths.\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eSolid state sensor\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSkirted cone geometry\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDetection from 0.02 mg\/L to saturated F-\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4110 is a Fluoride combination ISE ideal for the detection of Free Fluoride in potable water, soft drinks, wine, plants, emulsified food products, plating and pickling acids.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-4110 fluoride selective electrode is a complete potentiometric cell that contains a silver\/silver chloride (Ag\/AgCl) reference housed within a PEI\/epoxy body with a potassium nitrate\/potassium chloride electrolyte. The internal elements are isolated from the sample by a lanthanum fluoride crystal membrane.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHanna’s solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFor the Hanna Instruments-4110 to accurately measure total fluoride concentration, it is important that the pH and ionic strength of the standards and sample be adjusted to a constant value. The total ionic strength adjustment buffer (TISAB) ensures that the solution pH is between pH 5 and 8 and that the activity coefficient is constant. The TISAB solution also preferentially complexes with various metal ions, such as aluminium and iron, which tend to form complexes with fluoride ions. TISAB thus ensures that these metal ions do not interfere, permitting an accurate total fluoride measurement. Measuring all solutions with a constant pH and ionic strength reduces the margin of error between measurements. The Hanna Instruments-4110 fluoride solid state ion selective electrodes can measure from 1µM (0.02 mg\/L) to saturated F-.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eReplaceable Sensing Modules - Combination solid state ion selective electrodes are electrodes that detect free ions in a solution. The lanthanum fluoride crystal sensing membrane is replaceable and easy to attach to the sensor body.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDurable PEI Body - The probe body is composed of a mixture of polyetherimide (PEI) and epoxy.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBNC Connection - The Hanna Instruments-4110 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354396340375,"sku":"HI-4110","price":995.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-4110_fluoride_combination_ise_electrode_4bf12a2f-f651-47a3-938b-8ca7a9bf197e.jpg?v=1624279453"},{"product_id":"hanna-instruments-96832-refractometer-for-propylene-glycol","title":"Hanna Instruments-96832 Refractometer for Propylene Glycol","description":"\u003cform action=\"https:\/\/www.hannainstruments.co.uk\/checkout\/cart\/add\/uenc\/aHR0cHM6Ly93d3cuaGFubmFpbnN0cnVtZW50cy5jby51ay9wcm9weWxlbmUtZ2x5Y29sLXJlZnJhY3RvbWV0ZXItMC0xMDAuaHRtbA,,\/product\/1725\/form_key\/A5v7u5usUOjSHa38\/\" id=\"product_addtocart_form\" method=\"post\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__product-essential__product-shop col-sm-5 col-xs-12 rem-pad-mobile rem-p-r\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__product-essential__product-shop__short-description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"std\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-96832 Propylene Glycol Digital Refractometer is a rugged, portable, water resistant device that utilises the measurement of refractive index to determine the percentage volume and freezing point of propylene glycol based solutions.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/form\u003e\u003cbr\u003e\u003cdiv class=\"product-view__roundels col-xs-12 col-sm-5 rem-p-r\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/waterresistant_roundel_219.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eWater Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/battery_roundel_254.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eBattery powered – Allows use away from a power source. Batteries are included with all battery operated products.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cp\u003eThis digital refractometer eliminates the uncertainty associated with mechanical refractometers. Hanna Instruments-96832 samples are measured after a simple user calibration with distilled or deionised water.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eWithin seconds, the refractive index and temperature are measured and converted into one of two measurement units; % volume or freezing point.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis meter uses internationally recognised references for unit conversion and temperature compensation for glycol solutions.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eDual-level LCD displays measurement and temperature readings simultaneously\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAutomatic Temperature Compensation for accurate measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eEasy measurement; place a few drops of the sample in the well and press the READ key\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eMain benefits\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eQuick, accurate results, readings are displayed in approximately 1.5 seconds\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSingle point calibration with distilled or deionised water\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSmall sample size; can be as small as 2 metric drops\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eStainless steel sample well, easy to clean and corrosion resistant\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eSupplied with\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eBattery\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eInstructions\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354396602519,"sku":"HI-96832","price":323.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-96832_refractometer_for_propylene_glycol_ed892abb-8134-448d-a314-f2787e6e707a.jpg?v=1624279455"},{"product_id":"hanna-instruments-96801-refractometer-for-general-purpose-sugars","title":"Hanna Instruments-96801 Refractometer for General Purpose Sugars","description":"\u003cform action=\"https:\/\/www.hannainstruments.co.uk\/checkout\/cart\/add\/uenc\/aHR0cHM6Ly93d3cuaGFubmFpbnN0cnVtZW50cy5jby51ay9yZWZyYWN0b21ldGVyLWdlbmVyYWwtcHVycG9zZS1zdWdhcnMuaHRtbA,,\/product\/1712\/form_key\/A5v7u5usUOjSHa38\/\" id=\"product_addtocart_form\" method=\"post\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__product-essential__product-shop col-sm-5 col-xs-12 rem-pad-mobile rem-p-r\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__product-essential__product-shop__short-description\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"std\"\u003e\n\u003cbr\u003e\n\u003cp\u003eThe Hanna Instruments-96801 measures the refractive index to determine the % Brix of sugar in aqueous solutions. The refractive index of the sample is converted to % Brix concentration units.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eHanna offers five sugar refractometers to meet the requirements of the food industry. The Hanna Instruments-96800 Refractive Index\/Brix, Hanna Instruments-96801 % Brix (sucrose), Hanna Instruments-96802 Fructose, Hi-96803 Glucose, and Hanna Instruments-96804 Invert Sugar digital refractometers are rugged, portable and water-resistant for measurements in the lab or field.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/form\u003e\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels col-xs-12 col-sm-5 rem-p-r\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/waterresistant_roundel_207.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eWater Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/battery_roundel_242.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eBattery powered – Allows use away from a power source. Batteries are included with all battery operated products.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\n\u003cp\u003eThe Hanna Instruments-98601 is used across the food industry for measuring the concentrations of general purpose sugars in foods.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eQuick and easy to use it is ideal for analysing the sugar content in a wide range of food products including fruit, energy drinks, puddings, tofu, jams, honey, soups and sauces.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003ePriced inexpensively does not mean a compromise on accuracy, the Hanna refractometer offers all the benefits of high precision digital technology at the same price as a mechanical model.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eThe Hanna Instruments-96801 measures the refractive index to determine the % Brix of sugar in aqueous solutions. The refractive index of the sample is then converted to % Brix concentration units.\u003c\/p\u003e\n\u003cbr\u003e\n\u003ch3\u003eProduct uses\u003c\/h3\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eFruit growers and importers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eFruit juice \u0026amp; drink manufacturers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eProduction of jams, preserves \u0026amp; sauces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ch3\u003eOrder Information\u003c\/h3\u003e\n\u003cbr\u003e\n\u003cp\u003eThe following options are available below:\u003c\/p\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eHanna Instruments-96801 - Sucrose sugar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eHanna Instruments-96802 - Fructose sugar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eHanna Instruments-96803 - Glucose sugar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eHanna Instruments-96804 - Inverted sugar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"section-row section four\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003cbr\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eWhite, water resistant, casing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEasy clean sample well\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eZero using pure water\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBattery operated with auto shut-off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ch3\u003eMain benefits\u003c\/h3\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e1.5 second measurement time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eDirect readout in % Brix and °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eNo calibration solutions required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eLarge clear LCD display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354397520023,"sku":"HI-96801","price":355.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/image_13775_85edda50-ad6d-426b-83b6-03797b578e7d.jpg?v=1624279473"},{"product_id":"hanna-instruments-76320-karl-fischer-dual-platinum-pin-electrode-for-hanna-instruments-903","title":"Hanna Instruments-76320 Karl Fischer Dual Platinum Pin electrode for Hanna Instruments-903","description":"For use with the Karl Fischer Hanna Instruments-903 Titrator.\u003cbr\u003e\u003ch3\u003eKarl Fischer Dual Platinum Pin electrode for Hanna Instruments-903\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-76320 is a glass bodied, dual platinum pin electrode for use with the Hanna Instruments-903 Karl Fischer titration system. Each sensor is designed for sensitive, precise, and accurate readings.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eMore features:\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eGlass Body\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDual Platinum Pin\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBNC Connection\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354417508503,"sku":"HI-76320","price":534.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-76320_karl_fischer_dual_platinum_pin_electrode_for_hi-903_327bf69a-4202-4d85-8ebe-a0fbd5947e4c.jpg?v=1624279798"},{"product_id":"hanna-instruments-96800-refractometer-for-refractive-index-and-brix","title":"Hanna Instruments-96800 Refractometer for Refractive Index and Brix","description":"\u003cform action=\"https:\/\/www.hannainstruments.co.uk\/checkout\/cart\/add\/uenc\/aHR0cHM6Ly93d3cuaGFubmFpbnN0cnVtZW50cy5jby51ay9oaS05NjgwMC1yZWZyYWN0b21ldGVyLWZvci1yZWZyYWN0aXZlLWluZGV4LWFuZC1icml4Lmh0bWw,\/product\/2123\/form_key\/n3eF8SH4IMUYpSbL\/\" id=\"product_addtocart_form\" method=\"post\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__product-essential__product-shop col-sm-5 col-xs-12 rem-pad-mobile rem-p-r\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__product-essential__product-shop__short-description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"std\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-96800 measures the refractive index in aqueous solutions. Readings can also be displayed with sucrose temperature compensation (nD\u003csub\u003e20\u003c\/sub\u003e) or % Brix.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eHanna offers five sugar refractometers to meet the requirements of the food industry. The Hanna Instruments-96800 Refractive Index\/Brix, Hanna Instruments-96801 % Brix (sucrose), Hanna Instruments-96802 Fructose, Hi-96803 Glucose, and Hanna Instruments-96804 Invert Sugar digital refractometers are rugged, portable and water-resistant for measurements in the lab or field.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/form\u003e\u003cbr\u003e\u003cdiv class=\"product-view__roundels col-xs-12 col-sm-5 rem-p-r\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/battery_roundel_241.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eBattery powered – Allows use away from a power source. Batteries are included with all battery operated products.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__img\"\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/waterresistant_roundel_206.jpg\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"product-view__roundels__roundel-row__text\"\u003eWater Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-96800 measures the refractive index to determine the % Brix of sugar in aqueous solutions.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eQuick and easy to use it is ideal for analysing the sugar content in a wide range of food products including fruit, energy drinks, puddings, tofu, jams, honey, soups and sauces.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eProduct uses\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFruit growers and importers\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eFruit juice \u0026amp; drink manufacturers\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eProduction of jams, preserves \u0026amp; sauces\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eWhite, water resistant, casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eEasy clean sample well\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eZero using pure water\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery operated with auto shut-off\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eMain benefits\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003e1.5 second measurement time\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDirect readout in % volume or freezing point\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e0.1% resolution with 0.3% accuracy\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eClear LCD display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354438742167,"sku":"HI-96800","price":498.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-96800_refractometer_for_refractive_index_and_brix_0a50f418-80b5-4198-a5ae-99b423682e32.jpg?v=1624280126"},{"product_id":"hanna-instruments-99300-ec-tds-temperature-meter","title":"Hanna Instruments-99300 EC\/TDS\/Temperature Meter","description":"\u003cdiv class=\"row\"\u003e\n\u003cp\u003eThe HI-99300 is a portable, EC\/TDS\/temperature meter that measures low range conductivity in µS\/cm and TDS in ppm. It is housed in a case rated for IP67 conditions.\u003c\/p\u003e\n\u003cp\u003eThis instrument offers single point, automatic calibration with automatically temperature compensated measurements. The compensation coefficient and EC\/TDS conversion factor are user-selectable from 0.45 to 1.00 and temperature coefficient is selectable from 0.0 to 2.4%\/°C.\u003c\/p\u003e\n\u003cp\u003eThe meter easily fits in the palm of your hand and the bottom probe connection ensures the electrode cable doesn't get in your way. The large, multi-level LCD displays the primary reading, temperature and calibration guides simultaneously. Symbols and messages on the LCD indicate meter status and guides users through operations.\u003c\/p\u003e\n\u003cp\u003eAt start-up, the meter shows the remaining battery percentage and when a low battery condition is detected, a battery symbol appears on the LCD to advise the user that only a few hours of working time is left.\u003c\/p\u003e\n\u003cp\u003eThe HI-76306 EC\/TDS\/temperature probe resists clogging and is easy to clean.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIdeal for\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePure Water\u003c\/li\u003e\n\u003cli\u003eTap Water\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMain benefits\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli\u003eBattery % displayed on start-up\u003c\/li\u003e\n\u003cli\u003eCompact, heavy-duty and water resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eKey features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAmperometric probe technology\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eAutomatic single calibration with calibration indicator\u003c\/li\u003e\n\u003cli\u003eOn-screen tutorial messages for calibration and set-up\u003c\/li\u003e\n\u003cli\u003eReplacement probe - HI-763063\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange - EC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange - TDS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange - Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution - EC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution - TDS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution - Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy - EC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy - TDS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy - Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ ±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eadjustable, from 0.45 to 1.00 with 0.01 increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic, 1 point at 1382 ppm (CONV 0.5)\u003cbr\u003eor at 1500 ppm (CONV 0.7)\u003cbr\u003eor at 1413 µS\/cm (others)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, 0 to 60°C (32 to 140°F) with ß adjustable\u003cbr\u003efrom 0.0 to 2.4% with 0.1% increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI 763063, EC\/TDS\/temperature sensor, with DIN connector,\u003cbr\u003e1 m (3.3') cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x 1.5V AAA \/ approx. 500 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e154 x 63 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e196g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354438906007,"sku":"HI-99300N","price":274.01,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-99300_ectdstemperature_meter_02294a3d-d35d-40e5-a1de-4bc29072074f.jpg?v=1624280137"},{"product_id":"hanna-instruments-96804-refractometer-for-inverted-sugar-0-to-85-scale","title":"Hanna Instruments-96804 Refractometer for Inverted sugar 0 to 85% scale","description":"Hanna Instruments-96804 measures the refractive index to determine the % invert sugar in aqueous solutions. The refractive index of the sample is converted to % mass (%w\/w) concentration units.\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-98604 is used across the food industry for measuring the % invert sugar in foods.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eQuick and easy to use it is ideal for analysing the sugar content in a wide range of food products including fruit, energy drinks, puddings, tofu, jams, honey, soups and sauces.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003ePriced inexpensively does not mean a compromise on accuracy, the Hanna refractometer offers all the benefits of high precision digital technology at the same price as a mechanical model.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-96804 measures the refractive index to determine the % invert sugar in aqueous solutions. The refractive index of the sample is then converted to % by weight concentration units.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eProduct uses\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eFruit growers and importers\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eFruit juice \u0026amp; drink manufacturers\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eProduction of jams, preserves \u0026amp; sauces\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eWhite water resistant casing\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eEasy clean sample well\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eZero using pure water\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery operated with auto shut-off\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eMain benefits\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003e1.5 second measurement time\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDirect readout in % Brix and °C\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eNo calibration solutions required\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLarge clear LCD display\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354440315031,"sku":"HI-96804","price":323.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-96804_refractometer_for_inverted_sugar_0_to_85_scale_329a9057-feec-4c68-98e7-7a76d1793ce4.jpg?v=1624280186"},{"product_id":"hanna-instruments-70636l-electrode-cleaning-solution-for-wine-stains","title":"Hanna Instruments-70636L Electrode Cleaning Solution for Wine Stains","description":"\u003cp\u003e\u003cstrong\u003eAim for accurate readings every time with a wide variety of ready-to-use HANNA cleaning solutions.\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eHere at HANNA, we recommend to always clean an electrode after every testing to eliminate impurities and residue. Regular cleansing and proper care ensures the electrode is correctly maintained for maximum performance to achieve accurate readings, faster response times, and repeatability.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHanna Instruments-70636L Cleaning Solution for Wine Stains (500ml)\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-70636L is a highly-effective cleaning solution, specially formulated for use with pH electrodes stained with wine juice and must deposits. Measuring the pH in wine is a critical, indeed the most important step in ensuring the very best quality of the final product.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003epH affects everything from fermentation to microbial stability and taste. Improper pH measurement can mean readings are up to a 0.5 pH unit off. This variability risks spoilage and other serious quality issues.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e*An ebook on The Essential Guide to Measuring pH in Wine will be available very shortly. Visit us again for updates.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eElectrodes become dirty from use and will produce inaccurate results even if they read correctly in a pH buffer. HANNA’s cleaning solutions eliminate impurities and residues which are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAt HANNA, we suggest cleaning the bulb and junction of your electrode on a regular basis in our ready-to-use cleaning solutions to ensure that the probe is always clean and to prevent any clogging of the junction.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAll cleaning solutions are packaged in an air tight bottle with tamper-proof seal to ensure quality and freshness. All solutions show a batch number and expiry date.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eAvailable in 500ml bottles, and individual 20ml sachets in packs of 25.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eUseful tips:\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAfter cleaning, rinse the electrode in tap water and then place in a HANNA Storage Solution before calibrating or taking measurements.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlways follow up with a HANNA Buffer\/calibrating Solution for the best results.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eWhich cleaning solution to use . . .?\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eGeneral Cleaning\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eSoak in HANNA General Cleaning Solution (HI7061) for between 30 minutes and 1-and-a-half hours to dissolve mineral deposits and other general coatings. (Non-aggressive formula).\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eProtein Coating\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eSoak in HANNA Protein Cleaning Solution (Hanna Instruments-7073) for 15 minutes to enzymatically dissolve deposits from protein sources.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eInorganic Soak\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eSoak in HANNA Inorganic Cleaning Solution (Hanna Instruments-7074) for 5 to 15 minutes. This cleaner is especially effective at removal of precipitates caused by possible reactions - Usually used in industrial applications.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eOil and Grease Rinse\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eOil and grease removal require the correct chemicals to dissolve the coating, but mild enough to leave the electrode unaffected. Use HANNA Hanna Instruments-7007 or Hanna Instruments-8077 Oil and Fat Cleaning Solution for effective cleaning after each measurement, followed by flushing with tap water.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eSpecialised Cleaning Solutions\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eWine deposits (Hanna Instruments-70635L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eWine stains (Hanna Instruments-70636L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSalt (Hanna Instruments-70670L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCheese (Hanna Instruments-70642L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eMilk (Hanna Instruments-70640L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eDairy – Cleaning and Disinfection Solution (Hanna Instruments-70641)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSoil (Hanna Instruments-70663L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eHumus (Hanna Instruments-70664L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAgricultural (Hanna Instruments-700661P)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eInk (Hanna Instruments-70681L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlgae, Fungi and Bacteria (Hanna Instruments-70671L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBlood – Cleaning and Disinfection Solution (Hanna Instruments-70632L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlkaline cleaning for meat grease and fats (Hanna Instruments-70631L)\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAcid cleaning solution for meat grease and fats (Hanna Instruments-700630P)\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eRemember:\u003c\/strong\u003e\u003c\/p\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eCleaning is a fast and effective routine which should be performed on a regular basis as a preventative measure against using dirty equipment.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlways clean the junction and bulb of the electrode\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAlways clean your meter, electrode or probe before calibration\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, modern pH meters assume that the electrode is clean and will give you a starting point accordingly. So, if you haven’t cleaned your meter, your readings will be inaccurate from the start.\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp\u003eAll ready-to-use cleaning solutions are made with the highest quality of materials and chemicals complying with standards set by the National Institute of Standards and Technology (NIST), to ensure quality and accuracy. Also available in light blocking bottles to prevent against degradation by UV light compatible with FDA Standards (US Food and Drug Administration).\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354451619991,"sku":"HI-70636L","price":39.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/image_13277_193e76c0-7e66-40d1-86c3-2d17719c317b.jpg?v=1624280411"},{"product_id":"hanna-instruments-1053p-ph-combination-electrode-with-conical-tip-bnc-connector-and-pin","title":"Hanna Instruments-1053P pH Combination Electrode with Conical Tip, BNC connector and Pin","description":"pH Combination electrode with pin, glass body, triple ceramic.\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-1053P is a refillable combination pH electrode, with conical tip, BNC connector and Pin.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThis electrode is recommended for use with fats and creams, soil samples, potable water, semi-solid products, low conductivity solutions and emulsions.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section four\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003cbr\u003e\u003cbr\u003e\u003ch3\u003eRecommended operating temperature:\u003c\/h3\u003e\n\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003e-5 to 70°C\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003epH Range:\u003c\/h3\u003e\n\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003epH: 0 to 12\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cp\u003eFor fats, creams, soil samples, potable water, semi-solid products, low conductivity solutions, emulsions.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354453061783,"sku":"HI-1053P","price":251.47,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/image_12728_8047b03f-8e06-42a8-a071-a92db7eeb900.jpg?v=1624280440"},{"product_id":"hanna-instruments-701-free-chlorine-handheld-colorimeter-checker®hc","title":"Hanna Instruments-701 Free Chlorine Handheld Colorimeter - Checker®HC","description":"\u003cp\u003eIdeal for swimming pools, spas and aquariums.\u003c\/p\u003e\n\u003cp\u003eChlorine is the most common water disinfectant and by monitoring chlorine regularly and accurately, serious health and safety risks can be avoided.\u003c\/p\u003e\n\u003cp\u003eCan also be used to determine chlorine levels in fish tanks for optimum fish and plant health. Use alongside recommended dechlorinators.\u003c\/p\u003e\n\u003cp\u003eChecker®HC is supplied with reagents for 6 tests. Use code Hanna Instruments-701-25 (25 tests) for future purchases.\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003ch3\u003eIdeal for swimming pools, spas and aquariums\u003c\/h3\u003e\n\u003cp\u003eChlorine is the most common water disinfectant and by monitoring chlorine regularly and accurately, serious health and safety risks can be avoided.\u003c\/p\u003e\n\u003cp\u003eThe contoured style of the Hanna Instruments-701 Free Chlorine Checker is designed to fit in the palm of your hand. The large LCD is easy to read and the auto shut-off feature ensures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003eCan also be used to determine chlorine levels in fish tanks for optimum fish and plant health. Use alongside recommended dechlorinators.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"section-row section four\"\u003e\n\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003ch3\u003eIdeal for\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eSwimming pools and spas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eFruit, vegetable and salad washing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eDisinfection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAquaculture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMain Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eTesting is quick and easy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eHigh precision results - more accurate than chemical test kits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAuto shut-off feature means the Checker cannot be left on by mistake\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eFully portable, fitting easily into both palm and pocket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e2 sample cuvettes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eCuvette cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eStarter pack of reagents (re-ordering information - Hanna Instruments-701-25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1.5 AAA battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFour steps, one click instant readout\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eZero the Checker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eAdd reagent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eInsert sample into Checker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003ePress button for results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecision\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3% of reading ±0.03 ppm (mg\/L) @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 2 minutes of non-use and after read\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of USEPA method 330.5. The reaction between free chlorine and the DPD reagent will cause a pint tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePLEASE NOTE:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eIn some cases, samples may contain other parameters which may interfere with results\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference may be caused by:\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBromine, Iodine, Ozone, Oxidized forms of Chromium and Manganese. In case of water with hardness greater than 500 mg\/L CaCO\u003csub\u003e3\u003c\/sub\u003e, shake the sample for approximately 2 minutes after adding the powder reagent.\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eIf the water used for this procedure has an alkalinity value greater than 250 mg\/L CaCO\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eor acidity value greater than 150 mg\/L CaCO\u003csub\u003e3\u003c\/sub\u003e, the colour of the sample may develop only partially, or may rapidly fade. To resolve this, neutralise the sample with diluted HCl or NaOH.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354486091927,"sku":"HI-701","price":71.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi701_300caf6c-822a-477d-baf5-ad9ce80349fc.jpg?v=1624280638"},{"product_id":"hanna-instruments-721-high-range-iron-handheld-colorimeter-checker®hc","title":"Hanna Instruments-721 High Range Iron Handheld Colorimeter - Checker®HC","description":"\u003cp\u003eThe Hanna Instruments-721 pocket checker for iron gives quick, accurate results at the price of a chemical test kit.\u003c\/p\u003e\n\u003cp\u003eChecker®HC is supplied with reagents for 6 tests. Use code Hanna Instruments-721-25 (25 tests) for future purchases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwimming pools and spas\u003c\/li\u003e\n\u003cli\u003eAquaculture\u003c\/li\u003e\n\u003cli\u003eQuality control and ground water monitoring\u003c\/li\u003e\n\u003cli\u003eAgriculture and small holdings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cstrong\u003eHanna Instruments-721 High Range Iron Handheld Colorimeter - Checker®HC\u003c\/strong\u003e\n\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\n\u003cp\u003eAbout 6.3% of the earth crust is made of iron with 43% of this amount held in the soil. As a result, iron is naturally present in most water supplies.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eLeft in the water, iron will not only stain pipework and swimming pool surfaces, or poison aquatic life, it will also affect the water taste and cause problems with animal feed lines.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eTesting should therefore form an important part of any water monitoring process - particularly if you are checking your pool, watching the quality of water in your fish tank or needing to monitor water run-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cstrong\u003eKey features\u003c\/strong\u003e\n\u003cdiv class=\"section-row section four\"\u003e\n\u003cdiv class=\"section-text col-xs-12 col-sm-7 add-p-r rem-p-l\"\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate and easy to use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003ePhenanthroline method\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eAccuracy ±0.04 mg\/L (ppm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e0.01 mg\/L (ppm) resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to work with Hanna reagents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eLarge easy to read digits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eAuto shut-off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eFits into the palm of your hand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e2 sample cuvettes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e1 black cuvette cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eStarter pack of 6 reagents for Iron (re-ordering information Hanna Instruments-721-25 x 25 tests)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1.5V AAA battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354486485143,"sku":"HI-721","price":71.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi721_1a2c8da1-b02b-4597-b66c-cecca14216bb.jpg?v=1624280667"},{"product_id":"hanna-instruments-10530-ph-edge-electrode","title":"Hanna Instruments-10530 pH Edge Electrode","description":"\u003cp\u003eThe Hanna Instruments-10530 is a smart pH electrode for use with the Hanna Instruments-2020 Edge hybrid meter.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-10530 is a digital glass body, refillable, double junction pH electrode that has a built-in temperature sensor. This probe features a 3.5 mm connector designed exclusively to be used with Hanna Instruments edge® Tablet Meters.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThis design is ideal for emulsions, fats and creams, soil and semi-solid samples, low conductivity solutions, and for measuring samples at cold temperatures.\u003c\/p\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section 1\" id=\"description\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-12 rem-p-l rem-p-r\"\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-10530 is a smart pH electrode for use with the Hanna Instruments-2020 Edge hybrid meter.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-10530 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a triple ceramic junction in the outer junction and the conical pH sensing portion is made with low temperature glass.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThis electrode features a built-in microchip that stores sensor type, ID, and calibration information that is automatically retrieved by Edge once the electrode is plugged in.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eStored pH calibration information includes: calibrated buffers, date, time, offset and slope characteristics of the electrode.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-10530 features an easy to plug in 3.5mm connector and is recommended for use in fats and creams, soil samples, potable water, semi-solid products, low conductivity solutions and emulsions.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cdiv class=\"row\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-row section nine\"\u003e\n\u003cbr\u003e\u003cdiv class=\"col-xs-12 col-sm-6 rem-pad-mobile rem-p-l\"\u003e\n\u003cbr\u003e\u003cdiv class=\"section-image col-xs-5 col-sm-3 circle-left\"\u003e\u003cimg alt=\"\" class=\"img-responsive\" src=\"https:\/\/www.hannainstruments.co.uk\/media\/catalog\/product\/phono_roundel_45.jpg\" title=\"\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv class=\"section-text col-xs-7 col-sm-9\"\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cp\u003e3.5 Connection – Phono plug electrode connection used on HANNA smart Edge electrodes. Provides a secure, easy-to-use connection.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354494578839,"sku":"HI-10530","price":279.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/image_11605_ec0f3705-6926-4470-b84d-1a9073d1d4b7.jpg?v=1624280748"},{"product_id":"hanna-insturments-hi-762-ultra-low-range-free-chlorine-handheld-colorimeter-checker®hc","title":"Hanna Insturments HI-762 Ultra Low Range Free Chlorine Handheld Colorimeter, Checker®HC(with 25 tests)","description":"\u003ch1\u003eHanna Insturments HI-762 Ultra Low Range Free Chlorine Handheld Colorimeter, Checker®HC\u003c\/h1\u003e\n\u003cp\u003eChlorine is the most common water disinfectant and by monitoring chlorine regularly and accurately, serious health and safety risks can be avoided.\u003c\/p\u003e\n\u003cp\u003eThe Hanna Free Chlorine Ultra Low Range Checker® bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits have limited accuracy and resolution since they rely upon the human eye to discern differences in color\u003c\/p\u003e\n\u003cp\u003eProfessional instrumentation incorporates a light source such as an LED or tungsten lamp with a filter and a light sensing detector to precisely determine ion concentration. Professional instrumentation offers greater resolution and accuracy but can cost hundreds of dollars. The Hanna Free Chlorine Ultra Low Range Checker® uses a fixed wavelength LED and silicon photo detector to provide the accuracy of professional instrumentation at the affordable price of a chemical test kit.\u003c\/p\u003e\n\u003cp\u003eThe contoured style of the HI-762 ultra-low range Free Chlorine Checker is designed to fit in the palm of your hand. The large LCD is easy to read and the auto shut-off feature ensures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eIdeal for\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwimming pools and spas\u003c\/li\u003e\n\u003cli\u003eFruit, vegetable and salad washing\u003c\/li\u003e\n\u003cli\u003eDisinfection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eMain Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTesting is quick and easy\u003c\/li\u003e\n\u003cli\u003eHigh precision results - more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eAuto shut-off feature means the Checker cannot be left on by mistake\u003c\/li\u003e\n\u003cli\u003eFully portable, fitting easily into both palm and pocket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSupplied with\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 sample cuvettes\u003c\/li\u003e\n\u003cli\u003eCuvette cap\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePack of Reagents x 25 tests\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e1 x 1.5 AAA battery\u003c\/li\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRange 0 to 500 ppb\u003c\/p\u003e\n\u003cp\u003eResolution 1 ppb\u003c\/p\u003e\n\u003cp\u003eAccuracy @ 25°C ±4% of reading ±20ppb\u003c\/p\u003e\n\u003cp\u003eLight Source LED @ 525 nm\u003c\/p\u003e\n\u003cp\u003eLight Detector Silicon photocell\u003c\/p\u003e\n\u003cp\u003eEnvironment 0 to 50°C; RH max 95% non-condensing\u003c\/p\u003e\n\u003cp\u003eBattery Type (1) 1.5V AAA\u003c\/p\u003e\n\u003cp\u003eAuto-off After 10 minutes of non-use\u003c\/p\u003e\n\u003cp\u003eDimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5\")\u003c\/p\u003e\n\u003cp\u003eWeight 64 g\u003c\/p\u003e\n\u003cp\u003eMethod adaptation of USEPA method 330.5, DPD method\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSku: HI-762\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"HI-762","offer_id":56409686278517,"sku":"HI-762","price":85.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-762-ultra-low-range-free-chlorine-checker-0-to-500ppb.jpg?v=1732285610"},{"product_id":"hanna-instruments-hi-713-phosphate-low-range-handheld-colorimeter-checker-hc","title":"Hanna Instruments HI-713 Phosphate Low Range Handheld Colorimeter - Checker HC","description":"\u003cp\u003eThe Hanna Instruments Phosphate Low Rnage Handheld Colorimeter Checker, is a compact and reliable tool designed for accurate measurement of phosphate levels in water. Ideal for water systems uch as aquaculture, wastewater treatment and freshwater systems, this colorimeter ensures precise testing to help maintain water quality. \u003c\/p\u003e\n\u003cp\u003eIts user friendly design allows you to easily analyse samples with just a few simple steps. \u003c\/p\u003e\n\u003cp\u003eLightweight and portable, this handheld colorimeter is perfect for fieldwork and laboratory use, making it an essential tool for professionals and enhusiasts alike. \u003c\/p\u003e\n\u003cp\u003eChecker range: 0.00 to 2.50 ppm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for coral reef tanks and fresh and salt water aquariums\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhosphate directly inhibits calcification by corals and coralline algae - even at low levels. The health of plants in freshwater aquaria will also be impaired by raised levels of phosphate in the water. Phosphate naturally occurs as waste decomposes in coral reef, salt and fresh water aquariums. While it does not directly harm fish when levels are high, resulting green algae growth can deplete the oxygen levels in water. Corals can lose their colour due to the effects of brown algae.\u003c\/p\u003e\n\u003cp\u003eThe optimum phosphate level - particularly for reef tanks - is often quoted as zero or 0.05 mg\/L (ppm)\u003c\/p\u003e\n\u003cp\u003eWith its ability to register the presence of phosphate in salt and fresh water at extremely low levels, the new Hanna Phosphate Checker offers a real 'must-have' addition to the fish lover's equipment chest.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTesting is quick and easy\u003c\/p\u003e\n\u003cp\u003eHigh precision results - more accurate than chemical test kits\u003c\/p\u003e\n\u003cp\u003eAuto shut-off feature means the Checker cannot be left on by mistake\u003c\/p\u003e\n\u003cp\u003eFully portable, fitting easily into both palm and pocket\u003c\/p\u003e\n\u003cp\u003eFits nicely into your palm or pocket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2 sample cuvettes\u003c\/p\u003e\n\u003cp\u003eCuvette cap\u003c\/p\u003e\n\u003cp\u003eStarter pack of reagents x 6 (re-ordering information HI-713-25 x 25 tests)\u003c\/p\u003e\n\u003cp\u003e1 x 1.5 AAA battery\u003c\/p\u003e\n\u003cp\u003eInstructions\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/testallwater.co.uk\/collections\/hanna-reagents\/products\/hanna-instruments-713-25-reagents-for-hanna-instruments-713-phosphate-pocket-checker-x-25-tests\" target=\"_blank\"\u003eReplacement Reagents For HI-713\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eSku: HI-713\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":41124241014935,"sku":"HI-713","price":71.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/3_2c87e937-ccf3-4e8b-b95d-f49d513e0c74.jpg?v=1733304963"},{"product_id":"hanna-instruments-hi-97711-free-and-total-chlorine-portable-photometer","title":"Hanna Instruments HI-97711 FREE AND TOTAL CHLORINE PORTABLE PHOTOMETER","description":"\u003cp\u003eThis meter offers a superior optical system that utilises a reference detector and narrow band interference filters for extremely fast and repeatable measurements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFree and total chlorine in water up to 5.00 mg\/L (ppm)\u003c\/li\u003e\n\u003cli\u003eNo warm up time before taking a measurement\u003c\/li\u003e\n\u003cli\u003eTutorial mode for step-by-step instructions\u003c\/li\u003e\n\u003cli\u003eUses either powder or cost saving liquid reagents\u003c\/li\u003e\n\u003cli\u003eCAL Check\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HI-97711 has an innovative optical system that offers superior performance in accuracy, repeatability, and the short amount of time it takes to perform a measurement.\u003c\/p\u003e\n\u003cp\u003eThis compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement.\u003c\/p\u003e\n\u003cp\u003eThe use of a backlit dot matrix LED allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different methods, reviewing GLP data, recalling the last 50 measurements, and customising the meter to user preferences.\u003c\/p\u003e\n\u003cp\u003eHI-97711 is waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a protected battery compartment that holds three AA batteries.\u003c\/p\u003e\n\u003cp\u003eThe compact design fits comfortably in the hand for use in the field or on a table for benchtop use. The LCD is 71 mm (2.75\") by 37 mm (1.6\") and is backlit for easy viewing under all conditions.\u003c\/p\u003e\n\u003ch3\u003eStable Light Source:\u003c\/h3\u003e\n\u003cp\u003eThe internal reference system of the HI-97711 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eHigh Efficiency Light Source:\u003c\/h3\u003e\n\u003cp\u003eLED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Filters:\u003c\/h3\u003e\n\u003cp\u003eImproved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eGreater Light Yield:\u003c\/h3\u003e\n\u003cp\u003eA focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.\u003c\/p\u003e\n\u003ch3\u003eCAL Check Functionality:\u003c\/h3\u003e\n\u003cp\u003eHanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.\u003c\/p\u003e\n\u003ch3\u003eMultiple Measurement Methods:\u003c\/h3\u003e\n\u003cp\u003eUsers can select the use of powder reagents supplied in packets or the use of low cost liquid reagents supplied in a dropper bottle.\u003c\/p\u003e\n\u003ch3\u003eBuilt-in Reaction Timer:\u003c\/h3\u003e\n\u003cp\u003eWaiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size:\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the HI-97711 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch3\u003eIntuitive Dot Matrix Display:\u003c\/h3\u003e\n\u003cp\u003eDesigned with a backlit graphic LCD, plus virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.\u003c\/p\u003e\n\u003ch3\u003eAuto-off Protection:\u003c\/h3\u003e\n\u003cp\u003eThe meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/p\u003e\n\u003ch3\u003eAbout Chlorine\u003c\/h3\u003e\n\u003cp\u003eChlorine is a common chemical used by many due to is disinfection, oxidation and bleaching properties.\u003c\/p\u003e\n\u003cp\u003eIn swimming pools, drinking water and food processing, chlorine is used to disinfect and keep bacteria from growing. In metal finishing, it is used as an oxidiser to convert cyanide in wastewater to cyanate.\u003c\/p\u003e\n\u003cp\u003eIn the pulp and paper industry, it is used to bleach wood pulp so that paper is white. The HI-97711 is designed to measure low levels of free and total chlorine in water up to 5.00 mg\/L (ppm).\u003c\/p\u003e\n\u003ch3\u003eAdvanced optical system\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLED that generates very little heat.\u003c\/li\u003e\n\u003cli\u003e8 nm narrowband interference filter that is accurate to +\/- 1 nm and offers 25% increase in light efficiency.\u003c\/li\u003e\n\u003cli\u003eReference detector that modulates the voltage to LED for consistent light output.\u003c\/li\u003e\n\u003cli\u003eA concave focusing lens that reduces errors from imperfections in the cuvette.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAlso available as a kit: HI-97711C Free \u0026amp; Total Chlorine Portable Photometer Kit\u003c\/h3\u003e\n\u003cp\u003eThe HI-97711C kit is supplied with a meter, CAL Check standards, cuvettes (2), caps (2), plastic inserts for cuvettes (2), scissors, a cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and an instrument quality certificate.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Photometer Only","offer_id":43702839738626,"sku":"HI-97711","price":502.46,"currency_code":"GBP","in_stock":true},{"title":"Photometer Plus Case","offer_id":43702839771394,"sku":"HI-97711C","price":736.54,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/hi-97711-free-and-total-chlorine-portable-photometer.jpg?v=1680197791"},{"product_id":"hanna-instruments-hi-718-iodine-handheld-colorimeter-checker","title":"Hanna Instruments HI-718 Iodine Handheld Colorimeter Checker","description":"\u003cp\u003eQuicker and easier to use than chemical test kits, the new HI-718 Iodine Checker from Hanna will give you accurate results in an instant.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFreshwater Aquaculture\u003c\/p\u003e\n\u003cp\u003eFruit and vegetable sanitation\u003c\/p\u003e\n\u003cp\u003eIndustrial processes and disinfection\u003c\/p\u003e\n\u003cp\u003eDrinking water and quality control checks\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note: the HI-718 Iodine Checker cannot be used for swimming pool or spa water testing due to chlorine interference.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccurate and easy to use\u003c\/p\u003e\n\u003cp\u003eAccuracy ±0.1 mg\/L (ppm)\u003c\/p\u003e\n\u003cp\u003e0.01 mg\/L (ppm) resolution\u003c\/p\u003e\n\u003cp\u003eDesigned to work with Hanna reagents\u003c\/p\u003e\n\u003cp\u003eLarge easy to read digits\u003c\/p\u003e\n\u003cp\u003eAuto shut-off\u003c\/p\u003e\n\u003cp\u003eFits into the palm of your hand and pocket\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2 sample cuvettes\u003c\/p\u003e\n\u003cp\u003e1 black cuvette cap\u003c\/p\u003e\n\u003cp\u003eStarter pack of 6 reagents for Iodine (re-ordering information HI-718-25 x 25 tests\u003c\/p\u003e\n\u003cp\u003e1 x 1.5V AAA battery\u003c\/p\u003e\n\u003cp\u003eInstructions\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eAlso available: HI-718-11 Calibration Set.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eSku:HI-718\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"HI-718","offer_id":56418715697525,"sku":"HI-718","price":71.35,"currency_code":"GBP","in_stock":true},{"title":"HI-718-NO REAGENTS","offer_id":56418715730293,"sku":"HI-718-NO REAGENTS","price":39.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/118681_2b83c95b-9b0f-4673-a54f-004a2e528f6d0.jpg?v=1693392117"},{"product_id":"hanna-instruments-hi-747-copper-low-range-colorimeter-checker","title":"Hanna Instruments HI-747 Copper Low Range Colorimeter Checker","description":"\u003cp\u003eThe HI-747 Copper low range Checker is a simple, accurate and cost effective way to measure low ranges of copper in water.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned as a more accurate alternative to chemical test kits, the HI-747 provides quick, accurate results in four easy steps.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eHI-747 uses an adaptation of the EPA method. The reaction between copper and the bicinchoninate reagent causes a purple tint in the sample.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWater quality\u003c\/p\u003e\n\u003cp\u003eEducation\u003c\/p\u003e\n\u003cp\u003ePlating\u003c\/p\u003e\n\u003cp\u003eWastewater\u003c\/p\u003e\n\u003cp\u003eEnvironmental\u003c\/p\u003e\n\u003cp\u003eFreshwater Aquariums\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSmall palm-sized design\u003c\/p\u003e\n\u003cp\u003eAccurate from ±10 ppb ±5% of reading\u003c\/p\u003e\n\u003cp\u003eDedicated to a single parameter\u003c\/p\u003e\n\u003cp\u003eAuto power off after 10 minutes of inactivity\u003c\/p\u003e\n\u003cp\u003eBuilt-in timer for timed reaction readings\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied With\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003esample cuvettes and caps (2),\u003c\/p\u003e\n\u003cp\u003eCopper LR reagent starter kit for 6 tests (re-ordering information HI-747-25 x 25 tests),\u003c\/p\u003e\n\u003cp\u003ebattery,\u003c\/p\u003e\n\u003cp\u003einstructions\u003c\/p\u003e\n\u003cp\u003equick start guide.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eSku: HI-747\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":43701948547330,"sku":"HI-747","price":80.28,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/1_49fc8170-847e-4a64-b954-78266767b09a.png?v=1779119640"},{"product_id":"hanna-instruments-hi-723-chromium-vi-hight-range-checker-hc","title":"Hanna Instruments HI-723 Chromium VI High Range Checker HC","description":"\u003cp\u003eBy monitoring Chromium VI with the Hanna HI-723 High Range Chromium VI Checker serious human health and safety risks can be avoided..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccurate and easy to use\u003c\/p\u003e\n\u003cp\u003eDiphenylcarbohydrazide method\u003c\/p\u003e\n\u003cp\u003eAccuracy ±5 ppb ±4% of reading\u003c\/p\u003e\n\u003cp\u003e1 ppb (µg\/L) resolution\u003c\/p\u003e\n\u003cp\u003eDesigned to work with Hanna reagents\u003c\/p\u003e\n\u003cp\u003eLarge easy to read digits\u003c\/p\u003e\n\u003cp\u003eAuto shut-off\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFruit and vegetable sanitation\u003c\/p\u003e\n\u003cp\u003eDrinking water and quality control checks\u003c\/p\u003e\n\u003cp\u003eElectroplating industries\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2 sample cuvettes\u003c\/p\u003e\n\u003cp\u003e1 black cuvette cap\u003c\/p\u003e\n\u003cp\u003eStarter pack of 6 reagents for Iodine (re-ordering information HI-723-25 x 25 tests)\u003c\/p\u003e\n\u003cp\u003ePowder reagents for chromium VI HR (6)\u003c\/p\u003e\n\u003cp\u003e1 x 1.5V AAA battery\u003c\/p\u003e\n\u003cp\u003eInstructions\u003c\/p\u003e\n\u003cp\u003eSku: HI-723\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":43706500907266,"sku":"HI-723","price":82.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/1_45ce9a92-5d1b-4a5a-b3dc-6962eaddffb7.jpg?v=1728984740"},{"product_id":"hanna-instruments-hi-729-fluoride-low-range-checker","title":"Hanna Instruments HI-729 Fluoride Low Range Checker","description":"\u003cp\u003eFluoride is one of the few chemicals that have been shown to cause significant effects in people through drinking water. Fluoride has beneficial effects on teeth at low concentrations in drinking water, but excessive exposure to fluoride in drinking water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.\u003c\/p\u003e\n\u003cp\u003eThe HI-729 pocket checker is a simple and accurate way to measure low ranges of fluoride.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRange: 0.00 -2.00 ppm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResolution: 0.01ppm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy: 0.10ppm +\/- 5% of reading @25c\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery: 1.5V AAA alkaline\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccurate and easy to use\u003c\/p\u003e\n\u003cp\u003eAdaptation of SPADNS method\u003c\/p\u003e\n\u003cp\u003e±0.05 ppm ±5% of reading\u003c\/p\u003e\n\u003cp\u003e0.01 ppm resolution\u003c\/p\u003e\n\u003cp\u003eDesigned to work with Hanna reagents\u003c\/p\u003e\n\u003cp\u003eLarge easy to read digits\u003c\/p\u003e\n\u003cp\u003eAuto shut-off\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWater testing\u003c\/p\u003e\n\u003cp\u003eQuick on the spot analysis\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2 sample cuvettes with caps\u003c\/p\u003e\n\u003cp\u003eReagents for 6 tests (re-ordering information HI-729-26 x 20 tests\u003c\/p\u003e\n\u003cp\u003eSyringe with tip\u003c\/p\u003e\n\u003cp\u003e1 x 1.5V AAA battery\u003c\/p\u003e\n\u003cp\u003eInstructions\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSku:HI-729\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":43713509392642,"sku":"HI-729","price":85.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/118724_4e2c8536-d78b-4799-bf74-099d8ca5045f0.jpg?v=1702562586"},{"product_id":"hanna-instruments-hi-97710c-ph-free-total-chlorine-portable-photometer-kit","title":"Hanna Instruments HI-97710C pH, Free \u0026 Total Chlorine Portable Photometer Kit","description":"\u003cdiv id=\"product-description-short\" class=\"product__description_short\" itemprop=\"description\"\u003e\n\u003cp\u003eThe HI-97710C kit is supplied with a meter, CAL Check standards, cuvettes (2), caps (2), plastic inserts for cuvettes (2), scissors, a cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and an instrument quality certificate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-features product__features\"\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003epH\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eChlorine\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003ch3\u003eAbout the HI-97710 Photometer\u003c\/h3\u003e\n\u003cp\u003eHI-97710 is an advanced portable photometer for the measurement of pH, free chlorine, and total chlorine in water. This meter offers a superior optical system that utilises a reference detector and narrow band interference filters for extremely fast and repeatable measurements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo warm up time before taking a measurement\u003c\/li\u003e\n\u003cli\u003eTutorial mode for step-by-step instructions\u003c\/li\u003e\n\u003cli\u003eUses either powder or cost saving liquid reagents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe HI-97710 has an innovative optical system that offers superior performance in accuracy, repeatability, and the short amount of time it takes to perform a measurement. This compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement. The use of a backlit dot matrix LED allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different methods, reviewing GLP data, recalling the last 50 measurements, and customising the meter to user preferences.\u003c\/p\u003e\n\u003cp\u003eHI-97710 is waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a protected battery compartment that holds three AA batteries. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use. The LCD is 71 mm (2.75\") by 37 mm (1.6\") and is backlit for easy viewing under all conditions.\u003c\/p\u003e\n\u003ch3\u003eStable Light Source:\u003c\/h3\u003e\n\u003cp\u003eThe internal reference system of the HI-97710 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eHigh Efficiency Light Source:\u003c\/h3\u003e\n\u003cp\u003eLED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eHigh Quality Filters:\u003c\/h3\u003e\n\u003cp\u003eImproved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eGreater Light Yield:\u003c\/h3\u003e\n\u003cp\u003eA focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eCAL Check Functionality:\u003c\/h3\u003e\n\u003cp\u003eHanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eMultiple Measurement Methods:\u003c\/h3\u003e\n\u003cp\u003eUsers can select the use of powder reagents supplied in packets or the use of low cost liquid reagents supplied in a dropper bottle.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eBuilt-in Reaction Timer:\u003c\/h3\u003e\n\u003cp\u003eWaiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size:\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the HI-97710 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eIntuitive Dot Matrix Display:\u003c\/h3\u003e\n\u003cp\u003eThe HI-97710 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eAuto-off Protection:\u003c\/h3\u003e\n\u003cp\u003eThe meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eAbout Chlorine\u003c\/h3\u003e\n\u003cp\u003eChlorine is a common chemical used by many due to is disinfection properties.\u003c\/p\u003e\n\u003cp\u003eFree chlorine can exist in two forms and which form is present is based on the pH. At pH less than 7.6, the predominate form is hypochlorous acid (HOCl), while at pH greater than 7.6, the hypochlorite (OCl-) form becomes predominate.\u003c\/p\u003e\n\u003cp\u003eThis is very important when it comes to preventing biological growth in water or keeping a swimming pool safe since hypochlorous acid is 100 times more effective as a sanitiser.\u003c\/p\u003e\n\u003cp\u003eTotal chlorine represents both the free chlorine and combined chlorine present.\u003c\/p\u003e\n\u003cp\u003eCombined chlorine is the chlorine bound to nitrogen substances such as ammonia. In swimming pools, combined chlorine is what we can smell and is irritating to the eyes. The free chlorine measurement is subtracted from the total chlorine measurement in order to know how much combined chlorine is present. HI-97710 is designed to measure pH and low levels of free and total chlorine in water up to 5.00 mg\/L (ppm).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eAdvanced optical system\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLED that generates very little heat.\u003c\/li\u003e\n\u003cli\u003e8 nm narrowband interference filter that is accurate to +\/- 1 nm and offers 25% increase in light efficiency.\u003c\/li\u003e\n\u003cli\u003eReference detector that modulates the voltage to LED for consistent light output.\u003c\/li\u003e\n\u003cli\u003eA concave focusing lens that reduces errors from imperfections in the cuvette.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 to 8.5 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eadaptation of Phenol Red method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eadaptation of the EPA 330.5 DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003esilicon photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eround, 24.6 mm diameter (22 mm inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003edate, time of last calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel B\/W LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e50 measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA battery (3 pcs.) \/ \u0026gt; 800 measurements (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 15 minutes of inactivity (30 minutes before a READ measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); relative humidity: 100% (IP 67, floating case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g (13.4 oz.) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eKit: HI-97710C is supplied with a meter, CAL-Check standards, cuvettes (2), caps (2), plastic inserts for cuvettes (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":56336721510773,"sku":null,"price":707.15,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-97710c-ph-free-total-chlorine-portable-photometer-kit.jpg?v=1763076305"},{"product_id":"hanna-instruments-hi-802-iris-visible-spectrophotometer-with-barcode-reader","title":"Hanna Instruments HI-802 Iris Visible Spectrophotometer with Barcode Reader","description":"\u003cdiv id=\"product-description-short\" class=\"product__description_short\" itemprop=\"description\"\u003e\n\u003cp\u003eThe Iris Spectrophotometer is a highly versatile, reliable solution for measuring samples. Over 100 factory methods, automatic method identification with Hanna reagent vial barcodes and vial rotation with averaging provide exceptional accuracy across all visible light wavelengths. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-features product__features\"\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eWavelength 340 to 900nm\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAdvanced split beam optical system\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAccuracy ±1.5nm\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e99 parameters\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cp\u003eThe Iris Spectrophotometer from Hanna Instruments is an exceptionally accurate, reliable and repeatable solution for measurements across all visible wavelengths. This compact, versatile instrument is suitable for measurement on the benchtop of a laboratory, when testing on-site and for measurement in the field, with full portability and a lithium-ion battery with charge for approximately 3,000 measurements.\u003c\/p\u003e\n\u003cp\u003eIn addition to versatility, the Iris is also easy-to-use, with barcode recognition on Hanna liquid vial reagents to immediately identify the vial, allowing you to apply methods to specific samples and save time on testing. A pre-programmed favourites menu and the ability to create completely custom curves inclusive of averaging allow the Iris to be customised to your requirements for efficient operation.\u003c\/p\u003e\n\u003ch2\u003eIris Spectrophotometer Features\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAutomatic vial recognition with barcode reader\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe HI-802 Iris features automatic recognition of compatible Hanna vial reagents, using a barcode reader to immediately set up and test. This system reduces time in testing, with no need to navigate menus. Simply insert the vial into the spectrophotometer to begin the testing process, reducing errors and ensuring the correct method is used every time.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eElectronic Zero functionality\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eElectronic zero functionality saves time and effort when testing. Store the Zero a single time for measurement with DI water blank correction, ensuring stable readings. Using this option allows you to bypass the interface, for fast, convenient and accurate testing with a shared single-zero that delivers fast results.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eExceptional accuracy with the Average Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eAchieve exceptional accuracy in measurement with the Average Function, with compatible 13 mm vials completing a rotation with 256 readings for high precision in testing. The averaging option is available for both pre-programmed and custom methods, providing complete flexibility while ensuring accurate results from measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOver 100 pre-programmed methods\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe HI-802 Iris is pre-programmed with 90 commonly-used methods, with over 100 factory methods available to further improve the versatility of this spectrophotometer. Add methods directly to the favourites menu for easy access, or utilise the barcode system with compatible Hanna cuvette reagents to automatically detect methods directly.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCustomise the Iris with up to 100 custom methods\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eIn addition to the existing methods, the Iris can be fully customised with your own methods to suit niche or less common requirements. Our expert team at Hanna can support you in programming curves for specific purposes, making the Iris an ideal solution for a wide range of industries and specialist applications.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCoverage for all visible wavelengths\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Iris Spectrophotometer from Hanna is capable of testing across the entire spectral range of visible light from 340 nm to 900 nm. This offers comprehensive coverage for common analytical methods, with excellent flexibility to adapt Iris methods to specific regulatory or industry requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eComprehensive vial compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eHanna’s portable spectrophotometer includes a cuvette holder and multiple adaptors to expand the range of cuvettes that can be measured with the Iris. These include 22 mm round and 5 cm path length rectangular vials as standard, with included adapters for 13 mm, 16 mm, and 10 mm cuvettes. The 13 mm adaptor includes a barcode reader and allows for the use of the Iris average function.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCapacitive touchpad for use even with gloves\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA capacitive touchpad with optional audio feedback ensures the Iris is suited to many environments, from laboratories with strict sterility requirements to use in the field. This spectrophotometer features a simple LCD display with button navigation, allowing you to change settings, switch methods and access favourites with ease even with gloves on.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSuitable for the lab or the field\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eWhether you are working from a laboratory benchtop or out in the field, the HI-802 Iris is an ideal solution. This versatile spectrophotometer includes a rechargeable lithium-ion battery that provides charge for approximately 3,000 measurements before recharging is required, with a size and weight that makes portability easy.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePractical part replacement\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe HI-802 Spectrophotometer is designed with a tungsten-halogen light for greater energy efficiency, longer service life and improved light quality across our wide wavelength range. Replacement lamps are shipped directly to you, pre-aligned and ready to be installed, with no need to send your whole spectrophotometer to use for replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eEasy, universal data transfer\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hanna Iris has the capacity for up to 9,999 data points, allowing a large amount of measurements to be stored within the spectrophotometer before transfer is required. Directly connect to a Mac or PC or transfer data with a USB drive. All data is available in universal PDF and CSV file formats, with no requirement for specialist software.\u003c\/p\u003e\n\u003ch2\u003eAbout Hanna Barcode Reagents\u003c\/h2\u003e\n\u003cp\u003eHanna’s barcode reagents are an ideal solution for easy testing in combination with the HI-802 Iris Spectrophotometer. From COD testing to surfactant measurement, our range of reagent vials is fully compatible with our spectrophotometer with instant method recognition following setup. Browse our range of reagents online here. For reagent skus - please see Specification for each individual parameter.\u003c\/p\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003ch3\u003eWhat industries is Iris suitable for?\u003c\/h3\u003e\n\u003cp\u003eHanna’s Iris Spectrophotometer is a versatile option suited to a wide range of industries with different regulatory requirements. The comprehensive wavelength range and functionality of this portable meter make it an excellent choice for wastewater measurement in laboratories, industrial applications and environmental testing. \u003c\/p\u003e\n\u003ch3\u003eCan the Iris be customised to my requirements?\u003c\/h3\u003e\n\u003cp\u003eOur in-house team preprograms each Iris Spectrophotometer before it is shipped to meet the unique requirements of our customers. This includes adding your most applicable methods to the favourites menu for effortless testing. \u003c\/p\u003e\n\u003ch3\u003eCan I book training for spectrophotometers?\u003c\/h3\u003e\n\u003cp\u003eOur team of specialists can provide complete training on the purchase of an Iris Spectrophotometer if required. \u003c\/p\u003e\n\u003ch3\u003eIs the Iris Spectrophotometer portable?\u003c\/h3\u003e\n\u003cp\u003eThe Iris has a compact footprint and is easy to carry thanks to these dimensions, allowing it to fit into a dedicated backpack for on-site testing. This spectrophotometer also has a lithium-ion battery for complete portability, with no need for direct power connection to operate anywhere, from out in the field to in-lab testing.\u003c\/p\u003e\n\u003ch3\u003eHow big is the Iris Spectrophotometer?\u003c\/h3\u003e\n\u003cp\u003eThe Iris has dimensions of 155 x 205 x 322 mm. This spectrophotometer weighs 3kg (6.6 lbs), allowing it to be carried to different places for testing. This includes the battery, providing a full testing solution that is portable and compact enough to fit anywhere on a benchtop.\u003c\/p\u003e\n\u003ch3\u003eWhat reagents should you use with the Iris?\u003c\/h3\u003e\n\u003cp\u003eHanna has a full range of vial reagents for use with the HI-802 Iris, in addition to powder reagents for specific tests. Barcode vials are available for convenient testing, with the Iris scanning the barcode to start the testing process with no additional navigation required. Our comprehensive range includes COD reagents, surfactant reagents and reagents for a wide range of common tests. \u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":56633751273845,"sku":"HI-802-02","price":3480.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-802-visible-spectrophotometer-with-method-identification-via-barcode-reader.jpg?v=1768857381"},{"product_id":"hanna-instruments-hi-97718-iodine-photometer-range-0-0-to-12-5-mg-l-ppm","title":"Hanna Instruments HI-97718 Iodine photometer: range 0.0 to 12.5 mg\/L (ppm)","description":"\u003cp\u003eThis meter offers a superior optical system that utilises a reference detector and narrow band interference filters for extremely fast and repeatable measurements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo warm up time before taking a measurement\u003c\/li\u003e\n\u003cli\u003eTutorial mode for step-by-step instructions\u003c\/li\u003e\n\u003cli\u003eUses either powder or cost saving liquid reagents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach photometer is delivered in a cardboard box and is supplied with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSample cuvette (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eSample cuvette cap (2 pcs.)\u003c\/li\u003e\n\u003cli\u003ePlastic stopper (2 pcs.)\u003c\/li\u003e\n\u003cli\u003e1.5V AA Alkaline batteries\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate\u003c\/li\u003e\n\u003cli\u003eInstruction manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe photometer has an innovative optical system that offers superior performance in accuracy, repeatability and the short amount of time it takes to perform a measurement. This compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement. The use of a backlit dot matrix LED allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different methods, reviewing GLP data, recalling the last 50 measurements, and customising the meter to user preferences.\u003c\/p\u003e\n\u003cp\u003eThe photometer is waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a protected battery compartment that holds three AA batteries. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use. The LCD is 71 mm (2.75\") by 37 mm (1.6\") and is backlit for easy viewing under all conditions.\u003c\/p\u003e\n\u003ch3\u003eAdvanced optical system\u003c\/h3\u003e\n\u003cp\u003eLED that generates very little heat.\u003c\/p\u003e\n\u003cp\u003e8 nm narrowband interference filter that is accurate to +\/- 1 nm and offers 25% increase in light efficiency.\u003c\/p\u003e\n\u003cp\u003eReference detector that modulates the voltage to LED for consistent light output.\u003c\/p\u003e\n\u003cp\u003eA concave focusing lens that reduces errors from imperfections in the cuvette.\u003c\/p\u003e\n\u003ch3\u003eStable Light Source:\u003c\/h3\u003e\n\u003cp\u003eThe internal reference system of the photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch3\u003eHigh Efficiency Light Source:\u003c\/h3\u003e\n\u003cp\u003eLED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.\u003c\/p\u003e\n\u003ch3\u003eHigh Quality Filters:\u003c\/h3\u003e\n\u003cp\u003eImproved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch3\u003eGreater Light Yield:\u003c\/h3\u003e\n\u003cp\u003eA focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.\u003c\/p\u003e\n\u003ch3\u003eCAL Check Functionality:\u003c\/h3\u003e\n\u003cp\u003eHanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.\u003c\/p\u003e\n\u003ch3\u003eMultiple Measurement Methods:\u003c\/h3\u003e\n\u003cp\u003eUsers can select the use of powder reagents supplied in packets or the use of low cost liquid reagents supplied in a dropper bottle.\u003c\/p\u003e\n\u003ch3\u003eBuilt-in Reaction Timer:\u003c\/h3\u003e\n\u003cp\u003eWaiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.\u003c\/p\u003e\n\u003ch3\u003eLarge Cuvette Size:\u003c\/h3\u003e\n\u003cp\u003eThe sample cell of the photometer fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch3\u003eIntuitive Dot Matrix Display:\u003c\/h3\u003e\n\u003cp\u003eThe photometer is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.\u003c\/p\u003e\n\u003ch3\u003eAuto-off Protection:\u003c\/h3\u003e\n\u003cp\u003eThe meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/p\u003e\n\u003ch3\u003eAbout Iodine\u003c\/h3\u003e\n\u003cp\u003eDisinfectant properties of iodine has led to its use as an alternative to chlorine and bromine. Unlike chlorinated pools, water treated with iodine decreases eye irritation among swimmers and provides a level of disinfection more stable to adverse conditions. However, its toxic and corrosive properties, along with the difficulties of dissolving it in water, have limited its widespread acceptance. One of the most common applications of iodine is in poultry industry process water.\u003c\/p\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 12.5 mg\/L (ppm) (as I\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th ed. DPDMethod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eround, 24.6 mm diameter (22 mm inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDate, time of last calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel B\/W LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e50 measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA battery (3 pcs.) \/ \u0026gt; 800 measurements (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 15 minutes of inactivity (30 minutes before a READ measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); relative humidity: 100% (IP 67, floating case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e380g with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e142.5 x 102.5 x 50.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-97718 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagents and CAL Check Standards\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHI-97718-11 CAL Check Standard Cuvettes\u003cbr\u003eHI-93718-01 Reagents 100 tests\u003cbr\u003eHI-93718-03 Reagents 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57247042896245,"sku":"HI-97718","price":495.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-97718-iodine-photometer-range-00-to-125-mgl-ppm.jpg?v=1780481971"},{"product_id":"hanna-instruments-hi-6522-ph-orp-ise-ec-multiparameter-modular-benchtop-meter","title":"Hanna Instruments HI-6522 pH\/ORP\/ISE + EC Multiparameter Modular Benchtop Meter","description":"\u003cp\u003e\u003cspan\u003eHI-6522 pH\/ORP\/ISE + EC Multiparameter Modular Benchtop Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis kit includes the necessary modules and probes to measure pH, temperature and conductivity, providing everything needed to start measuring straight out of the box. This advanced multimeter features WiFi and ethernet connectivity. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-features product__features\"\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e EC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eISE\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eORP\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003epH\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cp\u003eThe HI-6522 Kit for the HI-6000 includes the HI-6000 modular laboratory meter system, a HI-6000-2 pH\/ISE module and a HI-6000-3 EC module. Also included is the \u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/57-ph-electrode-glass-body-general-purpose-for-laboratory\"\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e\u003c\/a\u003e, \u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/2980-hi-7662-tw-temperature-probe\"\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e\u003c\/a\u003e and\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/2974-hi-7631233-platinum-four-ring-ec-and-resistivity-probe\"\u003eHI-7631233 EC and resistivity probe\u003c\/a\u003e\u003c\/span\u003e. This kit includes everything needed for the accurate measurement of EC and pH, including a calibration solution starter set for EC and pH.\u003c\/p\u003e\n\u003cp\u003eHI-6000 is a fully flexible measurement platform that can be customised according to the user’s application needs. Designed and developed using the latest generation technologies, it gives complete control over measurements.\u003c\/p\u003e\n\u003cp\u003eThis kit is compatible with a wide range of Hanna Instruments electrodes for ISE measurement. For advice on the best electrodes for your needs speak to our in-house specialists directly.\u003c\/p\u003e\n\u003cp\u003eSix different pre-built kits are available for the HI-6000 multimeter, including the modules and electrodes required for laboratory-grade measurement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2988-hi-6222-02-ph-orp-ise-multiparameter-modular-benchtop-system\"\u003eHI-6222 pH\/ORP\/ISE Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2989-hi-6522-02-ph-orp-ise-ec-multiparameter-modular-benchtop-system\"\u003eHI-6522 pH\/ORP\/ISE + EC Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2990-hi-6542-02-ph-orp-ise-optical-do-multiparameter-modular-benchtop-system\"\u003eHI-6542 pH\/ORP\/ISE + Optical DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2991-hi-6542p-02-ph-orp-ise-polarographic-do-multiparameter-modular-benchtop-system\"\u003eHI-6542\/P pH\/ORP\/ISE + Polarographic DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2992-hi-6553-02-ph-orp-ise-ec-optical-do-multiparameter-modular-benchtop-system\"\u003eHI-6553 pH\/ORP\/ISE + EC + Optical DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2993-hi-6553p-02-ph-orp-ise-ec-polarographic-do-multiparameter-modular-benchtop-system\"\u003eHI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003eSpecification:\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHI-6522-02 pH\/ORP\/ISE + EC Kit\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003emV\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1 x 10\u003csup\u003e-6\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eto 9.99 x 10\u003csup\u003e10\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econcentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1; 0.1; 0.01; 0.001 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV offset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003epH Calibration\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard buffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOffset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable; Isopotential point: -2.000 to 20.000pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConductivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm; 100.0 to 999.9 μS\/cm;\u003cbr\u003e1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e0.0500 to 200.00 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Type\u003c\/td\u003e\n\u003ctd\u003eautomatic; manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eSingle\u003cbr\u003eMultiple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration solutions\u003c\/td\u003e\n\u003ctd\u003e84.00 μS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear, natural, standard, disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003eRange: 5.0 to 30.0˚C (41.0 to 86.0˚C\u003cbr\u003eResolution 0.1˚C \/ 0.1˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00%\/˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eResistivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 Ω・cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTotal Dissolved Solids (TDS)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSalinity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU - Practical Scale\u003cbr\u003e0.00 to 80.00 ppt - Natural Sea Water\u003cbr\u003e0.0 to 400.0 % - Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 for Practical Scale \/ Natural Sea Water\u003cbr\u003e0.1 % for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 point for Percent Scale, using 100% salinity calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C; -4.0 to 248.0˚F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57492952875381,"sku":"HI-6522-02","price":1282.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-6522-02-ph-orp-ise-ec-multiparameter-modular-benchtop-system.jpg?v=1786545063"}],"url":"https:\/\/testallwater.co.uk\/collections\/chemical-and-laboratory-analysis.oembed","provider":"Test All Water","version":"1.0","type":"link"}