{"title":"Benchtop Meters","description":null,"products":[{"product_id":"hanna-instruments-83300-02-multi-parameter-benchtop-photometer-ph-meter","title":"Hanna Instruments-83300-02 Multi-parameter Benchtop Photometer \u0026 pH meter","description":"One meter can be used for both photometric and pH measurements. The meter has 60 different programmed methods measuring 37 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the Hanna Instruments-83300 doubles as a professional pH meter with its digital pH\/temperature electrode input.\u003cbr\u003e\u003ch3\u003eAdvanced optical system - Unparalleled performance from a benchtop photometer.\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eHanna Instruments-83300 is a compact, multi-parameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eFrom Aluminium to Zinc, the Hanna Instruments-83300 benchtop photometer measures 37 water quality parameters using 60 different methods. The photometer features an innovative optical system that uses LEDs, narrow band interference filters, and a focusing lens. It also has a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eThe Hanna Instruments-83300 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Efficiency LED Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eHigh Quality Narrow Band Interference Filters\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (+\/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eReference Detector for a Stable Light Source\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eA beam splitter is used as part of the internal reference system of the Hanna Instruments-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eLarge Cuvette Size\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe sample cell of the Hanna Instruments-83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eFocusing Lens for Greater Light Yield\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eKey features:\u003c\/h3\u003e\u003cbr\u003e\u003cul\u003e\n\u003cbr\u003e\u003cli\u003eAdvanced optical system with brighter, long-lasting LED light source\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBacklit 128 x 64 Pixel Graphic Liquid Crystal Display\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eAbsorbance mode - concentration versus absorbance\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eUnits of Measurement plus chemical form displayed\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eResult conversion at the touch of a button\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCuvette cover\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003epH and temperature measurement with a single probe\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eGood Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eCAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eData Logging - Up to 1000 photometric and pH readings can be stored\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eBattery Status Indicator\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eError Messages\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":40354375467159,"sku":"HI-83300-02","price":1489.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/products\/heater_3_dc75fef9-64f1-4563-8b90-e8a5f746505a.jpg?v=1624278832"},{"product_id":"hanna-instruments-hi-6522-ph-orp-ise-ec-multiparameter-modular-benchtop-meter","title":"Hanna Instruments HI-6522 pH\/ORP\/ISE + EC Multiparameter Modular Benchtop Meter","description":"\u003cp\u003e\u003cspan\u003eHI-6522 pH\/ORP\/ISE + EC Multiparameter Modular Benchtop Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis kit includes the necessary modules and probes to measure pH, temperature and conductivity, providing everything needed to start measuring straight out of the box. This advanced multimeter features WiFi and ethernet connectivity. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-features product__features\"\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e EC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eISE\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eORP\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"13.987\" height=\"10.123\" viewbox=\"0 0 13.987 10.123\"\u003e\u003cg transform=\"translate(-305.142 -213.686)\"\u003e\u003cpath class=\"a\" d=\"M309.809,222a3.892,3.892,0,0,1,.262-.345q3.768-3.778,7.539-7.551a2.462,2.462,0,0,1,.289-.267.763.763,0,0,1,1.017.106.788.788,0,0,1,.043,1.025,2.512,2.512,0,0,1-.188.2l-8.273,8.275a.831.831,0,0,1-1.394-.01q-1.854-1.854-3.707-3.71a.8.8,0,0,1-.182-.915.727.727,0,0,1,.818-.43,1.16,1.16,0,0,1,.535.3c1,.985,1.989,1.983,2.979,2.98A3.938,3.938,0,0,1,309.809,222Z\" transform=\"translate(0)\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003c\/svg\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003epH\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cp\u003eThe HI-6522 Kit for the HI-6000 includes the HI-6000 modular laboratory meter system, a HI-6000-2 pH\/ISE module and a HI-6000-3 EC module. Also included is the \u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/57-ph-electrode-glass-body-general-purpose-for-laboratory\"\u003e\u003cspan\u003eHI-1131B pH electrode\u003c\/span\u003e\u003c\/a\u003e, \u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/2980-hi-7662-tw-temperature-probe\"\u003e\u003cspan\u003eHI-7662-TW temperature probe\u003c\/span\u003e\u003c\/a\u003e and\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/electrodes-and-probes\/2974-hi-7631233-platinum-four-ring-ec-and-resistivity-probe\"\u003eHI-7631233 EC and resistivity probe\u003c\/a\u003e\u003c\/span\u003e. This kit includes everything needed for the accurate measurement of EC and pH, including a calibration solution starter set for EC and pH.\u003c\/p\u003e\n\u003cp\u003eHI-6000 is a fully flexible measurement platform that can be customised according to the user’s application needs. Designed and developed using the latest generation technologies, it gives complete control over measurements.\u003c\/p\u003e\n\u003cp\u003eThis kit is compatible with a wide range of Hanna Instruments electrodes for ISE measurement. For advice on the best electrodes for your needs speak to our in-house specialists directly.\u003c\/p\u003e\n\u003cp\u003eSix different pre-built kits are available for the HI-6000 multimeter, including the modules and electrodes required for laboratory-grade measurement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2988-hi-6222-02-ph-orp-ise-multiparameter-modular-benchtop-system\"\u003eHI-6222 pH\/ORP\/ISE Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2989-hi-6522-02-ph-orp-ise-ec-multiparameter-modular-benchtop-system\"\u003eHI-6522 pH\/ORP\/ISE + EC Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2990-hi-6542-02-ph-orp-ise-optical-do-multiparameter-modular-benchtop-system\"\u003eHI-6542 pH\/ORP\/ISE + Optical DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2991-hi-6542p-02-ph-orp-ise-polarographic-do-multiparameter-modular-benchtop-system\"\u003eHI-6542\/P pH\/ORP\/ISE + Polarographic DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2992-hi-6553-02-ph-orp-ise-ec-optical-do-multiparameter-modular-benchtop-system\"\u003eHI-6553 pH\/ORP\/ISE + EC + Optical DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.hannainstruments.co.uk\/home\/2993-hi-6553p-02-ph-orp-ise-ec-polarographic-do-multiparameter-modular-benchtop-system\"\u003eHI-6553\/P pH\/ORP\/ISE + EC + Polarographic DO Kit\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cspan\u003e\u003c\/span\u003eSpecification:\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHI-6522-02 pH\/ORP\/ISE + EC Kit\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003emV\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1 x 10\u003csup\u003e-6\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eto 9.99 x 10\u003csup\u003e10\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econcentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1; 0.1; 0.01; 0.001 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV offset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003epH Calibration\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard buffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOffset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature User Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable; Isopotential point: -2.000 to 20.000pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConductivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm; 100.0 to 999.9 μS\/cm;\u003cbr\u003e1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e0.0500 to 200.00 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Type\u003c\/td\u003e\n\u003ctd\u003eautomatic; manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration points\u003c\/td\u003e\n\u003ctd\u003eSingle\u003cbr\u003eMultiple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration solutions\u003c\/td\u003e\n\u003ctd\u003e84.00 μS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear, natural, standard, disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003eRange: 5.0 to 30.0˚C (41.0 to 86.0˚C\u003cbr\u003eResolution 0.1˚C \/ 0.1˚F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00%\/˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eResistivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 Ω・cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTotal Dissolved Solids (TDS)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSalinity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU - Practical Scale\u003cbr\u003e0.00 to 80.00 ppt - Natural Sea Water\u003cbr\u003e0.0 to 400.0 % - Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 for Practical Scale \/ Natural Sea Water\u003cbr\u003e0.1 % for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 point for Percent Scale, using 100% salinity calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C; -4.0 to 248.0˚F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":57492952875381,"sku":"HI-6522-02","price":1282.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/5511\/6439\/files\/hi-6522-02-ph-orp-ise-ec-multiparameter-modular-benchtop-system.jpg?v=1786545063"}],"url":"https:\/\/testallwater.co.uk\/collections\/benchtop-meters.oembed","provider":"Test All Water","version":"1.0","type":"link"}